• 제목/요약/키워드: Heating cartridges

검색결과 4건 처리시간 0.02초

국부가열효과를 활용한 다점성형공정기술 (Multi-point Dieless Forming Technology Using Local Heating Effect)

  • 박지우
    • 소성∙가공
    • /
    • 제31권2호
    • /
    • pp.96-102
    • /
    • 2022
  • The multi-point dieless forming technology is one of flexible forming technologies that can form 3D curved surfaces of various shapes utilizing a lot of punch arrangements. A new technology that can simultaneously apply high-temperature forming and flexible forming technology by fusing local heating effect to such multi-point dieless forming technology was proposed in the present study. A simple local heating multi-point dieless forming apparatus was fabricated to confirm the applicability of this new technology. This equipment was designed to be used as a heat source by inserting heating cartridges in the head of the multi-point punch. Cartridges were used for all individual punches. Using the manufactured equipment, the time to raise the temperature to the target temperature and the surface temperature of the punch head part in contact with the plate were measured. In addition, forming experiments were carried out according to sheet material temperature (100 ℃, 200 ℃, and 300 ℃) to obtain forming results for each condition. The applicability and feasibility of this technology were confirmed through experimental results.

마이크로웨이브와 Sep-Pak 카트리지를 이용한 $^{99m}Tc$-ECD, $MAG_3$, MIBI의 신속한 제조 및 정도관리 (Rapid Preparation and Quality Control of $^{99m}Tc$-ECD, $MAG_3$ and MIBI using Microwave Heating and Sep-Pak Cartridges)

  • 오승준;문대혁;류진숙;이희경
    • 대한핵의학회지
    • /
    • 제33권4호
    • /
    • pp.430-438
    • /
    • 1999
  • 목적: 마이크로웨이브를 이용한 방사성 동위원소의 표지와 Sep-Pak 카트리지를 이용한 정도관리 방법의 개선으로 신속한 제조가 가능하면서도 높은 표지효율을 가진 방사성 의약품을 얻고자 하였다. 대상 및 방법: $C_{18}$ 그리고 alumina N Sep-Pak카트리지를 이용한 정도관리 방법을 $^{99m}Tc$-ECD, $^{99m}Tc$-MIBI, $^{99m}Tc-MAG_3$에 적용하였고 표지효율을 측정하였다. 마이크로웨이브를 사용하여 상기의 키트에 방사성 동위원소를 표지하여 표지효율을 비교하였다. 결과: 마이크로웨이브에 의해 생성된 세 가지방사성 의약품은 3 ml용액에 $^{99m}Tc$-ECD와 $^{99m}Tc$-MIBI는 10초, $^{99m}Tc-MAG_3$는 15초의 짧은 마이크로웨이브를 조사하여 모두 95% 이상의 표지효율을 나타내었다. $^{99m}Tc$-ECD와 $^{99m}Tc$-MIBI는 Sep-Pak alumina N 카트리지를 사용하여 짧은 시간 내에서도 정확한 정도관리 결과를 얻을 수 있었다. 방사성 의약품의 제조시간은 정도관리를 포함하여 모두 6분 이하를 나타내었다. 결론: Sep-Pak 카트리지를 이용한 정도관리 방법과 마이크로웨이브에 의한 방사성 의약품의 제조 방법은 일상적인 방사성 의약품의 제조에 적용이 가능하였으며, 방사성 의약품의 제조시간을 크게 단축시킬 수 있었다.

  • PDF

Mg 온간성형을 위한 십자형상 금형의 가열/냉각 채널 설계 (Heating and Cooling Channel Design of Cross-Shaped Die for Warm Forming of Magnesium Alloy Sheet)

  • 최선철;고동선;김헌영;김형종;홍석무;유수열;신용승
    • 한국소성가공학회:학술대회논문집
    • /
    • 한국소성가공학회 2008년도 춘계학술대회 논문집
    • /
    • pp.370-373
    • /
    • 2008
  • It is known that the temperatures of die, punch, holder and punch pad need to be kept different to get better formability in Mg sheet forming processes. Heating and cooling channels are usually equipped in each tool to assign different temperature. This study focused on the optimal design of the heating and cooling channels for a cross-shaped deep drawing die set. While the die and blankholder were heated to and kept at $250^{\circ}C$ by using heat cartridges, the punch and punch pad were kept at much lower temperature than that of the die and blankholder by water circulating through cooling channels. All the approaches were done by numerical analyses, aiming to maximize the cup height and to minimize the punch corner radius without any failure.

  • PDF

Determination of Heterocyclic Amines and Acrylamide in Agricultural Products with Liquid Chromatography-Tandem Mass Spectrometry

  • Lee, Kyung-Jun;Lee, Gae-Ho;Kim, HaeSol;Oh, Min-Seok;Chu, Seok;Hwang, In Ju;Lee, Jee-yeon;Choi, Ari;Kim, Cho-il;Park, Hyun-Mee
    • Toxicological Research
    • /
    • 제31권3호
    • /
    • pp.255-264
    • /
    • 2015
  • Heterocyclic amines (HCAs) and acrylamide are unintended hazardous substances generated by heating or processing of foods and are known as carcinogenic and mutagenic agents by the animal experiments. A simple method was established for a rapid and accurate determination of 12 types of HCAs (IQ, MeIQ, Glu-P-1, Glu-P-2, MeIQx, Trp-P-1, Trp-P-2, PhIP, $A{\alpha}C$, $MeA{\alpha}C$, Harman and Norharman) and acrylamide in three food matrices (non-fat liquid, non-fat solid and fat solid) by isotope dilution liquid chromatography-tandem mass spectrometry (LC-MS/MS). In every sample, a mixture of internal standards including $IQ-d_3$, $MeIQx-d_3$, $PhIP-d_3$, $Trp-P-2-^{13}C_2-^{15}N$ and $MeA{\alpha}C-d_3$ was spiked for quantification of HCAs and $^{13}C_3$-acrylamide was also spiked for the analysis of acrylamide. HCAs and acrylamide in sample were extracted with acetonitrile and water, respectively, and then two solid-phase extraction cartridges, ChemElut: HLB for HCAs and Accucat: HLB for acrylamide, were used for efficiently removing interferences such as pigment, lipid, polar, nonpolar and ionic compounds. Established method was validated in terms of recovery, accuracy, precision, limit of detection, limit of quantitation, and linearity. This method showed good precision (RSD < 20%), accuracy (71.8~119.1%) and recovery (66.0~118.9%). The detection limits were < 3.1 ng/g for all analytes. The correlation coefficients for all the HCAs and acrylamide were > 0.995, showing excellent linearity. These methods for the detection of HCAs and acrylamide by LC-MS/MS were applied to real samples and were successfully used for quantitative monitoring in the total diet study and this can be applied to risk assessment in various food matrices.