• 제목/요약/키워드: Heating and Cooling Operations

검색결과 34건 처리시간 0.024초

포스트 코로나 시대 신종 감염병 대비를 위한 기존 의료시설의 비상시 운영사례 조사 및 분석 (Investigations on the emergency operation status of existing medical facilities to prepare for emerging infectious diseases in the post-COVID-19 era)

  • 이세진;이원석;김은석;여명석
    • 의료ㆍ복지 건축 : 한국의료복지건축학회 논문집
    • /
    • 제29권1호
    • /
    • pp.43-51
    • /
    • 2023
  • Purpose: To accommodate the increasing number of patients during the COVID-19 pandemic, numerous portable HEPA filter units (PHUs) were installed in the general wards of existing medical facilities(EMFs) to convert them into emergency conversion facilities (ECFs). The purpose of this study was to build a dataset in preparation for emerging infectious diseases in the post-COVID-19 era by analyzing the construction and operation of ECFs. Methods: Field investigations were conducted during ECF operation periods based on the analysis of heating, ventilation, and air conditioning (HAVC) system design documents for six ECFs across Korea. Interviews were conducted with facility managers during the field investigations. Results: When constructing an ECF within an EMF, the installation status and characteristics of the existing system should be considered. Field investigations and verifications of the operation of HAVC systems must be conducted beforehand for smooth ECF operations. If heating and cooling are required with indoor air circulation type equipment in an ECF zone, the implementation of a heating and cooling method that can satisfy the comfort requirements of the occupants while minimizing cross-contamination is essential. When using PHUs that do not meet the performance standards required by medical equipment, the noise level resulting from such equipment operation must be evaluated and improved. Implications: For EMFs, various guidelines that can be referred to for the construction and operation of ECFs must be developed to prepare for emerging infectious diseases in the future.

지하수정호 결합 복합지열시스템의 시범운영 효과분석 (Analysis of Test Operations Effect of Open-Closed Loops Complex Geothermal System Combined with Groundwater Well)

  • 송재용;김기준;이근춘;정교철
    • 지질공학
    • /
    • 제28권3호
    • /
    • pp.475-488
    • /
    • 2018
  • 본 연구에서는 지하수 관정을 활용하고 밀폐형-개방형이 결합된 복합지열시스템(CWG 시스템)을 시설재배지에 적용하여 열원측 및 부하측의 열교환량과 투입된 전력량 대비 효율을 평가하였다. 또한, 운전 과정에서의 외기온도 및 시설재배지 온도를 평가하여 복합지열시스템 적용시의 냉난방 효과를 분석하였다. 냉방운전시 열원측 열교환량 평가결과, 약 235 L/min의 지하수가 유입되는 개방형에서 평균 90.0 kW/h, 약 85 L/min의 순환수가 유동하는 밀폐형에서 40.1 kW/h의 열교환량이 발생하였으며, 전체 열교환량은평균 130.1 kW/h로 분석되었다. 부하측에서 실질적으로 전달되는 열교환량은 평균 110.4kW/h로 평가되었다. 복합지열시스템의 냉방효율을 분석한 결과, 평균 EER는 5.63으로 분석되었다. 난방운전 시 열원측 열교환량 평가결과, 약 266 L/min의 지하수가 유입되는 개방형에서 평균 60.4 kW/h, 약 86 L/min의 순환수가 유동하는 밀폐형에서 22.4 kW/h의 열교환량이 발생하였으며, 전체 열교환량은 평균 82.9 kW/h로 분석되었다. 부하측에서 실질적으로 전달되는 열교환량은 평균 112.0 kW/h로 평가되었다. 복합지열시스템의 난방효율을 분석한 결과, 평균 COP는 3.92로 분석되었다. 외기온도와 CWG 시스템을 적용한 시설하우스 및 비교 시설하우스 내부온도와의 상관관계를 분석한 결과 30RT 용량의 CWG 시스템 하우스가 비교 하우스에 비해 외기온도 $20^{\circ}C$인 경우 $3.4^{\circ}C$, 외기온도 $25^{\circ}C$인 경우 $6.8^{\circ}C$, 외기온도 $30^{\circ}C$인 경우 $10.1^{\circ}C$, 외기온도 $35^{\circ}C$인 경우 $13.4^{\circ}C$의 온도가 저감되는 것으로 평가되었다. 이러한 결과를 볼 때, 본 시스템을 적용할 경우 일반적으로 외기온도가 $30^{\circ}C$ 이상을 보이는 여름철에 CWG 시스템을 적용하지 않은 시설재배지에 비해 약 $10^{\circ}C$ 이상의 냉방효과가 나타낼 수 있을 것으로 판단된다. 이와 같은 결과는 시설재배지의 복합지열시스템 설계에 활용될 수 있고, 다양한 조건에서의 시험성과와 종합하여 복합지열시스템의 냉난방 효과에 대한 보다 명확한 규명이 가능할 것으로 판단된다.

