• Title/Summary/Keyword: Heat-setting

Search Result 377, Processing Time 0.024 seconds

An analysis on the characteristics of superheater organization of ORC system for marine waste heat recovery system(WHRS) (선박폐열회수(WHRS) ORC 시스템의 과열기 구성에 따른 특성 해석)

  • Kim, Jong-Kwon;Kim, You-Taek;Kang, Ho-Keun
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.38 no.1
    • /
    • pp.8-14
    • /
    • 2014
  • This research designed Waste Heat Recovery System(WHRS) generation system of 250kW whose working fluid is R-245fa and studied on cycle characteristics by superheater organization. It simulated two conditions; series connection and parallel connection between superheater and evaporator. In simulation of series connection of superheater and evaporator, output of 4.7% could be improved because of the increase of enthalpy by overheating of working fluid. When setting 250kW for target output, cycle flux could be reduced by 4.1%. When setting 250kW as a target output of cycle In parallel connection simulation of superheater and evaporator, cycle flux was reduced as flux of heat source fluid for superheater was increased. So, the maximum 7.9% of working fluid pump's electric power was reduced and there was no big change in cycle efficiency and net efficiency by flux ratio.

Evaluation of the Nip Pressure Profile and Analysis of Heat Transfer in Soft Nip Calender (소프트닙 캘린더의 닙 압력 프로파일 평가와 닙 내 열전달 현상에 대한 해석)

  • 이사용;이학래;박선규
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.32 no.2
    • /
    • pp.26-34
    • /
    • 2000
  • Understanding the nip geometry and heat transfer phenomena of soft nip calenders, which has been used in the production of newsprint and coated papers for many years, is very important since improper setting of soft nip calendering conditions causes deterioration of paper quality and productivity. In this study theoretical analysis on nip pressure and heat transfer phenomena in the nip of soft nip calenders has been made. The variables examined were calendering pressure, surface temperature of the heating roll, nip residence time and ingoing sheet moisture, By measuring nip widths and maximum nip pressure with Prescale film at a normal temperature, accurate line load has been obtained. With this line load, nip pressures at different temperature and nip widths were calculated. Results showed that as temperature increased, nip widths increased and nip pressures decreased. Equations derived for the heat conduction phenomena in soft nip calender nip were derived based on the semi-infinite plate and finite difference method and were used for the analysis of heat transfer within the nip. Temperature profiles in z-direction of paper within the nip were obtained. Finite difference method allowed more accurate analysis of the heat transfer in the calender nip. In this study newsprint and coated paper were considered as a single plate and two-layer plate consisted of sheet and coating layers, respectively. Heat trans-fer to paper increased as heated roll surface temperature and nip residence time were increased.

  • PDF

Setting Shrinkage, Thermal Expansion Coefficient and Compressive Strength of Recycled PET Polymer Concrete with Montmorillonite (몬모릴로라이트를 이용한 재활용 PET폴리머 콘크리트의 경화수축, 온도팽창계수, 압축강도)

  • Jo Byong-Wan;Tae Ghi-Ho;Lee Du-Wha
    • Journal of the Korea Concrete Institute
    • /
    • v.16 no.2 s.80
    • /
    • pp.205-212
    • /
    • 2004
  • Recently, as concerns over environmental issues are raised more and more trend to use recycled waste for producing construction materials is also raised. Especially, a case of waste resin is considerably destroying the environment due to disposal way that most waste resin produced is disposed of landfill. This study is performed by polymer concrete with recycled PET resin in terms of obtaining safely clean construction resources and protection of environment. High setting shrinkage and sensitivity to heat are main disadvantages of Polymer Concrete (PC) despites of a lot merits. The aim of this study is to investigate basic properties such as setting shrinkage, length change and sensitivity to heat about PET recycled polymer concrete. The other is to check the possibility of use of Montmorillonite as one of a lot of additive without special coupling agent. As results of experiments, various properties of polymer concrete with recycled PET resin are similar with conventional PC except that polymerization time is longer. Montmorillonite was efficiently used to reduce setting shrinkage, length change and coenicient of thermal expansion related to heat with enhanced strength

ANALYSIS OF TEMPERATURE RISE ON THE ROOT SURFACE DURING CONTINUOUS WAVE OF CONDENSATION TECHNIQUE (Continuous Wave of Condensation Technique으로 근관충전시 치근면 온도상승 분석)

