주거건물용 이중외피 시스템의 블라인드 조절에 따른 에너지 성능평가에 관한 연구 (Energy Performance Evaluation of a Double-skin Facade with a Venetian Blind in Residential Buildings)

  • 이소연;강재식;김강수
    • 한국태양에너지학회 논문집
    • /
    • 제30권6호
    • /
    • pp.1-9
    • /
    • 2010
  • Apartment balcony has been remodeled since the government permitted remodeling in January 2006.But extended balcony has great impact on building heat gain and loss. Therefore It has problems such as increase of heating and cooling energy. So $\underline{t}echnical$ solutions about window solar gain in summer is an urgent matter. The Purpose of this study is to evaluate energy performance of a blind in a double-skin facade in residential buildings by using EnergyPlus program. The results show that slat angles of $90^{\circ}$ is best in energy performance if we do not consider daylight. Poorly daylighted living room needs electric light and it also causes high cooling load. On the other hand, the results show that the application of blinds controlled automatically is best for energy performance when we consider daylight. Blind slat angles of $50\sim60^{\circ}$ have best performance when blinds are controlled in this angle throughout the day on a clear day in August. Blind slat angles of $0\sim30^{\circ}$ have best performance when blinds $\underline{are\;controlled}$ in this angle throughout the day on a cloudy day (more than 7 of total sky cover) in August.

설계하중 사전재하 및 잔존강도 시험방법에 따른 고강도콘크리트의 고온특성 평가 - 제2보 변형특성을 중심으로 - (Evaluation for mechanical properties of high strength concrete by stressed test and stressed residual strength test - part 2 strain properties -)

  • 김영선;이태규;이대희;이승훈;김규용;김무한
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2008년도 춘계 학술발표회 제20권1호
    • /
    • pp.761-764
    • /
    • 2008
  • 본 연구는 40, 60, 80MPa급 고강도콘크리트의 변형특성에 있어서 $20{\sim}700^{\circ}C$ 범위로 상승되는 온도의 영향을 연구하는데 그 목적이 있다. 본 연구에서 시험의 종류는 설계하중 사전재하 및 잔존 강도 시험방법으로서 시험체를 가열하기 전에 극한강도의 25%하중을 사전재하한 후 가열을 실시하고, 가열하는 동안 하중을 유지하며, 목표온도에 도달한 후 고온상태 및 상온에서 24시간 냉각상태에서 시험체가 파괴될 때까지 재하를 실시했다. 시험은 W/B 46%, 32% 및 25%로 이루어진 콘크리트 시험체에 대하여 $20{\sim}700^{\circ}C$의 다양한 온도하에서 실시하였다. 시험결과 콘크리트 강도가 증가할수록 고온에서의 상대적인 탄성계수는 감소하였으며, 최대하중에서의 축방향 변형은 설계하중 사전 재하와 상관성이 높은 것으로 나타났다. 또한 온도상승에 따른 콘크리트의 열팽창변형은 압축강도뿐만 아니라 초기사전재하의 영향을 받는 것으로 나타났다.

  • PDF

Post-fire test of precast steel reinforced concrete stub columns under eccentric compression

  • Yang, Yong;Xue, Yicong;Yu, Yunlong;Gong, Zhichao
    • Steel and Composite Structures
    • /
    • 제33권1호
    • /
    • pp.111-122
    • /
    • 2019
  • This paper presents an experimental work on the post-fire behavior of two kinds of innovative composite stub columns under eccentric compression. The partially precast steel reinforced concrete (PPSRC) column is composed of a precast outer-part cast using steel fiber reinforced reactive powder concrete (RPC) and a cast-in-place inner-part cast using conventional concrete. Based on the PPSRC column, the hollow precast steel reinforced concrete (HPSRC) column has a hollow column core. With the aim to investigate the post-fire performance of these composite columns, six stub column specimens, including three HPSRC stub columns and three PPSRC stub columns, were exposed to the ISO834 standard fire. Then, the cooling specimens and a control specimen unexposed to fire were eccentrically loaded to explore the residual capacity. The test parameters include the section shape, concrete strength of inner-part, eccentricity ratio and heating time. The test results indicated that the precast RPC shell could effectively confine the steel shape and longitudinal reinforcements after fire, and the PPSRC stub columns experienced lower core temperature in fire and exhibited higher post-fire residual strength as compared with the HPSRC stub columns due to the insulating effect of core concrete. The residual capacity increased with the increasing of inner concrete strength and with the decreasing of heating time and load eccentricity. Based on the test results, a FEA model was established to simulate the temperature field of test specimens, and the predicted results agreed well with the test results.

