• 제목/요약/키워드: Heat-cool test

검색결과 49건 처리시간 0.021초

열처리 및 가열방식에 따른 Zr-2.5Nb 압력관의 수소지연균열 특성에 관한 연구 (A Study on the Characteristics of Delayed Hydride Cracking in Zr-2.5Nb Pressure Tube with the Heating-up and Heat-treatment)

  • 나은영
    • 한국해양공학회지
    • /
    • 제23권2호
    • /
    • pp.69-73
    • /
    • 2009
  • The objective of this study was to obtain a better understanding of the delayed hydride cracking (DHC) of Zr-2.5Nb alloy. The DHC model has some defects: first, it cannot explain why the DHC velocity (DHCV) becomes constant regardless of an applied stress intensity factor, even though the stress gradient is affected by the applied stress intensity factor at the notch tip. Second, it cannot explain why the DHCV has a strong dependence on the method of approaching the test temperature by a cool-down or a heating-up, even under the same stress gradient, and third, it cannot predict any hydride size effect on the DHC velocity. The DHC tests were conducted on Zr-2.5Nb compact tension specimens with the test temperatures reached by a heating-up method and a cool-down method. Crack velocities were measured in hydrided specimens, which were cooled from solution-treatment temperatures at different rates by being furnace-cooled, water-quenched, and liquid nitrogen-quenched. The resulting hydride size, morphology, and distributions were examined by optical metallography. It was found that fast cooling rates, which produce very finely dispersed hydrides, result in higher crack growth rates. This different DHC behavior of the Zr-2.5Nb tube with the cooling rate after a homogenization treatment is due to the precipitation of the $\gamma$-hydrides only in the water-quenched Zr-2.5Nb tube. This experiment will provide supporting evidence that the terminal solid solubility of a dissolution (TSSD) of $\gamma$-hydrides is higher than that of $\delta$-hydrides.

Assessment of Stability and Safety of Maskne Cosmetic

  • Minjung, Kim;Jeonghee, Kim
    • 패션비즈니스
    • /
    • 제26권6호
    • /
    • pp.105-115
    • /
    • 2022
  • Wearing a mask is still advised since COVID-19 continues to spread. However, masks may also irritate the skin and cause mask acne, often known as "maskne", which is a type of acne mechanica caused by friction between the skin and clothing. Therefore, there is a need to develop an effective maskne cosmetic. In this study, we made the maskne cosmetics containing humulus lupulus extract and copper tripeptide-1 and investigated its stability and safety. To measure stability, a centrifugation test and heat-cool cycling were done, and changes in viscosity and pH were measured for 8 weeks. The Cumulative Irritation Test (CIT, WKIRB-202111-HR-096) was performed and positive reactions were determined by the ICDRG criteria. The results indicated that the samples were stable after centrifugation, temperature cycling, viscosity, and pH tests. In addition, cosmetic safety test results revealed that maskne cosmetics containing humulus lupulus extract and copper tripeptide-1 did not cause any skin responses. These findings indicate that prepared maskne cosmetics' stability and safety were comparable to those of currently available commercial cosmetics.

단열성 시험 방법을 통한 진공유리의 구성 및 필러 배치에 따른 열 성능 평가 (The Evaluation of Thermal Performance of Vacuum Glazing by Composition and the Pillar Arrangement through Test Method of Thermal Resistance)

  • 조수;김석현;엄재용
    • 한국태양에너지학회 논문집
    • /
    • 제35권1호
    • /
    • pp.61-68
    • /
    • 2015
  • The advanced counties effort to the supplement of the zero energy buildings for the global building energy saving. In the middle of the development of passive technology, the government has to effort to the energy saving of buildings by enhanced performance of the window thermal insulation. By the method of enhanced performance of window thermal insulation, the use of vacuum double glazing saves the energy consumption in building. This glazing has low U-value(heat transmission coefficient) than normal double glazing. The vacuum glazing enhanced thermal insulation performance by vacuum space of between the glass and glass. For this vacuum glazing, pillar maintain the space between glass and glass. But this structure cause the raising the heat transmission coefficient in pillar approaching glass. This study confirmed the U-value by the test method of thermal resistance for windows and doors. Also this study confirmed the variation of heat transmission coefficient by the structure of vacuum glazing. And this study measured the surface temperature of the vacuum glazing about pillar approaching glass and vacuum space in cool chamber and hot box. That result, this study confirmed U-value of $0.422W/m^2{\cdot}K$ of vacuum glazing. Also this study confirmed U-value of $0.300{\sim}0.422W/m^2{\cdot}K$ by various the structure of vacuum glazing. And this study confirmed the heat flow in pillar approaching glass.

