• Title/Summary/Keyword: Heating Condition

Search Result 1,300, Processing Time 0.03 seconds

A study on the antioxidant activity of products of caramel-type-browning reaction (Caramel 갈색화 반응 생성물의 항산화성에 관한 연구)

  • 신민자;안명수
    • Korean journal of food and cookery science
    • /
    • v.16 no.6
    • /
    • pp.629-639
    • /
    • 2000
  • The study was carried out to compare the antioxidant activities of products from caramel-type-browning reaction of xylose(XY), glucose(GL), sucrose(SU), glucose + citric acid (GLCA), glucose + sodium citrate(GLSC), glucose + glycine(GLGC) heated at 80, 120 or 140$^{\circ}C$ for 24 hr. 1. The hydrogen donating ability (HDA) of browning reaction products was generally enhanced as the browning temperature and time increased. The HDAs of the browning reaction products heated at 80$^{\circ}C$ for 24 hr were in the order of GLSC (0.387) > GLSC (0.362) > GLCA (0.301) > GL (0.299) > XY (0.290) > SU (0.281). But they were in the order of GLSC (0.543) > SU (0.328) > GL (0.309) > GLGC (0.325) > XY (0.298) > GLCA (0.275) under the condition of heating at 140$^{\circ}C$ for 24 hr. 2. The antioxidant activities of the anhydrous ethanol extracts of the browning mixtures were inferior to that of TBHQ as measured in com oil, but SU was superior to tocopherol in its antioxidant activity. All the browning mixtures showed antioxidant activities when heated at 80$^{\circ}C$; however, only SU and GLCA showed the activites at 120 or 140$^{\circ}C$. And the antioxidant activity of the SU extract was higher than that of TOCO. The antioxidant activities of the ethanol extracts were in the order of TBHQ > GLCA > GLGC > TOCO > SU > XY > GL > GLSC > control at 80$^{\circ}C$, TBHQ > SU > TOCO > GLCA > control > GLSC> XY > GL > GLGC at 120$^{\circ}C$, and TBHQ > SU > TOCO > GLCA > control > GLSC > GLGC > XY > GL at 140$^{\circ}C$.

  • PDF

Evaluation of the Temperature Drop Effect and the Rutting Resistance of Moisture Retaining-Porous Asphalt Pavement Using Accelerated Pavement Testing (포장가속시험을 이용한 보수형 배수성 포장의 온도저감 효과 및 소성변형 저항특성 연구)

  • Kwak, Byoung-Seok;Suh, Young-Chan;Song, Chul-Young;Kim, Ju-Won
    • International Journal of Highway Engineering
    • /
    • v.11 no.3
    • /
    • pp.97-109
    • /
    • 2009
  • One of the main causes of asphalt rutting is high temperature of the pavement. Nevertheless, there has been few research on lowering the pavement temperature for reducing rutting. This study investigated the performance characteristics of moisture-retaining porous asphalt pavement, which is known to have a temperature reducing effect. The purpose of this study is to quantify the temperature reducing effect of moisture-retaining porous asphalt pavement and its effect of reducing rutting through Accelerated Pavement Testing(APT). Additionally, the possibility of reducing the thickness of the pavement in comparison to general dense grade pavement by analyzing structural layer coefficient of moisture retaining pavement. A total of three test sections consisting of two moisture-retaining porous asphalt pavement sections and one general dense-grade porous asphalt pavement section were constructed for this study. Heating and spraying of water were carried out in a regular cycle. The loading condition was 8.2 ton of wheel load, the tire pressure of $7.03kgf/cm^2$, and the contact area of $610cm^2$. The result of this experiment revealed that the temperature reducing effect of the pavement was about $6.6{\sim}7.9^{\circ}C$(average of $7.4^{\circ}C$) for the middle layer and $7.9{\sim}9.8^{\circ}C$(average of $8.8^{\circ}C$) for surface course, resulting in a rutting reduction of 26% at the pavement surface. Additionally, the structural layer coefficient of moisture retaining pavement measured from a laboratory test was 0.173, about 1.2 times that of general dense grade pavement. The general dense-grade porous asphalt pavement test section exhibited rutting at all layers of surface course, middle layer, and base layer, while the test sections of moisture-retaining porous asphalt pavement manifested rutting mostly at surface course only.

