• Title/Summary/Keyword: Heating price

Search Result 101, Processing Time 0.048 seconds

Study on Application and Economic Evaluation of New Insulation Material to Confront High Oil Price: Focus on an Apartment (고유가 대응을 위한 신단열재 적용과 경제성평가 연구 : 공동주택을 중심으로)

  • Hyun, Jong-Hun;Kim, Ji-Yeon;Park, Hyo-soon;Choi, Moo-Hyuck
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.20 no.11
    • /
    • pp.746-751
    • /
    • 2008
  • The best plan to reduce the building energy consumption is that the insulation performance should be improved because the insulation and airtight of building envelopes have an effect on the energy consumption basically. New insulation materials, which have the high performance and are above insulation standard, have been developed steadily. Because there are not studies on the building energy rating system and economic evaluation considering new insulation materials, these matters should be studied. In result alternatives, which applied 6 high performance material each, reduce the annual heating energy and raise the building energy rating. Applying the vacuum insulation material(Case 1, 2) and vacuum or triple glazing can retrieves the investment with $120 and $140$\sim$150 per barrel each.

Thermal performance evaluation of Temperable Low-e glass window through Heating Energy consumption Analysis (난방에너지 사용량 분석을 통한 후강화 로이유리 창호의 단열성능 평가)

  • Jang, Cheol-Yong;Kim, Jeong-Gook;Ahn, Byung-Lip;Kim, Jun-Sup;Haan, Chan-Hoon
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2012.03a
    • /
    • pp.200-205
    • /
    • 2012
  • In the high oil price age, intensification of energy efficiency promotion in the building sector is required. Windows are dominating in large percent of whole building loads, and are regarding as the primary target of energy efficiency. In this study, in order to reduce heat loss of buildings, we investigate the thermal performance properties of Temperable Low-e glazing coated Ag membrane that has high electrical conductivity. The Temperable Low-e glazing windows has high insulation and shading properties, and it has strength that can supply various product which consumers want. In order to evaluate thermal performance of temperable windows, we install single low-e windows and double low-e windows in the experimental chamber and analysis the comparison heating energy consumption between single and double Low-e glazing windows. performance evaluation was conducted.

  • PDF

Empirical Research on Application of ICT for Reduction of Energy Consumption of Hospital Buildings (ICT를 활용한 병원건물의 에너지 절감방안 연구)

  • Lee, Junghwan;Han, Youngdo;Kim, Dongwook
    • The Journal of the Korea Contents Association
    • /
    • v.18 no.1
    • /
    • pp.422-430
    • /
    • 2018
  • Increase in oil prices and building energy consumption has been a great burden for Korea which has significant energy dependence on foreign energy sources. In this context, reduction of building energy consumption, which comprises 40% of total energy consumption, is a very important issue. This research therefore empirically analyzed a hospital "P" that implemented ICT-based energy consumption and cost reduction initiative. The hospital first replaced existing water absorber for heating/cooling air and boiler for heating water with water heat storage heat pump system. This was accompanied by subscribing to different electricity price plans to maximize cost reduction. Secondly, the hospital additionally applied ICT-based optimized control algorithm that considers surrounding factors (external temperature, changes in energy demand). The analysis of these mechanisms indicate that the ICT-based energy consumption and cost reduction initiative for hospitals can reduce energy consumption by 53.6% with replacement of low-efficiency equipment and additionally by 18.2% with optimized control algorithm. The mechanisms will provide energy consumption reduction opportunities for other hospitals and buildings with high energy consumption.

Comparative Analysis on the Economic Effects of Integrated-Energy and Manufactured Gas Supply Sectors (집단에너지 부문과 도시가스 부문의 경제적 파급효과 비교분석)

  • Park, So-Yeon;Lee, Kyoung-Sil;Yoo, Seung-Hoon
    • Journal of Energy Engineering
    • /
    • v.23 no.2
    • /
    • pp.83-92
    • /
    • 2014
  • This paper attempts to conduct a comparative analysis on the economic effects of integrated-energy and manufactured gas supply sectors. To this end, an input-output (I-O) analysis is applied using most recently published 2011 I-O table. In particular, the two sectors are specified as exogeneous to identify the economic effects on own and other sectors. Production-inducing effect, value-added creation effect, and employment-inducing effect are quantified based on demand-driven model. Supply shortage effect and price pervasive effect are analyzed employing supply-driven model and Leontief price model, respectively. The results show that production-inducing effect, value-added creation effect, and employment-inducing effect of integrated-energy and manufactured gas supply sectors are estimated to be 1.5461 vs. 1.0297, 0.4759 vs. 0.1941, and 2.2885 vs. 0.4053 respectively. Price pervasive effects of the 10% increase in integrated-energy and manufactured gas supply sectors are computed to be 0.0127% and 0.1585%, respectively. This information can be utilized in forecasting the economic effects of introducing integrated-energy or manufactured gas as a heating source and the impacts of a rise in price of integrated-energy or manufactured gas on price level of other sectors.

