Ground source heat pump (GSHP) system is highly efficient and environment-friendly and supplies heating, cooling and hot water to buildings. For an optimal design of the GSHP system, the ground thermal properties should be determined to estimate the heat exchange rate between ground and borehole heat exchangers (BHE) and the system performance during long-term operating periods. However, the process increases the initial cost and construction period, which causes the system to be hindered in distribution. On the other hand, much research has been applied to the artificial neural network (ANN) to solve problems based on data efficiently and stably. This research proposes the predictive performance model utilizing ANN considering local characteristics and weather data for the predictive performance model. The ANN model predicts the entering water temperature (EWT) from the GHEs to the heat pump for the modular GHEs, which were developed to reduce the cost and spatial disadvantages of the vertical-type GHEs. As a result, the temperature error between the data and predicted results was 3.52%. The proposed approach was validated to predict the system performance and EWT of the GSHP system.
다양한 기능의 새로운 물질을 합성하고 정적 및 동적 특성을 조사하기 위해서는 매우 안정된 고온 및 고압 조건을 만드는 것이 중요하다. 새로운 물질을 제조하는 데 필요한 다이아몬드 엔빌 셀 (DAC)을 사용하여 Mbar 범위의 고압 조건은 이미 확보되었다. 이 연구에서는 DAC와 결합된 레이저 가열 시스템을 설계하였으며, DAC의 양쪽 방향에서 시료를 가열하기 위해 2 대의 1064 nm, 100 W 파이버 레이저를 사용했을 뿐만 아니라 3 대의 분광기를 사용하여 온도, 압력 및 라만 스펙트럼을 측정하였다. 고압 실험에서 시료를 가두는 구멍으로 일반적으로 사용되는 스테인리스 강 개스킷을 가열하여 열 방사선원을 만들고, 이 방사선원으로부터 방출되는 복사 스펙트럼을 획득하여 가열된 개스킷의 온도를 측정하였다. 이 기술을 적용하여 다양한 물질들을 만들고 극한 조건에서 물리적 특성을 조사 할 수 있다.
본 연구에서는 온실 내부의 태양 잉여열과 외부의 공기열을 선택적으로 열원으로 이용함으로써 히트펌프의 성능을 향상시키고, 온실의 환기 지연을 통해 이산화탄소 시용비용을 절감할 수 있는 온실 공조시스템을 개발하고자 하였다. 본 시스템의 축열 과정은 태양 잉여열을 이용하는 내부순환모드와 외기열을 이용하는 외부순환모드가 온실 내부온도에 따라 자동으로 절환되도록 구성하였으며, 히트펌프 가동, 축열모드 절환, 난방 가동을 위한 6개의 온도값을 입력함으로써 축열과 난방이 자동으로 수행되도록 설계하였다. 단동온실을 대상으로 무환기 조건에서 기초시험을 수행한 결과, 태양 잉여열을 이용한 축열은 약 11시부터 시작되어 평균 3시간 30분 정도 유지되었으며, 주간의 온실 내부온도는 환기를 수행하지 않음에도 대부분 약 $20{\sim}28^{\circ}C$ 범위를 유지하였다. 주간 내부순환모드에서 시스템의 난방성능계수는 약 3.35로 야간 외부순환모드의 2.46 및 주간 외부순환모드의 2.67에 비해 각각 36% 및 25% 향상됨을 확인하였다. 본 시스템의 개선사항으로 태양 잉여열의 효율적 이용을 위해 축열조 관리온도를 상승시킬 수 있는 고효율 히트펌프의 적용이 필요하며, 온실의 무환기 운용에 따른 과습환경의 조성을 방지하고 태양 잉여열 수준이 높은 시기에 온실의 온도상승을 방지하기 위해 강제환기를 운전모드에 추가할 필요가 있는 것으로 판단되었다.
