Temperature Distributions inside a Space Heater for Greenhouse (I) - Temperature Characteristics with Heating Oil -

시설원예용 온풍난방기내의 온도분포에 관한 연구 (I) - 난방유 사용시 온도특성 -

  • 서정덕 (충북대학교 정회원) ;
  • 김종진 (한국에너지기술연구소 에너지효율연구부 보일러·연소로연구팀 정회원) ;
  • 최규성 (한국에너지기술연구소 에너지효율연구부 보일러·연소로연구팀 비회원) ;
  • 신창식 ((합) 신흥기업사 신흥기술연구소 정회원) ;
  • 노수영 (충북대학교 정회원)
  • Published : 1999.08.01

Abstract

Air and flue gas temperature distributions in the space heater for greenhouse were measured to develop a thermal design technology for the space heater. Also, the characteristics of the fan supplying air to the space heater were investigated. The temperature of the flue gas inside the flue gas tube was linearly decreased as the lenght of than those of the flue gas with the oxygen concentration of 8.25% at the last exit of the second flue gas tube. Thus, the operating efficiency of the space heater could be increased with low air ratio decreased exhausting gas temperature and saved the energy consumption with decreased excess air flow. The temperature of the air supplied by fan was increased slowly around the first flue gas tube, meanwhile, increased sharply around the second flue gas tube due to large LMTD (Logarithmic Mean Temperature Difference) at the first flue gas tube than which of the second flue gas tube.

Keywords