• Title/Summary/Keyword: Heating System

Search Result 3,598, Processing Time 0.027 seconds

Economic Analysis of Heat Pump System in Educational Building -Focused on the High School of Twenty Four Classes- (교육용 건축물의 히트펌프 냉난방시스템에 대한 경제성 분석 -24학급 규모의 고등학교를 중심으로-)

  • Park, Ryul;Park, Min-Yong;Kim, Jong-Min
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.10
    • /
    • pp.879-887
    • /
    • 2003
  • Buildings with heating and cooling systems have been increased, since the requirement of thermal comfort for residents is grown. Heating and cooling systems, have been changed from two separate systems to one multi-function system which includes both heating and cooling. Especially, heat pump heating and cooling system has been adopted for general classrooms in schools since education environment improvement project has been launched. This research suggests the best option for the heat pump heating and cooling system in educational buildings through economic assessments for four alternative systems based on electric heat pump (EHP) and gas engine driven heat pump (GHP), which are most widely used for elementary, middle and high schools. The model buildings are in the Y high school which has 24 classes of new construction building, which will be built soon. Annual energy consumption for alternative systems uses BECS 3.10, which can be used for system simulation.

An experimental study on the multiple parameter switching control for floor heating system (바닥 난방공간의 다인자 제어에 관한 실험적 연구)

  • Cho, S.H.;Tae, C.S.;Jang, C.Y.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.9 no.4
    • /
    • pp.472-483
    • /
    • 1997
  • An experimental facility consisting of two $3{\times}4.4{\times}3.8m$ rooms identical in construction is built. Each room has a control system and storage tank supplying hot water to the radiant floor heating system. The facility enables simultaneous comparision of two different control stratigies each implemented in a separate room. The operating performance of three kinds of flow control scheme is tested and compared in this study : (i) conventional on-off control based on feedback from room air temperature (ii) TPSC(two parameter switching control) (iii) TPOC(two parameter on-off control). Results show that TPSC and TPOC using room air and surface temperature sequentially as feedback signal to control hot water supply is the better temperature regulation scheme than conventional control based on feedback from only room air temperature. They are good candidates for the room with radiant floor heating system under continuous and intermittent heating mode.

  • PDF

Heating Performance Analysis of Ground-Source Heat Pump (GSHP) System using Hybrid Ground Heat Exchanger (HGHE) (하이브리드 지중열교환기 적용 지열 히트펌프 시스템의 난방 성능 분석)

  • Sohn, Byonghu
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.16 no.3
    • /
    • pp.8-16
    • /
    • 2020
  • This paper presents the heating performance analysis results of a ground-source heat pump (GSHP) system using hybrid ground heat exchanger (HGHE). In this paper, the HGHE refers to the ground heat exchanger (GHE) using both a surface water heat exchanger (SWHE) and a vertical GHE. In order to evaluate the system performance, we installed monitoring sensors for measuring temperatures and power consumption, and then measured operation data with 4 different load burdened ratios of the HGHE. During the entire measurement period, the average heating capacity of the heat pump was 37.3 kW. In addition, the compressor of the heat pump consumed 9.4 kW of power, while the circulating pump of the HGHE used 6.7 kW of power. Therefore, the average heating coefficient of performance (COP) for the heat pump unit was 4.0, while the system including the circulating pump was 2.7. Finally, the parallel use of SWHE and VGHE was beneficial to the system performance; however, further researches are needed to optimize the design data for various load ratios of the HGHE.

