• 제목/요약/키워드: Heating cooling load

검색결과 385건 처리시간 0.03초

온도와 부하의 비선형성을 이용한 단기부하예측에서의 TAR(Threshold Autoregressive) 모델 (TAR(Threshold Autoregressive) Model for Short-Term Load Forecasting Using Nonlinearity of Temperature and Load)

  • 이경훈;이윤호;김진오
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제50권9호
    • /
    • pp.309-405
    • /
    • 2001
  • This paper proposes TAR(Threshold Autoregressive) model for short-term load forecasting including temperature variable. In the scatter diagram of daily peak load versus daily high or low temperature, we can find out that the load-temperature relationship has a negative slope in the lower regime and a positive slope in the upper regime due to the heating and cooling load, respectively. TAR model is adequate for analyzing these phenomena since TAR model is a piecewise linear autoregressive model. In this paper, we estimated and forecasted one day-ahead daily peak load by applying TAR model using this load-temperature characteristic in these regimes. The results are compared with those of linear and quadratic regression models.

  • PDF

지역난방 열사용시설 자동제어시스템 개선을 통한 회수온도 저감 연구 (The Decrease of Return Temperature by Improvement of the Consumer's Control System in District Heating)

  • 하승규;김연홍;이훈
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.245-251
    • /
    • 2006
  • The main idea of this study is to turn attention on the question of good cooling ability of customer substations in large district heating networks. The main reason for that is based on our experience that the optimization of district heating very often is directed toward production, whereas questions of optimal distribution are neglected if only the necessary load can be supplied and the customer's request for comfort is met. Our view is that low return temperature(operational temperature differences, ${\Delta}T$) in district heating systems is an Important feature for efficient net operation and gives both economic and operational benefits to the district heating supplier Furthermore, it is as well a prerequisite for meeting the customers demand for reliable supply of the heat load. However, in many practical cases we have seen that district heating return temperatures are higher than necessary. Hence, the aim of the study is to propose and verify a method for detection of the most critical consumers of the net and to identify the reasons for resulting high return temperature. From the results, temperature control system is presented as one of the most important reason of high return temperature in DH networks.

  • PDF

열펌프, 데시칸트 및 증발식 냉각기를 조합한 하이브리드 냉방 시스템의 동특성 해석 연구 (Dynamic Simulation of a Hybrid Cooling System utilizing Heat Pump, Desiccant and Evaporative Cooler)

  • 서정남;김영일;정광섭
    • 한국지열·수열에너지학회논문집
    • /
    • 제7권1호
    • /
    • pp.45-50
    • /
    • 2011
  • Hybrid desiccant cooling system(HDCS) consists of desiccant rotor, regenerative evaporative cooler, heat pump and district heating hot water coil. In this study, TRNSYS and EES, dynamic and steady simulation programs were used for studying hybrid desiccant cooling system which is applied to an apartment house from June to August. The results show that power consumption of the hybrid desiccant cooling system is 70 kWh in June, 199 kWh in July and 241 kWh in August. Sensible and latent heats removed by the hybrid desiccant cooling system are 300 kWh, 301 kWh in June, 610 kWh, 858 kWh in July and 719 kWh, 1010 kWh in August. COP of the hybrid desiccant cooling system is 8.6 in June, 7.4 in July and 7.2 in August. COP of the hybrid desiccant cooling system decreases when latent heat load increases. Operation time of the system is 70 hours in June, 190 hours in July and 229 hours in August. Since the cooling load is largest in August, the operation time of August is longest for maintaining the indoor temperature at $26^{\circ}C$. Due to the characteristics of hybrid desiccant cooling system for efficiently handling both sensible and latent loads, this system can handle sensible and latent heat loads efficiently in summer.

Economizer cycle control을 채용한 전열교환시스템의 에너지 절감효과 분석 -국내 공동주택을 대상으로- (Energy Saving Effect of ERV(Energy Recovery ventilator) with Economizer Control in Residential Building)

  • 박재형;김주욱;송두삼;윤호영;김성우
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.679-684
    • /
    • 2009
  • ERV system has installed in almost newly constructed residential building in Korea. Heat recovery features of ERV can be possible to decrease the heating and cooling load caused by ventilation. However, in case of the outdoor condition is favorable to control the indoor air, the heat recovery function of ERV does more harm than good in term of cooling load. In this study, the ERV with economizer cycle control for residential building is suggested and the performance of the suggested system will be analyzed using TRNSYS.

