• Title/Summary/Keyword: Heating and Cooling System

Search Result 941, Processing Time 0.028 seconds

Study on the Collector Efficiency of an Air Heater in a Solar Air Conditioning System (태양열 이용 냉난방 공조시스템 중 공기식 집열기의 집열효율에 관한 연구)

  • Kim, B.C.;Shin, H.J.;Choi, K.H.;Kum, J.S.
    • Solar Energy
    • /
    • v.20 no.4
    • /
    • pp.1-8
    • /
    • 2000
  • The suggested year round solar air conditioning system has been developed for cooling and heating. In particular, this system focused on cooling and dehumidification and it could reduce a peak time owing to the use of air conditioners in summer. This study was performed to find out how much heating loads could be saved and furthermore whether this suggested system would be possible to do heating without a switch of system in real situations. Through model house experiments, the following conclusions were obtained. 1) The collector efficiency was 36% at maximum, but more improved structure of suggested collector could increase its efficiency. 2) The temperature of outlet air was about $30^{\circ}C$ and it could reduce heating loads. 3) Measured temperature and calculated one agreed well within ${\pm}1.5^{\circ}C$.

  • PDF

Capacity and Power Input Performance Curves Creation of Water-cooled VRF Heat Pump for EnergyPlus (EnergyPlus 해석용 수랭식 VRF 히트펌프의 냉·난방 능력 및 소비전력 예측식 산출 기법)

  • Kim, Min-Ji;Kwon, Hyuk-Joo;Lee, Kwang Ho
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.13 no.3
    • /
    • pp.1-8
    • /
    • 2017
  • Variable refrigerant flow (VRF) systems have recently attracted attention in many countries due to a variety of advantages over conventional system. Especially, the water-cooled VRF heat pump, including geothermal heat pump, is a system that accurately controls the flow rate of refrigerant for the improved efficiency under part load operation. This paper describe the process of generating the cooling and heating energy performance curve coefficients and performance expressions for modeling water cooled VRF system using EnergyPlus. Through this study, the process for generating performance curves can be implemented into EnergyPlus or other comparable building energy analysis tools for the long-term evaluation of heat pump under dynamic conditions.

Analysis of Economic Feasibility and Reductions of Carbon Dioxide Emission of Geothermal Heating and Cooling System using Groundwater (지하수를 이용한 지열 냉난방시스템의 경제성 및 이산화탄소 저감량 분석)

  • Kim, Jin-Sung;Song, Sung-Ho;Jeong, Gyo-Cheol;Cha, Jang-Hwan
    • The Journal of Engineering Geology
    • /
    • v.25 no.4
    • /
    • pp.599-612
    • /
    • 2015
  • The development of renewable energy technologies that can replace fossil fuels is environmentally important; however, such technologies must be economically feasible. Economic analyses are important for assessing new projects such as geothermal heating-cooling systems, given their large initial costs. This study analyzed the economics and carbon dioxide emissions of: a SCW (standing column well), a vertical closed loop boiler, a gas boiler, and an oil boiler. Life cycle cost analysis showed that the SCW geothermal heating-cooling system had the highest economic feasibility, as it had the highest cost saving and also the lowest carbon dioxide emissions. Overall, it appears that geothermal systems can save money when applied to large-scale controlled agriculture complexes and reclaimed land.

Performance Prediction on the Application of a Ground-Source Heat Pump(GSHP) System in an Office Building (업무용 건물의 지열 히트펌프 시스템에 대한 성능 예측)

