• Title/Summary/Keyword: Heating Rate

Search Result 1,912, Processing Time 0.028 seconds

Effect of Heating on the Sex Maturation and Egg Development of the Ark Shell, Scapharca Subcrenata (가온사육에 의한 새꼬막, Scapharca subcrenata의 성 성숙 및 난 발생)

  • Jung, Choon-Koo;Oh, Bong-Se;Kim, Tae-Ik;Jin, Young-Guk
    • The Korean Journal of Malacology
    • /
    • v.26 no.3
    • /
    • pp.201-209
    • /
    • 2010
  • The investigated of survival rate, sex ratio, condition index, gonad development frequency, gonad index, fertilization rate, hatching rate and time required development of D shape larvae of the ark shell, Scapharca subcrenata. Survival rate was lower in heating group compared with control group (P < 0.05). Sex ratio (female:male) observed 1:0.97 in control group, 1:0.62 in heating group. Condition index was significantly higher in heating group than control group (P < 0.05) and higher increased more than water temperature $17^{\circ}C$ of heating group. Gonad development observed slow in control group but more than ripe stage 80% in heating group (21-28 day, $20^{\circ}C$). Gonad index was higher in heating group compared with control group (P < 0.05). Fertilization rate and hatching rate of the ark shell was observed $82.17{\pm}3.55%$ and $63.57{\pm}2.36%$, respectively. The time required development of D shape larvae of the ark shell was observed 15 hour after fertilization. The suggested that results of the ark shell by heating were effective sex maturation and normal egg development.

Control Characteristics with Flow Rate Control Methods in Central Heating System (중앙난방시스템의 유량제어방식에 따른 제어특성 연구)

  • Song, Jae-Yeob;Ahn, Byung-Cheon
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.7 no.1
    • /
    • pp.32-37
    • /
    • 2011
  • In this study, control characteristics and energy performance with flow rate control methods were reviewed with the simulation. The heating system is classified such as fan coil unit and HVAC system currently used in buildings with valve control and pump inverter control. The simulation analysis program is made by TRNSYS ver. 15 with the actual data. As a result of this study, the central heating system with pump inverter control decreases electricity energy and reduces gas consumption. Inverter control method shows better performance in comparison with valve control one for energy saving.

The Changes in Quality of Sugars Chestnuts by Sugars and Heating Methods (당의 종류 및 가열방법에 따른 당침밤 제품의 품질 변화)

  • 홍순갑;황태영
    • Food Science and Preservation
    • /
    • v.4 no.2
    • /
    • pp.173-180
    • /
    • 1997
  • The effects of sugars and heating methods on the sugar infilteration, hardness, color and organoleptic characteristics were investigated for quality improvement of sugared chestnuts. Among the tested sugars, isomaltooligosugar was the most effective on the rate of sugar infilteration. High temperature increased the rate of sugar infilteration during sugaring process, but color and flavor were deteriorated at 9$0^{\circ}C$. The most suitable temperature for sugaring process was 7$0^{\circ}C$. The product sugared with fructooligosugar recoreded the highest score in hardness, odor and preference than any other sugars tested and increased the rate of sugar infilteration when mixed with sugar at same amount. The changes of soluble solids in chestnuts boiled with microwave oven were ranged from 18。Brix to 32。Brix, while chestnuts heated in general were from 18。Brix to 28。Brix. Chestnuts boiled with microwave heating were sugared rapidly. The hardness of boiled and sugared chestnuts was lower when treated with microwave than with general heating. Hunter's L and b value of sugared chestnut treated with microwave decreased during processing but a value somewhat increased.

  • PDF

Transport Phenomena in a Steam Methanol Microreformer for Fuel Cell (마이크로 연료전지용 수소개질기내 전달현상 특성 연구)

  • Suh, Jeong-Se
    • Proceedings of the SAREK Conference
    • /
    • 2008.11a
    • /
    • pp.3-8
    • /
    • 2008
  • Effect of external heating rate on the conversion efficiency for the steam reforming of methanol is investigated numerically considering both heat and mass transfer of the species in a packed bed microreactor. In a results from the numerical simulation, the conversion efficiency of methanol has been obtained for the external heating rate. The axial variation of mole fraction of methanol has been additionally presented for several cases of external heating rates. The results show that for the constant inlet temperature condition the conversion efficiency of methanol increases with external heating rate over the range of operating conditions.

  • PDF

Melting of Ice Inside a Horizontal Cylinder under the Volume Change (수평원관내 체적변화를 고려한 얼음의 용용시 전열특성에 관한 연구)

  • 조남철;김동춘;이채탈;임장순
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.12
    • /
    • pp.1266-1274
    • /
    • 2001
  • Heat transfer phenomena during melting process of the phase change material (ice) was studied by numerical analysis and experiments. In a horizontal ice storage tube, the natural convection caused an increase in melting rate. However, the reduction of the heating surface area caused a decrease in melting rate. Therefore, during the melting process of ice in a horizontal cylinder, the reduction of the heating surface area should be considered. Under the same heating wall and initial water temperature condition, the melting rate became higher for $V_s/V_tot/=0.545 \;than \;that\; for\; V_s/V_tot$/=1.00 due to the difference in the reduction of heating surface area. A modified melting model considering the equivalent thermal conductivity of liquid phase and volume reduction was proposed. The results of the model were compared with the measured values and found to be in good agreement.