  • PDF

건물에너지시뮬레이션 기법을 이용한 육계사 표준설계모델의 에너지 부하 산출 (Evaluation of Energy Loads for Broiler-Standard Design Models Using a Building Energy Simulation Method)

  • 권경석;양가영;김종복;장동화;하태환;전소라
    • 한국농공학회논문집
    • /
    • 제65권1호
    • /
    • pp.27-39
    • /
    • 2023
  • This study was to quantitatively evaluate periodic and maximum energy loads for broiler-standard design models by the Ministry of Agriculture, Food and Rural Affairs (2016). Building energy simulation method was used to compute heating and cooling loads of the designed broiler houses according to regional locations and insulation characteristics of wall and roof. It considered sensible and latent heat generation from broilers, dynamic operation of ventilation system according to environment variations. It was found that variation of periodic heating loads was relatively higher than that of periodic cooling loads according to thickness changes of wall and roof. Assuming that broiler was raised at every even-month, periodic heating and cooling loads were 6 and 18% lower, respectively than odd-month raising condition. When recommendation rules of insulation characteristics (wall and roof thickness) by the Ministry of Land, Infrastructure and Transport was adopted, periodic heating load of Jeju-si was 20.3% higher than national average values. Based on the BES computed periodic and maximum energy loads under the designed experimental condition, these results can contribute to reestablishing standard design of broiler houses, especially for insulation characteristics, and designing management strategies for efficient energy uses.

부산지역에서의 기상 수치모의 자료를 이용한 건축물 에너지 분석 (Analysis of Building Energy using Meteorological Numerical Simulation Data over Busan Metropolitan Areas)

  • 이귀옥;김민준;이강열;강동배;박창현;이화운;정우식
    • 한국환경과학회지
    • /
    • 제23권3호
    • /
    • pp.503-510
    • /
    • 2014
  • To estimate the benefit of high-resolution meteorological data for building energy estimation, a building energy analysis has been conducted over Busan metropolitan areas. The heating and cooling load has been calculated at seven observational sites by using temperature, wind and relative humidity data provided by WRF model combined with the inner building data produced by American Society of Heating Refrigeration and Air-conditioning Engineers (ASHRAE). The building energy shows differences 2-3% in winter and 10-30% in summer depending on locations. This result implicates that high spatiotemporal resolution of meteorological model data is significantly important for building energy analysis.

니켈-타이타늄 호선의 상전이 온도 범위와 상전이 행동 비교 (Comparison of transition temperature range and phase transformation behavior of nickel-titanium wires)

  • 이유현;임범순;이용근;김철위;백승학
    • 대한치과교정학회지
    • /
    • 제40권1호
    • /
    • pp.40-49
    • /
    • 2010
  • 본 연구의 목적은 martensitic (M-NiTi), austenitic (A-NiTi) 및 thermodynamic nickel-titanium wire (T-NiTi)의 물리적 특징과 상전이 정도를 평가하는 것이다. 재료는 $0.016\;{\times}\;0.022$ inch의 M-NiTi (Nitinol Classic, NC), A-NiTi (Optimalloy, OPTI)와 T-NiTi (Neo-Sentalloy, NEO)이었으며, differential scanning calorimetry (DSC), 3점굽힘실험, X-ray diffraction (XRD), 미세구조 분석을 시행하였으며, ANOVA test로 통계처리하였다. DSC분석 결과 OPTI와 NEO는 heating curve에서 2개의 peak, cooling curve에서 1개의 peak를 보였고, NC는 heating과 cooling curve에서 1개의 넓고 약한 peak를 보였다. Austenite finishing ($A_f$) 온도는 OPTI $19.7^{\circ}C$, NEO $24.6^{\circ}C$, NC $52.4^{\circ}C$였다. 3점굽힘실험 결과 NC, OPTI, NEO 모두 residual deflection을 보였으며, NC와 OPTI의 load range가 NEO보다 컸다. XRD와 미세구조 분석결과 OPTI와 NEO는 Martensite finishing ($M_f$)에서 martensite와 austenite가 섞여 있음이 관찰되었다. NEO와 OPTI는 NC보다 개선된 물리적 특징과 상전이 행태를 보였다. NiTi 호선의 물리적, 온도에 따른 행태는 예상되었던 상전이 정도에 의해 완벽하게 설명되지 않았으며, 그 이유는 복잡한 martensite variants의 존재와 열과 stress에 의해 유도된 독립적인 상전이에 기인한다고 생각된다.

