• Title/Summary/Keyword: Heat-care

Search Result 158, Processing Time 0.024 seconds

Analysis of Heat Treatment Process for Large Forgings Considering Phase Transformation (대형 단조품 담금질 과정의 조직 및 응력분포 해석)

  • 이정호;이부윤;전제영;이명렬;조종래
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1996.11a
    • /
    • pp.964-968
    • /
    • 1996
  • The demands of size and quality of large steel shaft forgings for ship building, power plant, steel plant, etc. are rapidly increasing, and some of these productions are manufactured from ingot weighing more than 300 tons. For use as rotating components. shafts require toughness, strength and homogeneity, and therefore are produced through a variety of heat treatments. According to the increase of ingot size, micro- and macrosegregation and also mass effect of the product increase. Thus, special care should be paid to the heat treatment of such large shaft forgings. In this paper, the heat treatment of large shaft forgings such as rotor and back-up roll is calculated using the commercial finite element code SYSWELD. Calculated distributions of temperature and phase are compared with experimental data. The continuous cooling transformation diagram, thermal and mechanical properites of each phase are used. The phase proportion, hardness and residual stress during water quenching are discussed.

  • PDF

Effect of 41℃ deep heat formed by vacuum heating on various pain: Dr.Pakk (Dr. 팍) for pain care

  • Chang, Tae-soun
    • CELLMED
    • /
    • v.12 no.4
    • /
    • pp.16.1-16.2
    • /
    • 2022
  • Treatment of patients with pain is directed at relieving pain and restoring function. Heat therapy has been used as a pain treatment. The mean temperatures were 40 and 41℃. Our device, Dr.Pakk heats special silicone to 41℃ with far-infrared rays and attaches it to the painful knee using a vacuum to show the effect. The core technology of the Dr.Pakk is that deep heat is generated when the heat is transmitted deeply by attaching it to the skin. In our experience, Dr.Pakk can be especially effective for knee pain.

Health-care Application Utilizing GPS of Smartphone (스마트폰의 GPS 기능을 활용한 건강관리 어플리케이션)

  • Chun, Nagyeom;Hwang, Joungwon;Son, Jeongil;Hwang, Soyoung
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2016.05a
    • /
    • pp.227-229
    • /
    • 2016
  • 최근 현대인들의 성인 고도 비만의 비율이 증가함에 따라 건강에 대한 관심이 높아지고 있다. 이러한 추세에 발 맞춰 본 논문에서는 건강과 GPS 위치정보를 접목시켜 사용자들에게 보다 효율적인 운동을 할 수 있는 건강관리 어플리케이션을 제안한다. 구현한 어플리케이션은 스마트폰에서 테스트하여 성능 평가하였다.

  • PDF

Tracheobronchial Polyps Following Thermal Inhalation Injury

  • Shin, Beomsu;Kim, Mikyeong;Yoo, Hongseok;Kim, Se Jin;Lee, Ji Eun;Jeon, Kyeongman
    • Tuberculosis and Respiratory Diseases
    • /
    • v.76 no.5
    • /
    • pp.237-239
    • /
    • 2014
  • The early pulmonary consequences of inhalation injury are well documented; however, little is known about delayed pulmonary complications following thermal inhalation injury. Although thermal injury below the vocal cords is rare because of effective heat dissipation in the upper airway, inflammatory endobronchial polyps have previously been reported as a delayed complication associated with inhalation injury. We report an extraordinary case of tracheobronchial polyps in patients with smoke inhalation injury. This report shows the delayed development and natural course of tracheobronchial polyps following thermal injury.

An Analysis on Nursing Activity in Oriental Hospital (한방근무 간호사의 업무분석)