EnergyPlus에 적용된 Simple Window Model의 한계와 개선에 관한 연구 (A Study on the Limitation and Improvement of Simple Window Model applied to EnergyPlus)

  • 김태호;고성호
    • 설비공학논문집
    • /
    • 제29권10호
    • /
    • pp.515-529
    • /
    • 2017
  • EnergyPlus, which is widely used in various fields, provides Simple Window Model, a window model that can be used practically. However, the results of building load using the model are different from those of the standard model. The main cause of the deviation by Simple Window Model was analyzed to be due to the assumption that all windows were considered as single layer. The purpose of this study is to propose a window model that improves the cause of deviation by Simple Window Model and can be easily calculated from the algebraic relations. The proposed window model solved the heat balance equation algebraically by using seven window characteristic coefficients. The coefficient relationships consisted of the heat transmission coefficient and solar heat gain coefficient as input parameters make practical use and calculation possible. As a result of comparing the deviation between each window model by implementing the dynamic analysis method, the proposed window model showed that the deviation of the total heating/cooling energy consumption was reduced to 1/3 compared to Simple Window Model for one year. Although the maximum energy consumption did not show any significant improvement, the indoor temperature evaluation showed significantly reduced deviation.

컴팩트형 VAV 공조기의 성능평가와 경제성 분석에 관한 연구 (A Study on Economic Analysis and Performance Appraisal of Compact Type Variable Air Volume)

  • 김동철;정광섭;김영일
    • 설비공학논문집
    • /
    • 제27권1호
    • /
    • pp.44-49
    • /
    • 2015
  • Ceiling cooling and heating system that consider load arrangement and space in the ceiling needs to be developed. Therefore, experimental and economic changes were done to verify the performance of compact type VAV. The test results were as follow. 1) Noise test result, measuring approximately 50.4 dB~56.6 dB (before ceiling in landfill), had a better ceiling deadline than the current measure, about a 10 dB noise reduction, so that the office baseline (40~50 dB) noise was judged to be less than test. 2) For the static pressure test result, taking out an outside hydrostatic 25 mmAq, 24.8 mmAq was measured, respectively, at the point. 3) For the life-cycle cost analysis result, the initial investment cost, maintenance replacement costs, and maintenance costs increased 0.2%, but the energy savings ratio was 19.5% while the whole life cycle savings of 40 years LCC was reduced 11.9%.

A Study on the Development of Building Envelope Elements for Energy Reduction in Multi- Rise Residential Buildings

  • Lee, Myung Sik
    • Architectural research
    • /
    • 제18권4호
    • /
    • pp.151-155
    • /
    • 2016
  • It is necessary to improve the performance of buildings with respect to the energy efficiency while improving the quality of occupants' lives through a sustainable built environment. During the design and development process, building projects must have a comprehensive, integrated perspective that seeks to reduce heating, cooling and lighting loads through climate-responsive designs. The aim of this study is to find an optimal thermal transmittance (U-values) for building envelope elements for low energy multi-rise residential buildings in the early design phase in Korea. The study found that using small U-values of $0.15w/m^2K$ for exterior walls, ceilings and floors and $1.0w/m^2K$ for south and north facing windows has resulted in energy reduction of 22.1%-59.4% in the south facing rooms and 43%-77.6% of the north facing rooms. It has also found the energy load reduction potential of using small U-values are higher on the north facing rooms. The findings of this study can be suggested to be used as a baseline case for low energy consumption studies. It can also be used to determine appropriate envelope materials and insulation values.

