• 제목/요약/키워드: Heating source

검색결과 901건 처리시간 0.026초

PWM 전류제어와 펠티어 소자를 이용한 알루미늄 판의 온도 제어 (Temperature Control of the Aluminum Plate with Pottier Module by PWM Current Control)

  • 방두열;권대규;이성철
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2005년도 추계학술대회 논문집
    • /
    • pp.897-900
    • /
    • 2005
  • This paper presents temperature control of aluminum plate using Peltier module. As one of the thermoelectric effect, Peltier effect is heat pumping phenomena by electric energy. So if current is charged to Peltier module, it absorbs heat from low temperature side and emits heat to high temperature side. In this experiment, Peltier module is used to control the temperature of small aluminum plate with heating and cooling ability of Peltier module with current control and fan On/OFF control. And current control of Peltier module was accomplished by PWM method. As a results of experiments, it takes about 125sec to control temperature of aluminium plate between $30^{\circ}C\;and\;70^{\circ}C$ and about 70sec between $40^{\circ}C\;and\;60^{\circ}C$, in ambient temperature $29^{\circ}C$ while operating cooling fan only while cooling duration. Future aim is to realize more rapid temperature control and develop SMHA(special metal hydride actuator) by using Peltier module as a heating and cooling source.

  • PDF

수평형 지중열교환기를 이용한 건물일체형 지열시스템의 도입타당성 분석 (The feasibility study for the building integrated geothermal system using the horizontal heat exchanger)

  • 채호병;남유진;윤성훈
    • 한국태양에너지학회 논문집
    • /
    • 제35권1호
    • /
    • pp.81-87
    • /
    • 2015
  • Recently, in order to prevent increasing energy usages in the international community, many countries have attempted to develop the innovative renewable energy systems. Among the renewable energy systems, Ground source heat pump(GSHP) system which supply the heating, cooling and hot water in the building has been attracted by its stability of heat production and high efficiency. However, the initial drilling costs become very expensive and the construction period takes longer the other systems, because GSHP system needs more than 100 m depth drilling. In this study, in order to reduce initial costs of the GSHP, the building integrated geothermal system using the horizontal heat exchanger was developed. The heating and cooling load in the standard housing model was calculated by a simulation and the system design capacity in the high-rise apartment was decided by the total load. Based on the system design capacity, the high-rise apartments were applied to a BIGS and vertical GSHP system and there are analyzed about initial costs. In the result, the initial cost of BIGS could reduce 24% of the initial cost of the vertical GSHP system.

압전 에너지 하베스팅을 이용한 신발용 발열 시스템 개발 (Development of Shoe-heating System based on Piezoelectric Energy Harvesting)

  • 이승진;이상웅;신희근;김기만;최성대
    • 한국기계가공학회지
    • /
    • 제18권7호
    • /
    • pp.48-55
    • /
    • 2019
  • Soldiers have been exposed to the risk of chilblains in cold winters. Recent studies have described sensors and IOT devices that use independent power sources based on piezoelectric energy harvesting. Therefore, the heated shoes with an independent power source have been developed. For the application of energy harvesting to shoes, it is necessary to develop a unique harvester by considering human gait characteristics. Energy harvesters and ceramics were designed and fabricated in this study. The performances of these harvesters and ceramics were evaluated experimentally. Then, the harvesters and ceramics with superior performance were selected and applied to the system. Thereafter, the heating and charging performance of the system was tested under real walking conditions. The results show that the developed system can generate adequate energy to charge the battery and heat the shoes.

온돌의 연탄개스유량에 관한 연구 (2) (유도연관내의 개스유동) (Study on the Flow of Briquette Gas in the Ondol Heating System (2) (Gas Flow in a Briquette Flue Tube))

  • 민만기;정재선
    • 대한설비공학회지:설비저널
    • /
    • 제4권4호
    • /
    • pp.275-284
    • /
    • 1975
  • By the experiment of a model Ondol heating system gas flow characteristics in a briquette flue tube was investigated. As a heat source electric heater was used, which renders steady flow condition of air. working fluid. It was observed that the flow augumentation may be obtained by increasing the vertial elevation of the flue tube, namely increase in the tube length or increase in the tube inclination, and the gas temperature at the tube entrance Among several factors which augument the flow rate slope of the flue tube has the most striking effect and then the temperature of gas entering the tube. Increase in length of the tube also auguments the flow but the rate of augumentation is so small that it gives little assistance to improvement of the flow The flow in a briguette flue gas does not essentially satisfy the one dimensional steady flow assumption. It is also observed that the flow begins to accompany irregular velocity fluctuation as inclination of the tube increases.

