• Title/Summary/Keyword: Heating source

Search Result 897, Processing Time 0.032 seconds

An Analysis of Simulation Model for Smelting Reduction Process of Waste Containing Iron Oxide (함철 폐기물의 용융환원 공정에 관한 분석연구)

  • Dong-Joon Min
    • Resources Recycling
    • /
    • v.5 no.4
    • /
    • pp.17-24
    • /
    • 1996
  • The computer simulation model was established to verify the applicability of smelting reduction concept to treatment of industrial wastes which becomes issue on the enviromental and recycling view point. Computer simulation model provides as following results. The increase of post combustion ratio(PCR) and heat transfer efficiency of PC energy(HTE) is effective ways to save energy. But, in order to increase PCR, recovery efficiency of post combustion energy(HTE) have to be higher than 85% HTE considering refractory life and saving energy together. Coke is most useful fuel source because it shows lowest dependence of PCR and low hydrogen content. The quality of hot metal of current process would be expected to the similar level with that of blast furnace. The utilization of scrap and Al dross can be also possible to maximize the advantages of current process which is high temperature and chemical dilution with hot metal and slag. In case of scrap, energy consumption was slightly increases because of heating up energy of scrap. Consquently, current process concept provides the possibility of intergrating recycles of industrial wastes materials such as EAF slag, coke oven dust, life terminated acidic refractory, aluminium dross and scrap by smelting reduction process.

  • PDF

The Qualities of Molded Charcoal for Kindling Molded-Coal-Briquette (구멍탄착화용 성형탄의 품질)

  • Jo Jae-myeong;Kim Young-nyon;Kim Suk-goo;Cho Sung-taig;Kong Young-to
    • Journal of Korea Foresty Energy
    • /
    • v.1 no.2
    • /
    • pp.28-33
    • /
    • 1981
  • To survey the present qualities of the molded and to present the base line of qualities in manufacture, the charcoal collected at 27 makers through the nation were examined. The molded charcoal examined in this paper, which is made by carbonization and molding of sawdusts from wood industries, is widely used to kindle holed-coal-briquette. The holed-coal-briquette is utilized in cooking and heating as primary energy source of ordinary households in this country. The average qualities of molded charcoal was as follows; ash content 13.95$\%$, weight 184.6g, density 0.47, time of kindling holed-coal-briquette 65.4 min., calorie 5,790 kcal/kg. The ten makers produced inferior qualities, that was 37 per cent of the 27 makers examined. The base line of qualities of molded charcoal was defined as follows; ash content below 17$\%$, weight above 175 g, falling strength above 300 mm, calorie above 5,500 kcal/kg.

  • PDF

Experimental exergy assessment of ground source heat pump system

  • Ahmad, Saif Nawaz;Prakasha, Om
    • Advances in Energy Research
    • /
    • v.6 no.2
    • /
    • pp.161-172
    • /
    • 2019
  • The principal intention of this experimental work is to confer upon the exergy study of GSHP associated with horizontal earth heat exchanger for space heating. The exergy analysis recognizes the assessment of the tendency of various energy flows and quantifies the extensive impression of inefficiencies in the system and its components. Consequently, this study intends to provide the enlightenment for well interpretation of exergy concept for GSHP. This GSHP system is composed of heat pump cycle, earth heat exchanger cycle and fan coil cycle. All the required data were measured and recorded when the experimental set up run at steady state and average of the measured data were used for exergy investigation purpose. In this study the rate at which exergy destructed at all the subsystems and system has been estimated using the analytical expression. The overall rational exergetic efficiency of the GSHP system was evaluated for estimating its effectiveness. Hence, we draw the exergy flow diagram by using the various calculated results. The result shows that in the whole system the maximum exergy destruction rate component was compressor and minimum exergy flow component was earth heat exchanger. Consequently, compressor and earth heat exchanger need to be pay more attention.