쓰레기 소각장이나 산업체의 폐열을 농업에 활용한 사례는 몇몇 있었다. 그러나 온배수를 농업에 활용한 사례는 전무하였으며, 치어, 종패 등을 양식하는 수산업이 대부분이었다. 본 연구에서는 화력발전소의 온배수(폐열)를 열원으로 이용하는 120 RT 규모의 냉난방시스템을 제주특별자치도 서귀포시 안덕면 소재의 $5,280m^2$ 아열대 작물(망고) 재배온실에 설치, 10월에서 다음해 2월까지 약 5개월 동안 난방을 실시하여 난방에너지 비용 절감 효과 등 분석하였다. 난방에너지 비용 절감효과는 면세경유에 대하여 87%이였으며, 또한 발전소의 온배수를 에너지원으로 재활용함으로서 62%의 이산화탄소 배출 저감 효과를 얻었다. 본 연구를 계기로 2015년에 해수가 수열에너지 분야로 재생에너지에 포함되었다. 해수의 표층의 열을 히트펌프를 사용하여 변환시켜 얻은 에너지라는 수열에너지 분야의 기준과 범위를 볼 때, 이는 온배수가 재생에너지에 포함되었다고 말해도 과언이 아닐 것으로 사료된다. 그 이유는 온배수도 해수임에도 불구하고 온도가 일반 해수보다 $7{\sim}8^{\circ}C$ 높아, 일반 해수를 히트펌프의 열원으로 이용하는 것보다 온배수를 열원으로 이용했을 때 히트펌프의 성능이 높기 때문이다. 또한 같은 해 농식품부의 폐열 재이용 시설 지원 사업이 발표되어, 발전소 온배수뿐만 아니라 산업체와 소각장의 폐열을 농업에 활용하면 지원을 받을 수 있게 되었다. 이 사업에 의하여 2015년 당진시, 하동군, 제주시, 곡성군이 선정되었으며, 2016년 태안군, 서귀포시 등이 선정되어, 2016년 말 곡성군과 제주시가 공사를 완료, 농업에 폐열을 활용하고 있으며(제주시는 발전소, 곡성군은 산업체 폐열을 이용하고 있음), 기타 지역은 추진 중이다.
Solar energy is one of the important renewable energy resources. It can be used for air heating, hot water supply, heat source of desiccant cooling system and so on. And many researches for enhancing efficiency have been conducted because of these various uses of solar thermal energy. This study was performed to investigate the air heating performance of hybrid solar air-water heater that can heat air and liquid respectively or simultaneously and finding method for improving thermal performance of this collector. This collector has both liquid pipe and air channel different with the traditional solar water and air heater. Fins were installed in the air channel for enhancing the air heating performance of collector. Also air inlet & outlet temperature, ambient temperature and solar collector's inner part temperature were confirmed with different air velocity on similar solar irradiance. As a result, temperature of heated air was shown about $43^{\circ}C$ to $60^{\circ}C$ on the $30^{\circ}C$ of ambient temperature and thermal efficiency of solar collector was shown 28% to 73% with respect to air velocity. Also, possibility of improvement of thermal performance of this collector could be ascertained from the heat transfer coefficient calculated from this experiment. Thus, it is considered that the research for finding optimal structure of hybrid solar air-water heater for enhancing thermal performance might be needed to conduct as further study based on the method for improving air heating performance confirmed in this study.
국내 하수슬러지는 2012년부터 런던협약에 의해 해양투기가 금지될 예정에 있어 이에 대한 처리방법이 절실한 실정이다. 본 연구에서는 하수슬러지 케익을 재활용하기 위한 방법으로 탄화공정을 이용하여 탄화물 제조 및 에너지 특성에 대한 검토를 실시하였다. 하수슬러지 케익의 기초적 특성과 조성에 의하면, 하수슬러지 케익에는 27%의 인산염이 포함되어 있으며 이는 환원제로서 유해물질 처리에 이용될 수 있다. 하수슬러지 케익의 발열량을 파악한 결과, 저위발열량은 38.7 kcal/kg으로 하수슬러지 케익을 탄화하지 않고 직접 에너지원으로 사용하는 것은 바람직하지 않다. 하수슬러지 케익의 탄화공정에서 최적 탄화온도와 최적 탄화시간은 $250^{\circ}C$와 15분으로 설정되었다. 이 조건에서의 탄화물의 발열량은 비교적 낮아 하수슬러지 케익 탄화물 자체는 신재생 에너지원으로의 가능성은 크지 않다고 판단되나 인산염이 27% 정도가 포함되어 있어 다른 유기성 폐기물과 혼합하여 탄화하는 것이 적합하다고 판단되었다.