형상기억합금을 이용한 열박음 공구홀더 개발 (Development of Shrink-Fit Tool Holder using Shape Memory Alloys)

  • 신우철;노승국;김병섭;박종권
    • 한국생산제조학회지
    • /
    • 제19권6호
    • /
    • pp.889-894
    • /
    • 2010
  • Conventional shrink-fit tool holders have positive features, such as high accuracy, high strength, high stiffness and low sensitivity to centrifugal forces, but they require heavy investments for heating and cooling equipment. Generally the heating equipment has to heat the tool holder up to $200{\sim}300^{\circ}C$ for tool changes. This paper introduces a novel shrink-fit tool holder that is able to unclamp a tool at $40{\sim}50^{\circ}C$. This feature makes it possible to switch between the clamped and unclamped states by using a simple device, which has lower power, smaller size and lower cost than the heating equipment of the conventional shrink-fit tool holders. The proposed shrink-fit tool holder is able to expand its tool hole by using the shape memory alloys which are integrated in the tool holder body. Performances of the SMA shrink-fit tool holder were evaluated experimentally. The experimental results confirm that the proposed tool holder is feasible in aspects of clamping/unclamping operations, clamping force and repeatability of tool setup.

Distribution of Freshwater Organisms in the Pyeonggang Stream and Application Effects of Hydrothermal Energy on Variations in Water Temperature by Return Flow in a Stream Ecosystem

  • Dohun Lim;Yoonjin Lee
    • 자원환경지질
    • /
    • 제56권2호
    • /
    • pp.185-199
    • /
    • 2023
  • This study aimed to predict the effects of water ecology on the supply of hydrothermal energy to model a housing complex in Eco Delta Smart Village in Busan. Based on the results, engineering measures were recommended to minimize problems due to possible temperature variations on the supply of hydrothermal energy from the river. The current distribution of fish, benthic macroinvertebrates, and phytoplankton in the Pyeonggang Stream was monitored to determine their effects on water ecology. In the research area, five species and three families of fish were observed. The dominant species was Lepomis macrochirus, and the subdominant species was Carassius auratus. Twenty-five species and 21 families of benthic macroinvertebrates were found. The distribution of aquatic insects was poor in this area. The dominant species were Chironomidae sp., Lymnaea auricularia, Appasus japonicus, and Caridina denticulata denticulata in February, May, July, and October. Dominant phytoplankton were Aulacoseira ambigua and Nitzschia palea in February and May. Microcystis sp. was dominant in July and October. The health of the ecology the Pyeonggang Stream was assessed as D (bad) according to the benthic macroinvertebrate index (BMI). Shifts in the location of the discharge point 150 m downstream from intake points and discharge through embedded rock layer after adding equal amounts of stream water as was taken at the beginning were suggested to minimize water temperature variations due to the application of hydrothermal energy. When the scenario (i.e., quantity of water intake and dilution water, 1,600 m3/d and water temp. difference ±5 ℃) was realized, variations in water temperature were assessed at -0.19 ℃ and 0.59 ℃ during cooling and heating, respectively, at a point 10 m downstream. Water temperatures recorded at -0.20 ℃ and 0.68 ℃ during cooling and heating, respectively, at a point 10 m upstream. All stream water temperatures after the application of hydrothermal energy recovered within 24 hours. Future work on the long-term monitoring of ecosystems is suggested, particularly to analyze the influence of the water environment on hydrothermal energy supply operations.