  • Sohn, Byonghu;Kwon, Han Sol
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.26 no.9
    • /
    • pp.409-415
    • /
    • 2014
  • Ground-source heat pump (GSHP) systems have become an efficient alternative to conventional cooling and heating methods due to their higher energy efficiency. These systems use the ground as a heat source and the heat sink for cooling mode operation. The purpose of this simulation study is to evaluate the performance of a hypothetical GSHP system in an office building and to assess the energy saving effect against the existing HVAC systems (boiler and turbo chiller). We collected monthly energy consumption data from an actual office building ($32,488m^2$) in Seoul, and created a model to calculate the hourly building loads with EnergyPlus. In addition, we used GLD (Ground Loop Design) V8.0, a GSHP system design and simulation software tool, to evaluate hourly and monthly performance of the GSHP system. The energy consumption for the GSHP system based on the hourly simulation results were estimated to be 582.6 MWh/year for cooling and 593.2 MWh/year for heating, while those for the existing HVAC systems were found to be 674.5 MWh/year and 2,496.4 MWh/year, respectively. The seasonal performance factor (SPF) of the GSHP system was also calculated to be in the range of 3.37~4.28.

The Estimation of Heating, Cooling Load and Economical Efficiency Analysis of Insulation Paint Coating Windows (단열 도료 코팅 창호의 냉난방부하 특성분석 및 경제성 평가)

  • Jeong, Yeol-Wha;Kim, Byoung-Soo
    • Journal of the Korean Solar Energy Society
    • /
    • v.31 no.6
    • /
    • pp.95-102
    • /
    • 2011
  • The purpose of study is to estimate heating, cooling load performance and economic efficiency in office building with applied the functional paint. this paint can reduced SHGC(Solar Heat Gain Coefficient) on the glazing surface by coating. In this study, estimated to compared with double glazing, low-e glazing, IP(Insulation Paint) and IPu(Insulation UV-Cut Paint) coating glazing. As a result of this study, 1)heating & cooling load Analysis, SHGC value and U-factor of double glazing is about 0.70 and 3.29($W/m^2K$). low-E glazing is about 0.65 and 2.70($W/m^2K$). Two-side it is about 0.27 and 3.25($W/m^2K$). When compared to double glazing, annual heating & cooling load of low-E glazing, Two-side IPu and IP paint coating glazing is 3,012MWh($124kWh/m^2$), 2,910MWh($120kWh/m^2$), 2,867MWh($118.4kWh/m^2$) and 2,867MWh($118.4kWh/m^2$). It i sreduced to 2.0%, 5.2%, 6.7%, and 6.7% respectively. 2)the estimation of economic efficiency, low-e glazing installed in office building can not recover the investment within a lifetime 40years. but IPu and IP paint, two-side coating in glazing, have a payback period of 13 years respectively.

Failure Analysis of Welded type 304 in Cooling Water Pipeline of District Heating System (지역난방 냉각수 배관의 용접부 파손 분석)

  • Jeong, Joon-Cheol;Kim, Woo-Cheol;Kim, Kyung Min;Sohn, Hong-Kyun;Kim, Jung-Gu;Lee, Soo-Yeol;Kim, Heesan
    • Corrosion Science and Technology
    • /
    • v.19 no.6
    • /
    • pp.296-301
    • /
    • 2020
  • Failure analysis on the welded type 304 pipe used for cooling water piping in the district heating primary side was conducted. Inorganic elements and bacteria in the cooling water and in corrosion products were analyzed, and the weldment was inspected by microscopy and a sensitization test. Corrosion damages were observed in the heat-affected zone, on weld defects such as incomplete fusion or excessive penetration caused by improper welding, or/and at the 6 o'clock position along the pipe axial direction. However, the level of concentration of chloride in the cooling water as low as 80 ppm has been reported to be not enough for even a sensitized type 304 steel, meaning that the additional corrosive factor was required for these corrosion damages. The factor leading to these corrosion damages was drawn to be the metabolisms of the types of bacteria, which is proved by the detection of proton, sulfur containing species, biofilms, and both bacteria and corrosion product analyses.

