• Title/Summary/Keyword: Heat-stress

Search Result 2,810, Processing Time 0.031 seconds

Pectinase-treated Panax ginseng protects against chronic intermittent heat stress-induced testicular damage by modulating hormonal and spermatogenesis-related molecular expression in rats

  • Kopalli, Spandana Rajendra;Cha, Kyu-Min;Lee, Sang-Ho;Ryu, Ji-Hoon;Hwang, Seock-Yeon;Jeong, Min-Sik;Sung, Jong-Hwan;Kim, Si-Kwan
    • Journal of Ginseng Research
    • /
    • v.41 no.4
    • /
    • pp.578-588
    • /
    • 2017
  • Background: Elevated testicular temperature disrupts spermatogenesis and causes infertility. In the present study, the protective effect of enzymatically biotransformed Panax ginseng Meyer by pectinase (GINST) against chronic intermittent heat stress-induced testicular damage in rats was investigated. Methods: Male Sprague-Dawley rats (4 wk old, 60-70 g) were divided into four groups: normal control (NC), heat-stress control (HC), heat-stress plus GINST-100 mg/kg (HG100), and heat-stress plus GINST-200 mg/kg (HG200) treatment groups. Each dose of GINST (100 mg/kg and 200 mg/kg) was mixed separately with a regular pellet diet and was administered orally for 24 wk. For inducing heat stress, rats in the NC group were maintained at $25^{\circ}C$, whereas rats in the HC, HG100, and HG200 groups were exposed to $32{\pm}1^{\circ}C$ for 2 h daily for 6 mo. At week 25, the testes and serum from each animal were analyzed for various parameters. Results: Significant (p < 0.01) changes in the sperm kinematic values and blood chemistry panels were observed in the HC group. Furthermore, spermatogenesis-related molecules, sex hormone receptors, and selected antioxidant enzyme expression levels were also altered in the HC group compared to those in the NC group. GINST (HS100 and HS200) administration significantly (p < 0.05) restored these changes when compared with the HC group. For most of the parameters tested, the HG200 group exhibited potent effects compared with those exhibited by the HG100 group. Conclusion: GINST may be categorized as an important medicinal herb and a potential therapeutic for the treatment of male subfertility or infertility caused by hyperthermia.

Beet pulp as soluble fiber source and dietary energy levels for growing pigs under heat stress

  • Yo Han Choi;Ye Jin Min;Da Yeon Jeon;Hyun Ju Jin;Yong Dae Jeong;Hyun Ju Park;Abdolreza Hosseindoust;Sang Hun Ha;Jun Young Mun;Jin Soo Kim;Jo Eun Kim
    • Journal of Animal Science and Technology
    • /
    • v.65 no.5
    • /
    • pp.989-1001
    • /
    • 2023
  • The study evaluated the effects of dietary fiber and energy levels administered during two growing periods (d 0-28 and d 29-56) for pigs exposed to a high temperature. A total of 96 growing pigs were used in six treatments as: Two treatments in thermoneutral temperature (21℃-24℃) with dietary energy of 3,300 and the inclusion of high or low fiber, two treatments in heat stress (30℃-34℃) with dietary energy of 3,300 and the inclusion of high or low fiber, and two treatments in heat stress with dietary energy of 3,450 and the inclusion of high or low fiber. Among standard energy level treatments, heat-stressed pigs showed lower average daily gain (ADG), feed intake, digestibility of dry matter, gross energy, crude protein, and crude fiber in phases 1 and 2. Moreover, higher concentrations of acetate, propionate, butyrate, and total short-chain fatty acid (SCFA) in feces were shown in pigs fed high fiber diets. There was a negative interaction between dietary fiber and energy for the fecal concentration of isobutyrate in phase 1 and valerate in phase 2. Pigs in heat stress treatments showed a higher rectal temperature, respiratory rate, hair cortisol, plasma zonulin, and fecal lipocalin-2. Among heat stress treatments, the overall ADG was increased in pigs fed high fiber. Pigs fed high dietary fiber showed a greater concentration of acetate, propionate, butyrate, and total SCFA. High fiber treatments decreased plasma zonulin. In conclusion, the inclusion of beet pulp, soluble fiber, at the level of 4% looks necessary in pigs diet during heat stress.