  • PDF

Analysis of the Level of Microbial Contamination in the Manufacturing Company of Ginseng Products (인삼류(홍삼, 백삼) 제조·가공업체의 미생물 오염도 조사)

  • Shim, Won-Bo;Lee, Chae-Won;Choi, Young-Dong;Park, Sang-Gon;Jeong, Myeong-Jin;Kim, Jeong-Sook;Kim, Se-ri;Park, Ki-Hwan;Chung, Duck-Hwa
    • Journal of Food Hygiene and Safety
    • /
    • v.30 no.2
    • /
    • pp.159-165
    • /
    • 2015
  • The aim of this study was to investigate microbiological contamination levels in the manufacturing company of ginseng products (white and red ginseng). Firstly, the contamination level for ginseng and each stage ginseng were 1.8~4.9 log CFU/g (total bacteria), 1.2~3.0 log CFU/g (coliform), 0.8~4.1 log CFU/g (fungi). However, only Bacillus cereus among pathogenic bacteria was detected from a few sample. The contamination of total bacteria tended to decrease as ginseng was being processing. Therefore, that of finished products (white and red ginseng) showed the lowest contamination level among each stage ginseng sample. That of fungi decreased steadily, although the contamination of fungi has tended to increase right after ginseng was steamed. Secondly, the contamination level for working tools and facilities were $1.7{\sim}4.7log\;CFU/cm^2$ (total bacteria), $0.4{\sim}4.0log\;CFU/cm^2$ (coliform), $0.9{\sim}4.2log\;CFU/cm^2$ (fungi). Especially, washing and peeling machines were higher contamination level. Finally, the contamination level of worker who washed and steamed ginseng was higher than worker who shaped, sorted and stored ginseng. Also, Staphylococus aureus was detected at 0.2~0.7 log CFU/hand on some wokers' hands. These results showed proper heating condition (temperature and time) and tidy manufacturing facility are the most important to avoid developing any microbiological problem of Ginseng Products.

HACCP Application of Instant Ablactation Baby Food Processing (즉석 이유식 제조시 HACCP의 적용)

  • 이정규;노완섭
    • The Korean Journal of Food And Nutrition
    • /
    • v.14 no.5
    • /
    • pp.457-466
    • /
    • 2001
  • In this study. HACCP system was applied to improve the quality of instant ablactation baby food with rising sanitary problem among SunSig(powder of roasted grains and vegetables) . It took about 9min 30 second to produce and the temperature status of raw materials were 30.9∼31.8$\^{C}$. Raw material and production phase goods had average 6.2 in pH and 0.23∼0.63 in water activity. The average number of total aerobic bacteria(TAB) and coliform were 1.4$\times$10$^4$ CFU/g, 5.5$\times$10 CFU/g in raw materials. And the number became 8.7$\times$10$^2$ CFU/g, 6.9$\times$10 CFU/g after 1st grinding step. The distributions of TAB and coliform in equipments were 3.8$\times$10$^4$ CFU/㎠, 8.0$\times$10 CFU/㎠ on the average. According to storage temperature, variations of number of TAB coliform were slight at 4$\^{C}$ but increased at 20$\^{C}$ and 30$\^{C}$ . Therefore following subjects can be issued on the basis of results. Minimize the storage time and keep at cool temperature. 1st and 2nd grinders should be managed hygienically. Establish the heating step during the production of instant action baby food. Instant ablactation baby food produced should be stored at cool and freeze condition.