The expectation of future cooling and heating degree day of the Seoul and Ulsan using HadCM3 (HadCM3를 이용한 서울 및 울산지역의 미래 냉.난방도일 예측)

  • Lee, Kwan-Ho;Yoo, Ho-Chun;Noh, Kyoung-Hwan
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2008.04a
    • /
    • pp.160-165
    • /
    • 2008
  • The concern in energy reduction in the field of architecture which takes up a big weight in domestic energy consumption is gradually increasing. For this reason, a lot of research work on this matter is being carried out. Particularly, it is generally required that currently used system in a structure for energy reduction should be maximized in its efficiency. In addition, research on several energy reduction typed systems is underway. Such a research work should not only include the one in time of the present but also keep up with the trend for future-oriented research. This research paper forecasted and analyzed the trend for global warming and demand of a structure for energy in the future by applying climate scenarios to cooling degree-day and heating degree-day. Also, this research found out the decrease in heating degree-days and increase in cooling degree-days until this moment due to the progress of global warming. In addition, as for heating degree-days in the future forecasted on the basis of HadCM3, it is estimated that the range of decrease could be ever bigger starting 2040 in case of Seoul and also starting 2010 in case of Ulsan ever after respectively. In case of cooling degree-days, it is estimated that its increase range could be bigger abruptly starting 2050, and after 2080, its increase range would be much bigger.

  • PDF

Improvement of Cooling Water Quality by Corrosion and Scale Inhibitor (부식 및 스케일 억제제에 의한 냉각수 수질향상)

  • Jo, Kwan-Hyung;Woo, Dal-Sik;Hwang, Byung-Gi
    • Journal of Environmental Science International
    • /
    • v.18 no.2
    • /
    • pp.187-195
    • /
    • 2009
  • This study was investigated to control the corrosion and scale at the cooling water system in steel works. Laboratory and field tests were performed for the indirect cooling water system of plate mill. Throughout the experiment, various factors such as leakage of pipes, heating rate and capacity, and the reaction between existing and substitute inhibitors were carefully monitored. The results showed that the harmful effect of high temperature could be minimized, and satisfactory corrosion/scale controls were effectively achieved using inhibitor, even at the increased temperature of $80^{\circ}C$. The batch and field tests in the gas scrubbing cooling water system of blast furnace and cooling water system of corex plant indicated that the new inhibitor was more effective for the prevention of corrosion and scale than the existing one.

Energy Saving Potentials of Dedicated Outdoor Air System in a High-rise Apartment Building (외기전담 시스템 기반 초고층 공동주택 중앙 환기시스템의 에너지 절감효과 분석)

  • Kim, Min-Hwi;Kim, Jin-Hyo;Kwon, Oh-Hyun;Jeong, Jae-Weon
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2009.11a
    • /
    • pp.291-296
    • /
    • 2009
  • This paper investigates the energy saving potentials of a dedicated outdoor air system (DOAS) applied to a highrise apartment building. As for a typical $132-m^2$ apartment unit, two different HVAC systems; centralized DOAS-Ceiling Radiant Cooling Panel and decentralized Energy Recovery Ventilator-Packaged Air Conditioner were installed. Transient behavior and control characteristics of each system were modeled numerically using a commercial equation solver program, and annual cooling coil load and heating load reduction potentials were compared. The research shows that DOAS-Ceiling Radiant Cooling Panel system can reduce the cooling coil load over 21% annually compared with the current Energy Recovery Ventilator-Packaged Air Conditioner pair. In addition, over 40% of annual ventilation heating load can be reduced by use of DOAS.

  • PDF

The Investigation of the Plasma Sprayed Coatings for the Application of OG Cooling Tube in Steel Making Plant

  • Kim, HyungJun;Kwon, YoungGak
    • Corrosion Science and Technology
    • /
    • v.4 no.1
    • /
    • pp.23-28
    • /
    • 2005
  • Several plasma-sprayed ceramic coatings with two- and three-layers were characterized and tested for the application of cooling tube coatings of oxygen convert gas recovery system (OG cooling system) in the steel making plant. Thermal cycling tests using a torch heating with compressed air cooling were carried out and characterized before and after the tests. The effects of metallic bond coat as well as ceramic top coat were also studied. Possible failure mechanisms with low carbon steel substrate were assessed in term of microstructure, porosity, bond strength, thermal expansion coefficient, and the phase transformation. Finally, the results of field tests at the OG cooling system are presented and discussed their microstructural degradation. Test results have shown that three-layered coatings perform better than two-layered coatings.