• Title/Summary/Keyword: Heat-wave

Search Result 738, Processing Time 0.025 seconds

Mean Heat Flux at the Port of Yeosu (여수항의 평균 열플럭스)

  • Choi Yong-Kyu;Yang Jun-Hyuk
    • Journal of Environmental Science International
    • /
    • v.15 no.7
    • /
    • pp.653-657
    • /
    • 2006
  • Based on the monthly weather report of Korea Meteorological Administration (KMA) and daily sea surface temperature (SST) data from National Fisheries Research and Development Institute (NFRDI) (1995-2004), mean heat fluxes were estimated at the port of Yeosu. Net heat flux was transported from the air to the sea surface during February to September, and it amounts to $205 Wm^{-2}$ in daily average value in May. During October to January, the transfer of net heat flux was conversed from the sea surface to the air with $-70 Wm^{-2}$ in minimum of daily average value in December. Short wave radiation was ranged from $167 Wm^{-2}$ in December to $300 Wm^{-2}$ in April. Long wave radiation (Sensible heat) was ranged from $27 (-14) Wm^{-2}$ in July to $90 (79) Wm^{-2}$ in December. Latent heat showed $42 Wm^{-2}$ with its minimum in July and $104 Wm^{-2}$ with its maximum in October in daily average value.

Development and Goals of smart EM wave absorber with heat radiating function

  • Choi, Dong Soo;Kim, Dong Il;Kim, Do Yeol;Choi, Dong Han
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2012.10a
    • /
    • pp.125-127
    • /
    • 2012
  • With the progress of electronics and radio communication technology, human enjoys greater freedom in communication. However, EMW (Electro-Magnetic wave) environments have became complicate and more difficult to control. Thus, international organizations, such as the American National Standard Institution (ANSI), Federal Communications Commission (FCC), the Comite Internationale Special des Perturbations Radio electrique (CISPR), etc, have provided standard for controlling the EM wave environments and for the countermeasure of the electromagnetic compatibility (EMC). In this paper, the status of EMW absorber and the goal of smart EMW absorber ifor the future were described. Furthermore, design method of the smart EM wave Absorber with heat radiating function was suggested. The designed smart EM wave Absorber has the absoption ability of more than 5 dB from 2 GHz to 2.45 GHz band, one optimum aperture (hole) size of which was 6 mm, 9 mm in adjacent hole space, and 6.5 mm in thickness, respectivly. Thus, it is repected that these results can be applied to various EMC devices in electronic, communication, and controlling systems.

  • PDF

Study on Exhaust Air Heat Transfer Characteristics of Heat Exchange System for White Smoke Reduction (백연 저감을 위한 열교환 시스템의 배기 열전달 특성에 관한 연구)

  • Wang, Zhen-Huan;Chun, Chong-Keun;Kwon, Young-Chul
    • Journal of the Korean Society of Mechanical Technology
    • /
    • v.20 no.6
    • /
    • pp.739-744
    • /
    • 2018
  • In this study, effects of reducing white smoke at a heat exchange system for white smoke reduction were studied in the winter season. For this purpose, the heat transfer processes on the exhaust air were investigated by Solidworks. Five wave heat exchangers of air-to-air and air-to-water type were applied for the exhaust air heat recovery. The analytical condition of the exhaust air was fixed and the computational analysis was performed according to the change of SA(supply air) inlet velocities. In order to evaluate the performance of the heat exchange system for white smoke reduction, W(water)/SA recovered capacities and the temperature/absolute humidity reduction rate were calculated. As SA inlet velocity increased, the exit temperature and absolute humidity of the mixing zone were reduced by up to about $40^{\circ}C$ and 0.12kg/kg respectively. Also, W/SA recovered capacities increased linearly up to about 35%.

