• Title/Summary/Keyword: Heating Period

Search Result 543, Processing Time 0.024 seconds

Changes in Level of Several Functional Components and ACE-Inhibitory Activity in Developing Soybean Seeds

  • Jun Woo-Jin;Lee Ji-Hyun;Shim Sang-In
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.51 no.4
    • /
    • pp.329-333
    • /
    • 2006
  • Soybean quality is determined based on protein content, lipid content and fatty acid composition, and several functional components including isoflavones, anthocyanins and functional activity. Because the level of each component changes during seed development, it is necessary to know the concentration of quality-related components in developing seeds. Little is known of the pattern of changes in quality-related components. Seeds from field-grown soybean was harvest from the $R_6$ stage to the $R_8$ stage in 2004. Seed characteristics and the level of nutritional components were examined. Seed moisture content was dropped rapidly after the $R_7$ stage in the tested varieties. Seed growth rate was the highest from the beginning of the $R_6$ stage to the mid-$R_6$ stage. Chlorophyll content was decreased rapidly in pods and seeds. However, seed growth period from the $R_6\;to\;R_8$ was 35 days. The crude protein content was. increased dramatically between 63 DAF and 70 DAF and then increased slightly. The pattern of isoflavone accumulation was nearly similar to that of seed weight increase. From the late $R_6$ stage to the $R_7$, the accumulation rate was higher as compared to other stages. The angiotensin inhibitory activity was increased according to seed development from 63 ($R_6$) to 84 DAF ($R_8$). The difference of inhibitory activity in heated soybean powder, however, was not great among stages. The inhibitory activity was affected by heating treatment. The most effective heating time was 10 min. Excessive heating longer than 30 min resulted in a lowered inhibitory activity of soybean on ACE.

A Study on the Comfort, Physiological Responses and Microclimate in Beding Pad (온돌에서의 욕의 쾌적성에 관한 연구)

  • Lee Soon Won;Kweon Soo Ae
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.14 no.1 s.33
    • /
    • pp.44-54
    • /
    • 1990
  • The purpose of this study was to investigate the effects of thickness of the sleeping pad on the physiological responses and the microclimate in the heating ondol room during sleeping time. The measuring points were skin temp., weight loss and body movement as physiological responses and the compression ratio, the temp. on/under the sleeping pad, the inside limp. of the sleeping quilts and subjective sence while 7 hours sleeping. Thickness of sleeping pads was 27.2 mm(A), 34.8 mm (B), 47.9 mm(C) used for 90 days and no used pad 60.7 mm(D). The floor surface temp. was keeping $29{\pm}1^{\circ}C$ while the environmental conditions was at $23{\pm}1^{\circ}C$ ($50{\pm}5\%$ R.H.) The results were as followings; 1) The mean compression ratio after using the sleeping pads for 45 days was about $70\%$ , and it wasn't increased any more thereafter 2) After 2 hours sleeping the temp. under the sleeping pads was shown that C and D were higher than A and B, and the temp. on the sleeping pads was shown that A and C pads were higher than B and D. But after 3-4 hours sleeping the skin temp. of legs was shown that B and D pads were higher than A and C. 3) Weight loss for C pad was significantly higher than others. Body movement and side position in tying was higher in A and C pads than B and D. 4) The inside temp. of quilt for A and C pads were higher in the early part of sleeping period than those of B and C pads and relative humidity was lower in C than others. 5) D pad was softer than others and fatigue degree was turned out to be lowest in D, the highest in A. From this point of view, we concluded that thickness of the sleeping Pad in the heating ondol room had different characteristic from that in no heating ondol room. And 35 mm used pad was turned out to be proper.

