• Title/Summary/Keyword: Heating control

검색결과 1,589건 처리시간 0.044초

고온, 한냉 및 산도가 토끼 적혈구막 투과성에 미치는 영향 (Influence of Heating, Cooling and Acidity on the Permeability of the Rabbit Erythrocyte Membrane)

  • 이덕숙;신효숙;황애련;최덕경
    • The Korean Journal of Physiology
    • /
    • 제1권2호
    • /
    • pp.151-156
    • /
    • 1967
  • Outward movement of hemoglobin and $K^+$ ion across rabbit erythrocyte membrane after heating, cooling and in acid medium was studied. One milliliter of rabbit blood was centrifuged and packed red cells were obtained. Packed red cells were resuspended by addition of 4 ml of 0.9% NaCl solution and were subjected to heating $(57^{\circ}C\;for\;5\;minutes)$ or cooling $(-4^{\circ}C{\sim}-8^{\circ}C\;of\;-10^{\circ}C{\sim}-11^{\circ}C\;for\;10\;minutes) $. For acid medium experiment packed ref cells were resuspended by addition of 4 ml of acid medium of PH 4.5 consisting of 0.01% glacial acetic acid in 0.85% NaCl solution and kept standing for 10 minutes. All red cell suspensions were centrifuged again and packed red cells were separated. This packed red cells were again suspended in 4 ml of NaCl solution of 0.8%, 0.7%, 0.6%, and 0.5% concentration respectively and kept standing for 20 minutes. The concentration of hemoglobin and $K^+$ in the supernatant of the above red cell suspensions were measured and the following results were obtained. 1. Outward movement of hemoglobin and $K^+$ was greatest in red cells subjected to heating. The movement paralled to the osmolal concentration gradient between extra- and intra-cellular phase of red cells. 2. In acid medium the outflux of hemoglobin and $K^+$ increased as compared to the control. 3. In red cells subjected to the cold of $-10^{\circ}C{\sim}-11^{\circ}C$ the outflux of hemoglobin and $K^+$ increased. Whereas in the environment of $-4^{\circ}C{\sim}-8^{\circ}C$ there was no change in the outflux of $K^+$. The he-moglobin outflux showed rather a decreased as compared to tile control.

  • PDF

원적외선 난방시스템의 난방특성 및 방울토마토${\cdot}$잎들깨의 생장 특성 분석 (Analysis of heating properties of far infrared heating system and growth properties of Cherry tomato and Perilla)

  • 김학주;이시영;한충수;최영하;전희;염성현;강윤임
    • 한국생물환경조절학회:학술대회논문집
    • /
    • 한국생물환경조절학회 2005년도 세계의 친환경 시설원예 기술동향 및 추계 국제학술대회 발표논문집
    • /
    • pp.154-158
    • /
    • 2005
  • PDF

펠티어 냉난방시스템 최적화 기술에 관한 연구 (A Study on Optimization Development of Peltier Air-conditioning System)

  • 박상훈;정수진;박영우;박유경;송범중
    • 융복합기술연구소 논문집
    • /
    • 제3권1호
    • /
    • pp.19-23
    • /
    • 2013
  • This study is concerned with air-conditioning system in use of thermoelectric device. It is introduced that the well designed structures for better cooling & heating performance with high efficiency. And also it is performed that the system performance test of four types trial products for the use of hybrid commercial vehicle. System performance is affected by many component parts, especially heat sink design & power control method. It is applied that dual extrusive fin tube with buffer zone for the effective radiating of circulating liquid in tube. And also it is applied that power supply method with constant-current system. It is attained that system cooling capacity is 1.2kW, COP is 0.95.

  • PDF

공진회로(共振回路)를 이용한 유도가열용(誘導加熱用) 부분순환전류형(部分循環電流形) 사이크로콘버터에 관한 연구(硏究) (A Study of the Partial Circulating Current Type Cycloconverter with a Resonant Circuit for Induction Heating)

  • 김현중;조규민;김영석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1992년도 하계학술대회 논문집 B
    • /
    • pp.1002-1004
    • /
    • 1992
  • This paper presents a study of the partial circulating current type cycloconverter with a resonant circuit for induction heating. A method of input power factor improvement is proposed. Since the circulating currents flow through the circulating current reactors, the out-put currents are continuous and sinusoid. The proposed cycloconverter can keep the displacement factor at 1.0 by PWM control method regardless of load. The control functions are derived, the operational principles are described and the simulation and experimental results are presented.

  • PDF

NBI용 필라멘트 전원공급 장치를 위한 풀-브리지 DC/DC 컨버터 (Full-Bridge DC/DC Converter for NBI Filament Power Supply)

  • 전범수;이세형;이희준;신수철;이승교;원충연
    • 조명전기설비학회논문지
    • /
    • 제25권7호
    • /
    • pp.32-39
    • /
    • 2011
  • FPS(Filament Power Supply), one of the KSTAR NBI(Neutral Beam Injections) is implemented by full-bridge DC/DC converter. NBI heating device for KSTAR(1.5MW) is developed for heating an ion source of plasma in KSTAR tokmak. The full-bridge DC/DC converter is applied to FPS for isolation with input and output. And FPS is operated with PWM control method which is the most usual method. In this paper, NBI FPS of 4.8kW is simulated by using the PSIM 6.0. And the full-bridge DC/DC converter using IGBTs is fabricated to demonstrate it. The processor DSP 28335 is implemented for digital control.