Health Risk Estimation for Daily Maximum Temperature in the Summer Season using Healthcare Big Data (보건의료빅데이터를 이용한 여름철 일최고기온에 대한 건강위험도 평가)

  • Hwang, Mi-Kyoung;Kim, Yoo-Keun;Oh, Inbo
    • Journal of Environmental Science International
    • /
    • v.28 no.7
    • /
    • pp.617-627
    • /
    • 2019
  • This study investigated the relationship between heat-related illnesses obtained from healthcare big data and daily maximum temperature observed in seven metropolitan cities in summer during 2013~2015. We found a statistically significant positive correlation (r = 0.4~0.6) between daily maximum temperature and number of the heat-related patients from Pearson's correlation analyses. A time lag effect was not observed. Relative Risk (RR) analysis using the Generalized Additive Model (GAM) showed that the RR of heat-related illness increased with increasing threshold temperature (maximum RR = 1.21). A comparison of the RRs of the seven cities, showed that the values were significantly different by geographical location of the city and had different variations for different threshold temperatures. The RRs for elderly people were clearly higher than those for the all-age group. Especially, a maximum value of 1.83 was calculated at the threshold temperature of $35^{\circ}C$ in Seoul. In addition, relatively higher RRs were found for inland cities (Seoul, Gwangju, Daegu, and Daejeon), which had a high frequency of heat waves. These results demonstrate the significant risk of heat-related illness associated with increasing daily maximum temperature and the difference in adaptation ability to heat wave for each city, which could help improve the heat wave advisory and warning system.

The development of ultrasonic transmitter to enhance the efficiency of heat transfer rate in boiler (보일러내 열 전달 효율 개선을 위한 초음파발신기 개발)

  • Heo, Pil-Woo;Lee, Yang-Lae;Lim, Eui-Su;Koh, Kwang-Sik
    • Journal of Sensor Science and Technology
    • /
    • v.12 no.2
    • /
    • pp.95-101
    • /
    • 2003
  • Ultrasonic transmitter used for scale prevention in boiler or heat exchanger is composed of the magnetostrictive material which transforms electric energy into ultrasonic wave and the horn which amplifies generated ultrasonic wave and transfers it into medium loaded. In this paper, we have performed the shape design for magnetostrictive material and analyzed a few type of horns which amplify generated ultrasonic wave and found each solution theoretically. Final length of the horn has been determined by measuring the sound pressure in medium between theoretical value and experience data. At last we have given the results of our study for the effects of ultrasonic wave irradiated by manufactured ultrasonic transmitter on preventing scale deposition on test pipe under the similar condition to boiler.

Classification of Heat Wave Events in Seoul Using Self-Organizing Map (자기조직화지도를 이용한 서울 폭염사례 분류 연구)

  • Back, Seung-Yoon;Kim, Sang-Wook;Jung, Myung-Il;Roh, Joon-Woo;Son, Seok-Woo
    • Journal of Climate Change Research
    • /
    • v.9 no.3
    • /
    • pp.209-221
    • /
    • 2018
  • The characteristics of heat wave events in Seoul are analyzed using weather station data from Korea Meteorological Administration (KMA) and European Centre for Medium-Range Weather Forecast (ECMWF) ERA-Interim reanalysis data from 1979 to 2016. Heat waves are defined as events in the upper 10th percentile of the daily maximum temperatures. The associated synoptic weather patterns are then classified into six clusters through Self-Organizing Map (SOM) analysis for sea-level pressure anomalies in East Asia. Cluster 1 shows an anti-cyclonic circulation and weak troughs in southeast and west of Korea, respectively. This synoptic pattern leads to southeasterly winds that advect warm and moist air to the Korean Peninsula. Both clusters 2 and 3 are associated with southerly winds formed by an anti-cyclonic circulation over the east of Korea and cyclonic circulation over the west of Korea. Cluster 4 shows a stagnant weather pattern with weak winds and strong insolation. Clusters 5 and 6 are associated with F?hn wind resulting from an anti-cyclonic circulation in the north of the Korean Peninsula. In terms of long-term variations, event frequencies of clusters 4 and 5 show increasing and decreasing trends, respectively. However, other clusters do not show any long-term trends, indicating that the mechanisms that drive heat wave events in Seoul have remained constant over the last four decades.