  • PDF

Effect of Soil Heating and Lateral Branching in White Spined Cucumbers (지중가온이 백침계 오이의 측지 발생에 미치는 영향)

  • Sang Gyu Lee;Ki Cheol Seong;Kwan Dal Ko;Kwang yong Kim
    • Journal of Bio-Environment Control
    • /
    • v.10 no.3
    • /
    • pp.155-158
    • /
    • 2001
  • The cultivation area of white spined cucumbers for export has continuously increased up to 121 ha in 2000. Since white spined cucumbers set fruits on lateral shoots, fruit yield is dependent upon the development of lateral shoots. Unfortunately, the major cultivation period is during winter season, October to February, when temperature and light are limited for the development lateral shoots. This experiment was conducted to investigate the effect of soil heating on the development of lateral shoots in white spined cucumbers. Number of lateral shoots were 13.7 and 11.7 in the soil heated treatment and in the control, respectively. Number of marketable fruits per plant was 45 in the soil heated treatment as compared to 38 in the control. Fruit yield was 81 ton per ha, an 18% increase, in the soil heated treatment. Soil heating not only increased number of long lateral shoots but also decreased curved fruits.

  • PDF

Verification Experiment and Analysis for 6kW Solar Water Heating System (Part 4 : Comparing Economics and Raising Competitiveness) (6kW급 태양열 온수급탕 시스템의 실증실험 및 분석 (제4보 경제성비교 및 경쟁력강화))

  • Lee Bong Jin;Kang Chaedong;Lee Sang Ryoul;Hong Hiki
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.17 no.3
    • /
    • pp.232-242
    • /
    • 2005
  • It has been recognized that solar water heating systems are economically inferior to conventional gas water-heaters and boilers using light oil as fuel in spite of having practical possibilities among other alternative energy facilities in Korea. The solar system, however, should be revaluated due to the sharp rise of oil prices recently. We have calculated the energy amount and cost through a series of research projects for the system by experiment and simulation, which lead to analyzing reliable life cycle costs. For the economic analysis, the gas water-heater and light oil boiler were taken as base cases while the solar systems implemented with these facilities were compared as alternatives. As a result, the solar system using the light oil as an auxiliary fuel surpassed the light oil boiler in economics. And a $50\%$ government subsidy for the initial cost is needed to maintain competitiveness with the gas hot-water heater. With this support, the simple payback period of the system can approach 12.8 years under $20\%$ additional curtailment of expenditure.

Development of a Conversion Unit converting the existing air conditioner to Heat Pump System for the Emergency Shelter (재해임시주거 냉난방을 위하여 기존 에어컨을 열펌프로 전환하는 변환기 개발)

  • Song, Heon
    • Journal of the Korean Solar Energy Society
    • /
    • v.31 no.5
    • /
    • pp.77-84
    • /
    • 2011
  • Korea and some other countries located in the northern hemisphere employ the air conditioner for the space cooling in the hot summer season and also some kinds of heaters for the space heating in the cold winter season. Especially in Korea, a great number of air conditioners of about 12,700,000 sets have been used these days. However, they are used for a short operation period of only 58 days a year, which results in the material and economic losses. To solve this problem and employ this system for the emergency shelter, a new conversion unit which could convert the existing air conditioner to a heat pump system for simultaneous heating and cooling was developed in this study, and the thermal performance was tested. The results indicated that the indoor air could be heated from $27^{\circ}C$ to $39^{\circ}C$ by the air conditioner converted to a heat pump system with the ambient temperature variation of $-10^{\circ}C{\sim}10^{\circ}C$, and cooled from $20^{\circ}C$ to $15^{\circ}C$ by the converted system with the ambient temperature variation of $20^{\circ}C{\sim}35^{\circ}C$. And also the heating COP increased from 3.3 to 5.3 in case of the heat exchange of the super cooling(HESC) circuit and from 3.0 to 4.0 in case of the By-pass with the ambient temperature variation of $-10^{\circ}C{\sim}10^{\circ}C$, respectively, whereas the cooling COP decreased from 3.1 to 2.1with the increase of the ambient temperature from $20^{\circ}C$ to $35^{\circ}C$.

