• Title/Summary/Keyword: Heater

Search Result 1,742, Processing Time 0.03 seconds

Analysis on Cascade Cycle Heat Pump Application as Night Storage Heater (심야전력을 이용한 Cascade Heat Pump Cycle의 운전결과 분석)

  • JUNG, H.;HWANG, S.W.;LEE, C.H.
    • Journal of the Korean Society of Mechanical Technology
    • /
    • v.13 no.1
    • /
    • pp.113-118
    • /
    • 2011
  • To analyze and verify the effect of replacing thermal storage heater by a cascade cycle heat pump using midnight electricity was installed and tested at a customer's house in Wonju, Korea. The electric night storage heater is consist of 30kW electric heater and 2,700 liters of thermal storage water tank to supply hot water for warming house floor. The power for electric heater was cut off and hot water was only generated by cascade cycle heat pump. Current thermal storage water tank was not eliminated and electric heater wiring was modified. Some operation logic of the heat pump was also modified for proper operation. The required capacity of the heat pump and hot water temperature for given warming condition were estimated. The estimated capacity of heat pump was about 19kW and estimated hot water temperature for proper heating was at least $75^{\circ}C$.

Development of Energy Saving Electric Fan Heater (에너지 절약형 전기 온풍기 개발)

  • Kim, Jin-Bong;Koo, Dae-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 1994.07a
    • /
    • pp.97-99
    • /
    • 1994
  • Energy saving electric fan heater that uses driving part as heating part is different from general fan heater. As it uses energy that drives rotor and generate heat at the same coil. it is simpler and cheaper than fan heater. In this study, shaded-pole motor that is low cost and simple in spite of low efficiency was used for th fan heater.

  • PDF

Temperature Maintenance of an ITO Nanoparticle Film Heater (ITO 나노입자 면상발열체의 온도유지에 대한 연구)

  • Yang, Kyungwhan;Cho, Kyoungah;Im, Kiju;Kim, Sangsig
    • Journal of IKEEE
    • /
    • v.20 no.2
    • /
    • pp.171-173
    • /
    • 2016
  • In this study, we fabricate a high efficiency heater consisting of the indium tin oxide (ITO) nanoparticle (NP)-paste and polydimethylsiloxane (PDMS) and investigate the effect of PDMS on temperature maintenance of the heater through the comparison with the PDMS-free ITO film heater. Compared to the ITO film heater, the temperature of the PDMS/ITO film heater lasts 1.5 times longer. And the power consumption of the PDMS/ITO film heater is reduced by 35%, owing to the low thermal conductivity of the PDMS layer.

Implementation of Composited Fuel Heater and Test Chamber for Diesel Cars (디젤 차량용 통합 연료히터와 시험챔버 구현)

  • Yoon, Dal-Hwan
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.5
    • /
    • pp.2375-2380
    • /
    • 2013
  • In this paper, we have implemented the unified fuel heater and performance evaluation system for diesel cars. In order to strengthen an engine starting of diesel car, we need to assembly the fuel filter and heater. Especially, this assembly fuel heater is very important in winter, it is necessary for heating to operate the diesel engine. The heater for unifying the sensor and heater body can advance the performance of car and reduce the production cost. Finally, the performance test chamber is needed to evaluate the performance of heater.

A Study on The Optimal Design of SiC Ceramic Heater (SiC계 세라믹 발열체의 최적 설계에 관한 연구)

  • Cho, Hyun-Seob
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.7
    • /
    • pp.1631-1634
    • /
    • 2009
  • Compositional design and optimization of processing parameters are key factors for controlling and improving the properties of SiC-based electroconductive ceramic composites. Temperature rising time of sheath heater is 1.1 times faster than SiC ceramic heater. Heating insulation of SiC ceramic heater is 2.7 times larger than sheath heater. If SiC ceramic heater is one body type of a product application, contact resistance will decrease. I think that temperature initial rising time is faster than now. The more SiC ceramic heater is used for a long time, the more economic benefit is larger in the view point of heat insulation.

Mechanism Improvement of the Heat Exchanger for the Thermal Efficiency Increase of Hot Air Heater (온풍난방기의 열효율 증대를 위한 열교환기 구조개선)

  • Kang, Geum-Choon;Kang, Yoen-Ku;Ryou, Young-Sun;Kim, Young-Joong;Lee, Si-Young;Paek, Yee
    • Journal of Biosystems Engineering
    • /
    • v.34 no.5
    • /
    • pp.363-370
    • /
    • 2009
  • Hot air heater with light oil combustion is used as the most common heater for greenhouse heating in the winter season. Hot air heaters of 256,246 units have been supplied as main greenhouse heating equipment until 2008 and greenhouse heating cost has reached to 620 billions won in Korea. In order to improve the thermal efficiency of the hot air heater and to reduce the expenses for greenhouse heating, prototype hot air heater was manufactured and tested in this experiment. The heat exchanger of tested prototype hot air heater was circular and hexagonal pipe type and inline and stagger arrangement type. Capacity of the heating was 43,062 kJ/h and total heat transfer area of the heat exchanger was $10.728\;m^2$. According to the performance test, it could supply heat of 38,240 to 35,100 kJ/h depending on the fan motor speed of 1,740~1,220 rpm, respectively. Thermal efficiency of hot air heater was 87.0% to 80.8% in the same conditions. As a result, thermal efficiency of hot air heater with hexagonal pipe-stagger arrangement heat exchanger developed in this study was higher 10.2% than that of conventional hot air heater and heating energy saving rate of 14.3% increased.