  • Kim, Young-Ju;Hwang, Yun-Chan;Kim, Sun-Ho;Hwang, In-Nam;Choi, Bo-Young;Jeong, Young-Jin;Juhng, Woo-Nam;Oh, Won-Mann
    • Restorative Dentistry and Endodontics
    • /
    • v.28 no.4
    • /
    • pp.341-347
    • /
    • 2003
  • This study was conducted to evaluate the temperature rise on the root surface while the root canal is being obturated using continuous wave of condensation technique. Maxillary central incisor was prepared for repeated canal obturation. Ten thermocouples (Omega Engineering Inc., Stanford, USA) were placed at 1 mm increment from the anatomical root apex. The real temperature of Buchanan plugger was recorded before insertion into the root canal. The root canal was obturated with continuous wave of condensation technique as described by Buchanan and the root surface temperature was recorded during obturation at $150^{\circ}C,{\;}200^{\circ}C,{\;}250^{\circ}C{\;}and{\;}300^{\circ}C$ temperature settings of System B HeatSource (Model 1005, Analytic technologies, Redmond, WA, USA). After completion of the temperature recording, the dentinal-cementum thickness at each sites was measured. The data were analyzed using one-way ANOVA followed by Scheffe's test and linear regression test. The results were as follows. 1. When the temperature was set at $150^{\circ}C,{\;}200^{\circ}C,{\;}250^{\circ}C{\;}and{\;}300^{\circ}C$ on the digital display of System B HeatSource, the real temperature of the plugger at the 1mm point from the tip revealed $130.82{\pm}2.96^{\circ}C,{\;}158.00{\pm}5.26^{\circ}C,{\;}215.92{\pm}6.91^{\circ}C{\;}and{\;}249.88{\pm}3.65^{\circ}C$ respectively. 2. The position of 8 mm from the anatomical apex showed the highest temperature increase at each temperature settings and it was significantly higher than those of other positions (p<0.0l). The temperature rise was constantly increased toward coronal portion from apex of the root. 3. The maximum temperature increase on the root surface was $2.37{\pm}0.09^{\circ}C{\;}at{\;}150^{\circ}C{\;}setting,{\;}3.11{\pm}0.12^{\circ}C{\;}at{\;}200^{\circ}{\;}setting,{\;}3.93{\pm}0.09^{\circ}C{\;}at{\;}250^{\circ}C{\;}setting{\;}and{\;}5.69{\pm}0.15^{\circ}C{\;}at{\;}300^{\circ}C$ setting respectively. These results suggest that it be relatively kind to the supporting tissues of the root that the root canal is obturated using continuous wave of condensation technique at $150^{\circ}C,{\;}200^{\circ}C,{\;}250^{\circ}C{\;}and{\;}300^{\circ}C$ temperature settings on digital temperature display of System B HeatSource.

A Study on high Quality of Antiwashout Underwater Concrete (수중불분리성콘크리트의 고품질화 연구)

  • 문한영;김성수;전중규;송용규
    • Journal of the Korea Concrete Institute
    • /
    • v.12 no.5
    • /
    • pp.111-120
    • /
    • 2000
  • In case of constructing concrete structure under water, generally concrete mixed with antiwashout admixture, high range water reducer, or AE-water reducing agent etc has been manufactured to ensure the quality of antiwashout underwater concrete because of being difficulty in ascertaining construction situation by the naked eye. The properties of high quality antiwashout underwater concrete that were aimed at affluent fluidity, workability and the compressive strength of 450 kgf/$\textrm{cm}^2$ at 28 ages using two types of blended cements are following as;(1) Setting time of antiwashout underwater concretes using blended cements was more greatly delayed than that of control concrete, however, was satisfied with criteria value of "Quality standard specification of antiwashout admixture for concrete".(2) As a test results of slump flow, efflux time and box elevation of head, it was found that workability of high quality antiwashout underwater concrete was improved. (3) Heat evolution amount of OPC was 1.5 times as high as that of two types of bended cements in 72 hours. (4) Suspended solids of antiwashout underwater concrete using blended cements was more than that of control concrete, also compressive strength of high quality antiwashout underwater concrete was very low in early age, but was better than that of control concrete as to increasing ages.