수소 Joule-Thomson냉동기의 성능실험 (Performance test of Joule-Thomson cryocooler with $H_2$gas)

  • 백종훈;강병하;홍성제;장호명
    • 설비공학논문집
    • /
    • 제11권4호
    • /
    • pp.457-463
    • /
    • 1999
  • The Joule-Thomson cryocooler with $H_2$gas has been developed. Cool-down characteristics and the cooling performance of a JT cryocooler have been investigated in detail. The JT cryocooler consists of JT expansion valve, heat exchanger, expansion chamber, compressed $H_2$gas storage tank, $LN_2$precooler, heater and a cryostat. The precooling process using both $GN_2$and $LN_2$was peformed to cool down the inside components of cryocooler under the maximum inversion temperature of $H_2$. The $H_2$expansion experiments have been peformed for 2-5MPa of H$_2$pressure to evaluate steady state temperatures of the cryocooler. It is found that the steady state temperatures are decreased as the H$_2$pressures are increased. The effects of cooling temperatures on the performance have been evaluated for various $H_2$and $N_2$pressures. It is seen that the cooling loads are increased, as the cooling temperature and operating pressure are increased.

  • PDF

Integral effect tests for intermediate and small break loss-of-coolant accidents with passive emergency core cooling system

  • Byoung-Uhn Bae;Seok Cho;Jae Bong Lee;Yu-Sun Park;Jongrok Kim;Kyoung-Ho Kang
    • Nuclear Engineering and Technology
    • /
    • 제55권7호
    • /
    • pp.2438-2446
    • /
    • 2023
  • To cool down a nuclear reactor core and prevent the fuel damage without a pump-driven active component during any anticipated accident, the passive emergency core cooling system (PECCS) was designed and adopted in an advanced light water reactor, i-POWER. In this study, for a validation of the cooling capability of PECCS, thermal-hydraulic integral effect tests were performed with the ATLAS facility by simulating intermediate and small break loss-of-coolant accidents (IBLOCA and SBLOCA). The test result showed that PECCS could effectively depressurize the reactor coolant system by supplying the safety injection water from the safety injection tanks (SITs). The result pointed out that the safety injection from IRWST should have been activated earlier to inhibit the excessive core heat-up. The sequence of the PECCS injection and the major thermal hydraulic transient during the SBLOCA transient was similar to the result of the IBLOCA test with the equivalent PECCS condition. The test data can be used to evaluate the capability of thermal hydraulic safety analysis codes in predicting IBLOCA and SBLOCA transients under an operation of passive safety system.

한전 초전도전력케이블 냉각시스템 성능시험 (Performance Test of Cooling System for the KEPCO HTS Power Cable)

  • 양형석;김동락;손송호;임지현;최하옥;이병섭;최연석;류희석;황시돌
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회B
    • /
    • pp.2206-2210
    • /
    • 2007
  • As a power transmission line supplying power to a densely populated city, the high temperature superconducting (HTS) cable is expected to one of the most effective cables with a compact size because of its high current density. The verification of HTS power cable system have been progressed by KEPRI. A cooling system for a 3-phase 100m HTS power cable with 22.9kV/1.25kA was installed and tested at KEPCO's Gochang power testing center in Korea. The system consists of a liquid nitrogen decompression cooling system with a cooling capacity of 3kW and a closed circulation system of subcooled liquid nitrogen. Several performance tests of the cable system with respect to the cooling such as cooling capacity, heat load and temperature stability, were performed at several temperatures. Thermal cycle test, cool-down to liquid nitrogen temperature and warm-up to room temperature, was also performed to investigate thermal cycle influences. The outline of the installed cooling system and performance test results are presented in this paper.

  • PDF

Study on Reliability of Water Absorption Diagnosis through Precise Water Absorption Test

  • Kim, Hee-Soo;Bae, Yong-Chae;Kim, Hee-Dong
    • Journal of Electrical Engineering and Technology
    • /
    • 제7권5호
    • /
    • pp.772-777
    • /
    • 2012
  • Accidents caused by water absorption in water-cooled generator stator windings often occur all over the world. The absorption into the insulator of the coolant, which is used to cool down the heat generated by stator windings during operation, leads to the deterioration of dielectric strength, and insulation breakdown. An insulation breakdown may cause not only an enormous economic loss but also a very serious grid accident that would compromise stable supply of electric power. More than 50 % of domestic generators have been in operation for more than 15 years, and water absorption tests performed on 50 water-cooled generator stator windings during a five-year planned preventive maintenance period beginning in 2006 identified water absorption problems in 10 of them, all of which required repair. Because the existing water absorption test detects this problem by utilizing stochastic methods after measuring the capacitances at the final positions of insulation breakdown, its accuracy is limited. This study demonstrates that water absorption can be more accurately diagnosed by utilizing method along with a more precise one.

열전소자를 이용한 고온용 로봇 그리퍼 냉각장치에 관한 연구 (Study of the robot gripper cooling device for a high temperature material using peltier element)

  • 신기수;홍성덕;김근수;권순재
    • 한국산업융합학회 논문집
    • /
    • 제18권1호
    • /
    • pp.37-44
    • /
    • 2015
  • In the research, we developed a device for cooling the drive section of the gripper of a robot for handling the high temperature material. In this study, By using a Peltier element, the high-temperature material is not affected and driving cylinder is cooled to prevent damage due to high temperatures. Hot part of the Peltier element is towards the robot gripper. Cool part of the Peltier element is towards the driving cylinder. The heat sink portion is made to keep the cooling effect. As the performance result, cooling-test is taken, and their result is satisfy.

