• 제목/요약/키워드: Heating load

검색결과 897건 처리시간 0.03초

간역잠실(簡易蠶室)의 난방부하특성(暖房負荷特性) 및 보온(保溫)커튼 설치(設置)효과에 관한 연구(硏究)(II) -보온(保溫)커튼의 열(熱) 절감(節減) 효과(効果) 및 적응성(適應性) 검토(檢討)- (Study on Heating Load Characteristics and Thermal Curtain Effects for Simple Silkworm Rearing Houses(II) -Effects of the Thermal Curtain on Energy Preservation and Review of its Application-)

  • 최광재;정두호;박경규
    • Journal of Biosystems Engineering
    • /
    • 제16권1호
    • /
    • pp.83-89
    • /
    • 1991
  • One of the most serious problems in Korean sericulture farms is to improve the adiabatic conditions for the simple silkworm rearing houses which has been widely adapted since early 1980'. Thus, this study is aimed to solve the problems by selecting the thermal screen material and by finding the method of its instalation. For the study, 4 kinds of materials which are (1) TE005,(2) NW60, (3) NW300 and (4) AL110 are selected and 4 different types of methods which are surrounding boundary of rearing bed(type A), surrounding inside of wall and ceiling (type B), installing on inside of wal ony (type C) and installing on ceiling Inly (type D) are installed. Decision criteria of the best combination of screen material and installation methods is made by calculating the heating load coefficients and by testing the application at the simple silkworm rearing houses. The obtained results are summarized as follows ; 1. The effect of thermal screen on reducing the thermal energy is remarkable. It saves energy more 50% than unscreened simple silkworm rearing houses. 2. From a stand point of a good screed material on thermal energy reduction, the NW300, AL110 and PE005 are recommanded materials. However, NW60 and PE005 are regarded as desirable materials from the practical point view. 3. Also, the effect on thermal energy reduction is largely affected by the method of thermal screen installation. The surrounding boundary of the silkworm rearing bed(type A) is the most desirable method to reduce the energy, which saves 56.6% of it. 4. In the practical application, NW60 and type A is considered to be the best combination of material and installation method. By this combination, the level of maximum heating load can be reduced at the rate of 43% for spring season and 40% for autumn season. 5. Another heating method, comparted heating, can be recommended to save the energy.

  • PDF

온실의 난방부하 결정을 위한 Degree-Hour 모델식 비교 분석 (Analysis and Comparison of Standard and Existed Heating Degree-Hours Model for decision of Greenhouse Heating Load in Korea)

  • 우영희
    • 현장농수산연구지
    • /
    • 제6권1호
    • /
    • pp.143-154
    • /
    • 2004
  • 본 실험은 기존의 난방 부하 모델식을 검토하고 문제점을 수정 보완하여 국내에 적용 가능한 모델식을 선정하고 지역별 온실내 목표온도에 따른 Degree hour 값을 결정하기 위하여 수행하였다. 국내 기상환경에 적용 가능한 모델식을 선정하기 위하여 1961년부터 2000년의 기상자료를 이용하여 온실내 목표온도를 9, 13, 16, 20℃로 설정하여 현재까지 개발된 모델식과 기본식의 지역별 DH값을 산출하였다. 지역별로 산출된 기본의 DH값을 종속변수, Mihara(6식)식, Hayashi(7식)식과 각각의 수정식인 6-1식, 7-1식을 독립변수로 하여 온실내 설정온도에 따른 수정결정상관계수를 분석한 결과 수정 Mihara(6-1)식이 기본식에 가장 근접하였다. 따라서 본 실험 조건하에서 국내적용 가능한 DH모델식은 수정 Mihara식임이 판명되었다. 수정 Mihara식을 이용하여 온실내 목표온도 9, 13, 16, 20℃ 따른 DH값 등고선 그래프를 지역별로 제시하였다.

Novel Electromagnetic Induction Eddy Current DPH based Continuous Pipeline Fluid Heating using Soft Switching PWM High Frequency Inverter

  • Nam, Jing-Rak
    • Journal of information and communication convergence engineering
    • /
    • 제6권3호
    • /
    • pp.305-309
    • /
    • 2008
  • This paper presents an innovative prototype of a new conceptual electromagnetic induction eddy current based fluid heating appliance using voltage-fed quasi resonant zero voltage soft switching PWM high-frequency inverter using IGBTs, which can operate at a constant frequency variable power regulation scheme. The promising simple high efficient low noise inverter type electromagnetic induction eddy current based pipeline fluid heating appliance is proposed for saturated steam generator, superheated steam generator, hot water and hot air producer, metal catalyst heating for exhaust gas cleaning in engine. Under these technological backgrounds, a novel electromagnetic induction eddy current Dual Packs Heater(DPH) based pipeline fluid heating incorporates thin metal layer type package for continuous fluid heating appliances applying two types of voltage-fed quasi load resonant ZVS-PWM high frequency inverter. The unique features of a novel electromagnetic induction eddy current DPH based continuous pipeline fluid heating appliance is illustrated on the basis of simulation and discussed for the steady state operating characteristics and experimental results.

