• Title/Summary/Keyword: Heating mode

Search Result 335, Processing Time 0.026 seconds

Digital Variable Structure Control for a Hot Water Heating System (온수나방 시스템의 디지틀 가변구조제어)

  • 안병천;장효환
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.8 no.1
    • /
    • pp.65-75
    • /
    • 1996
  • A pilot plant, which is simplified the hot water heating control system of a large scale residential building, is used to investigate the effects of control methods and operating conditions on the system performance and to compare control characteristics. Digital variable structure controller(DVSC) and digital PI controller are implemented to control the speed of the circulating pump for the pilot plant using PC. For the DVSC, a control algorithm is suggested, which using a nonlinear sliding surface and a PID sliding surface outside and inside of output error boundary layer, respectively. Smith predictor algorithm is used for the compensation of long dead time. The suggested DVSC yields improved control performance compared with existing DVSC using linear sliding surface only. the system responses with the suggested DVSC shows good responses without overshoot for various operating conditions and robust under external disturbances compared with digital PI controller.

  • PDF

A Novel Switched Capacitor Lossless Inductors Quasi-Resonant Snubber Assisted ZCS PWM High Frequency Series Load Resonant Inverter

  • Fathy, Khairy;Kang, Tae-Kyung;Kwon, Soon-Kurl;Suh, Ki-Young;Lee, Hyun-Woo;Nakaoka, Mutsuo
    • Proceedings of the KIEE Conference
    • /
    • 2005.10c
    • /
    • pp.169-171
    • /
    • 2005
  • In this paper, a novel type of auxiliary switched capacitor assisted edge resonant soft switching PWM series load resonant high frequency inverter with two auxiliary edge resonant lossless inductor snubbers is proposed for small consumer induction heating appliances. The operation principle of this high frequency inverter is described using the switching mode equivalent circuits. The practical effectiveness of the newly proposed soft switching inverter are discussed as compared with the conventional soft switching high frequency inverters based on simulation and experimental results from an application point of view.

  • PDF

Mode Size Converter based on Muitimode Fiber Taper (다중모드 광섬유 테이퍼를 이용한 모드 크기 변환기)

  • Kim, Kwang-Taek;Park, Kiu-Ha;Hyun, Woong-Keun;Jung, Yong-Min;Lee, Byeong-Ha
    • Korean Journal of Optics and Photonics
    • /
    • v.18 no.4
    • /
    • pp.280-285
    • /
    • 2007
  • Based on the multimode fiber taper, a mode size converter for effective optical beam coupling between laser and optical fiber or between the two different optical fibers has been proposed and demonstrated. The device has a multimode input end and a single mode output end. The influence of various parameters, including device structure and launching conditions, on the coupling efficiency has been theoretically analyzed. The theoretical results revealed that the gaussian beam can be coupled into a single mode fiber without considerable insertion loss. The proposed multimode fiber taper has been fabricated using heating and pulling equipment incorporating two micro-torches. Experimental results showed that an optical beam with $50\;{\mu}m$ of large beam size was effectively coupled into single mode fiber through the multimode fiber taper. The insertion loss of the device was 1.3 dB.

A Development of Test Method on the Energy Consumption Efficiency of Domestic Gas Boiler below 70 kW (70 kW 이하 가정용 가스보일러 에너지소비효율 실험방법 개발)

  • Park, Chanil;Kim, Laehyun
    • Journal of Energy Engineering
    • /
    • v.25 no.3
    • /
    • pp.73-82
    • /
    • 2016
  • The energy consumption efficiency in a variety of operational test mode was considered for domestic gas boiler below 70 kW. The energy efficiency test carried out in the experimental conditions similar to the actual operation status was analyzed and compared with the current Korean efficiency test method. Four types of test modes for each boiler(Non-condensing and condensing boiler) were carried out in the condition of laboratory mode(full load, steady state) and actual operating mode. Futhermore divided into two operational status for each of these, it was applied by maximum gas consumption and consumer sales conditions. Test equipment has the function referred to gas boiler standards, such as KS or European standard EN. The equipment should be continuously measured and record the measuring factors which are the flow volume of gas and water, laboratory temperature, water flow volume for heating, return water volume after heating and quantity of the exhaust gases(CO, NO, $NO_2$). The experimental results were found that non-condensing boiler efficiency of laboratory mode is about 10% higher than that of actual mode. In case of condensing boiler, the efficiency of laboratory condition is about 20% higher than that of the actual using conditions. I suggest that the government will gradually take the efficiency test method considering the actual conditions.

