• Title/Summary/Keyword: Heating Degree Hours

Search Result 19, Processing Time 0.089 seconds

Development of a Method to Estimate the Seasonal Heating Load for Plastic Greenhouses (플라스틱 온실의 기간난방부하 산정 방법 개발)

  • Nam, Sang Woon;Shin, Hyun Ho
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.57 no.5
    • /
    • pp.37-42
    • /
    • 2015
  • In order to provide fundamental data for the creation of environmental design criteria for horticultural facilities, we developed a method to easily calculate the seasonal heating load applying heating degree-hour while taking into account heating load reductions due to solar radiation in the daytime, and reviewed through greenhouse heating experiments. Heating experiments and measuring meteorological environments were carried out in three greenhouses located at Buyeo, Cheonan, and Buan, and we derived reduction factors of seasonal heating load according to hours of sunshine. Daily mean hours of sunshine during the experiment period in each of the greenhouse was 4.0 to 8.3 hours, and the reduction factor of seasonal heating load was 0.64 to 0.85, has been shown to decrease linearly with the increase in hours of sunshine. A method to estimate the seasonal heating load for greenhouses was developed using the reduction factor of seasonal heating load derived from the greenhouse heating experiment, including the adjustment factor of seasonal heating load according to hours of sunshine. The developed method was validated through heating experiments in a greenhouse located at Cheonan. Greenhouse seasonal heating loads calculated by the method developed in this study were analyzed to show the estimate error of 1.2 to 5.0%. It showed that the accuracy increased 2.3 times more than when using the heating load reduction factor of 0.75 applied uniformly in previous studies. Thus, the calculation method of seasonal heating load for greenhouses considering hours of sunshine developed in this study could be utilized for energy estimation, management planning, and economic evaluation in greenhouse design.

Comparative Analysis of Accumulated Temperature for Seasonal Heating Load Calculation in Greenhouses (온실의 기간난방부하 산정을 위한 난방적산온도 비교분석)

  • Nam, Sang-Woon;Shin, Hyun-Ho;Seo, Dong-Uk
    • Journal of Bio-Environment Control
    • /
    • v.23 no.3
    • /
    • pp.192-198
    • /
    • 2014
  • To establish the design criteria for seasonal heating load calculation in greenhouses, standard weather data are required. However, they are being provided only at seven regions in Korea. So, instead of using standard weather data, in order to find the method to build design weather data for seasonal heating load calculation, heating degree-hour and heating degree-day were analyzed and compared by methods of fundamental equation, Mihara's equation and modified Mihara's equation using normal and thirty years from 1981 to 2010 hourly weather data provided by KMA and standard weather data provided by KSES. Average heating degree-hours calculated by fundamental equation using thirty years hourly weather data showed a good agreement with them using standard weather data. The 24 times of heating degree-day showed relatively big differences with heating degree-hour at the low setting temperature. Therefore, the heating degree-hour was considered more appropriate method to estimate the seasonal heating load. And to conclude, in regions which are not available standard weather data, we suggest that design weather data should be analyzed using thirty years hourly weather data. Average of heating degree-hours derived from every year hourly weather data during the whole period can be established as environmental design standards, and also minimum and maximum of them can be used as reference data for energy estimation.

Studies on the Variation of Physico-Chemical Characteristics During Storage and Frying (고추씨 기름의 저장 및 가열에 따른 이화학적 변화에 관한 연구)

  • Choi, Young-Jin;Ko, Young-Su
    • Korean journal of food and cookery science
    • /
    • v.6 no.2
    • /
    • pp.67-76
    • /
    • 1990
  • To observe the propability as the frying oil and oxidative stability of red pepper seed oil, some physico-chemical tests of the oil were examined during 21 days storage period at 5$^{\circ}C$, 15$^{\circ}C$ and 30$^{\circ}C$, and AOM value determined and after heating the oil at 180${\pm}$5$^{\circ}C$ for 40 hours with or without antioxidants. The analysis storage stability of red pepper seed oil showed that the quality of storage group at 5$^{\circ}C$ was almost as good as fresh oil, and the storage group at 30$^{\circ}C$ showed certain degree of rancidity. Change of physico-chemical characteristic during storage were so small so that storage stability of red pepper seed oil was found to be good. AOM stability of red pepper seed oil was 7 hours which is lower than other vegetable oil, but the degree of stability grew greatly after adding phenolic antioxidants, such on TBHQ or PG. As for the chemical change after heating continuously for 40 hours, acid value, peroxide value and refractive index increased, but iodine value decreased as the heating processed. The fatty acid composition also showed the remarkable reduction of linoleic acid. The addition of antioxidants resulted in the delay of oxidation, the degree of which was greater in TBHQ than in PG.