Cooling and Heating Performance Evaluation of a Ground Source Heat Pump (지열원 열펌프의 냉.난방 성능 평가)

  • Sohn, Byong-Hu;Cho, Chung-Sik;Shin, Hyun-Joon;An, Hyung-Jun
    • Proceedings of the KSME Conference
    • /
    • 2004.04a
    • /
    • pp.2117-2122
    • /
    • 2004
  • The main objective of the present study is to investigate the performance characteristics of a ground source heat pump (GSHP) system with a 130 m vertical 60.5 mm nominal diameter U-bend ground heat exchanger. In order to evaluate the performance analysis, the GSHP system connected to a test room with 90 $m^2$ floor area in the Korea Institute of Construction Technology ($37^{\circ}39'$ N, $126^{\circ}48'$ E) was designed and constructed. This GSHP system mainly consisted of ground heat exchanger, indoor heat pump and measuring devices. The cooling and heating loads of the test room were 5.5 and 7.2 kW at design conditions, respectively. The experimental results were obtained from July to January in cooling and heating season of $2003{\sim}2004$. The cooling and heating performance coefficients of the system were determined from the experimental results. The average cooling and heating COPs for the system were obtained to be 4.82 and 3.02, respectively. The temperature variations in ground and the ground heat exchanger surface at different depths were also measured.

  • PDF

The Affordance of the Floor Heating System in Children's Libraries (어린이 도서관에 있어서 바닥 난방시스템의 지원성)

  • Lee, Jeong-Mi;Kwack, Dong-Wha
    • Korean Institute of Interior Design Journal
    • /
    • v.17 no.3
    • /
    • pp.77-85
    • /
    • 2008
  • The purpose of this study is to examine how the floor heating system is affecting to users in childeren's libraries. This study included the method that extracts the affordance of the floor heating system, after surveyed using behavior in children's libraries and referred to J. J. Gibson's affordance and surface concepts. As the positive affordance, it was grasped that the floor heating system promotes social relationships and affords various surfaces for library using, but also as the negative affordance, that hinders users in the public usings and the behaviors for reference and using. The behaviors of these various characters can be regarded as life behaviors resulted from the sitting life style and the natural using behavior can give to children emotional rest and autonomous reading experience. For the function as the children's library, the learning of sociality in the public building and the various reading space, the space planning of children's library should be done after the positive and negative affordances extracted from this study are reflected. The guidelines for space planning are summarized as the followings: the layout of book furniture, the shoe chest and the space around that, the furniture hight and children's eye level, and the practical using of the table for sitting life style.

Thermal Performance Evaluation of Movable Insulation System in Apartments (공동주택 발코니창에 설치된 가동단열 시스템의 열성능 평가)

  • Yoon, Jong-Ho;Kim, Byoung-Soo
    • Journal of the Korean Solar Energy Society
    • /
    • v.28 no.5
    • /
    • pp.28-35
    • /
    • 2008
  • The aim of this study was to analysis the Heating/cooling performance of movable insulation system built in apartments. The process of this study is as follows: 1) Test-cells of movable insulation are designed through the investigation of previous paper and work. The type of the movable insulation used in test-cell is low emissivity(5%) insulation, measured for heating season and the thermal effects are analyzed. 2) The simulation program(Design Builder) was used in energy performance analysis. the reference model of simulation was made up to analysis energy performance on movable insulation system. 3) Selected reference model(Floors:15, Area of Unit:115.5$m^2$) for heating/cooling energy analysis, Energy performance simulation with various variants, such as slate angle of movable insulation(5$^{\circ}$, 30$^{\circ}$, 50$^{\circ}$) and position of movable insulation. Consequently, When movable insulation system is equipped with balcony window of Apartment, Annual heating energy of reference model was cut down at the average of 5.4kWh/$m^2$ or 4.6% of heating/cooling energy.

A Simulation Study on Effect Analysis of EMS Combined Control of Central Cooling and Heating System (중앙냉난방시스템의 EMS 복합제어 효과 분석에 관한 시뮬레이션 연구)

  • Jae-Yeob Song;Byung-Cheon Ahn
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.18 no.4
    • /
    • pp.33-44
    • /
    • 2022
  • In this study, we analyze the existing heating and cooling operation method for an office-type complex building with a central heating and cooling system, and examine the effects of applying various EMS that can be applied according to the load size to save energy in the building. For this purpose, simulation analysis was performed. As a control method, reset control of chilled water, hot water, cooling water and supply air temperatures, optimal start/stop of heat source, and number of heat source control were applied according to the load size, and energy consumption was analyzed accordingly. In addition, when all of these control methods were applied, the overlapping energy saving effect was finally confirmed. As a result, it was possible to confirm the energy saving effect when EMS for reset control and heat source control were applied compared to the existing control method of the heating and cooling system, and the effect for the case of using all these control methods in combination was also confirmed.