  • PDF

Strategies about Optimal Measurement Matrix of Environment Factors Inside Plastic Greenhouse (플라스틱온실 내부 환경 인자 다중센서 설치 위치 최적화 전략)

  • Lee, JungKyu;Kang, DongHyun;Oh, SangHoon;Lee, DongHoon
    • Journal of Bio-Environment Control
    • /
    • v.29 no.2
    • /
    • pp.161-170
    • /
    • 2020
  • There is systematic spatial variations in environmental properties due to sensitive reaction to external conditions at plastic greenhouse occupied 99.2% of domestic agricultural facilities. In order to construct 3 dimensional distribution of temperature, relative humidity, CO2 and illuminance, measurement matrix as 3 by 3 by 5 in direction of width, height and length, respectively, dividing indoor space of greenhouse was designed and tested at experimental site. Linear regression analysis was conducted to evaluate optimal estimation method in terms with horizontal and vertical variations. Even though sole measurement point for temperature and relative humidity could be feasible to assess indoor condition, multiple measurement matrix is inevitably required to improve spatial precision at certain time domain such as period of sunrise and sunset. In case with CO2, multiple measurement matrix could not successfully improve the spatial predictability during a whole experimental period. In case with illuminance, prediction performance was getting smaller after a time period of sunrise due to systematic interference such as indoor structure. Thus, multiple sensing methodology was proposed in direction of length at higher height than growing bed, which could compensate estimation error in spatial domain. Appropriate measurement matrix could be constructed considering the transition of stability in indoor environmental properties due to external variations. As a result, optimal measurement matrix should be carefully designed considering flexibility of construction relevant with the type of property, indoor structure, the purpose of crop and the period of growth. For an instance, partial cooling and heating system to save a consumption of energy supplement could be successfully accomplished by the deployment of multiple measurement matrix.

Antioxidant Activities and Quality Characteristics of Germinated Rough Rice Tea according to Roasting Temperature, Time and Leaching Condition (볶음 조건 및 침출 조건에 따른 발아 벼차의 항산화 활성 및 품질 특성)

  • Lee, Sang-Hoon;Lee, Youn-Ri;Hwang, In-Guk;Woo, Koan-Sik;Kim, Kyoung-Ho;Kim, Kee-Jong;Jeong, Heon-Sang
    • Korean Journal of Food Science and Technology
    • /
    • v.41 no.4
    • /
    • pp.386-391
    • /
    • 2009
  • To verify the possibility of manufacturing a germinated rough rice tea, germinated rough rice was roasted at 200, 220, and $250^{\circ}C$ for 10, 20, and 30 min. The treated rice powder was then put into tea bags and leached for 1, 3, and 5 min, after which their antioxidant, physicochemical, and sensory characteristics were compared. The total polyphenol content and 2,2'-Azino-bis-(3-ethyl benzothiazoline-6-sulfonic acid) (ABTS) radical scavenging activities of the germinated rough rice tea increased as the roasting temperature increased as well as in response to increased roasting and leaching times. Furthermore, the greater the roasting temperature, roasting time, and leaching time, the greater the increase in total soluble solid contents. Moreover, the turbidity and browning index of the germinated rice tea rose as the roasting temperature, roasting time, and leaching time increased. Additionally, the pH tended to decrease as the roasting temperature, roasting time, and leaching time increased. Evaluation of the sensory characteristics of the germinated rice tea revealed that the formation of a Maillard reaction product in the course of heating the rice added a unique flavor, which led to increase preference for the color, flavor, and taste, and therefore, the overall preference.

Application of Greenhouse Climate Management Model for Educational Simulation Design (교육용 시뮬레이션 설계를 위한 온실 환경 제어 모델의 활용)

  • Yoon, Seungri;Kim, Dongpil;Hwang, Inha;Kim, Jin Hyun;Shin, Minju;Bang, Ji Wong;Jeong, Ho Jeong
    • Journal of Bio-Environment Control
    • /
    • v.31 no.4
    • /
    • pp.485-496
    • /
    • 2022
  • Modern agriculture is being transformed into smart agriculture to maximize production efficiency along with changes in the 4th industrial revolution. However, rural areas in Korea are facing challenges of aging, low fertility, and population outflow, making it difficult to transition to smart agriculture. Among ICT technologies, simulation allows users to observe or experience the results of their choices through imitation or reproduction of reality. The combination of the three-dimension (3D) model and the greenhouse simulator enable a 3D experience by virtual greenhouse for fruits and vegetable cultivation. At the same time, it is possible to visualize the greenhouse under various cultivation or climate conditions. The objective of this study is to apply the greenhouse climate management model for simulation development that can visually see the state of the greenhouse environment under various micrometeorological properties. The numerical solution with the mathematical model provided a dynamic change in the greenhouse environment for a particular greenhouse design. Light intensity, crop transpiration, heating load, ventilation rate, the optimal amount of CO2 enrichment, and daily light integral were calculated with the simulation. The results of this study are being built so that users can be linked through a web page, and software will be designed to reflect the characteristics of cladding materials and greenhouses, cultivation types, and the condition of environmental control facilities for customized environmental control. In addition, environmental information obtained from external meteorological data, as well as recommended standards and set points for each growth stage based on experiments and research, will be provided as optimal environmental factors. This simulation can help growers, students, and researchers to understand the ICT technologies and the changes in the greenhouse microclimate according to the growing conditions.