루프형 양방향 열 다이오드 시스템의 열 성능에 관한 실험적 연구 (Experimental Study on the Thermal Performance of a Loop-Type Bidirectional Thermo-Diode System)

  • 천원기;김신
    • 태양에너지
    • /
    • 제18권2호
    • /
    • pp.105-113
    • /
    • 1998
  • 일반적으로 열 다이오드(thermo-diode)란 임의의 한 방향으로만 열 전달이 가능하도록 설계된 열 전달 기구이나, 열 흐름이 원하는 방향으로 이루어지는 양방향 열 다이오드를 사용한다면 겨울철 난방과 여름철 냉방부하 감소에 모두 효과적으로 적용될 수 있다. 본 연구에서는 루프형 양방향 열 다이오드를 응용한 태양열 이용 시스템을 설계 제작하였으며, test cell을 이용한 옥외 실험을 수행하여 실용 가능성을 확인하였다.

  • PDF

온도를 변수로 갖는 단기부하예측에서의 TAR(Threshold Autoregressive) 모델 도입 (Introduction of TAR(Threshold Autoregressive) Model for Short-Term Load Forecasting including Temperature Variable)

  • 이경훈;이윤호;김진오
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 추계학술대회 논문집 학회본부 A
    • /
    • pp.184-186
    • /
    • 2000
  • This paper proposes the introduction of TAR(Threshold Autoregressive) model for short-term load forecasting including temperature variable. TAR model is a piecewise linear autoregressive model. In the scatter diagram of daily peak load versus daily maximum or minimum temperature, we can find out that the load-temperature relationship has a negative slope in lower regime and a positive slope in upper regime due to the heating and cooling load, respectively. In this paper, daily peak load was forecasted by applying TAR model using this load-temperature characteristic in these regimes. The results are compared with those of linear and quadratic regression models.

  • PDF

PHC 에너지파일의 열응력에 따른 축하중-침하 수치해석 (Numerical Analysis of Thermal Effect on Axial Load and Pile Settlements in PHC Energy Piles)

  • 이대수;민혜선;임현성;정상섬
    • 한국지반공학회논문집
    • /
    • 제29권5호
    • /
    • pp.5-17
    • /
    • 2013
  • 본 논문에서는 열응력에 따른 PHC 에너지파일의 축하중과 침하량의 변화를 수치해석을 통하여 분석하였다. 이를 위해 $3{\times}3$, $5{\times}5$ 배열 군말뚝 형태의 에너지파일을 말뚝 간격과 배치, 지반조건, 말뚝의 선단지지조건 및 말뚝 캡의 강성도 등의 조건으로 구분하여 수치해석을 수행하였다. 본 연구 결과 말뚝 중심 간격이 클수록 온도변화에 따른 말뚝의 축하중 차이가 크게 나타났고, 사질토지반이 점성토지반 보다 온도변화에 의한 침하량의 변화가 크게 나타났다. 또한, 에너지파일이 모서리부에 위치할 때 말뚝의 축하중 차이가 가장 크게 나타났으며, 말뚝의 선단이 암반에 지지된 경우 온도변화에 의한 축하중 변화가 더 크게 발생하여 침하량이 감소하는 것을 확인하였다. 말뚝 캡의 강성도에 대한 영향은 말뚝 캡의 강성이 커질수록 온도변화에 의한 침하량이 감소하는 것으로 나타났다.