Evaluation of the Heating and Cooling Systems in School Buildings (학교건물 냉난방설비시스템의 실태조사)

  • AHN, Chul-Lin;KIM, Dong-Gyue;KUM, Jong-Soo;PARK, Jong-Un;PARK, Hee-Ouk;CHUNG, Yong-Hyun
    • Journal of Fisheries and Marine Sciences Education
    • /
    • v.17 no.1
    • /
    • pp.18-25
    • /
    • 2005
  • We have researched 10,811 schools to evaluate the characteristics of school buildings and the conditions of heating and cooling systems at the elementary, middle and high school levels. Air conditioning systems in school buildings are related to school scale, and 35% of the researched schools have less than 10 air conditioned classrooms among all of the schools in Korea. The LOADSYS is used to grasp the characteristics of school buildings heating and cooling load. From the results of this work, the heating load differs by nearly 24% between Seoul and Busan, but other than that there are not so many serious regional differences. Almost 85.4% of the classrooms are equipped with heating facilities and 6.9% of them are equipped with heating and cooling facilities. As a result, it is necessary to make improvements in 31.8% of the classrooms using only heaters and 14.6% of the classrooms not equipped with HVAC. The survey shows that there is a wide gap in the heating equipment status of the classrooms according to the region and school district.

A Study on the Characteristics of Management Costs of Apartment Complexes by the Types of Heating Systems (난방방식에 따른 아파트 관리비용의 실태에 관한 연구 - 대전광역시를 대상으로 -)

  • Koh, Bong-Sung;Kim, Sang-Ho
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.7 no.3
    • /
    • pp.607-615
    • /
    • 2012
  • The aim of the study is to estimate the management costs of apartments by the types of heating systems(individual, central, district heating system). Multiple regression analysis was adapted and the used data are derived from 128 apartment complexes in Daegeon-si. The results are as follows; first, the management cost is decreased as a size of apartment is larger, second, the costs of general maintenance, security and repairing of buildings are lower in individual heating system. however, there is no significant differences in cleaning costs by the types of heating systems.

Study on the Application of Microwave-heating System for Making Bent-wood Furniture(II) - Bending Processing Properties of Carpinus laxiflora BL. by Microwave-heating - (국산재(國産材) 곡목가구(曲木家具) 제조(製造)를 위한 Microwave-heating System 활용(活用)에 관한 연구(硏究)(II) - Microwave-heating에 의한 서어나무의 소재(素材) 휨가공특성 -)

  • So, Won-Tek
    • Journal of the Korean Wood Science and Technology
    • /
    • v.25 no.2
    • /
    • pp.52-60
    • /
    • 1997
  • Hornbeam trees(Carpinus laxiflora BL.) are growing in Korea and have good characteristics such as relatively high density, fine texture, split- resistance, and white colour. However, they have seldom been used as manufacturing materials This study was carried out to evaluate the possibility of using hornbeam wood as bent, wood furniture materials. Softening methods were steaming and micro-wave heating. The specimens of $15{\times}15{\times}350mm$ were used green or air-dried, and were steamed at $100^{\circ}C$ for 20min, or microwave heat ed f or 60 seconds. The bending processing conditions are showed in Table 3. The minimum solid-bending radii of air-dried wood were 40mm for steaming and 200mm for micro-wave heating, respectively. And that of green wood were 40mm for micro-wave heating. In conclusion, both of the steamed wood and micro-wave heated green wood showed very good solid bending processing properties, but micro-wave heated air-dried wood were not sufficient for bent-wood furniture.

  • PDF