Sensorless Control for a PM Synchronous Motor in a Single Piston Rotary Compressor

  • Cho Kwan-Yuhl
    • Journal of Power Electronics
    • /
    • 제6권1호
    • /
    • pp.29-37
    • /
    • 2006
  • A sensorless control for an IPM (Interior Permanent Magnet) synchronous motor in a single piston rotary compressor is presented in this study. The rotor position is estimated from the d-axis and q-axis current errors between the real system and a motor model of the position estimator. The torque pulsation of the single piston rotary compressor is compensated to reduce speed ripples, as well as, mechanical noise and vibration. The proposed sensorless drive enables the compressor to operate at a lower speed which increases energy savings and reduces mechanical noise. It also gives high speed operations by a flux weakening control for rapid air-cooling and heating of the heat pump air-conditioners.

형상기억합금 기반 공구클램핑 장치를 위한 자동공구교환 시스템 개발 (Development of Automatic Tool Change System of the SMA-Based Tool Clamping Device)

  • 신우철;노승국;김병섭;박종권
    • 한국생산제조학회지
    • /
    • 제19권5호
    • /
    • pp.710-715
    • /
    • 2010
  • This study developed an automatic tool change system of the SMA-based tool clamping device for applications of micro-machine tools. This paper first describes clamping and unclamping procedures of the automatic tool change system and its basic configuration. Second, it presents fabrication techniques of components, such as a heating/cooling system and a tool loader. Finally, it describes automatic tool change test conducted with a prototype in which the fabrication techniques of components were employed. As the results of the test, times needed for clamping and unclamping operations were estimated to 18(s) and 8(s) respectively. The experimental results confirm that the proposed automatic tool change system can be sucessfully applied to micro-machine tools.

머신러닝 기반 공장 HVAC 시스템의 에너지 효율화 운영 시뮬레이션 (Energy-Efficient Operation Simulation of Factory HVAC System based on Machine Learning)

  • 이석주;다어반권
    • 한국산업정보학회논문지
    • /
    • 제29권2호
    • /
    • pp.47-54
    • /
    • 2024
  • 현재, 전세계적으로 에너지 자원은 점차적으로 감소하고 있음에도 불구하고 에너지 수요 및 소비는 지속적으로 증가하고 있다. 이에 따른 에너지 자원을 대체하기 위한 범국가적인 노력 및 연구가 수행되고 있다. 에너지 수요에 따른 공급의 증가 뿐만 아니라 에너지를 효율적으로 소비하는 것은 현 에너지 부족 현상을 해결하기 위한 적절한 수단이 될 수 있다. 본 연구는 에너지를 가장 많이 소비하는 제조 공장의 에너지를 효율적으로 소비할 수 있는 방법을 시뮬레이션하고 분석하였다. 제조 공장에서 가장 많은 에너지를 소비하는 HVAC (Heating, Ventilating, and Air Conditioning) 시스템의 효율적인 운전을 위해 온도기반의 제어를 통한 공장의 에너지 최적화 시뮬레이션을 수행하였다. 이를 기반으로 실제 공장의 온도와 전력 데이터를 이용하여 머신러닝 알고리즘을 적용하고 공장 온도를 예측하였다. 또한 예측 온도를 이용한 제어 시스템 시뮬레이션으로 공장 에너지의 소비패턴을 분석하고 에너지(전력량) 소비량을 감소할 수 있는 운전 모델을 제안하였다. 공장 에너지 패턴에 있어 HVAC 시스템의 예측 기반 프리 쿨링을 통한 온도제어 알고리즘은 기존 대비 10% 이상의 에너지 절감 효과를 보여 준다. 이 결과는 HVAC 시스템의 최적 제어가 공장 에너지 소비를 절감할 수 있음을 나타낸다. 향후 본 제어 시스템의 알고리즘은 실제 공장의 최적 제어에 적용되어 에너지 소비 절감 운전을 수행할 예정이다.

