• Title/Summary/Keyword: Heat-wave

Search Result 746, Processing Time 0.03 seconds

An Analysis on the Spatial Patterns of Heat Wave Vulnerable Areas and Adaptive Capacity Vulnerable Areas in Seoul (서울시 폭염 취약지역의 공간적 패턴 및 적응능력 취약지역 분석)

  • Choi, Ye Seul;Kim, Jae Won;Lim, Up
    • Journal of Korea Planning Association
    • /
    • v.53 no.7
    • /
    • pp.87-107
    • /
    • 2018
  • With more than 10 million inhabitants, in particular, Seoul, the capital of Korea, has already experienced a number of severe heat wave. To alleviate the potential impacts of heat wave and the vulnerability to heat wave, policy-makers have generally considered the option of heat wave strategies containing adaptation elements. From the perspective of sustainable planning for adaptation to heat wave, the objective of this study is to identify the elements of vulnerability and assess heat wave-vulnerability at the dong level. This study also performs an exploratory investigation of the spatial pattern of vulnerable areas in Seoul to heat wave by applying exploratory spatial data analysis. Then this study attempts to select areas with the relatively highest and lowest level of adaptive capacity to heat wave based on an framework of climate change vulnerability assessment. In our analysis, the adaptive capacity is the relatively highest for Seongsan-2-dong in Mapo and the relatively lowest for Changsin-3-dong in Jongno. This study sheds additional light on the spatial patterns of heat wave-vulnerability and the relationship between adaptive capacity and heat wave.

Summertime Heat Waves and Ozone : an Interaction on Cardiopulmonary Mortality? - Based on the 1994 Heat Wave in Korea - (1994년 하절기의 심혈관계 및 호흡기계 초과사망 - 이상고온 및 대기오염의 영향을 중심으로 -)

  • Sung, Joo-Hon;Kim, Ho;Cho, Soo-Hun
    • Journal of Preventive Medicine and Public Health
    • /
    • v.34 no.4
    • /
    • pp.316-322
    • /
    • 2001
  • Objectives : To explore the possible effect of an interaction between summertime heat waves and ozone on cardiopulmonary mortality during the 1994 heat wave in Korea. Methods : The unusually hot summer of 1994 in Korea was defined as the heat wave in this study. We examined the associations of air pollutants with daily cardiopulmonary deaths between 1991-1995, considering the product term of the heat wave and each pollutant, weather and time trends. Results : During the heat wave, while temperatures were uniformly higher than those of other summers, the within-heat-wave difference in mortality paralleled that in the regional ozone levels. In terms of the influence of the heat wave, the results of ozone were different to those of total suspended particles (TSP) and sulfur dioxide $(SO_2)$. The ozone association (relative risk (RR) : 1.036; 95% confidence interval (CI) = 1.018-1.054) was observed only under heat wave conditions, while the TSP (RR : 1.006, 95% CI = 0.999-1.012) and the $SO_2$ (RR = 1.018, 95% CI : 1.011-1.024) associations were found under normal weather conditions (per interquartile increase of each pollutant; results of three pollutants model). The ozone association under heat wave was attributable to the statistical interaction between the heat wave and ozone. Conclusions : These results support the possibility of a biological synergy between the heat wave and ozone, one that is not evident between the heat wave and other major pollutants like particles or $SO_2$.

  • PDF

Heat Flow Analysis in the Newly Developed Wave Heat Sink by Computational Simulation (전산모사에 의한 웨이브 히트싱크의 열유동 특성 해석)

  • Lee In-Gyu;Lee Sang-Woong;Kang Kae-Myung;Chang Si-Young
    • Korean Journal of Materials Research
    • /
    • v.14 no.12
    • /
    • pp.870-875
    • /
    • 2004
  • Heat flow characteristics in the newly developed Wave Heat Sink were analyzed under natural and forced convections by Icepak program using the finite volume method. Temperature distribution and thermal resistance of Wave Heat Sink with/without air vent hole on the top of fin were compared with those of a commercial Al extruded heat sink(Intel Heat Sink). Under the natural convection, the maximum temperature was $45.1^{\circ}C$ in the air vent hole typed Wave Heat Sink, which was superior to that of Intel Heat Sink. The thermal resistance was $2.51^{\circ}C/W$ in the air vent hole typed Wave Heat Sink, and it changed to $2.65^{\circ}C/W\;and\;2.16^{\circ}C/W$ with changes of gravity direction and fin height, respectively. Under the forced convection, the maximum temperature became lower than that under the natural convection. In addition, the thermal resistance lowered in the air vent hole typed Wave Heat Sink with higher fin height and it decreased with increasing the air flux.