  • PDF

Effects of sintering conditions of (Cd+Te) films on the properties of sintered CdS/CdTe solar cells ((Cd+Te)막의 소결조건이 CdS/CdTe 태양전지의 특성에 미치는 영향)

  • 노재성;임호빈
    • Electrical & Electronic Materials
    • /
    • v.1 no.1
    • /
    • pp.26-34
    • /
    • 1988
  • Sintered CdS/CdTe solar cells have been farbricated by coating a (Cd+Te) slurry on sintered CdS films followed by the sintering at 625.deg.C for one hour with various heating rates. When cadmium and tellurinm powders are used instead of CdTe powder to form CdS/CdTe junction, CdTe is formed in the temperature range of 290.deg.C-400.deg.C. The microstructure of the CdTe films depends strongly on the heating rate of the sintering due to the low melting temperature and the high vapor pressure of the elemental Cd and Te. An optimum heating rate obtain CdTe films with uniform and dense microstructure which, in turn, improves the efficiency of the sintered CdS/CdTe solar cells. All-polycrystalline CdS/CdTe solar cells with an efficiency of 9.57% under 50mW/cm$^{2}$ tungsten light have been farbricated by using a heating rate of 14.deg.C/min.

  • PDF

An experimental study of defrosting behaviors on the fin-tube heat exchanger with PTC heating sheet (PTC 전열시트를 사용한 핀-관 열교환기의 제상 특성에 관한 실험적 연구)

  • Jhee, S.;Lee, K.S.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.11 no.1
    • /
    • pp.147-155
    • /
    • 1999
  • In this work, the defrosting characteristics of PTC heating sheet used as a defrosting heat source of fin-tube heat exchanger in a refrigerator have been experimentally compared with those of conventional electric heater. It is found that the characteristics of water draining rate with defrosting time show smoothly oscillating pattern when PTC heating sheet is used, and the drained water is completely melted. The defrosting efficiency of the PTC heating sheet is about 75%, which represents about 25% higher than that of the electric heater. A reduction of defrosting time and an increase of defrosting efficiency may be obtained by improving the arrangement of heating elements of the heating sheet. It is shown that the defrosting time of PTC heating sheet increases linearly with the amount of frost, however the defrosting efficiency is nearly constant. In the application to the refrigerating system, one should notice the fact that the defrosting performance of PTC heating sheet may be defraded due to the repeated operations.

  • PDF

Solar District Heating System (지역난방용 태양열시스템)

  • Baek, Nam-Choon;Lee, Jin-Kook;Yoon, Eung-Sang;Yoon, Suk-Man;Sin, U-Chul
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.663-668
    • /
    • 2008
  • This study was carried out solar heating system design for district heating and it's the performance analysis by experiment. This experimental system was installed in Bundang district heating area in the end of 2006. The flat plate and vacuum tube solar collector are combined in one system. So district heating water is heated first by flat plate solar collector and than by vacuum tube solar collector. This solar heating system has not a solar buffer tank and is operating with variable flow rate to obtain a setting temperature of $90{\sim}95^{\circ}C$. As a result, the daily solar thermal collection efficiency is about 30 to 40% for the plate type and 50 to 55% for the vacuum tube solar collector. It varied especially depend on the weather condition like as solar radiation and ambient temperature. This variable flow rate system can be also reduced much pumping power more than 50%.

  • PDF

Fabrication of Lightweight Aggregates Using Sewage Sludge and RFCC (하수슬러지와 페촉매를 원료로한 경량골재의 제조)

  • ;;dladydan
    • Resources Recycling
    • /
    • v.8 no.4
    • /
    • pp.3-10
    • /
    • 1999
  • An experimental study for manufacturing lightweight aggregates from sewage sludge ash of sewage treatment facilities was carned out in senses of sludge disposal and utilization. In case of SA alone, aggregates with S.G. 1.67 was obtained at sintering temperature of $1250^{\circ}C$, and heating rate affects little to volume expansion rate and volume expansion rate was decreased more or less by heating time. In case of adding 10 wt% of RFCC to SA, lightweight aggregates with S.G. 1.07 was obtained and volume expansion rate was increased by heating time. The optimum adding amounts of RFCC to manufacture lightweight aggregates was 10wt% and the condition that shows maximum volume expansion rate was $20^{\circ}C/min$ of heating rate, $1250^{\circ}C$ of sintering temperature and 50 mmutes of heating time. According to adding amounts of RFCC, Compressive strength of sample results in 30 wt% RFCC>SA>20 wt% RFCC>10 wt% RFCC.

  • PDF

A Study on the Optimal Water Flow Rate of the Solar Heating System (태양열 난방시스템의 최적 유량에 관한 연구)

  • Seong, Kwan-Jae;Kim, Hyo-Kyung
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.12 no.1
    • /
    • pp.2-11
    • /
    • 1983
  • The solar energy retention rate of a flat plate collector can be increased by increasing water flow rate through the collector which also increases the pumping energy incurred in obtaining that solar energy. The problem of optimal flow rate is formulated to fit within the framework of pontryagin's maximum principle and with a few simplifying assumptions, an optimal solution that can be easily implemented is obtaincd, The optimal solution is used in the simulation of a solar heating system using actual climatological data and the results are compared with that of on-off control. The result that not only the object function but, In some cases, also the solar energy retention rate the collector is increased. In is also found that the optimal control gets more advantageous as the solar insolation level gets lower, and also as tile cost of auxiliary heating fuel gets higher.

  • PDF