  • Kang, Hyun Sook;Cho, Kyoul Ja;Kim, Kwang Joo;Kim, Kwuy Bun;Cho, Mi Young;Suh, Yeon Ok;Shin, Hye Sook;Jeon, Eun Young;Chung, Sook Ja;Lee, Hei Jin
    • The Korean Nurse
    • /
    • v.33 no.5
    • /
    • pp.63-75
    • /
    • 1995
  • The need of oriental nursing role is recently increasing. The implication of this trend is enormous not only for the need of independent of independent oriental nursing intervention. Hence, this study was designed to describe the characteristics of oriental nursing activity and identify the meaning of nursing activity in oriental hospital. A total of 24 nurses were selected by convenience sampling from eight units at one oriental hospital. A total of 168 data were collected using minute-by-minute recording during nurse s work shift. The data were analyzed using nova and scheffe method as post-hoc test The results of this study are as follows; 1. the category of nursing activity in oriental hospital 74.4% of nursing activity was the patient-oriented nursing care. The nursing activity included others (18.28%), the function-oriented nursing care (7.07%), and staff-oriented care (0.2%). 29.1 % of the patient-oriented nursing care was the direct care, and 24. 5 % of the patient-oriented nursing care was the indirect care. There was a lack of patient education and the communication patient. 2. Nursing activity in oriental hospital by characteristics 1) Nursing activity by unit For patient-oriented nursing care, there was a statistically significant difference among 8 units. In the critical care unit, the patient-oriented nursing care was mostly performed. For function-oriented nursing care, there was statistically significant difference among 8 units. In the physical therapy unit, the function-oriented nursing care was mostly performed. 2) Nursing activity in oriental hospital For all kinds of nursing activity, there was a statistically significant difference between shifts. In night shift patient-oriented nursing care, function-oriented nursing care, and other kinds of nursing care was mostly performed. Patient-oriented nursing care included indirect care, treatment set management, and the breaktime. In day shift, staff-oriented nursing care was performed. 3) Nursing activity in oriental hospital For all kinds of nursing activity, there was not a statistically significant difference by day. The day has not impact on nursing activity. 3. the meaning of activity in oriental hospital The results of this study show that the patient-oriented care was vital check, input! output check, medication, bedsore prevention, nasogastric feeding, oral care, catheterization care, perinatal care, nursing care associated with acupuncture and moxacautery, observation (fever, sweating), heat and cold application communication with patent and family, and patient room management In conclusion, two issues associated with the findings of the research appeated to be involved in the difficulty of nursing activity in hospital. The first issue was the nursing care in oriental hospital provided by nurses who have a limited understading of the principles of oriental medicine. The second issue was the deficiency of systematic guideling for oriental nursing activity. The findings suggest the need to develop the systematic guideline for oriental nursing activity. The need of continuing education for nurses who work in the oriental hospital, and the need of nursing education including oriental nursing are critical.

  • PDF

Microbiological Quality Evaluation for Implementation of a HACCP System in Day-Care Center Foodservice Operations II. Focus on Non-Heating Process (보육시설급식소의 HACCP시스템 적용을 위한 미생물적 품질평가 II. 비가열조리 공정을 중심으로)

  • 민지혜;이연경
    • Journal of Nutrition and Health
    • /
    • v.37 no.8
    • /
    • pp.722-731
    • /
    • 2004
  • The objective of this study was to evaluate the microbiological quality of non-heat-processed foods for implementation of a HACCP (Hazard Analysis and Critical Control Point) system in day-care center foodservice operations. The evaluating points were microbial assessment of foods, utensils, and employee's hands during preparation, cooking, and serving. The temperature of non-heated food being served was also measured. Microbiological quality was assessed using 3 M Petrifilm/syp TM/ to measure total plate count and coliforms for food and utensils and Staphylococcus aureus for hands in five Gumi day-care centers. Results showed low microbiological quality of non-heated foods. This was probably due to contaminated raw ingredients and cross-contamination that occurred during preparation and cooking (e.g., unsatisfactory washing and disinfection of raw materials and utensils). These results suggest that it is essential to educate employees on good personal hygiene (hand washing) , prevention of cross-contamination through use of properly washed and sanitized utensils, and proper washing and disinfection of raw vegetables. Establishing Sanitation Standard Operating Procedures (SSOPs) are an essential part of any RACCP system in day-care center foodservice operations.

A Study on the Performance of HCFC22 and Alternative Refrigerants in Heat Pumps (열펌프를 이용한 R22대체 혼합냉매의 성능에 관한 연구)

  • Song, Y.J.;Jung, D.G.
    • Solar Energy
    • /
    • v.18 no.1
    • /
    • pp.69-79
    • /
    • 1998
  • This paper is concerned about the performance of HCFC22 alternative refrigerants used in heat pumps and industrial chillers. A water-to-water breadboard heat pump with counter-current heat exchangers and a hermetic compressor was built to carry out the experiments with various refrigerants. For each test, more than 40 temperatures, 4 pressures, power input, mass flow rates of the heat transfer fluids were measured. Refrigerants tested were HCFC22, R290(Propane), an azeotrope of 45%Propane/55%R134a mixture, and a nonazeotropic mixture of Calor 50. All tests were conducted under ARI test A condition. It is found that the COP and capacity of propane were 18% and 2.5% higher than those of HCFC22 while the COP and capacity of 45%Propane/55%R134a mixture were 3.5% and 5.3% higher than those of HCFC22 respectively. Also the COP and capacity of Calor 50 were 17% and 7.8% higher than those of HCFC22. Compressor discharge temperatures of alternative refrigerants were roughly $35^{\circ}C$ lower than that of HCFC22 indicating that these refrigerants are good from the view point of compressor reliability. The charging amounts for the alternative refrigerants were reduced by 40-60% as compared to that of HCFC22. Overall, it can be said that hydrocarbon containing alternative refrigerants are excellent in thermodynamic performance but should be used with considerable care due to their flammability.