음향방출과 SFC 시험법에 의한 금속복합재료의 기지재 열처리 효과에 따른 미시적 변형기구 특성 평가 (Evaluation of Microscopic Deformation Behaviors of Metal Matrix Composite due to Heat Treatment by means of SFC Test and Acoustic Emission)

  • 강문필;이준현
    • 비파괴검사학회지
    • /
    • 제20권5호
    • /
    • pp.381-389
    • /
    • 2000
  • 금속기지 복합재료의 미시적 파손기구는 작용하중의 방향, 재료의 열처리 상태, 기지재 및 강화재의 특성, 섬유체적률 등 여러 인자의 영향을 받는다. 이중 특히 재료의 열처리는 금속기지 복합재료의 기계적 특성을 지배하는 주요한 인자인 강화섬유와 기지재 사이의 계면특성에 큰 영향을 준다. 강화섬유와 기지재는 매우 큰 열팽창계수 차이를 가지기 때문에 금속기지 복합재료의 제조과정에 있어서 급격한 온도강하가 있을 경우에는 강화섬유와 기지재 사이의 계면에서는 잔류응력이 형성되며 이 때 발생한 잔류응력은 금속복합재료의 파손기구는 물론 기지재와 강화섬유 사이의 계면전단강도에도 중대한 영향을 미칠 수도 있다. 따라서 금속복합재료에 있어서 기지재와 강화재 사이의 계면전단강도에 대한 잔류응력의 영향을 평가하는 것은 금속복합재료의 실질적인 응용측면에서는 매우 중요한 과제라 할 수 있다. 복합재료에 있어서의 음향방출 기법과 SFC시험법을 동시에 이용하면 기지재와 강화재의 균열 및 기지재와 강화재 사이의 계면분리현상에 의한 미시적 파손기구를 명확하게 분리, 관찰할 수 있는 크나큰 이점이 있다. 따라서 된 연구에서는 음향방출기법과 SFC시험법을 이용하여 금속복합재료의 열처리 효과에 따른 미시적 파손기구 및 계면전판강도 변화특성을 체계적으로 연구, 고찰하였다.

  • PDF

사상체질에 따른 과체중 및 비만 환자의 소증(素證) 특성 비교 (Study on the Characteristics of Ordinary Symptoms in Overweight and Obesity Patients according to Sasang Constitution)

  • 신승원;이준희
    • 한방비만학회지
    • /
    • 제13권1호
    • /
    • pp.33-45
    • /
    • 2013
  • Objectives: This study was aimed to find out the characteristics of ordinary symptoms between the control and patient groups, diagnosed as overweight or obesity, in Soyang, Taeeum, and Soeum Constitutions and among those 3 groups. Methods: As a prospective cross-sectional study based on medical records, 9213 patients, who visited Kyung Hee University Medical Center from May in 2007 to June in 2010, were included. To diagnose the constitution, Revised Questionnaire for the Sasang Constitution Classification II and examinations by oriental medical doctors who majored in Sasang Constitution Medicine were performed. Based on the World Health Organization criteria for Asian obesity assessment, body mass index (BMI) was classified into 3 groups; more than 25 as obesity, 23 to 25 as overweight, and less than 23 as normal. Ordinary symptoms questionnaire, which consists of 46 questions in 8 categories, were given to the subjects. One-way ANOVA test in continuous variables and chi-square test in categorical variables were carried out to analyze statistical significance. Results and Conclusions: 1) In general characteristics, we could find out the significant differences in age, sex, height, weight, BMI, waist circumference, blood pressure, total cholesterol, triglyceride, low density lipoprotein cholesterol, high density lipoprotein cholesterol, fasting blood sugar, and hemoglobin A1c among the 3 Constitutional groups. 2) Soyang Constitution of overweight and obesity has tendency to have higher appetite, like cool or cold water, defecate more, swear more, dislike heat, and have warmer or hotter extremities in the ordinary symptoms, compared with the control group. 3) Taeeum Constitution of overweight and obesity has tendency to have higher appetite, like cool or cold water, defecate more, swear more, dislike heat, and have warmer or hotter extremities in the ordinary symptoms, compared with the control group. 4) Soeum Constitution of overweight and obesity has tendency to have higher appetite and less fatigue in the ordinary symptoms, compared with the control group. 5) Soeum Constitution showed the slightest increase in appetite, preference about room temperature water, less number of feces, and feeling of chill and warmer extremities in ordinary symptoms, compared with Soyang and Taeeum Constitutions. Taeeum Constitution showed the distinct increase in appetite and sweating in ordinary symptoms, compared with Soyang and Soeum Constitutions.