A Study on the Engineering Properties of Concrete Using Blast-furnace Slag Powder (고로슬래그 미분말을 사용한 콘크리트의 공학적 특성에 관한 연구)

  • Lee, Sang-Soo;Won, Cheol;Kim, Dong-Seok;Park, Sang-Jun
    • Journal of the Korea Concrete Institute
    • /
    • v.12 no.4
    • /
    • pp.49-58
    • /
    • 2000
  • There are many methods to improve the performance of concrete. Especially, granuated blast furnace slag. by-products used in concrete as the replacement material of cement, could contribute to improve the fluidity, resistance of chemical attack and strength of concrete. Also, it could contribute to decrease the rate of generating hydration heat, in addition to cost-down of concrete and prevention of enviromental pollution. Therefore, in order to establish the systemical application of granuated blast furnace slag in normal concrete, the engineering properties of concrete, such as fluidity, strength, setting and hydration properties etc.. was evaluated. In this study, replacement ratio of granuated blast furnace slag was 0, 30, 50, 70(%), and target slump was 8, 12, 15, 18(cm). Results from the experiment, granuated blast furnace slag showed the outstanding effects of improving the engineering properties of concrete. From now on, positive application of granuated blast furnace slag is expected in the point of improving the performance and cost-down of concrete.

Improvement of Heat Pump Heating Performance by Selective Heat Storage Using Air Heat of Inside and Outside Greenhouse (온실 내외부 공기열의 선택적 축열에 의한 히트펌프 난방성능 개선)

  • Kwon, Jin Kyung;Kim, Seung Hee;Jeon, Jong Gil;Kang, Youn Koo;Jang, Kab Yeol
    • Journal of Bio-Environment Control
    • /
    • v.26 no.4
    • /
    • pp.353-360
    • /
    • 2017
  • In this study, the design and performance test of the air to water heat pump capable of producing hot water for greenhouse heating by using the surplus solar heat inside the greenhouse and the air heat outside greenhouse as the selective heat source were conducted. The heat storage operations using the surplus solar heat and the outside air heat were designed to be switched according to the setting temperature of the greenhouse in consideration of the optimum temperature range of the crop. In the developed system, it was possible to automatically control the switching of heat storage operation, heating and ventilation by setting 12 reference temperatures on the control panel. In the selective heat storage operation with the surplus solar heat and outside air heat, the temperature of thermal storage tank was controlled variably from $35^{\circ}C$ to $52^{\circ}C$ according to the heat storage rate and heating load. The heat storage operation times using the surplus solar heat and outside air heat were 23.1% and 30.7% of the experimental time respectively and the heat pump pause time was 46.2%. COP(coefficient of performance) of the heat pump of the heat storage operation using the surplus solar heat and outside air heat were 3.83 and 2.77 respectively and was 3.24 for whole selective heat storage operation. For the comparative experiment, the heat storage operation using the outside air heat only was performed under the condition that the temperature of the thermal storage tank was controlled constantly from 50 to $52^{\circ}C$, and COP was analyzed to be 2.33. As a result, it was confirmed that the COP of the heat storage operation using the surplus solar heat and outside air heat as selective heat source and the variable temperature control of the thermal storage tank was 39% higher than that of the general heat storage operation using the outside air heat only and the constant temperature control of the thermal storage tank.

A Study on the Geothermal Heat Pump System Performance Analysis according to Water Flow Rate Control of the Geothermal Water Circulation Pump (지열순환펌프 유량변화에 따른 지열히트펌프시스템의 에너지 성능 평가)

  • Jung, Young-Ju;Jo, Jae-Hun;Kim, Yong-Shik;Cho, Young-Hum
    • Journal of the Korean Solar Energy Society
    • /
    • v.34 no.6
    • /
    • pp.103-109
    • /
    • 2014
  • It is important to control the amount of supply water flow rate at all kinds of HVAC systems in order to maintain IAQ and energy efficiency. The most of buildings installed geothermal heat pumps is using fixed water flow rate in spite of the excellent performance of geothermal heat pumps. Especially when the air-conditioning load is low, the flow rate control may be possible to save energy to operate. However, it is effective to apply the variable flow control system in order to reduce energy consumption. Therefore, the purpose of this study, change a water flow rate and improve the whole performance of the geothermal heat pump. Geothermal heat pump system is modeled after the selection of the applied building, by setting the flow rate control to be analyzed through a simulation of performance evaluation. Building energy saving according to the flow rate of the ground circulating water analyze quantitatively and to investigate the importance of the flow control.