Comparing Net CO2 Uptake of Schlumbergera truncata 'Pink Dew' Phylloclades in a Growth Chamber and a Greenhouse (생육상과 온실에서 게발선인장 '핑크듀'의 엽상경별 CO2 흡수율 비교)

  • Seo Hee Jung;Ah Ram Cho;Yoon Jin Kim
    • Journal of Bio-Environment Control
    • /
    • v.32 no.1
    • /
    • pp.64-71
    • /
    • 2023
  • Crassulacean acid metabolism (CAM) plants use surplus CO2 generated by cooling and heating at night when ventilation is not needed in a greenhouse. Schlumbergera truncata 'Pink Dew' is a multi-flowering cactus that needs more phylloclades for high-quality production. This study examined photosynthetic characteristics by the phylloclade levels of S. truncata in a growth chamber and a greenhouse for use of night CO2 enrichment. The CO2 uptake rate of the S. truncata's top phylloclade in a growth chamber exhibited a C3 pattern, and the second phylloclade exhibited a C3-CAM pattern. The CO2 uptake rate of the top phylloclade in a greenhouse showed a negative value both day and night, but those of the second phylloclade exhibited a CAM pattern. The stomatal conductance and water-use efficiency (WUE) of S. truncata at both the top and second phylloclades were higher in a growth chamber than in a greenhouse. The WUE of S. truncata in a growth chamber and a greenhouse was higher at the second phylloclade, which is a CAM pattern compared with those of the top phylloclade. The daily total net CO2 uptake of S. truncata was higher in a growth chamber than in a greenhouse. The daily total net CO2 uptake of S. truncata at the second phylloclade had the highest value of 155 mmol·m-2·d-1 in a growth chamber. The night total CO2 uptake of S. truncate at the second phylloclade was 3-fold higher in a growth chamber than in a greenhouse. S. truncata's second phylloclade exhibited a CAM pattern that uptake CO2 at night, and the second phylloclade, was more mature than the top phylloclade. A multi-flowering cactus S. truncata 'Pink Dew' efficiently uptake night surplus CO2 in the proper environmental condition with matured phylloclade.

Empirical Study of Biogas Purification Equipment (바이오가스 정제 설비의 실증 연구)

  • Hwan Cheol Lee;Jae-Heon Lee
    • Plant Journal
    • /
    • v.18 no.4
    • /
    • pp.58-65
    • /
    • 2023
  • In this study, to increase the methane content of biogas supplied from Nanji Water Regeneration Center and to purify impurities, a three-stage membrane purification process was designed and installed to demonstrate operation. The methane concentration of biomethane produced in the 2 Nm3/h purification process was set to three cases: 95%, 96.5%, and 98%, and the membrane area ratio of the membrane was 1:1, 1:2, 1:1:1, The optimum conditions for the membrane area of the separator were derived by changing to five of 1:2:1 and 1:2:2. 3 stage separation membrane process of 30 Nm3/h was installed to reflect the optimum condition of 2 Nm3/h, and biomethane production of 98% or more of methane concentration was demonstrated. As a result of the operation of the 2 Nm3/h refining device, the methane recovery rate at the 98% methane concentration was 95.6% when the membrane area ratio was 1:1 as the result of the two-stage operation of the separator, and the recovery rate of methane at 1:2 was increased to 96.8%. The methane recovery rate of the membrane three-stage operation was highest at 96.8% when the membrane area ratio was operated at 1:2:1. The carbon dioxide removal rate was 16.4 to 96.4% and the 2:2 to 95.7% film area ratio in the two-step process. In the three-step process, the film area ratio was 1:2:1 to 95.4%, and the two-step process showed higher results than the three-step process. In the 30 Nm3/h scale biogas purification demonstration operation, the methane concentration after purification was 98%, the recovery rate of methane was 97.1%, the removal rate of carbon dioxide was 95.7%, and hydrogen sulfide, the cause of corrosion, was not detected, and the membrane area ratio was 1:2:1 demonstration operation, biomethane production with a methane concentration of 98% or higher was possible.