봄철 태양열 하이브리드 시스템의 부하조건 변화에 따른 운전특성 연구 (Study on the Operating Characteristics with Load Condition in Hybrid Solar Heating System during Spring Season)

  • 표종현;김원석;조홍현;류남진
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.1418-1423
    • /
    • 2009
  • This study describes experimental study on the performance characteristics with load condition in hybrid solar heating system during spring season. The room temperatures, the hot water conditions and the lower part temperatures of heat storage tank were changed to analyze the system performances. As a results, the hot water was significantly affected by the ambient temperature. The indoor setting temperature affected the solar fraction. When the low part temperature of the storage tank increased, the temperature of the hot water rose and the temperature of the hot water in morning was affected by the ambient temperature.

  • PDF

주파수 추종과 정전력 제어가 가능한 고주파 유도가열기의 병렬 공진형 인버터에 대한 연구 (Study on the Parallel Resonant Inverter of an High Frequency Induction Heating System which the Frequency Tracking and the Power Regulation is possible)

  • 김남수;김태언;김승철;임영도
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2002년도 하계종합학술대회 논문집(5)
    • /
    • pp.63-66
    • /
    • 2002
  • This paper has been studied the parallel resonant inverter which controlling the constant power and tracking the load resonant frequency with PLL is possible, in order to minimize switching losses. The current-fed full-bridge type parallel resonant inverter of an induction heating system was composed of IGBT in switching device. For regulating the output power of an induction heating system, the Fuzzy controller is used. The Fuzzy controller makes the control signal for a stable power regulating control and when reference is changed, it is superior to adaptability. It has been evaluated a stable behavior for a noise with switching and a load disturbance.

  • PDF

열 파이프용 수평 축열조에서의 열 입력이 축열에 미치는 영향 (An Effect of Heat Input on Thermal Storage for Horizontal Thermal Storage Tank with Heat pipe)

  • 박이동;정운철
    • 태양에너지
    • /
    • 제16권2호
    • /
    • pp.39-47
    • /
    • 1996
  • 본 연구에서는 실제 열 파이프용 수평 축열조에서 등간격인 heating pad 수와 위치 및 공급열량을 변화시키면서 축열조내의 순수 Plume 유동특성을 파악하였다. 동일한 heating pad수를 가지고 집중 배치 형태와 분산 배치 형태를 취하였을 때 집중 배치 형태로 취하는 것이 $5{\sim}6%$ 정도의 더 높은 효율을 얻었다. 따라서 열 파이프용 수평 축열조에서 heating pad를 장착할 때 동일한 heating pad의 수에서는 집중(concentration)배치형태로 설계하는 것이 효과적임을 알 수 있다.

  • PDF

통계적 방법에 의한 건물 부하 산정 (Building Energy Load Estimation by a Statistical Method)

  • 정모;박화춘;임용훈
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2008년도 춘계학술발표대회 논문집
    • /
    • pp.342-347
    • /
    • 2008
  • A Microsoft $Access^{(R)}$ application that estimates hourly building energy load is developed based on statistical field measurements. Hourly patterns of heating, hot water, cooling, and electricity loads are evaluated for an energy consuming community composed of various types of buildings. Popular building types such as apartments, offices, hotels and accomodations, stores, churches, schools and educational institutes are included in the model. For each type of buildings, hourly patterns for a month are measured and compiled to derive a 24-hour load distributions. Daily sum of heating, hot water, cooling, and electricity loads are also measured for the building types. The annual energy need profiles are generated by combining the 24-hour distribution and 365-day consumption patterns. The annual maximum values of the 8760 hours of a year for each load type serves as a guide for selecting a device capacity. A user-friendly interface that ushers users throughout the whole process is provided.