업무용 건축물의 실내 조명기구 특성에 따른 발열 효과에 관한 연구 (Interior heating effect in an office building according to heat properties of light fixture)

  • 이윤진;안병립;김종훈;정학근;장철용;김태연
    • KIEAE Journal
    • /
    • 제15권2호
    • /
    • pp.117-122
    • /
    • 2015
  • Purpose: Generally, 30% of the total energy consumption in office building is used for artificial indoor lightings, and almost 75-85% of electric power in fluorescent and Light-Emitting Diode (LED) lightings can be dissipated as a form of heat into indoor environment. The heat generated by indoor lightings can cause the increase of cooling load in office buildings. Thus, it its important to consider indoor lightings as a heat and light source, simultaneously. Method: In this study, we installed two kinds of indoor lightings including fluorescent and LED lightings and measured surface temperature of both indoor lightings. In addition, we obtained ambient temperature of indoor space and finally calculated total heat dissipated from plenum area and surface of lightings. Result: Total indoor heat gain was 87.17Wh and 201.36Wh in cases of six 40W-LED lightings and 64W-fluorescent lightings, respectively.

실측을 통한 공동주택 단지 내에서의 온열환경 및 거주자 쾌적감 평가에 관한 연구 (Assessment on Thermal Environment and Human Thermal Comfort in Residential Building Block through Field Measurement)

  • 임종연;황효근;송두삼;김태연
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2008년도 춘계학술발표대회 논문집
    • /
    • pp.311-317
    • /
    • 2008
  • As outdoor environment become worse due to concentration of population in large cities, the importance of environmental control strategies such as the arrangement of green space or water space and ventilation paths, has been increasingly recognized. However, most of the studies focus on the assessment on outdoor thermal environment, few studies focus on the interrelationship between thermal environment in residential block and human thermal comfort. The aims of this study is to develop the outdoor planning method to reduce the heating/cooling load in an apartment unit or entire block by the sustainable approaches in outdoor environmental design. In this paper, on the basis of the prior studies, the effect of the outdoor thermal environment on human thermal comfort will be analysed.

  • PDF

후면 유리 종류에 따른 투과형 태양광발전모듈의 열 및 광 특성 분석 (Analysis of Thermal and Optical Characteristic of Semi-transparent Module according to Various Types of the Backside Glass)

  • 박경은;강기환;김현일;김경수;유권종;김준태
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2008년도 춘계학술발표대회 논문집
    • /
    • pp.263-268
    • /
    • 2008
  • Building Integrated PV(BIPV) is one of the best fascinating PV application technologies. To apply PV module in building, various factors should be reflected such as installation position, shading, temperature, and so on. Especially a temperature should be considered, for it affects both electrical efficiency of a PV module and heating/cooling load in a building. This study investigates a semitransparent PV module that is designed as finished material for windows. Therefore it needs to considerate about the optical characteristics of the transparent module. It reports the effect of thermal and optical characteristics of the PV module on generation performance. The study was performed by measuring sun spectrum and luminance through the PV modules and by monitoring the temperature and experiment. The results showed that 1 degree temperature rise reduced about 0.48% of output power.

  • PDF

케이스먼트 창호 개폐방식에 따른 자연환기 효과에 관한 시뮬레이션 연구 (A Study on the Simulation of Natural Ventilation Effect for Single-sided Casement Window as Opening Types)

  • 최태환;김태연;이승복
    • KIEAE Journal
    • /
    • 제7권4호
    • /
    • pp.57-62
    • /
    • 2007
  • At the moment, the reduction of building energy consumption is a unavoidable task of mankind for conserving global environment. Decreasing overall U-value of building envelope and air infiltration, especially in Korean climate condition with clear four seasons, are the obvious solutions for the objective. Thus low glazing ratio with small window openings are required for heating and cooling load reduction in buildings. Using larger window openings could provide better natural ventilation but it also increases the direct solar radiation penetration into indoor space, heat gain in summer and heat loss in winter. On the other hand, the ventilation rates decreasing problem with smaller window openings could be occurred. As a solution for it, the use of casement window can cause increasing natural ventilation rates by wing wall effect. This paper focuses on deduce the most efficient opening type of casement window in Korean climate. To estimate ventilation performance of each opening types, CFD simulation was used. The best performance of opening type in every wind direction is opening both windows to the center and the most appropriate opening type for Korean climate is also opening both windows to center.