Estimation of Fatigue Life in Butt-Welded Zone of SM45C Steel Rod (강 봉(SM45C) 맞대기 용접부의 피로수명 평가)

  • Oh, Byung-Duck;Lee, Yong-Bok
    • Journal of Welding and Joining
    • /
    • v.26 no.3
    • /
    • pp.45-50
    • /
    • 2008
  • SM45C steel rods being used generally for power transmission shafts and machine components was selected and welded by Butt-GMAW(Gas Metal Arc Welding) method. An estimation of fatigue life was studied by constructing S-N curve. Fatigue strength of base metal zone showed higher values than one of weld zone in low cycles between $10^4$ and $10^6$cycles. However, significant decrease in fatigue strength of base metal was found around $10^6$cycles, which were almost same as one of heat affected zone. This decrease was attributed that initial residual stress of the steel rods distributed by drawing process was diminished by continually applied load, and resulted in softening of base metal. The fatigue limit of the weld zone was highest in the boundary between deposited metal zone and heat affected zone, and followed by in the order of deposited metal zone, base metal zone, and heat affected zone. Based on these results, it is revealed that the stress for safety design of machine components using SM45C butt-welded steel rods must be selected within the region of the lowest fatigue limit of heat affected zone.

Performance of the Pigs Maintained in a Highland and Coastal Area of Minahasa Region, North Sulawesi

  • Umboh, J.F.;Tulung, B.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.14 no.7
    • /
    • pp.1014-1018
    • /
    • 2001
  • Pigs respond to extreme temperature (very cold or hot) by physiological and nutritional adjustments. Yet little is known about the effects of different environmental temperature (thermoneutral in the highland area, and hot temperature in the coastal area) where pigs are maintained on the performance of the pigs. Ten pigs each (10 pairs of littermates) were assigned to two treatments (2 locations): highland area (control=CA) or coastal area (hot/heat stress=HS). Experimental design was Paired 't' test. HS pigs had higher average daily water intake (p<0.05) compared to CA pigs (6,05 vs 3.89 kg/d), CA pigs had higher feed intake compared to HS pigs (2.9 vs 1.95 kg/d, p<0,05). CA pigs had higher daily gain compared to HS pigs (0.72 vs 0.58 kg/d, p<0.05). Feed conversion was not significantly different between CA pigs and HS pigs. The digestibility of dry matter, N, Na, K, Mg, CI, Ca and P was not significantly affected by the treatments. High environmental temperature in the coastal area (heat stress) increased water intake, decreased voluntary feed intake and daily gain of the pigs. The results demonstrate that different environmental temperature in the coastal area (heat stress) and highland area (control) had no pronounced effect on digestibility of nutrients.

A Study on the Heat Transfer Analysis and Thermal Stress Analysis of Mass Concrete Structure by Finite Element Method (유한요소법을 이용한 매스콘크리트구조물의 수화열 및 온도응력 해석에 관한 연구)

  • 강석화;이용호;정한중;박칠림
    • Magazine of the Korea Concrete Institute
    • /
    • v.7 no.3
    • /
    • pp.137-148
    • /
    • 1995
  • In this study, a program for evaluation of heat transfer and thermal stress of mass concrete is developed and verified by 2-experiments (internally and externally restricted). Furthermore, the result of the program is compared with those of ADINA-T and ADINA. As a result of the comparison, the proposed method produces comparable results with those from the popular programs (ADIIVA-T and ADINA) and shows the usefulness of the developed program for the evaluation of thermal stresses of mass concrete in both internally and externally restricted structures.

A Study On the Structure and Mechanical Properties of Isothermally Annealed after Elevated heating of PET filaments (ET filament의 승온열처리에 의한 구조 및 물성에 관한 연구)

  • Lee, Eun-Woo
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.6 no.4
    • /
    • pp.387-392
    • /
    • 2003
  • The change of crystalline structure and mechanical properties of PET filaments were investigated. Samples were treated by isothermally annealed after elevated heating. Measurements were carried out of density gradient tube for crystallinity and UTM for initial modulus and yield stress. Isothermally heat treatment were carried out $100^{\circ}C$, $120^{\circ}C$, $140^{\circ}C$ for 10min., 30min., 60min, in silicon oil bath. And isothermally heat treatment after elevated heating from $20^{\circ}C$ were carried out $100^{\circ}C$, $120^{\circ}C$, $140^{\circ}C$ for 10min., 30min., 60min., with heating rate of $5^{\circ}C/min$., $10^{\circ}C/min$. From the results of this study, it found the following facts. It was found that the crystallinity, initial modulus and yield stress of samples were increased with increasing of annealed temperature and time. Also crystallinity, initial modulus and yield stress of samples which were isothermally annealed after elevated heating from $20^{\circ}C$ were larger than those of isohtermally annealed samples.