  • PDF

Analysis and Comparison of Standard and Existed Heating Degree-Hours Model for decision of Greenhouse Heating Load in Korea (온실의 난방부하 결정을 위한 Degree-Hour 모델식 비교 분석)

  • Woo, Young-Hoe
    • Journal of Practical Agriculture & Fisheries Research
    • /
    • v.6 no.1
    • /
    • pp.143-154
    • /
    • 2004
  • The value of daily heating degree hour(described as DH hereafter) is essential for calculating the heating load of a greenhouse during the winter months. Many researchers have so for proposed different models for estimating DH value. Models for estimating DH have been investigated DH(unit, ℃·h·year-1) in this paper. The comparisons of standard and existed DH values were made to know the estimation error of each model proposed so far. The standard DH values and other proposed DH values have were obtained for the inside setpoint temperatures of 9, 13, 16 and 20℃ in greenhouse, estimated based on meterological data from 1961 to 2000 according to locals, and standard DH values were independent and existed DH values were dependent. Among the various model, the one developed theoretically by Mihara modified to author was the best fitting for standard DH values. The DH values were obtained for the inside setpoint temperature of 9, 13, 16 and 20℃ by Modified Mihara's model. A new DH contour line graph was proposed using Modified Mihara's model. Using the DH contour line graph, the DH values can be obtained easily for any setpoint according to local.

Temperature History of the Slab Concrete applying Revised Bubble Sheet with Heating Cable (열선 매입과 열선 및 버블시트 조합의 개량형 버블시트를 포설한 슬래브 콘크리트의 온도이력 특성)

  • Jung, Eun-Bong;Ahn, Sang-Ku;Jung, Sang-Hyun;Ko, Kyung-Taek;Han, Min-Cheol;Han, Cheon-Goo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2013.11a
    • /
    • pp.23-25
    • /
    • 2013
  • In this study, the results are compared with the case of the concrete with embedded heating wire to verify the performance of the IB made in order to improve the workability and affordability, and to determine the effectiveness of early frost damage prevention. The IB was made using the 5W heating wire and layed on the upper surface of the concrete. The temperature was reduced to below 0℃ approximately within 24 hours, then approached the external temperature thereafter. On the other hand, when the 20W heating wire was used to make the IB and applied the same way, the temperature remained around -2 to 3℃ on the average even through the temperature was reduced to below 0℃, due to the heating wire with relatively large heating capacity. It appeared to reach 85% of the direct heating by embedding the heating wire relatively deeper in the concrete. However, it was determined that using the IB made with the 20W heating wire will prevent the early frost damage to some degree in -10℃.

  • PDF

A Study on the Comfort, Physiological Responses and Microclimate in Beding Pad (온돌에서의 욕의 쾌적성에 관한 연구)

  • Lee Soon Won;Kweon Soo Ae
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.14 no.1 s.33
    • /
    • pp.44-54
    • /
    • 1990
  • The purpose of this study was to investigate the effects of thickness of the sleeping pad on the physiological responses and the microclimate in the heating ondol room during sleeping time. The measuring points were skin temp., weight loss and body movement as physiological responses and the compression ratio, the temp. on/under the sleeping pad, the inside limp. of the sleeping quilts and subjective sence while 7 hours sleeping. Thickness of sleeping pads was 27.2 mm(A), 34.8 mm (B), 47.9 mm(C) used for 90 days and no used pad 60.7 mm(D). The floor surface temp. was keeping $29{\pm}1^{\circ}C$ while the environmental conditions was at $23{\pm}1^{\circ}C$ ($50{\pm}5\%$ R.H.) The results were as followings; 1) The mean compression ratio after using the sleeping pads for 45 days was about $70\%$ , and it wasn't increased any more thereafter 2) After 2 hours sleeping the temp. under the sleeping pads was shown that C and D were higher than A and B, and the temp. on the sleeping pads was shown that A and C pads were higher than B and D. But after 3-4 hours sleeping the skin temp. of legs was shown that B and D pads were higher than A and C. 3) Weight loss for C pad was significantly higher than others. Body movement and side position in tying was higher in A and C pads than B and D. 4) The inside temp. of quilt for A and C pads were higher in the early part of sleeping period than those of B and C pads and relative humidity was lower in C than others. 5) D pad was softer than others and fatigue degree was turned out to be lowest in D, the highest in A. From this point of view, we concluded that thickness of the sleeping Pad in the heating ondol room had different characteristic from that in no heating ondol room. And 35 mm used pad was turned out to be proper.

  • PDF

Development of Bin Weather Data for Simplified Energy Calculations (간역열부하계산용(簡易熱負荷計算用) Bin기상(氣象)데이터)

  • Kim, Doo Chun;Choi, Jin Hee
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.17 no.1
    • /
    • pp.28-43
    • /
    • 1988
  • The purpose of this research is to produce bin weather data for Seoul from Standard Weather Data. The intended use of these data is for input to recently developed models for simplified energy calculations and for generating variable-base degree-day information. The data produced under this study include $3^{\circ}C$ bin data covering the full range of dry-bulb temperatures with mean coincident wet-bulb and daytime coincident solar radiation, wet-bulb bins down to freezing temperature, wind speed bins with prevailing directions, and heating and cooling degree hours to nine different temperature bases. All of these data are tabulated in six separate time periods and total daily categories for monthly and annual periods.