가정 가사생활을 자동으로 관리 하는 Home Automation System은 점차 발전하고 있으며, 에너지의 절약과 재사용에 관한 부분 또한 점차 관심이 높아지고 있다. 일반 아파트에서 난방은 필수이다. 난방의 방법은 크게 두가지로 나눈다. 하나는 전기를 이용하는 것이고 다른 하나는 온수를 이용하는 것이다. 전기를 이용하면 전기요금의 상승으로 효률적이지 못하다. 그러나 온수를 이용하면 비용 면에서 많은 절감이 된다. 온수를 이용할 때, 온수의 온도가 모든 파이프에서 동일하지 못하다. 그러므로 실내의 온도를 설정치와 일치하지 못할때가 있다. 이러한 문제의 해결은 온수 파이프내에 온도 센서를 부착하여, 이 온도를 실시간으로 전송하고, 수신 측에서 온수의 온도를 조절하면 된다. 본 논문에서는 보일러 내부의 순환 pump가 난방수 순환에 따른 동력을 방바닥 시멘트 몰탈 내부의 소형교류 발전기에 의해서 전기에너지를 얻어 동작하는 저전력 기반의 난방배수관 자동온도 배수장치를 제안한다. 시스템의 전원은 프로펠러 수차 방식을 사용하여 분사수 충돌 방식을 사용하였으며, MCU 모듈은 atmel 사의 ATmega8, 통신모듈을 위하여 Chipcon사의 CC1020을 사용하였다.
The PAMS data collected at four sites in Seoul metropolitan area in 2004 were analyzed using the positive matrix factorization (PMF) technique, in order to identify the possible sources and estimate their contributions to ambient VOCs. Ten sources were then resolved at Jeongdong, Bulgwang, Yangpyeong, and Seokmo, including vehicle exhaust, LPG vehicle, petroleum evaporation, coating, solvent, asphalt, LNG, Industry & heating, open burning, and biogenic source. The PMF analysis results showed that vehicle exhaust commonly contributed the largest portion of the predicted total VOCs mass concentration, more than $30\%$ at four sites. The contribution of other resolved sources were significantly different according to the characteristics of site location. In the case of Jeongdong and bulgwang located in urban area, various anthropogenic sources such as coating, solvent, asphalt, residual LPG, and petroleum evaporation contributed about $40\%$ of total VOCs mass. On the other hand, at yangpyeong and Seokmo located in rural and remote area, the portion of these anthropogenic sources was reduced to less than $30\%$ and the contribution of natural sources including open burning and biogenic source clearly observed. These results were considerably corresponding to the emission inventory investigated in this region.
A water-source heat pump system has been developed for cooling and heating of a green house on the waterfront in Jinju. In order to supply a heat source/sink of water in alluvium aquifer to the heat pump system, the riverbank filtration facility (two pumping wells and one recharge well) for water intake and injection has been constructed. To pump and recharge water sufficiently, the geometric design such as depth and diameter for the wells have been completed, and details of the well such as slot size and length of the screen and filter pack size have been designed based on the practical and theoretical design method including D30 technique. For the investigation of the hydrogeological characteristics, step-drawdown test, long-term pumping test, and recovery test have been carried out for two developed pumping wells. Step-drawdown test has been performed on 4 step flowrates of 150, 300, 450, $600m^3$/day for 1 hour, and long-term pumping test on flowrate of $500m^3$/day for 24 hours, and recovery test for 6 hours. Since the underground water filtrated by riverbank is flowing smoothly into the well, the water level goes down slightly for the long-term test. Consequently, the stable pumping flowrate for two pumping well has been predicted at least over $1,647m^3$/day which is larger than the flowrate of $1,000m^3$/day for a 60 RT heat pump system.
Researches on unused energy are being continued because of the limited fossil fuel and the destruction of environment. Therefore this study was peformed as follows. The collectable amount of exhausted heat for an air-conditioning was calculated by the subway thermal environment prediction program. And the electric power needed by conventional heat source equipments was compared with one by unused heat source equipments when the exhausted heat was used by heat pump in heating and hot water supplying. The results are summarized as follows; 1) Forced ventilation should be conducted to keep optimal temperature in subway tunnel in summer as well as in winter. According to the simulation, temperature in tunnel was higher than that on the ground in summer when the forced ventilation was conducted only in winter. 2) Ventilating time should be calculated out to the optimal condition for not only saving power of ventilation fan but reusing exhausted heat. By the simulation, it is certain that the exhausted heat should be eliminated in air-conditioning time. 3) The use of exhausted heat source heat pump could save 8% of electric power per hour in comparison with existing heat pump. It was based on a present heat generation and traffic for ventilating time of general air-conditioning, but could be different by ventilating time. 4) As the traffic increases up to 1.5 or 2 times, electric power consumption of the conventional heat pump increases to 11% or 13.5% per mean hour in comparison with that of the exhausted heat source heat pump, though all-day ventilation.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.