식각 용기 가열에 의한 라디칼 손실 제어가 고선택비 산화막 식각에 미치는 영향 (Effect of the Radical Loss Control by the Chamber Wall Heating on the Highly Selective $SiO_2$ etching)

  • 김정훈;이호준;주정훈;황기웅
    • 한국진공학회지
    • /
    • 제5권2호
    • /
    • pp.169-174
    • /
    • 1996
  • The applications of the high density plasma sources to the etching in semiconductor fabrication process are actively studied because of the more strict requirement from the dry etching process due to shrinking down of the critical dimension. But in the oxide etching with the high density plasma sources, abundant fluorine atoms released from the flurocarbon feed gas make it difficult to get the highly selective $SiO_2/Si$ etching. In this study, to improve the $SiO_2/Si$ etch selectivity through the control of the radical loss channels, we propose the wall heating , one of methods of controlling loss mechanisms. With appearance mass spectroscopy(AMS) and actinometric optical emission spectroscopy(OES), the increase of both radicals impinging on the substrate and existing in bulk plasma, and the decrease of the fluorine atom with wall temperature are observed. As a result, a 40% improvement of the selectivity was achieved for the carbon rich feed gas.

  • PDF

NBI용 필라멘트 전원공급장치를 위한 풀-브릿지 DC/DC 컨버터 (Full-Bridge DC/DC Converter for NBI Filament Power Supply)

  • 임희성;이세형;전범수;이승교;원충연
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2010년도 하계학술대회 논문집
    • /
    • pp.485-486
    • /
    • 2010
  • FPS(Filament Power Supply), one of the KSTAR NBI (Neutral Beam Injections) is implemented by full-bridge DC/DC converter. NBI heating device for KSTAR(1.5MW) is developed for heating an ion source of plasma in KSTAR tokmak. The full-bridge DC/DC converter is applied to FPS for isolation with input and output. And FPS is operated with PWM control method which is the most usual method. In this paper, NBI FPS of 4.8kW is simulated by using the PSIM 6.0. And the full-bridge DC/DC converter using IGBTs is fabricated to demonstrate it. The processor DSP 28335 is implemented for digital control.

  • PDF

Field Enhanced Rapid Thermal Process for Low Temperature Poly-Si TFTs Fabrications

  • Kim, Hyoung-June;Shin, Dong-Hoon
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2005년도 International Meeting on Information Displayvol.I
    • /
    • pp.665-667
    • /
    • 2005
  • VIATRON TECHNOLOGIES has developed FE-RTP system that enables LTPS LCD and AMOLED manufacturers to produce poly-Si films at low cost, high throughput, and high yield. The system employs sequential heat treatment methods using temperature control and rapid thermal processor modules. The temperature control modules provide exceptionally uniform heating and cooling of the glass substrates to within ${\pm}2^a\;C$. The rapid thermal process that combines heating with field induction accelerates the treatment rates. The new FE-RTP system can process $730{\times}920mm$ glass substrates as thin as 0.4 mm. The uniform nature of poly-Si films produced by FE-RTP resulted in AMOLED panels with no laser-Muras. Furthermore, FE-RTP system also showed superior performances in other heat treatment processes involved in poly-Si TFT fabrications, such as dopant activation, gate oxide densification, hydrogenation, and pre-compaction.

  • PDF

축소모형을 이용한 실내 수공간 도입 효과 연구 (A Study on the Change of Indoor Heating Environment with the Creation of Indoor Water Space through a Scale Model)

  • 오상목;오세규
    • KIEAE Journal
    • /
    • 제10권6호
    • /
    • pp.67-72
    • /
    • 2010
  • This study was conducted to examine the change of heating environment with the creation of an indoor water space. Living environments and comfort of dwellers can be improved by utilizing the physical properties of water effectively. This study focuses on the basic examination of the effect of water space and the environmental effects of water space by experiment. Two identical models were fabricated to compare the changes in indoor temperature and humidity with and without a water space. With the water space, temperature was reduced by an average of $0.55^{\circ}C$ a day and moisture content increased by an average of 4%. As a result, it was possible to obtain quantitative data on water space's temperature reduction and humidity control capacities. This study is expected to provide basic information for further studies on the effect of water spaces in various buildings.

Statistical Modeling of the Pretilt Angle Control in Nematic Liquid Crystal using In-situ Photoalignment Method on Plastic Substrate

  • Kang, Hee-Jin;Lee, Jung-Hwan;Yun, Il-Gu;Seo, Dae-Shik
    • Transactions on Electrical and Electronic Materials
    • /
    • 제7권3호
    • /
    • pp.145-148
    • /
    • 2006
  • In this study, the response surface modeling of the pretilt angle control using in-situ photoalignment method with oblique UV exposure .on plastic substrate is investigated. The pretilt angle is the main factor to determine the alignment of the liquid crystal display. The response surface model is used to analyze the variation of the pretilt angle on the various process conditions. Heating temperature and UV exposure time are considered as input factors. The liquid crystal (LC) pretilt angle increased with increasing heating temperature and UV exposure time. The analysis of variance is used to analyze the statistical significance and the effect plots are also investigated to examine the relationship between the process parameters and the response.