New harmonic drop device develop take advantage of Zig-zag TR line and Open Delta mode (Zig-zag 결선 및 Open Delta 방식을 이용한 새로운 고조파 저감장치의 개발)

  • Yoo, Sang-Bong;Lee, Sung-Ho;Kim, Gi-Sung
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2004.11a
    • /
    • pp.101-104
    • /
    • 2004
  • The past harmonic filter was reactor and Zig-zag. However neutral reactor over heating become an issue. If take advantage of Zig-zag TR line and Neutral line Open Delta mode TR to disappear TR sounds and harmonic by the help of experiments. The disappear harmonic have not relation of neutral line electric current quantity

  • PDF

Tunable AC Mode Hotwire Anemometry (교류방식 열선 유속 측정법 개발)

  • Chung, Won-Seok;Kwon, Oh-Myoung;Choi, Du-Seon;Lee, Joon-Sik
    • Proceedings of the KSME Conference
    • /
    • 2003.04a
    • /
    • pp.1337-1341
    • /
    • 2003
  • This paper suggests and demonstrates a novel flow measurement technique, tunable AC mode hotwire anemometry that allows simple integration, robust measurement, and extremely high accuracy. The principle and simple theoretical analysis of the technique are shown. To find the optimal frequency at which the phase lag becomes most sensitive to flow speed change, the phase lag was measured scanning the heating frequency from 1 to 100 Hz, while the flow speed of ethanol was increased stepwise from 0 to 10 mm/s. To optimize the sensitivity of technique, the periodic thermal characteristic of the hotwire should be understood and is currently under study.

  • PDF

A study on Flow Characteristic inside Passenger's Compartment under Recirculation Cool vent mode using CFX (CFX를 이용한 내부순환모드에서의 자동차 내부 유동특성 연구)

  • Kim, Yoon-Kee;Yang, Jang-Sik;Kim, Kyung-Chun;Ji, Ho-Seong
    • Journal of the Korean Society of Visualization
    • /
    • v.8 no.1
    • /
    • pp.25-30
    • /
    • 2010
  • The flow characteristics under recirculation cool vent mode is numerically studied using commercial fluid dynamic code(CFX). For the reliable analysis, real vehicle and human FE model is employed in grid generation process. The geometrical location and shape of panel vent, and exhaust vent is set as that of real vehicle model. The flowrate of the working fluid is determined as 330CMH which is equivalent to 70 percent of maximum capacity of HVAC system. The high velocity regions are formed around 4 each panel vent. Because of the non-symmetrically located exhaust, non-uniform flow and partial backflow near the door trim is observed. Streaklines start from each panel vent show the flow pattern of the airflow in the passenger's compartment very well.

Simulation of Submicron MOSFET Using Hydrodynamic Model (Hydrodynamic model을 이용한 Submicron MOSFET의 Simulation)

  • 김충원;한백형;김경석
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.30A no.11
    • /
    • pp.122-131
    • /
    • 1993
  • In this paper, we have developed a submicron Si MOSFET simulator, which is physically based on the hydrodynamic energy transport mode. The simulator was used to investigate the nonstationary transport effects and the transient phenomena in submicron Si MOSFET's. It is found that the velocity overshoot and the carrier heating are dominant transport mechanism near the drain end of the channel and the transient phenomena is more retained in a long channel MOSFET.

  • PDF

Thermal Degradation Kinetics of Tocopherols during Heating without Oxygen (무산소 가열시 토코페롤의 열분해 키네틱스)

  • Chung, Hae-Young
    • The Korean Journal of Food And Nutrition
    • /
    • v.20 no.2
    • /
    • pp.120-124
    • /
    • 2007
  • The thermal degradation kinetics of alpha-, gamma- and delta-tocopherols was studied during heating at 100, 150 200 and 250$^{\circ}C$ for 5, 15, 30 and 60 min in the absence of oxygen. The tocopherols were separated by HPLC using a reversed phase ${\mu}$-Bondapak C$_{18}$-column with two kinds of elution solvent system in a gradient mode. The kinetics for degradation of ${\alpha}$-, ${\gamma}$- and ${\delta}$-tocopherols was analyzed as a function of temperatures and times. The degradation of tocopherols was described by the first-order kinetics in the absence of oxygen. The rate of tocopherols degradation was dependent on heating temperatures. The degradation rate constants for ${\alpha}$-, ${\gamma}$ and ${\delta}$-tocopherols showed an increasing trend as the heating temperature increased. The magnitude order of the experimental activation energy was ${\delta}$->${\gamma}$->${\alpha}$-tocopherol.