• 제목/요약/키워드: Heat-resistance

검색결과 2,894건 처리시간 0.048초

A Study on the Properties of Low-Heat Cement Concrete (저발열시멘트 콘크리트의 기초적 성질에 대한 연구)

  • 문한영;김성수;신화철;강석화
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 한국콘크리트학회 1997년도 가을 학술발표회 논문집
    • /
    • pp.57-60
    • /
    • 1997
  • The properties of Low-heat cement are especially in lower heat of hydration than that of other types of cement. In other respect, Low-heat concrete is more advantageous than OPC concrete in chemical resistance, long term age compressive strength, slump loss and resistance to seawater. This paper deals with 28 days age compressive strength and slump loss by elapsed time of mortar and concrete that made with Low-heat cement and 3 types of other cement.

  • PDF

A Study on the Heat Transfer Enhancement of Miniature loop Heat Pipes by Using the Cu Nanofluids

  • Kim, Young-Sik;Jeong, Hyo-Min;Chung, Han-Shik;Tanshen, Md.Riyad;Lee, Dae-Chul;Ji, Myoung-Kuk;Bae, Kang-Youl
    • Journal of Power System Engineering
    • /
    • 제17권2호
    • /
    • pp.70-77
    • /
    • 2013
  • An experimental study was carried out to understand the heat transfer performance of a miniature loop heat pipes using water-based copper nanoparticles suspensions as the working fluid. The suspensions consisted of deionized water and copper nanoparticles with an average diameter of 80 nm. Effects of the cupper mass concentration and the operation pressure on the average evaporation and condensation heat transfer coefficients, the critical heat flux and the total heat resistance of the mLHPs were investigated and discussed. The pressure frequency also depends upon the evaporator temperature which has been maintained from $60^{\circ}C$ to $90^{\circ}C$. The Investigation shows 60% filling ratio gives the highest inside pressure magnitude of highest number pressure frequency at any of setting of evaporator temperature and 5wt% results the lowest heat flow resistance.

An Experimental Study on the Heat Transfer Characteristics of a High-temperature Sodium Heat Pipe Depending on the Thermal Transport Conditions (고온 나트륨 히트파이프에서 열이송 조건에 따른 열전달 특성에 대한 실험 연구)

  • Park, C.M.;Boo, J.H.;Kim, J.S.
    • Proceedings of the KSME Conference
    • /
    • 대한기계학회 2008년도 추계학술대회B
    • /
    • pp.2340-2345
    • /
    • 2008
  • Cylindrical stainless-steel/sodium heat pipe for a high-temperature application was manufactured and tested for transient and steady-state operations. Two layers of Stainless-steel screen mesh wick was inserted as a capillary structure. The outer diameter of the heat pipe was 12.7 mm and the total length was 250 mm. As thermal transport conditions, the effective transport length, the heat flux, the tilt angle and the operating temperature were varied. The heat was supplied by an electric furnace up to 1 kW and the cooling was performed by forced convection of air. The effective thermal conductivity and the thermal resistance were investigated as a function of heat flux, heat transport length, and vapor temperature. Typical range of the total thermal resistance was as low as $0.036^{\circ}C/W$ at $175.8\;kW/m^2$ of heat flux and $700^{\circ}C$ of operating temperature.

  • PDF

An Experimental Investigation on the Operating Characteristics of a Reversible Loop Heat Pipe (가역 루프 히트파이프의 작동특성에 관한 실험적 연구)

  • Kim Bong-Hun;Choi Joon-Min
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • 제18권3호
    • /
    • pp.231-239
    • /
    • 2006
  • An experimental investigation of a Reversible Loop Heat Pipe (RLHP) was conducted to determine the operating limits and performance characteristics as functions of the thermophysical parameters, the heat input, and the cooling intensity. Variations in both temperature and heat transport capacity were measured and analyzed in order to accurately evaluate the transient operating characteristics. In addition, the maximum heat transport as a function of the mean evaporator temperature, the ratio of heat transport to heater input power as a function of the mean evaporator temperature, and the overall thermal resistance as a function of the overall heat transport capacity were examined as well. Results indicated that the cooling intensity played an important role on the operating characteristics and performance limitation. The maximum heat transports corresponding to cooling intensity $72W/^{\circ}C$ and $290W/^{\circ}C$ were 446 W and 924 W, respectively. Also, observation of the startup characteristics indicated that the mean evaporator temperature should be maintained between $40^{\circ}C$ and $60^{\circ}C$, and overall thermal resistance were measured as $0.02^{\circ}C/W$.

A Study on Grooving Corrosion at the Weld of a Low Carbon Steel Pipe Made by Electrical Resistance Welding (탄소강관의 ERW 용접부 홈부식 손상에 관한 연구)

  • Kim Yong;Lee Bo-Young
    • Journal of Welding and Joining
    • /
    • 제22권5호
    • /
    • pp.58-64
    • /
    • 2004
  • Although leakage at a low carbon steel pipe made by electrical resistance welding (ERW) was reported due to grooving corrosion, the cause for the corrosion has not yet been cleared. In order to clarify the main cause, failure analysis on the leaked pipe was carried out, followed by metallographic investigation and corrosion test for the various ERW pipe made with different welding heat input. The microstructure, particularly inclusion content, of the weldment is dependant on the welding heat input applied. For an improper low heat input, the amount of inclusion at the weld was high. High inclusion content accelerated grooving corrosion at the weld. It is therefore that welding heat input should be controlled based on the carbon content of the pipe in order to improve the corrosion resistance of the ERW pipe.