Experimental study of air side pressure drop and heat transfer characteristics of wave and wave-slit fin-tube heat exchangers (웨이브 및 웨이브-슬릿 열전달촉진 휜-관 열교환기의 공기측 압력강하 및 열전달 특성에 관한 실험)

  • Yoon, Baek;Gil, Yong-Hyun;Park, Hyun-Yeon;Yoo, Guk-Chul;Kim, Young-Saeng
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.10 no.5
    • /
    • pp.589-599
    • /
    • 1998
  • Air side heat transfer and pressure drop for fin-tube heat exchanger with wave and wave-slit fins were measured for various fin spacings and number of tube rows. Outer diameter of the tube including fin collar is 10.07mm, and experiments were done with dry surface condition. Longitudinal and transverse tube spacings of the heat exchangers are 21.65mm and 25mm respectively, and wave depth of the wave fin is 2mm. Experiments were conducted for 1, 2 and 3 rows and 3 different fin spacings, 1.3, 1.5 and 1.7mm. An attempt was made to demonstrate advantage of the enhanced fins over the plane fin by introducing the concept of fan power, Effect of the number of tube rows on heat transfer was discussed in connection with general mechanisms of heat transfer enhancement for fin-tube heat exchanger. Also the effect of hydrophilic coating was investigated. Lastly, correlations for Colburn j-factor and friction factor were developed.

  • PDF

Comparative Analysis of the Parabolic and Hyperbolic Heat Conduction and the Damped Wave in a Finite Medium (유한한 평판에서 포물선형 및 쌍곡선형 열전도 방정식과 파동 방정식의 비교 해석)

  • Park, S.K.;Lee, Y.H.
    • Journal of Power System Engineering
    • /
    • v.3 no.3
    • /
    • pp.14-21
    • /
    • 1999
  • The wave nature of heat conduction has been developed in situations involving extreme thermal gradients, very short times, or temperatures near absolute zero. Under the excitation of a periodic surface heating in a finite medium, the hyperbolic and parabolic heat conduction equations and the damped wave equations in heat flux are presented for comparative analysis by using the Green's function with the integral transform technique. The Kummer transformation is also utilized to accelerate the rate of convergence of these solutions. On the other hand, the temperature distributions are obtained through integration of the energy conservation law with respect to time. For hyperbolic heat conduction, the heat flux distribution does not exist throughout all the region in a finite medium within the range of very short times(${\xi}<{\eta}_l$). It is shown that due to the thermal relaxation time, the hyperbolic heat conduction equation has thermal wave characteristics as the damped wave equation has wave nature.

  • PDF

Relationship between the Spatial Allocation of Developed Area and the Heat Wave Phenomenon: The Case of Five Metropolitan Cities (시가화지역 공간상 위치분배와 폭염현상과의 관계성: 5개 광역시 사례)

  • Kang, Sangjun
    • Journal of Environmental Impact Assessment
    • /
    • v.30 no.3
    • /
    • pp.175-185
    • /
    • 2021
  • To better understand the heat wave phenomenon in the urban areas, it is desirable to explore the relationship between spatial allocation of land use and the heat wave. The purpose of this paper is to investigate the ranking correlation between heat wave days and developed types, specifically, core and islet developments. The methods employed are morphological spatial pattern, spatial autocorrelation, and spearman ranking correlation analyses by using the 30-year annual heat wave day records forthe five metropolitans. This research indicates that a fragmented development pattern including islets has mostly negative effects to the urban heat wave phenomenon. It means there is a relation between development pattern and heat wave.