An Estimation of the Acreage Response Function of Major Vegetables in Gyeongnam Province (경남지역 주요 채소류 재배면적 반응함수 추정)

  • Cho, Jae-Hwan
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.22 no.1
    • /
    • pp.131-137
    • /
    • 2021
  • This study estimated acreage response functions for greenhouse paprika, greenhouse strawberry, open-land garlic, and open-land spinach by using Gyeongsangnamdo agricultural income data. The results show that the cultivation area for greenhouse paprika increased because the agricultural management costs decreased, and the risk of price volatility was relatively low. On the other hand, the cultivation area for greenhouse strawberries decreased due to increasing agricultural management costs and the greater risk of price volatility. In the case of open-land garlic and spinach, the cultivation area remained stagnant due to the greater risk of price volatility, despite increasing agricultural revenue. We derived several policy implications from our results. The risk of price volatility in agricultural products is greater for crops grown on land rather than crops grown in greenhouses. Therefore, the local government needs to adopt the "agricultural revenue guarantee insurance" in preference to crops grown on land rather than crops grown in greenhouses. On the other hand, in the case of greenhouse crops, agricultural management costs are very high. Thus, local government should focus on replacing old facilities and supplying smart-farm facilities that reduce agricultural management costs such as heating costs.

Thermal Storage Characteristics of Low Temperature Phase Change Materials for Thermal Environmental Control of Protected Cultivation System (시설 농업의 열환경조절을 위한 저온 상변화 물질의 축열 특성)

  • 송현갑;유영선;노정근;박종길
    • Journal of Bio-Environment Control
    • /
    • v.6 no.3
    • /
    • pp.216-224
    • /
    • 1997
  • In the recent 10 years the protected cultivation area in Korea has been increased rapidly, and now it is very important issue to develop the heating and cooling system using the renewable energy, because the greenhouse heating and cooling cost is increased with the fossil fuel price rises. Actually the development of the cooling system is more difficult than that of the heating system, since the cooling load of greenhouse in the summer season is 2―3 times larger than the heating load in the winter season. In this study low temperature phase change materials (LTPCM) for the cold storage system were selected and developed. The theoretical and experimental analysis of thermal characteristics of LTPCM makes it possible to control the phase change temperature and stabilize the thermo-physical properties. LTPCM developed in this study has good advantages to be used as the cold storage not only for the house and working space in factory but also for the cold storage of agricultural and live-stock products.

  • PDF

Study on the International Climatic Testing Standard for Passenger Car (철도차량의 국제 기후환경 시험규격의 수행방안 연구)

  • Yoon, Young-Kwan;Cho, Young-Min;Choi, Jin-Sik;Jung, Woo-Sung;Kwon, Soon-Bark;Park, Duck-Shin
    • Proceedings of the KSR Conference
    • /
    • 2011.10a
    • /
    • pp.1327-1334
    • /
    • 2011
  • subway has became citizen's feet which can transport over 24 million people since the era of high oil price started. Because the request of passengers for more comfortable thermal comfort is drastically increasing, the importance of comfortable environment in the passenger car is more stressed. This paper suggests an indicator whether railroad car is fitted with suitable cooling and heating equipment by applying the international climatic testing method, UIC 553, 553-1. Specified ambient temperature, humidity, solar irradiation condition, as well as extreme outside condition, can be achieved by using an environmental chamber. The change temperature and humidity in the passenger space can be monitored to judge if the passenger room is nicely air-conditioned.

  • PDF

Estimation of Load Pattern due to Midnight Power Equipment (겨울철 심야기기 사용에 따른 부하사용패턴 추정)

  • Kim, C.S.;Rhee, C.H.;Jin, B.M.;Baek, Y.S.
    • Proceedings of the KIEE Conference
    • /
    • 2001.11b
    • /
    • pp.48-50
    • /
    • 2001
  • Recently, electric heating using midnight power has brought a rapid increase. due to a rise of oil price and a low tariff of midnight power. Therefore, the increase of midnight power use has much influenced on midnight load pattern. This paper estimates the load pattern due to midnight power equipments, analyzes the influence of the spread of midnight power equipments on midnight load and suggests reasonable spread level of equipments.

  • PDF

Analysis of Load Pattern and Generation Cost in Midnight Power Services (심야전력 보급증가와 부하패턴 및 발전비용의 영향)

  • Kim, C.S.;Rhee, C.H.;Park, J.J.
    • Proceedings of the KIEE Conference
    • /
    • 2001.07a
    • /
    • pp.547-549
    • /
    • 2001
  • Recently, heating using oil and gas has been continuously replaced by that using midnight power in home, due to increase of oil price. Therefore, midnight power apparatus has been more and more spreading. However, cost of midnight power services is increasing because high fuel cost of generation facilities by existing power generation mix are charge of midnight power services. This paper analyzes trends about rapidly increasing midnight power in winter, and evaluate load pattern and supply cost of midnight power. Also, this study proposes rate direction of midnight power according to introduction of competitiveness system with B/C evaluation of midnight power cost.

  • PDF

The Field Test of Heat Pump Cooling & Heating System using the water-purifying device (수도시설을 이용한 지열냉난방시스템의 실증연구)

  • Hwang, Ki-Sup;Jung, Woo-Sung;Ahn, Young-Sub
    • Proceedings of the SAREK Conference
    • /
    • 2007.11a
    • /
    • pp.629-634
    • /
    • 2007
  • The Alternative energy has lately attracted considerable attention due to the high oil price and environment problem. In this study, field test of facility for using the geothermal energy source from water-purifying device was constructed and monitoring devices are installed to estimate the efficiency of this system. Initial installation cost can be saved efficiently by connecting a heat pump system into the existing pumping well in site of water-purifying in Cheongju. One set of monitoring results during summer was presented and analyzed.

  • PDF