Mechanical Characteristics when Wire Electrical Discharge Machining and Surface Grinding for Titanium Alloy (티타늄합금의 와이어 방전가공과 연삭가공시 기계적 특성)

  • 김종업;왕덕현;김원일;이윤경
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 한국공작기계학회 2001년도 추계학술대회(한국공작기계학회)
    • /
    • pp.172-178
    • /
    • 2001
  • Titanium alloys have lightness, high strength and good corrosion resistant characteristics, and broadly used in manufacturing parts for military and aerospace industries. And these alloys also are recognized for organism materials comparatively and used as fixing ones in the human body. Nevertheless thess alloys have excellent properties such as corrosion resistance, heat resistance, and good tensile strength, it is difficult to machine by traditional methods because of high hardness and chemically activated property. So higher tool wear is expected when cutting by tools. Therefore, it is required nontraditional machining process. And the mechanical characteristics such as surface structure and shape, hardness and bending strength are studied for wire electrical discharge machined and surface ground titanium alloys for various heat-treated conditions.

  • PDF

Quantitative Comparisons of the Characteristics of various Rapid Prototypes and RP machines (여러 가지 방식의 쾌속조형물 특성 및 장비 성능의 정량적 비교)

  • Kim, Gi-Dae
    • Proceedings of the KSME Conference
    • /
    • 대한기계학회 2007년도 춘계학술대회A
    • /
    • pp.1237-1242
    • /
    • 2007
  • For the various RP processes and machines, quantitative comparisons were carried out, which include the variations of roughness according to inclined angle of surface, tensile strength and heat-resistance, shape accuracy affected by curl distortion, manufacturability of submilli-scale structure, and manufacturing speed. It was observed that steeper surface results in smoother roughness except Eden500V of Objet. Specimen made by LOM process showed the best heat-resistance, but that of SL process had heat-resistance only up to $60^{\circ}C$. Generally, tensile strength in the building direction was shown to be smaller than in the scanning direction, but SL process showed the opposite results. RM6000II of CMET was superior in the manufacturing small-scale structure below 0.2mm, and Z510 of Zcorp. and ViperPRO of 3D systems were great in manufacturing speed.

  • PDF

Partial Heat Resistance of Hanbok When it Worn (한복 착용시의 부위별 열저항에 관한 연구)

  • 송명견
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • 제20권4호
    • /
    • pp.565-572
    • /
    • 1996
  • The purpose of this study was to measure partial heat resistance of Hanbok when it worn. Since Hanbok varies from season to season, four different set of Hanboks (R, SN, p and S) were tested. Also Durumagi (D) which is worn over Hanbok (5) to keep warm from winter cold was tested as well. The thermal manikin was used in this experiment. The room temperature, air velocity and the relative humidity was set at $20\pm0.5^{\circ}C$, 0.15 m/sec and $50\pm$5% respectively. The mean skin temperature of the manikin was set at $33\pm0.5^{\circ}C$. The results were as follows: 1. The order from the least total heat resistance to the most was SN, R, p, 5 and D. 2. Upper arms had the highest heat resistance among the 13 parts. The next was abdomen thighs, buttock, legs, forearms and chest, back, and head, the order from the most to the least.

  • PDF

THERMAL RESISTANCE OF BACTERIAL SPORES TO DRY HEAT (세균포자의 건열에 대한 열저항성)

  • HAN Bong-Ho
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • 제10권3호
    • /
    • pp.145-149
    • /
    • 1977
  • Thermal resistance of dried bacterial spores against dry heat was determined. Spare suspensions of Bacillus subtilis var. niger ATCC 9372, Bacillus stearothermophilus Oxoid Code BR 23 and Clostridium sporogenes ATCC 19404 were located on aluminium strips, dried in electric oven under vacuum at room temperature for 10 minutes. The aluminium strips were laid in the middle of gas flow (hot air and superheated steam) with the velocity of 6 m/sec and heated at $120^{\circ}C$ for 180 seconds. The calculated D-values showed that there were no remarkable differences in the heat resistance of bacterial spares between $R.H.\leqq0.012$ and R. H.=0.51. Furthermore the thermal resistance of B. subtilis spores to dry heat was greater than that of B. stearothermophilus.

  • PDF

The heat treatment characteristics of plasma sprayed ZrO$_2$-Y$_2$O$_3$ coatings (플라즈마 용해법에 의한 ZrO$_2$-Y$_2$O$_3$ 피복층의 가열처리효과)

  • 정병근;김한삼;김수식
    • Journal of the Korean institute of surface engineering
    • /
    • 제27권1호
    • /
    • pp.12-18
    • /
    • 1994
  • The plasma spray process was used to deposit coatings of $ZrO_2$-8wt%Y2O3 powders on mild steel sub-strate, and the characteristics of as-deposited and heat treated coatings have been investigated. Particulary, the variations of porosity, wear resistance, thermal barrier and thermal shock resistance in $ZrO_2$-8wt% $Y_2O_3$coatings after heat treatment under vacuum circumstance have been investigated. The porosity of the coating layer was increased with increased spray distance. In the case of the arc current of 450A and at the spray distance of 50mm, it was obtained the lowest amount of porosity. After heat treatment, the amount of porosity was found to be decreased, and the wear resistance, microhardness and thermal shock resistance were im-proved. However, the thermal barrier was decreased.

  • PDF