  • PDF

화재사례 및 재현실험을 통한 온도조절장치 고장 및 오동작으로 인한 전자제품 화재 메커니즘 분석 (A Study on the Analysis of Fire Mechanisms in Electronic Products due to Failure and Malfunction of Thermostats Through Fire Cases and Reproduction Experiments)

  • 이정일;임종화
    • 대한안전경영과학회지
    • /
    • 제26권1호
    • /
    • pp.31-38
    • /
    • 2024
  • In this paper, as there are many cases of fires occurring due to the failure or inoperability of the thermostat of electronic products, the purpose is to test and analyze the risks and probabilities through fire cases and reproduction experiments, and suggest countermeasures. Among electronic products, water purifiers are composed of a refrigerant system with a compressor to make cold water, a heating device to make hot water, and an electric device used as an energy source. Due to the nature of the water purifier manufacturing, these devices are subject to a lot of moisture and dust. etc. exist in large quantities and use electrical energy, so there is a possibility of fire due to short circuit in the wire, electrical abnormal overheating (tracking phenomenon) in the thermostat, electronic board, starting relay, etc., and overheating of the heating device (Band Heater). there is. Therefore, in order to prevent fires from these devices, a system to remove foreign substances inside the water purifier is necessary, the use of heat-resistant (fire-resistant) wires for electrical devices is essential, and the use of non-combustible materials (semi-combustible materials) for each part is necessary to prevent fire. The risk must be eliminated through prevention and combustion expansion prevention devices.

Dual Mode Phase-Shifted ZVS-PWM Series Load Resonant High-Frequency Inverter for Induction Heating Super Heated Steamer

  • Hisayuki Sugimura;Hidekazu Muraoka;Tarek Ahmed;Srawouth Chandhaket;Eiji Hiraki;Mutsuo Nakaoka;Lee, Hyun-Woo
    • Journal of Power Electronics
    • /
    • 제4권3호
    • /
    • pp.138-151
    • /
    • 2004
  • In this paper, a constant frequency phase shifting PWM-controlled voltage source full bridge-type series load resonant high-frequency inverter using the $4^{th}$ generation IGBT power modules is presented for innovative consumer electromagnetic induction heating applications, such as a hot water producer, steamer and super heated steamer. The bridge arm side link passive capacitive snubbers in parallel with each power semiconductor device and AC load side linked active edge inductive snubber-assisted series load resonant tank soft switching inverter with a constant frequency phase shifted PWM control scheme is evaluated and discussed on the basis of the simulation and experimental results. It is proved from a practical point of view that the series load resonant and edge resonant hybrid high-frequency inverter topology, what is called, DE class type, including the variable-power variable-frequency regulation function can expand zero voltage soft switching commutation area even under low output power setting ranges, which is more suitable and acceptable for newly developed induction heated dual pack fluid heaters. Furthermore, even the lower output power regulation mode of this high-frequency load resonant tank inverter circuit is verified so that this inverter can achieve ZVS with the aid of the single auxiliary inductor snubber.

직류 전류 이용 종양세포치료의 특성 연구 (Characterization Analyses for Direct Current Tumor Ablation)

  • 양태건;김재홍
    • 한국진공학회지
    • /
    • 제20권4호
    • /
    • pp.307-312
    • /
    • 2011
  • 정상 세포로부터 암과 같은 종양세포를 제거하는 방법으로 라디오주파수의 전자파를 이용하여 세포가 사멸되는 임계온도보다 높은 온도로 국소 가열하는 발열 치료법이 임상에서 시술되고 있다. 그러나 이 기술은 임상에서 활발히 사용되기에는 여러 가지 제약 요인이 존재한다. 본 연구에서는 교류파 대신에 미소 직류전원을 사용하여 국소부위에 열을 발생하는 안전성이 증가된 방법의 실효성을 이론적으로 입증하고자 한다. 종양세포의 형태에 따라 적당한 모양의 전극을 종양조직에 삽입하고 종양조직의 형태와 유사한 열분포를 갖도록 제어하는 기술을 개발한다. 열원은 조직 내에 삽입된 전극과 매질에 형성되는 전기장에 의한 저항열이다. 종양 조직 내에 삽입된 전극에 10 V, 20 V, 30 V를 각각 인가하고 시간에 따른 열분포를 전산모의 하였다. 결과적으로, 20 V를 전극에 인가하면 1~2 분 이내에 버섯모양의 등온도 분포를 갖으며 세포를 고사시키는 온도 이상의 치료영역이 형성됨을 보였다. 4개의 전극에 대칭적인 전위를 인가하고 $50^{\circ}C$ 이상의 온도 분포를 암 조직의 모양과 유사하게 분포하도록 조절하여 효과적인 치료를 수행 할 수 있는 가능성을 제시하고자 한다.