Characteristics of the Seasonal Variation of the Radiation in a Mixed Forest at Kwangneung Arboretum (광릉수목원 혼합림에서 복사 에너지의 계절 변화 특성)

  • 김연희;조경숙;김현탁;엄향희;최병철
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.19 no.3
    • /
    • pp.285-296
    • /
    • 2003
  • The measurement of the radiation energy, trunk temperature, leaf area index (LAI), air temperature, vapor pres-sure, and precipitation has been conducted under a mixed forest at Kwangneung Arboretum during the period of 2001. Characteristics of the diurnal and seasonal variation of the radiative energy were investigated. The aerodynamic roughness length was determined as about 1.6 m and the mean albedo was about 0.1 The downward short-wave radiation was linearly correlated with the net radiation and its correlation coefficient was about 0.96. From this linear relation, the heating coefficient was calculated and its annual mean value was about 0.21 The albedo and heating coefficient was varied with season, surface characteristics, and meteorological conditions. The diurnal and seasonal variations of radiation energy were discussed in terms of the surface characteristics and meteorological conditions. In the daytime, during clear skies, net radiation was dominated by the shortwave radiation. In presence of clouds and fog, the radiation energy was diminished. At night, the net radiation was entirely dominated due to the net longwave radiation. There was no distinct diurnal variation in net radiation flux during the overcast or rainy days. The net radiation was strongest in spring and weakest in winter. The seasonal development in leaf area was also reflected in a strong seasonal pattern of the radiation energy balance. The timing, duration, and maximum leaf area and trunk temperature were found to be an important control on radiation energy budget. The trunk temperature was either equal or warmer than air temperature during most of the growing season because the canopy could absorb a substantial amount of sunlight. After autumn (after the middle of October), the trunk temperature was consistently cooler than air temperature.

Observations on the heating of grain caused by insects

  • Chyun Soon Pyo
    • Korean journal of applied entomology
    • /
    • v.3
    • /
    • pp.15-19
    • /
    • 1964
  • 1. The heat output by the insects, Oryzaephilus surinamensis, Tribolium confusum, Sitophilus zeamais and Sitophilus granarius, was investigated by reading the temperature of the inside of the grain in which the insects were developing in 2 Ib or 7 Ib jars incubated at $25^{\circ}C\; and\; 70\%$ R.H. 2. All the insects tested increase the temperature of grain, but the amount of heat produced by insects varies with the species of and the developmental stages of the insects. 3. It was found that all the temperature peaks correspond with the peak in number of the fourth instar larvae and the period in which the insects start to cause the heating corresponds to its 1 st and 2nd instar larvae. 4. Sitophilus spp. whose larvae live in the endosperm of the wheat produced more heat than Tribolium confusum and Oryzaephilus surinamensis whose larvae live on the grain. 5. Among the four species of insects, Sitophilus zeamais Produces the highest heat, followed by Sitophilus granarius, Tribolium confusum and Oryzaephilus surinamensis. 6. It is considered from the above results that the heat produced by insects seems to depend upon the species, the number and the age structure of population, and its its surroundings. 7. It is suggested therefore that when comparing the rate of development of insects kept at different densities. the effects caused by heating at the higher densities must be considered.

  • PDF

An Assessment of Korean Housewives Exposed to Polycyclic Aromatic Hydrocabons(PAHs) in Indoor Air (일부 주부의 실내공기 중 PAHs 노출에 관한 연구)

  • Lee, Tae-Hyung;Kim, Yun-Sin;Son, Bu-Soon
    • Journal of Environmental Science International
    • /
    • v.16 no.3
    • /
    • pp.323-331
    • /
    • 2007
  • Polycyclic aromatic hydrocarbons (PAHs) are well known for strong carcinogen. However, the human exposure analysis of PAHs is quite difficult and unreliable because of hard for estimation of actual expose dose. Then urinary 1-hydroxypyrene (1-OHP) has been a biological marker of exposure to PAHs. The purpose of this study was to investigate total amount from exposure to PAHs soused by indoor occupational exposure, and residence at Seoul metropolitan area and Kyeonggi province in Korea. Thirty-five housewives were included in this study from April 2003 through February 2004. Dietary habit and general characteristics such as age, type of building, existence of passive smoking, period of residence, fuel type for heating and ventilation type were obtained by self administered questionnaire. Urine samples were collected at morning and freeze quickly. Urinary creatinine was measured for converting into 24 hr urine. Concentration of the indoor PAHs was examined by NIOSH method number 5506. Urinary 1-OHP and PAHs were analysed by HPLC. Correlation coefficient between urinary 1-OHP levels and pyrene concentration of indoor air was 0.66 and statistically significant(P<0.01). The difference of urinary 1-OHP level due to dietary habits were not significant. Urinary 1-OHP level of Spring, Summer, Autumn, and Winter were $0.21{\pm}0.12,\;0.10{\pm}0.17,\;0.16{\pm}0.12,\;0.17{\pm}0.14{\mu}g/g$ cr, respectively. The arithmetic means of urinary 1-OHP for four season tee $0.16{\pm}0.14 {\mu}g/g$ cr. There was a trend that urinary 1-OHP level of residents who dwelling in apartment were higher compared with detached home, Comparison of 1-OHP level between heating by kerosene and LPG, Much higher gas heating type than kerosene type (P<0.05). This result implies that the urinary 1-OHP can be applied as the PAHs exposure indices.