Electrical Resistance of Mo-doped $VO_2$ Films Coated on Graphite Conductive Plates by a Sol-gel Method (몰리브덴이 첨가된 이산화바나듐으로 표면처리한 탄소계 전도성판의 전기저항특성)

  • Choi, Won-Gyu;Jung, Hye-Mi;Lee, Jong-Hyun;Im, Se-Joon;Um, Suk-Kee
    • Proceedings of the KSME Conference
    • /
    • 2008.11b
    • /
    • pp.2007-2010
    • /
    • 2008
  • Vanadium pentoxide ($V_2O_5$) powder was prepared and mixed with Molybdenum Oxides ($MoM_3$) to form Mo-doped and -undoped $VO_2$ films by a sol-gel method on graphite conductive substrates. X-Ray diffraction (XRD) and scanning electron microscopy (SEM) was used to investigate the chemical compositions and microstructures of the Mo-doped and -undoped $VO_2$ films. The variation of electrical resistance was measured as a function of temperature and stoichiometric composition between vanadium and molybdenum. In this study, it was found that Mo-doped and -undoped $VO_2$ shows the typical negative temperature coefficient (NTC) behavior. As the amount of the molybdenum increases, the electrical resistance of Modoped $VO_2$ film gets reduced under the transition temperature and a linear decrease in the transition temperature is observed. From these experimental results, we can conclude that the electrical resistance behavior with temperature change of $VO_2$ films can be utilized as a self-heating source with the electrical current flowing through the graphite substrate.

  • PDF

A Study on the Characteristics of the Earth Heat Extraction Using Termosyphon (Termosyphon의 지열채열 성능에 관한 고찰)

  • Shin, H.J.;Seo, J.Y.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.5 no.3
    • /
    • pp.226-233
    • /
    • 1993
  • Thermosyphons are simple devices that can passively transport thermal energy over relatively large distance with little temperature degradation. Especially, the thermosyphon system requires no costly energy input and is completely maintenance free. These attributes permit the use of low grade thermal energy for thermal control of structures including the stabilization of highway foundations. This paper presents the experimental results of the snow melting system in which thermosyphon was utilized to ransfer the earth energy to the pavement to remove snow and ice. The test facility, three earth heated and one unheated test panels, is designed to investigate the variables associated with removing snow and ice from pavement surfaces. The results of these test show that the earth heated panel surface temperature is higher $2{\sim}6^{\circ}C$ than unheated panel when the ambient air temperature is $-7^{\circ}C$. The thermal performance of this earth source thermosyphon system for road heating showed that there was no snow on the heated test panels when the snowfall was 5cm average for the region.

  • PDF

Analysis of Economics through Control Method of Heat Source Equipment in Seasonal Air conditioning Building

  • Park, Yool;Kim, Samuel;Jung, Soon-Sung
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.11 no.4
    • /
    • pp.209-217
    • /
    • 2003
  • The term “energy saving is economical” is appropriate for the national view point and for design and assessment of one system, but not appropriate when choosing the system by comparing alternative systems in the early design step. Sometimes, non-energy saving system is more economical than energy saving system because of the price of electricity, gas or oil, which are used for operating the air conditioning system. Therefore, when designing a system, we should consider the efficient alternatives through economic assessment of energy saving method. However, research on non-operating number control of the system is not sufficient because it is more common to use operating number control of the system for most economic assessment of air conditioning systems. For this reason, this research can provide the economic operating number control method as basic design data. The data obtained through analysis of life cycle cost based on amount of yearly energy use, are produced by system simulation of HASP/ACLD/8501 and HASP/ACSS/8502 for six alternative heating$.$cooling systems based on seasonal air conditioning system, which is widely used for medium and large size office buildings in Busan.