Experimental Study of Air Side Pressure Drop and Heat Transfer Characteristics of Enhanced Fin-Tube Heat Exchangers (열전달 촉진 핀-관 열교환기의 공기측 압력강화 및 열전달 특성에 관한 실험)

  • Youn, Baek;Kil, Yong Hyun;Park, Hyun Yeon;Kim, Young Saeng
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.22 no.11
    • /
    • pp.1555-1563
    • /
    • 1998
  • Heat transfer and pressure drop for ${\phi}10.07$ dry surface fin-tube heat exchanger with wave and wave-slit fins were measured for different fin spacings and number of tube rows. Longitudinal and transverse tube spacings of the heat exchangers are 21.65mm and 25mm respectively, and wave depth of wave fin is 1.5mm. The experiments were performed for 4 different fin spacings, 1.3, 1.5, 1.7 and 2.0mm, and the number of tube rows were 1,2 and 3 rows. The present results were compared with the previous results for the wave depth of 2mm. Also hydrophilic coated and bare fins were tested. Correlations for Colburn j-factor and friction factor were developed.

Development of an Cross Flow Air-Cooled Plate Heat Exchanger (직교류 공랭식 판형열교환기의 성능평가)

  • Kim, Min-Sung;Lee, Jae-Hoon;Park, Seong-Ryong;Ra, Ho-Sang;Jeong, Jae-Hoon;Lim, Hyug
    • Proceedings of the SAREK Conference
    • /
    • 2007.11a
    • /
    • pp.235-240
    • /
    • 2007
  • Performance of an air-cooled plate heat exchanger (PHE) was evaluated in this study. The PHE was manufactured in two types of single-wave and double-wave plates in parallel assembly. The heat exchanger aims to substitute open-loop cooling towers with closed-loop water circulation, which guarantees cleanliness and compactness. In this study, prototype single-wave and double-wave PHEs were designed and tested in a laboratory scale experiments. From the tests, the double-wave PHE shows approximately 50% enhanced heat transfer performance compared to the single-wave PHE. However, the double-wave PHE costs 30% additional pressure drop. For the commercialization, a wide channel design for air flow would be essential for performance and reliability.

  • PDF

Analysis on the Effects of Land Cover Types and Topographic Features on Heat Wave Days (토지피복유형과 지형특성이 폭염일수에 미치는 영향 분석)

  • PARK, Kyung-Hun;SONG, Bong-Geun;PARK, Jae-Eun
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.19 no.4
    • /
    • pp.76-91
    • /
    • 2016
  • The purpose of this study is to analyze the effects of spatial characteristics, such as land cover and topography, on heat wave days from the city of Milyang, which has recently drawn attention for its heat wave problems. The number of heat wave days was calculated utilizing RCP-based South Korea climate data from 2000 to 2010. Land cover types were reclassified into urban area, agricultural area, forest area, water, and grassland using 2000, 2005, and 2010 land cover data constructed by the Ministry of Environment. Topographical features were analyzed by topographic position index (TPI) using a digital elevation model (DEM) with 30 m spatial resolution. The results show that the number of heat wave days was 31.4 days in 2000, which was the highest, followed by 26.9 days in 2008, 24.2 days in 2001, and 24.0 days in 2010. The heat wave distribution was relatively higher in agricultural areas, valleys, and rural areas. The topography of Milyang contains more mountainous slope (51.6%) than flat (19.7%), while large-scale valleys (12.2%) are distributed across some of the western region. Correlation analysis between heat wave and spatial characteristics showed that the correlation between forest area land cover and number of heat wave days was negative (-0.109), indicating that heat wave can be mitigated. Topographically, flat areas and heat wave showed a positive correlation (0.305). These results provide important insights for urban planning and environmental management for understanding the impact of land development and topographic change on heat wave.

Development of Heat Wave Indices for Korean Peninsula

  • Chandrasekara, Sewwandhi S.K.;Kwon, Hyun-Han
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2020.06a
    • /
    • pp.366-366
    • /
    • 2020
  • The drought is one of the extreme natural disasters observed in any climate zone and it is due to the deficiency in moisture. The flash drought is identified recently as a subdivision of drought and it is an extreme event distinguished by sudden onset and rapid intensification of drought conditions with severe impacts. The main cause for the flash drought is coupled situation due to precipitation deficit and high evapotranspiration. Hence, heat waves plays major role in identification of flash drought. Therefore, this study focused on identifying changes in distribution of heat waves for Korean Peninsula. The daily maximum and minimum temperature data were used in this study. The heat wave, heat wave intensity and heat wave intensity index were derived. The results of the study would be an input for the future studies on identification of flash drought in Korean Peninsula.

  • PDF