필릿 용접부의 각변형량 예측에 관한 연구 (A study on the estimate of the angular distortion for a fillet weldment)

  • 양영수;이세환;조수형
    • Journal of Welding and Joining
    • /
    • 제15권4호
    • /
    • pp.63-69
    • /
    • 1997
  • Welding distortion is more serious problem than any other problems caused by welding process, especially, in the heavy-industrial place. These welding distortions are caused by nonuniform heating and cooling of metal during and after welding operations. And these distortion quantities are must be known to worker in production line because distorions are important role in assembling part. Therefore an analytical model to explain and predict the welding distortion are needed. A numerical analysis of welding distortion which is inelastic behavior of weldment would require the three dimensional calculation. But computing time and memory would be very large, and the resulting cost might be unacceptable. Therefore we use a numerical technique for two dimensional analysis in the section normal to the weld direction of weldment under an assumption of quasi-stationary conditions. But the result of the calculation under two dimensional(plane strain) assumption was not satisfied as compared with experimental result. This paper proposed a technique for analysing the welding angular distortion by using a constraint boundary condition on the two dimensional finite element model. The simulation results revealed that the constraint boundary model could more reasonably describe the welding distortion than the plane strain model did.

  • PDF

진동형 히트파이프 흡열판이 결합된 하이브리드 태양광/열 시스템 (Hybrid Photovoltaic/Thermal Solar System with Pulsating Heat Pipe Type Absorber)

  • 김창희;전동환;공상운;김종수
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회B
    • /
    • pp.2148-2153
    • /
    • 2007
  • The electricity conversion-efficiency of solar cell for commercial application is about 6-15%. More than 85% of the incoming solar energy is either reflected or absorbed as heat energy. Consequently, the working temperature of the photovoltaic cells increases considerably after prolonged operations and the cell's efficiency drops significantly. PV/T refers to the integration of a PV module and a solar thermal collector in a single piece of equipment. By cooling the PV module with a fluid steam like air or water, the electricity yield can be improved. At the same time, the heat pick-up by the fluid can be to support space heating or service hot-water systems. In this study, a pulsating heat pipe solar heat collector was combined with single-crystal silicon photovoltaic cell in hybrid energy-generating unit that simultaneously produced low temperature heat and heat and electricity. This experiment was investigating thermal and electrical efficiency for evaluation of a PV/T system.

  • PDF

지열 열교환시스템 개발을 위한 지중 열유동 특성분석 (Analysis of Heat Transfer Characteristics in Soil for Development of a Geothermal Heat Exchange System)

  • 이용범;조성인;강창호;정인규;이충근;성제훈;정선옥;김영복
    • Journal of Biosystems Engineering
    • /
    • 제30권3호
    • /
    • pp.185-191
    • /
    • 2005
  • Importance of alternative energy has been increasing due to environmental issues and lack of fossil fuels. In addition, heating cost that occupies from 30 to $40\%$ of the total production cost in the protected cultivation sector in Korea needs to be reduced for profitability and global competition. But, study on geothermal energy to solve these problems has not been activated for Korean protected cultivation. This study was conducted to develop an optimized geothermal exchange system through fundamental test of heat transfer characteristics in soil such as thermal diffusivity, changes in soil temperature during heating and cooling operations, and restorations of soil temperature after the heater was fumed off, These issues were investigated using computer simulation for different depths. The simulated characteristics were evaluated through controlled tests. Simulated characteristics of heat transfer in the soil at different depths showed a reasonable agreement with the results of the controlled tests. All of computer simulation and controlled tests, soil temperatures changed at 10cm and 20cm distance from pipe. but don't change at more than 30cm distance. It means that distances of heat transfer of the soil ranged from 20 to 30cm a day. Based on these results, the optimum spacing between adjacent heat exchange pipes and the pitch were selected as 50 and 40cm, respectively.