  • PDF

부하 형태에 따른 몰드변압기에서의 진동데이터 비교에 관한 연구 (A Study on the Comparison of the Vibration Data in Cast Resin Transformer According to the Load Type)

  • 송길목;최명일;김영석;방선배;김종민
    • 조명전기설비학회논문지
    • /
    • 제26권4호
    • /
    • pp.75-81
    • /
    • 2012
  • In this study, vibration characteristics in according to the load type of cast resin transformer using vibration measurement device were compared. Measurement conditions are the same installation and operation of the three-phase cast resin transformer. If the load increases in transformer using the rotating machinery, the frequency is growing. In the transformer using the lighting and heating loads, it's detected the 55 [${\mu}m/s$] in or outside and 120 [${\mu}m/s$] or more at 60[Hz], the 30 [${\mu}m/s$] in or outside at 120[Hz], and the 70 [${\mu}m/s$] in or outside at 420[Hz]. When increases the loads, it's appeared the 60 [${\mu}m/s$] or less at 450[Hz] or more in rotating machinery, but the velocity of lighting and lighting loads are appeared from 5[${\mu}m/s$] to 115[${\mu}m/s$] inside the 420[Hz] in the same load condition of 20[%]. Through this study, it's verified that there are differences the internal vibration in according to the type of load in cast resin transformer.

조조가온기간이 시설재배 오이의 생육과 수량 및 난방부하에 미치는 영향 (Effect of Additional Early-Morning Heating Periods on the Growth and Yield of Cucumber and Heating Load)

  • 권준국;강남준;이재한;강경희;최영하
    • 생물환경조절학회지
    • /
    • 제13권4호
    • /
    • pp.245-250
    • /
    • 2004
  • 본 연구는 조조가온기간이 시설오이의 생육과 수량 및 난방부하에 미치는 영향을 구명하고자, 일출전에 난방온도를 올려서 $12^{\circ}C$에서 $16^{\circ}C$로 올려서 가온하는 기간을 2시간, 1시간 및 0시간을 비교하였다. 보온커텐을 열기 직전$(08:50\~09:00)$의 엽온은 조조가온을 하지 않는 것에 비해 1시간 가온이 $3.3^{\circ}C$, 2시간 가온이 $4.1^{\circ}C$각각 높았다. 오이 잎의 광합성, 기공전도도 및 증산량은 2시간 조조가온이 가장 좋았으나 1시간 가온과의 차이가 근소하였고 조조가온을 하지 않은 것은 현저히 감소하였다. 오이 잎의 무기성분함량은 유의적 차이는 없었으나 2시간, 1시간, 0시간 순으로 높은 경향이었다. 정식 이후의 초기생육은 1시간과 2시간 가온이 비슷하게 빨랐으나 조조가온을 하지 않는 것은 현저히 저조하였다. 과실 수량은 조조가온을 하지 않는 것에 비해 1시간 가온이 $11\%$, 2시간 가온이 $15\%$ 각각 증가되었다. 연료소모량은 조조가온하지 않는 것에 비해 1시간 가온이 $12\%$, 2시간 가온이 $22\%$ 각각 많았다. 생산물의 증수량과 연료소모량을 감안할 때 조조 가온하지 않는 것에 비해 가온한 것이 경영상 유리하였다.

지역난방 사용자 구성비에 따른 열소비 패턴 분석 (Heat Consumption Pattern Analysis by the Component Ratio of District Heating Users)

  • 이훈;이민경;김래현
    • 에너지공학
    • /
    • 제22권2호
    • /
    • pp.211-225
    • /
    • 2013
  • 본 연구에서는 서로 다른 위도의 도시 유형별로 주택과 건물 구성비를 가진 3지역을 선정하여 대상 지역별로 2008년 1년간(1.1~12.31)의 실제 운전실적을 이용하여 지역난방 사용자의 일일 및 연간 열소비 패턴을 분석하고, 지역별 상호 차이점을 파악하기 위하여 주택과 건물의 열소비 패턴을 비교 분석하였다. 특히 본 연구에서는 실제 주택 및 건물 지역난방 사용자가 사용한 열소비 패턴을 매시간대별로 파악하고, 연결 열부하(난방면적 ${\times}$ 단위열부하 : 시설용량과 지역난방 배관망의 설계기준이 되는 열부하로 난방면적에 용도별 단위열부하를 곱하여 산출[Gcal/h])와의 관계를 분석하여 일일, 연간 및 최대 부하율 결과값을 도출함으로써 주택 및 건물 지역난방 사용자 비율에 따른 최적의 열원시설 용량산정이 가능케 하고 수요개발(해당 시설용량으로 열공급이 가능한 지역난방 사용자의 범위로 각 사용자기계실의 연결열부하 합과 같음.)단계에서의 정확한 방향을 제시할 수 있는 근거를 도출하였다.