  • PDF

An Experimental Study on Hydration Heat and Strength Properties Concrete with High Volume Fly-Ash (플라이애시 콘크리트의 수화발열 특성과 압축강도 특성에 관한 실험적 연구)

  • 김우상;김광기;백민수;김우재;정재영;정상진
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2003.05a
    • /
    • pp.67-71
    • /
    • 2003
  • This study is for the great quantity use of fly-ash. For the producing of high volume concrete from the use of fly-ash, the method of replacement between bonding agents and fine aggregate by fly-ash at the same time was used. It was used that the adiabatic temperature rise of concrete about the mass member which bad been produced by the method that was mentioned before, and the hydration heat of the core test pieces in concrete was measured. Also the core test pieces which were replaced with fly-ash was studied by the compressive streneth's comparison between standard care test pieces and core test pieces. In the case of mass test pieces, hydration heat and the tine to reach the highest temperature were decreased by an increase in replaced fly-ash's amounts of concrete. In addition, among the test pieces having the same amounts of concrete, the test pieces having more replaced amounts of fly-ash's fine aggregate showed higher hydration heat and the increased time to reach the highest temperature. Compressive strength was also increased by hydration heat's decrease according to fly-ash replacement. Replacement of fly-ash was more effective in high temperature environment.

  • PDF

Performance evaluation of R22 alternative refrigerants (R22 대체냉매의 성능 평가)

  • 송용재;박봉진;정동수;김종보
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.10 no.3
    • /
    • pp.292-302
    • /
    • 1998
  • In this study, 14 refrigerant mixtures composed of R32, R125, R134a, R143a, R152a, and R1270(Propylene) were tested in a breadboard heat pump in an attempt to replace R22 used in most of the residential air conditioners and heat pumps. The heat pump was of 1 ton capacity and water was employed as the secondary heat transfer fluids. All tests were conducted under ARI test A condition. Ternary mixtures composed of R32, R125, and R134a were shown to have 4∼5% higher COP and capacity than R22 and hence they seem to be very promising candidates to replace R22. On the other hand, ternary mixtures containing R125, R134a, and R152a have lower COP and capacity than R22. R32/R134a binary mixtures show a 7% increase in COP and have the similar capacity to that of R22 and hence they are also good candidates to replace R22. Special care must be exercised when a suction line heat exchanger is used with these mixtures in air conditioners. Finally, the compressor discharge temperatures of all mixtures tested were lower than those of R22 by 15.g∼34.7t, which indicates that these mixtures would offer better system reliability and longer life time than R22.

  • PDF

A Study on Hydration Heat Properties and Strength Properties of High Volume Fly-Ash Concrete (플라이애시를 대량 사용한 콘크리트의 수화열특성 및 강도특성에 관한 연구)

  • Paik, Min-Su;Lee, Young-Do;Jung, Sang-Jin
    • Journal of the Korea Institute of Building Construction
    • /
    • v.3 no.3
    • /
    • pp.135-142
    • /
    • 2003
  • This study is for the great quantity use of fly-ash. For the producing of high volume concrete from the use of fly-ash, the method of replacement between bonding agents and fine aggregate by fly-ash was used at the same time. It was used that the adiabatic temperature rise of concrete about the mass member which had been produced by the method that was mentioned before, and the hydration heat of the core test pieces in concrete was measured. Also the core test pieces which were replaced with fly-ash was studied by the compressive strength's comparison between standard care test pieces and core test pieces. In the case of mass test pieces, hydration heat and the time to reach the highest temperature were decreased by an increase in replaced fly-ash's amounts of concrete. In addition, among the test pieces having the same amounts of concrete, the test pieces having more replaced amounts of fly-ash's fine aggregate showed higher hydration heat and the increased time to reach the highest temperature. Compressive strength was also increased by hydration heat's decrease according to fly-ash replacement. Replacement of fly-ash was more effective in high temperature environment.