An Analysis on the Energy Consumption Unit of the Public buildings in Daegu (대구시 공공건축물의 에너지 소비 원단위에 관한 연구)

  • Choe, Jeong-Hui;Kim, Ju-Young;Hong, Won-Hwa
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2005.11a
    • /
    • pp.319-322
    • /
    • 2005
  • An energy problem has become one of the many Problems awaiting solution to human society. Energy needs to support not only industry, but also building in city. The types of residential building, office building and public building account for much proportion among the totally amount used energy. A public institution shows a fine example for an energy conservation in the present situation. But, the amount used energy of electricity, air-conditioning and heating is different from a building use and condition. Because the building data of the energy consumption by a load is insufficient, it is unable to select a proper energy source. According to this study, it analyzed an energy load by each building that had investigated the actual conditions of energy consumption about public buildings in Daegu City. In order to plan the efficient energy use both existing buildings and new buildings, this study will present the efficient energy use plan, which has operated to new buildings of a public institution, at present.

  • PDF

Analysis of Decontamination from Concrete by Microwave Power

  • Zi, Goang-Seup
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2004.11a
    • /
    • pp.603-608
    • /
    • 2004
  • The paper analyzes a scheme of decontamination of radionuclides from concrete structures, in which rapid microwave heating is used to spall off a thin contaminated surface layer. The analysis is split in two parts: (1) The hygrothermal part of the problem, which consists in calculating the evolution of the temperature and pore pressure fields, and (2) the fracturing part, which consists in predicting the stresses, deformations and fracturing. The rate of the distributed source of heat due to microwaves in concrete is calculated on the basis of the standing wave normally incident to the concrete wall with averaging over both the time period and the wavelength because of the very short time period of microwaves compared to the period of temperature waves and the heterogeneity of concrete. The reinforcing bars parallel to the surface arc treated as a smeared steel layer. The microplane model M4 is used as the constitutive model for nonlinear deformation and distributed fracturing of concrete. The aim of this study is to determine the required microwave power and predict whether and when the contaminated surface layer of concrete spalls off. The effects of wall thickness, reinforcing bars, microwave frequencies and power are studied numerically. As a byproduct of this analysis, the mechanism of spalling of rapidly heated concrete is clarified.

  • PDF

Study on construction method of horizontal ground heat pump system using the building structure (건물구조체를 이용한 수평형 지열시스템의 시공법에 관한 연구)

  • Chae, Ho-Byung;Nam, Yujin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2013.11a
    • /
    • pp.139-140
    • /
    • 2013
  • Ground source heat pump systems can achieve the energy saving of building and reduce CO2 emission by utilizing stable ground temperature. However, they have many barriers such as high cost of installation, incompletion of design tool, lack of recognition as heating and cooling systems. In order to solve the problems, the building integrated geothermal system (BIGS) developed by several researches which use building foundation as a heat exchanger. In order to establish the optimum design tool of BIGS with the horizontal heat exchanger, the prediction method of ground heat exchange rate developed with numerical simulation model. In this study, the economic analysis for BIGS was conducted based on simulation results and the optimal design method was suggested. As a result, it was found that the case of 32 A, piping space 0.3 m, piping deep 0.5 m and flow rate 9.52 L/min was the best case as 50.1 W/m2 of heat exchange rate. In this case the initial cost was reduced to 115 million won.

  • PDF

Theoretical Study on the Performance in a Solar-Geothermal Hybrid R22 Heat Pump During Winter Season according to Heat Source Temperature (열원의 온도변화에 따른 겨울철 태양열-지열 하이브리드 R22 열펌프의 성능에 관한 해석적 연구)

  • Kang, Byun;Cho, Honghyun
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.8 no.4
    • /
    • pp.24-31
    • /
    • 2012
  • The Solar and geothermal energy have many advantage like low cost, non-toxic, and unlimited. But those the have very low energy efficiency. In this study, the theoretical study of performance in a sola-geothermal hybrid heat pump with operating conditions has carried out. As a result, as the solar radiation increases from 1 $MJ/m^2$ to 20 $MJ/m^2$, the heat pump operating time decreases by 19.5% from 18 times to 14.5 times and the heat pump heat decreases by 23%. Besides, the heating COP increases by 21.4% when the evaporator inlet temperature increases from $11^{\circ}C$ to $19^{\circ}C$. By adapting the geothermal system into a solar hybrid R22 heat pump, the system performance and reliability increases significantly for variable operating conditions during winter season.