The Study for Application of Commercial Modified Starch to Frozen and Retort Foods (냉동 및 레토르트식품에서 상업적 변성전분의 적용에 관한 연구)

  • 장재권
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.27 no.5
    • /
    • pp.881-889
    • /
    • 1998
  • For the application of the commercially modified starch in frozen and retort foods, apparent viscosity and water loss were measured at each stages of heating, sterilization and freezing-thawing stages. Apparent viscosity showed the exponential increase with concentration and the slopes of apparent viscosity against concentration in the Firm-Tex(hydroxypropyl distarch phosphate), Hi-Flo(acetylated distarch adipate) and Colflo 67(acetylated distarch adipate) from waxy maize starch were higher than those of Amyloacetate M20(starch acetate) and X-amylo 250(distarch phosphare) from potato starch. In the presence of 1 or 2% NaCl, X-amylo 250 among modified starches showed the increase in water loss and the decrease in apparent viscosity, whereas Colflo 67, Hi-Flo and Firm-Tex were little affected by NaCl. In the presence of 1 or 2% sucrose, water loss and apparent viscosity of the modified starches were not affected. In the range of pH 4~8, water loss and apparent viscosity of the modified starches had no change but the differences were detected to some extent between each of heating, sterilization and freezing-thawing stages. In the apparent viscosity and water loss of the modified starches after 3 week storage from heating and sterilization, Hi-Flo, Amyloacetate M20 and X-amylo 250 were not changed at the storage period, and the overall acceptability of retort food containing the modified starches such as Firm-Tex and Amyloacetate M20 were favored more than others. In the apparent viscosity and water loss of the modified starches which have been frozen and thawed three times repeatedly, Colflo 67, Hi-Flo and Firm-Tex were not changed in freezingthawing, and the overall acceptability of frozen food containing Firm-Tex was most favored.

  • PDF

Economic Evaluation of Glass Greenhouse Heating Solar Thermal System Applied with Seasonal Borehole Thermal Energy Storage System (BTES 방식의 계간축열 시스템을 적용한 유리온실의 난방용 태양열시스템의 경제성 평가)

  • Park, Sang-Mi;Seo, Tae-Beom
    • Journal of the Korean Solar Energy Society
    • /
    • v.38 no.5
    • /
    • pp.63-74
    • /
    • 2018
  • The heating performance of a solar thermal seasonal storage system applied to a 1,320 m2 glass greenhouse was analyzed numerically, and the economic feasibility depending upon the number of boreholes was evaluated. For this study, the gardening 16th and 19th zucchini greenhouse of Jeollanam-do agricultural research & extension services was selected. And the heating load of the glass greenhouse selected was 1,147 GJ. BTES(Borehole Thermal Energy Storage) was considered as a seasonal storage, which is relatively economical. The number of boreholes was selected from 25 to 150. The TRNSYS was used to predict and analyze the dynamic performance of the solar thermal system. Numerical simulation was performed by modelling the solar thermal seasonal storage system consisting of flat plate solar collector, BTES system, short-term storage tank, boiler, heat exchanger, pump and controller. As a result of the analysis, when the number of boreholes was from 25 to 50, the thermal efficiency of BTES system and the solar fraction was the highest. When the number of boreholes was from 25 to 50, it was analyzed that the payback period was from 5.2 years to 6.2 years. Therefore it was judged to be the number of boreholes of the proposed system was from 25 to 50, which is the most efficient and economical.