  • PDF

A Study on Thermally Stratied Hot Water Storage Tank in A Solar Heating System (태양열 난방 시스템에 적용되는 축열조의 성층화에 관한 연구)

  • Hong, Hi-Ki;Kim, Hyo-Kyung
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.15 no.1
    • /
    • pp.87-96
    • /
    • 1986
  • An experiment on the devices that enchance the stratification of storage tanks in a solar heat ins system has been carried out. The benefits of thermal stratification in sensible heat storage are to increase the system performance such as the collector efficiency or the fraction of the total load supplied by solar energy. Using the diffuser and the distributor as the stratification enchancement device, the expeliments were perfomed in the different condition of diameter and material of the distributor. As a result of experiments, there exists the diameter of distributor in which the stratification is made maximum under certain design and operation condition. Also it was identified that the kind of distributor material influenced the degree of stratification. Comparing the experimental result to the computational results calculated under the same conditions, the node number N(stratification index) was determined. The results of computer simulation that was performed about the actual solar heating system in Seoul for 24 hours show the relative advantage of stratified over well-mixed storage and the significant improvements in system performance.

  • PDF

A Study on Hot Ductility Behavior of Ni-based Superalloys (니켈기 초내열합금의 고온연성거동에 관한 연구)

  • Lee, Choung-Rae;Um, Sang-Ho;Kim, Sung-Wook;Choi, Cheol;Lee, Chang-Hee
    • Journal of Welding and Joining
    • /
    • v.22 no.2
    • /
    • pp.59-68
    • /
    • 2004
  • Plasma transferred arc welding (PTAW) has been taken into consideration for repairing Ni-based superalloy components used gas turbine blades. Various cracks has been generally reported to be found in the base metal heat affected zone(HAZ) along grain boundary. Thus, hot cracking susceptibility of Ni-based superalloys was evaluated according to heat treatments. Hot ductility test was conducted on specimens with solution treated at 112$0^{\circ}C$ for 2 hours and aging treated at 845$^{\circ}C$ for 24hours after solution treatment. The results of the hot ductility test appeared that solution treated specimens were the highest ductility recovery rate among three conditions. The loss of ductility at high temperature in Ni-based superalloy was mainly controlled by the degree of pain boundary wetting due to constitutional liquation of MC carbide precipitates. Meanwhile, the highest ductility recovery rate in solution-treated alloys seems to be lack of M23C6, which can be dissolved during heating and then result in the local enrichment of Cr in the vicinity of the grain boundary.

A Study on the Formation of Trans Fatty Acids with Heating and Storage of Fats and Oils (I) - The Change of Physicochemical Characteristics and Total Trans Fatty Acids Content - (유지의 가열 및 저장에 따른 Trans 지방산 생성에 관한 연구(I) -일부 이화학적 특성 및 Trans 지방산 함량변화를 중심으로-)

  • Kim, Duck-Sook;Koo, Bon-Soon;Ahn, Myung-Soo
    • Korean journal of food and cookery science
    • /
    • v.6 no.2
    • /
    • pp.37-50
    • /
    • 1990
  • The cause and the degree of the cis to trans isomerization were investigated about soybean oil (SBO), corngerm oil (CGO), cottonseed oil (CSO), margarine (MG) and shortening (ST). All samples treated with various conditions were analyzed to determine physicochemical characteristics (AV, POV, IV, RI), fatty acid composition, total trans fatty acid content and change of trans fatty acid composition by GLC, IR and HPLC. The results were obtained as follows; 1. Physicochemical constants were changed with a gentle slope according to incubating period at 40${\pm}$2$^{\circ}C$ and physicochemical constants of margarine and shortening were changed, significiantly. 2. The saturation degree in the unsaturated fatty acid composition determined by GLC gradually were increased during incubation and heating periodically. For palmitic-and stearic acid content at the samples stored in the incubator, the saturation degrees were gradually increased. But for the case of heat treatment, they were increased more rapidly than other fatty acids. 3. Total trans fatty acid contents in each samples were determined by GLC, IR and HPLC, the amount of trans fatty acids were measured with discrepancy. It was caused by deviation of analytical instruments, methods and the kinds of samples. Trans fatty acids were measured more definitly in IR more than GLC and HPLC. On the other hand, total trans fatty acid contents in average levels for SBO, CGO, CSO, MG and ST stored for 35 days and heated for 24 hours were 1.3%, 1.1%, 0.9%, 22.6% and 13.8%, and 3.6%, 3.0%, 2.8%, 41.2% and 20.8%, respectively.

  • PDF