Propagation of plane wave in transversely isotropic magneto-thermoelastic material with multi-dual-phase lag and two temperature

  • Lata, Parveen;Kaur, Iqbal;Singh, Kulvinder
    • Coupled systems mechanics
    • /
    • v.9 no.5
    • /
    • pp.411-432
    • /
    • 2020
  • This research is devoted to the study of plane wave propagation in homogeneous transversely isotropic (HTI) magneto-thermoelastic rotating medium with combined effect of Hall current and two temperature due to multi-dual-phase lag heat transfer. It is analysed that, for 2-D assumed model, three types of coupled longitudinal waves (quasi-longitudinal, quasi-transverse and quasi-thermal) are present. The wave characteristics like phase velocity, specific loss, attenuation coefficients, energy ratios, penetration depths and amplitude ratios of transmitted and reflected waves are computed numerically and illustrated graphically and compared for different theories of thermoelasticity. Some particular cases are also derived from this research.

Laser Lock-in Thermal Wave Imaging for Nondestructive Evaluation

  • An, Yun-Kyu;Sohn, Hoon;Kim, Ji Min
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.33 no.4
    • /
    • pp.317-322
    • /
    • 2013
  • This paper presents a new laser lock-in thermography (LLT) technique for nondestructive evaluation. LLT utilizes a modulated continuous wave laser beam as a heat source to obtain high fidelity thermal wave images even at the presence of background heat disturbances. The thermal waves propagating along the surface and through-the-thickness directions of a structure are visualized using newly developed laser lock-in amplitude and phase images, enhancing the detectability of surface and subsurface defects. The LLT technique is numerically investigated and experimentally validated using thermal images obtained from a steel specimen with low emissivity.

Stoneley wave propagation in nonlocal isotropic magneto-thermoelastic solid with multi-dual-phase lag heat transfer

  • Lata, Parveen;Singh, Sukhveer
    • Steel and Composite Structures
    • /
    • v.38 no.2
    • /
    • pp.141-150
    • /
    • 2021
  • In the present paper we have investigated the Stoneley wave propagation at the interface of two dissimilar homogeneous nonlocal magneto-thermoelastic media under the effect of hall current applied to multi-dual-phase lag heat transfer. The secular equations of Stoneley waves have been derived by using appropriate boundary conditions. The wave characteristics such as attenuation coefficients, temperature distribution and phase velocity are computed and have been depicted graphically. Effect of nonlocal parameter and hall effect are studied on the attenuation coefficient, phase velocity, temperature distribution change, stress component and displacement component. Also, some particular cases have been discussed from the present study.

An Experimental Study of Surface Materials for Planting of Building Surface by the Radiant Heat Balance Analysis in the Summer (하절기 실험을 통한 건물녹화용 피복재료의 복사수지 해석)

  • Choi, Dong-Ho;Lee, Bu-Yong
    • Journal of the Korean Solar Energy Society
    • /
    • v.30 no.3
    • /
    • pp.71-80
    • /
    • 2010
  • This study carried out to understand the thermal characteristics of various surface material which compose the city through the observation in the summer. To examine passive cooling effect of planting of building, it is arranged four different materials that is natural grass, grass block, concrete slab and artificial grass. The results of this study are as follows; (1) Natural grass and grass block show the lower surface temperature because of the structures of leaf can do more thermal dissipation effectively. (2) There is little surface temperature between artificial grass and concrete. But there is little high surface temperature difference between natural grass and concrete because of latent heat effect. (3) The concrete can play a role of the tropical nights phenomenon as high heat capacity of concrete compare with other materials. (4) It is nearly same color in artificial grass and natural grass but there is large difference between natural grass and artificial grass at albedo. There is different albedo in near infrared ray range. (5) A short wave radiation gives more effect at the globe temperature than long wave radiation. (6) The artificial turf protected the slab surface temperature increase in spite of thin and low albedo materials.