  • PDF

The Influence of Ventilation and Shade on the Mean Radiant Temperature of Summer Outdoor (통풍과 차양이 하절기 옥외공간의 평균복사온도에 미치는 영향)

  • Lee, Chun-Seok;Ryu, Nam-Hyung
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.40 no.5
    • /
    • pp.100-108
    • /
    • 2012
  • The purpose of the study was to evaluate the influence of shading and ventilation on Mean Radiant Temperature(MRT) of the outdoor space at a summer outdoor. The Wind Speed(WS), Air Temperature(AT) and Globe Temperature(GT) were recorded every minute from $1^{st}$ of May to the $30^{th}$ of September 2011 at a height of 1.2m above in four experimental plots with different shading and ventilating conditions, with a measuring system consisting of a vane type anemometer(Barini Design's BDTH), Resistance Temperature Detector(RTD, Pt-100), standard black globe(${\O}$ 150mm) and data acquisition systems(National Instrument's Labview and Compfile Techs' Moacon). To implement four different ventilating and shading conditions, three hexahedral steel frames, and one natural plot were established in the open grass field. Two of the steel frames had a dimension of $3m(W){\times}3m(L){\times}1.5m(H)$ and every vertical side covered with transparent polyethylene film to prevent lateral ventilation(Ventilation Blocking Plot: VP), and an additional shading curtain was applied on the top side of a frame(Shading and Ventilation Blocking Plot: SVP). The third was $1.5m(W){\times}1.5m(L){\times}1.5m(H)$, only the top side of which was covered by the shading curtain without the lateral film(Shading Plot: SP). The last plot was natural condition without any kind of shading and wind blocking material(Natural Open Plot: NP). Based on the 13,262 records of 44 sunny days, the time serial difference of AT and GT for 24 hour were analyzed and compared, and statistical analysis was done based on the 7,172 records of daytime period from 7 A.M. to 8 P.M., while the relation between the MRT and solar radiation and wind speed was analyzed based on the records of the hottest period from 11 A.M. to 4 P.M.. The major findings were as follows: 1. The peak AT was $40.8^{\circ}C$ at VP and $35.6^{\circ}C$ at SP showing the difference about $5^{\circ}C$, but the difference of average AT was very small within${\pm}1^{\circ}C$. 2. The difference of the peak GT was $12^{\circ}C$ showing $52.5^{\circ}C$ at VP and $40.6^{\circ}C$ at SP, while the gap of average GT between the two plots was $6^{\circ}C$. Comparing all four plots including NP and SVP, it can be said that the shading decrease $6^{\circ}C$ GT while the wind blocking increase $3^{\circ}C$ GT. 3. According to the calculated MRT, the shading has a cooling effect in reducing a maximum of $13^{\circ}C$ and average $9^{\circ}C$ MRT, while the wind blocking has heating effect of increasing average $3^{\circ}C$ MRT. In other words, the MRT of the shaded area with natural ventilation could be cooler than the wind blocking the sunny site to about $16^{\circ}C$ MRT maximum. 4. The regression and correlation tests showed that the shading is more important than the ventilation in reducing the MRT, while both of them do an important role in improving the outdoor thermal comfort. In summary, the results of this study showed that the shade is the first and the ventilation is the second important factor in terms of improving outdoor thermal comfort in summer daylight hours. Therefore, it can be apparently said that the more shade by the forest, shading trees etc., the more effective in conditioning the microclimate of an outdoor space reducing the useless or even harmful heat energy for human activities. Furthermore, the delicately designed wind corridor or outdoor ventilation system can improve even the thermal environment of urban area.