A Study on the Characteristics of Heating Performance of High-Performance Heat Pump with VI cycle using Re-Heater (재열기를 사용한 고성능 VI 사이클 열펌프의 난방 성능 특성에 관한 연구)

  • Lee, Jin-Kook;Choi, Kwang-Hwan
    • Journal of Power System Engineering
    • /
    • v.19 no.4
    • /
    • pp.69-75
    • /
    • 2015
  • In this study, the characteristics of heating performance of a high-performance air-cooled heat pump with vapor-injection(VI) cycle using re-heater was investigated experimentally. Devices used in the experiment is consist of a VI compressor, condenser, oil separator, refrigerant (economizer outlet refrigerant) re-heater, economizer, evaporator. And R410A was used as a working fluid. The experiment was conducted with two cycles(cycles A and B) for investigating heating performance. In case of cycle B, heat exchange was conducted by re-heater between outlet refrigerant of compressor and suction refrigerant of the VI system(Fig.1, re-heater). But the re-heater was not used in case of cycle A. As a result of this experiment, discharge temperature of refrigerator in compressor was shown higher value, when the cycle B was conducted, because of the heat exchange between suction refrigerant of VI cycle and outlet refrigerant of compressor in the re-heater than cycle A that was not use re-heater. it means that liquid hammer and the decrement of heating performance can be decreased by using re-heater. Also, Heating coefficient of performance(COPh) was shown about 2.98 in Cycle B which was 4% higher than Cycle A and from these results, It was confirmed that the improvement of the heating performance of heat pump with VI cycle can be achieved by applying re-heater.

Design and Fabrication of Heater-triggered Switching System for the Charging of Bi-2223 Pancake Load (Bi-2223 팬케익부하 충전용 히터-트리거 스위칭 장치의 설계 및 제작)

  • 김영식;윤용수;배덕권;안민철;임대준;김호민;고태국
    • Progress in Superconductivity and Cryogenics
    • /
    • v.6 no.1
    • /
    • pp.43-48
    • /
    • 2004
  • This paper deals with design and fabrication of heater-triggered switching system for the high-Tc superconducting (HTS) power supply with series-connected double-pancake load. Amongst all components, heater triggering is the most important element for the performance of HTS power supply. To fabricate the optimal heater-triggered system, its characteristics have been analysed through the simulation and expriment. The thermal analysis of switching parts of the Bi-2223 solenoid according to the heater input was carried out. Based upon the analysis, 8A electromagnet current and 1.5A DC Heater current were optimally derived, and 8s and 20s for the pumping period were selected in this experiment. In the experiment. the maximum pumping current reached about 24A with Bi-2223 pancake load of 6mH.

Temperature Distributions inside a Space Heater for Greenhouse (I) - Temperature Characteristics with Heating Oil - (시설원예용 온풍난방기내의 온도분포에 관한 연구 (I) - 난방유 사용시 온도특성 -)

  • 서정덕;김종진;최규성;신창식;노수영
    • Journal of Biosystems Engineering
    • /
    • v.24 no.4
    • /
    • pp.335-342
    • /
    • 1999
  • Air and flue gas temperature distributions in the space heater for greenhouse were measured to develop a thermal design technology for the space heater. Also, the characteristics of the fan supplying air to the space heater were investigated. The temperature of the flue gas inside the flue gas tube was linearly decreased as the lenght of than those of the flue gas with the oxygen concentration of 8.25% at the last exit of the second flue gas tube. Thus, the operating efficiency of the space heater could be increased with low air ratio decreased exhausting gas temperature and saved the energy consumption with decreased excess air flow. The temperature of the air supplied by fan was increased slowly around the first flue gas tube, meanwhile, increased sharply around the second flue gas tube due to large LMTD (Logarithmic Mean Temperature Difference) at the first flue gas tube than which of the second flue gas tube.

  • PDF

An Experimental Study on the Fire Hazards in Electric Heater (전기히터의 화재위험성에 관한 실험연구)

  • Hong, Sung-Ho;Lee, Bock-Young;Park, Sang-Tae;Yu, Hyun-Jong
    • Journal of the Korean Society of Safety
    • /
    • v.22 no.2 s.80
    • /
    • pp.36-40
    • /
    • 2007
  • This study presents on the analysis fire hazards of electric heater. In order to analyze fire hazards fire experiment is conducted. The fire experiment is conducted to simulate normal condition and abnormal condition. The abnormal condition experiment is simulated in which combustibles are placed near by electric heater. Vertical burning test(UL 94) is conducted for the fire retardant experiment. The results show that fire hazard is high in case of abnormal condition. And Material of electric heater has not fire retardant performance. In this paper, we suggest to add temperature fuse in electric heater for reducing fire hazard.