  • PDF

Thermal Stress Analysis of the Support System in Cryogenic Liquid Hydrogen Storage Tank (극저온 액체수소 저장탱크 지지시스템의 열응력 해석)

  • Park, Dong-Huen;Yun, Sang-Kook;Lee, Jung-Hyan;Jo, Won-Il;Baek, Young-Sun
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2005.06a
    • /
    • pp.239-245
    • /
    • 2005
  • The reduction of heat transfer rate to the stored liquid hydrogen from outside condition is extremely important to keep the liquid hydrogen longer. In this paper the highly efficient support system for the liquid hydrogen storage vessel was newly developed and analysed. The support system was composed of a spherical ball in the center of supporter to reduce the heat transfer area, with its above and below supporting blocks which are the SUS and PTFE blocks inserted in the SUS tube. The heat transfer rate and temperature distribution of the support system were evaluated by FLUENT, and the thermal stress and strain were estimated by ANSYS software. The results showed that the heat transfer rate from outer vessel to inner one was extremely decreased compared with the common method which is simply SUS tubes inserted between inner and outer tanks. The thermal stress and strain were obtained well below the limited values. As a result, it was the most efficient support system of storage vessel for liquid hydrogen and most cryogenic fluids.

  • PDF

A Study on the Thermal and Mechanical Characteristic of Hybrid Welded Ship Structure A-grade Steel (선체구조용 A급 강재의 하이브리드 용접에 대한 열 및 역학적 특성에 관한 연구)

  • Oh, Chong-In;Kim, Young-Pyo;Park, Ho-Kyung;Bang, Han-Sur
    • Journal of Ocean Engineering and Technology
    • /
    • v.21 no.1 s.74
    • /
    • pp.64-68
    • /
    • 2007
  • Recently, there has been considerable research in the field of application of Laser-Arc hybrid welding for superstructures, such as ship-structures, transport vehicles etc. However, the study on heat distribution and welding residual stress of hybrid weld by numerical simulation leaves much to be desired. Therefore, in this study, an optimized welding condition and numerical simulation for hybrid welding, using previous numerical analysis to calculate the heat source for hybrid welding, has been analyzed. For this purpose, fundamental welding phenomena of the hybrid process, using Laser and, is investigated. In order to calculate temperature and residual stress distribution in hybrid welds, a finite element heat source model is developed on the basis of experimental results and characteristics of temperature. Residual stress distribution in hybrid welds are understood from the result of simulation, and compared with the experimental values.

Sliding Wear Characteristics of plasma Sprayed $8\%Y_{2}O_3-ZrO_2$ Coating for Post-spray Heat Treatment

  • Chae Young-Hun;Kim Seock-Sam
    • KSTLE International Journal
    • /
    • v.6 no.2
    • /
    • pp.45-50
    • /
    • 2005
  • Plasma ceramic spray that is applied on a machine part under severe work conditions has been investigated for tribological behavior. The application of ceramic coatings by plasma spray has become essential in tribosystems to produce wear resistance and long life in severe conditions. The purpose of this study was to investigate the wear characteristics of $8\%Y_{2}O_3-ZrO_2$ coating, in view of the effect of post-spay heat treatment. The plasma-sprayed $8\%Y_{2}O_3-ZrO_2$ coating was studied to know the relationship between phase transformations and wear behavior related to post-spray heat treatment. Wear test was carried out with ball on disk type on normal loads of 50N,70N and 90N under room temperature. The phase transformation of phase and the value of residual stress were measured by X-ray diffraction method(XRD). Tribological characteristics and wear mechanisms of coatings were observed by SEM. The tribological wear performance was discussed in the focusing of residual stress. Consequently, post-spray heat treatment plays an important role in decreasing residual stress. Residual stress in the coating system has a significant influence on the wear mechanism of coating.

Correcting Stress-Strain Curves of Nimonic 80A Alloy based on Direct Measurement of Barreling and Heat Generation (압축시험에서의 배럴링 및 소성발열 직접 측정에 의한 Nimonic 80A 합금의 응력-변형률 선도 보정)

  • S.H. Kang;H.W. Jung;H. Lee;S.J. Kim;Y.S. Oh;J. Jung;S. Oh;H. Kim
    • Transactions of Materials Processing
    • /
    • v.32 no.4
    • /
    • pp.215-220
    • /
    • 2023
  • In this study, the correction process of stress-strain curves obtained from hot compression test is introduced since the barreling induced by friction and adiabatic heat generation induced by plastic work occur under high strain rate. A shear friction factor was quantitatively estimated by measuring the dimension of barreling and temperature rise due to adiabatic heat generation was directly measured during compression test. Thereafter, the stress-strain curves were re-evaluated by introducing several equations to correct the effects of the friction and temperature rise. It was found that adiabatic factor at strain rate of 10/s is in the range of about 0.5 to 0.75 for Nimonic 80A and decreases as the assigned temperature increases.