초음파 서모그라피를 이용한 빠른 PCB 결함 검출 (Fast Defect Detection of PCB using Ultrasound Thermography)

  • 조재완;서용칠;정승호;김승호;정현규
    • 대한전기학회논문지:시스템및제어부문D
    • /
    • 제55권2호
    • /
    • pp.68-71
    • /
    • 2006
  • Active thermography has been used for several years in the field of remote non-destructive testing. It provides thermal images for remote detection and imaging of damages. Also, it is based on propagation and reflection of thermal waves which are launched from the surface into the inspected component by absorption of modulated radiation. For energy deposition, it use external heat sources (e.g., halogen lamp or convective heating) or internal heat generation (e.g., microwaves, eddy current, or elastic wave). Among the external heat sources, the ultrasound is generally used for energy deposition because of defect selective heating up. The heat source generating a thermal wave is provided by the defect itself due to the attenuation of amplitude modulated ultrasound. A defect causes locally enhanced losses and consequently selective heating up. Therefore amplitude modulation of the injected ultrasonic wave turns a defect into a thermal wave transmitter whose signal is detected at the surface by thermal infrared camera. This way ultrasound thermography(UT) allows for selective defect detection which enhances the probability of defect detection in the presence of complicated intact structures. In this paper the applicability of UT for fast defect detection is described. Examples are presented showing the detection of defects in PCB material. Measurements are performed on various kinds of typical defects in PCB materials (both Cu metal and non-metal epoxy). The obtained thermal image reveals area of defect in row of thick epoxy material and PCB.

Peltier Heating-Assisted Low Temperature Plasma Ionization for Ambient Mass Spectrometry

  • Lee, Hyoung Jun;Oh, Ji-Seon;Heo, Sung Woo;Moon, Jeong Hee;Kim, Jeong-hoon;Park, Sung Goo;Park, Byoung Chul;Kweon, Gi Ryang;Yim, Yong-Hyeon
    • Mass Spectrometry Letters
    • /
    • 제6권3호
    • /
    • pp.71-74
    • /
    • 2015
  • Low temperature plasma (LTP) ionization mass spectrometry (MS) is one of the widely used ambient analysis methods which allows soft-ionization and rapid analysis of samples in ambient condition with minimal or no sample preparation. One of the major advantages of LTP MS is selective analysis of low-molecular weight, volatile and low- to medium-polarity analytes in a sample. On the contrary, the selectivity for particular class of compound also implies its limitation in general analysis. One of the critical factors limiting LTP ionization efficiency is poor desorption of analytes with low volatility. In this study, a home-built LTP ionization source with Peltier heating sample stage was constructed to enhance desorption and ionization efficiencies of analytes in a sample and its performance was evaluated using standard mixture containing fatty acid ethyl esters (FAEEs). It was also used to reproduce the previous bacterial identification experiment using pattern-recognition for FAEEs. Our result indicates, however, that the bacterial differentiation from FAEE pattern recognition using LTP ionization MS still has many limitations.

복합열병합발전소에 적용된 유기랭킨사이클의 성능 및 경제성 평가 (Evaluation of Performance and Economics of Organic Rankine Cycle Integrated into Combined Cycle Cogeneration Plant)

  • 김인섭;김창민;김동섭;이종준
    • 한국유체기계학회 논문집
    • /
    • 제20권1호
    • /
    • pp.41-47
    • /
    • 2017
  • This study aimed to analyze organic Rankine cycle(ORC) which recovers discarded heat from a gas turbine based combined cycle cogeneration(CC-cogen) plant in terms of both performance and economics. The nominal electric power of the CC-cogen plant is around $120MW_e$, and heat for district heating is $153MW_{th}$. The major purpose of this study is to compare various options in selecting heat source of the ORC. Three heat sources were compared. Case 1 uses the exhaust gas from the HRSG, which is purely wasted to environment in normal plant operation without ORC. Case 2 also uses the exhaust gas from the HRSG. On the other hand, in this case, the DH economizer, which is located at the end of the HRSG, does not operate. Case 3 generates power using some of the district heating water which is supplied to consumers. The estimated ORC power generation ranges between 0.3 to 2.3% of the power generation capacity of the CC-cogen plant. Overall, Case 3 is evaluated to be better than other two options in terms of system design flexibility and power generation capacity.