• Title/Summary/Keyword: Heat-Pipe

Search Result 1,194, Processing Time 0.023 seconds

Heat Transfer Characteristics of the U-shape Heat Pipe using Working Fluid of PFC (PFC 작동유체 사용 U형 히트파이프의 열전달특성 연구)

  • 이기우;박기호;전원표
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.8
    • /
    • pp.796-802
    • /
    • 2001
  • The purpose of the present study is to examine the heat transfer characteristics of the U-shape heat pipe for the cooling of semiconductor in subway train. Perflouro-carbon(PFC) was used as working fluid. Temperature distribution on the surface and heat transfer coefficients were investigated according to the working fluid volume percent and heating rate. The results were as follows; Optimum volumetric percent of working fluid was from 80% to 90%, and hat transfer coefficients of evaporation and condensation were as follows, respectively. $\hbar_ie=0.37\times(\frac{P_i}{P_O})$l_c}^0.3$,$\hbar_ic-4.2(\frac{\kappa_l^3p_l^2gh_fg}{\mu_lq_c_l_c}^\frac{1}{3}

  • PDF

Study on Simulation of Cooling Water through Concentric Double Pipe Heat Exchanger (Concentric Double Pipe 열교환기에서 냉각수 급랭 현상의 모사에 대한 연구)

  • ANCHEOL CHOI;SEONGWOO LEE;IK HO SHIN;SUNGWOONG CHOI
    • Journal of Hydrogen and New Energy
    • /
    • v.34 no.6
    • /
    • pp.741-747
    • /
    • 2023
  • In this study, the heat transfer characteristics were numerically analyzed to investigate the possibility of utilizing cooling water using liquid nitrogen. From the study, as the mass flow rate of the hot fluid increased, the heat transfer rate increased by 8.9-81.7%. And lowering the inlet temperature of the hot fluid resulted in increase in the heat transfer rate by 33.8-71.5%. As for the filling level of liquid nitrogen, as higher filling level led to a decrease in the outlet temperature and an increase in the overall heat transfer coefficient.

Application of a Large Scale Heat Pipe System to Preheating the Fuel Gas of Low Heating Value (분리형 히트파이프의 저발열량 연료가스 예열시스템에 대한 적용연구)

  • Park, Heung Soo;Riu, Kap Jong;Lee, Jin Ho;Lee, Yong Kuk
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.23 no.9
    • /
    • pp.1085-1097
    • /
    • 1999
  • A separate heat pipe system capacity of 3,700kW has been developed and applied to preheating the blast furnace gas for recovery of the waste heat from boiler. The system is designed to preheat the blast furnace gas up to $126^{\circ}C$ by using tho boiler exhaust gas of which temperature is $180^{\circ}C{\sim}220^{\circ}C$. The arrangement of the fin tubes as well as the shape of the fin has been carefully determined to minimize the fouling problems. The heat pipe system was found to be stable in circulation of the working fluid and the range of the temperature variation of the preheated blast furnace gas was within $10^{\circ}C$. It was proved through a long-term test that the selected tube arrangement and the shape of the fins are proper to prevent the fouling problems and that the pay-back period of the system Is within one year.

Experimental Study on the Drag Reduction & Heat Transfer Ratio in the Circular Pipe with Swirl Generater (난류발생기를 가지는 원형 파이프내에서의 마찰저감 및 열전달율에 관한 실험적 연구)

  • Kim, Seong-Su;Cho, Sung-Hwan;Yoon, Seok-Mann
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.430-435
    • /
    • 2008
  • Total lengths of domestic pipe network for district heating system are above about 2,500Km. A lots of pumping power for heat transportation through long pipe are required by the flow friction of pipe surface. Until now there have been considered about various methods to reduce the flow friction for district heating system such as using surfactants and turbulence promoters by swirl flow and baffles etc. At this study, swirl flow generator was tested about the possibility to increase the heat transfer ratio at the heat exchanger in the case which the suppling water temperature increased from $50^{\circ}C$ until $120^{\circ}C$. Experimental results showed that the heat transfer ratio increased and also pressure increase ratio increased simultaneously in the case which swirl flow generator installed. The amount of the increasing ratio for heat transfer and pressure were reached until 4.33% and 11% at the case of $120^{\circ}C$ suppling temperature which domestic district heating system were using.

  • PDF

Analysis of Heat Emission from Hot Water Pipe for Greenhouse Heating System Design (온실 난방시스템 설계를 위한 온수난방배관의 방열량 분석)

  • Shin, Hyun-Ho;Nam, Sang-Woon
    • Journal of Bio-Environment Control
    • /
    • v.28 no.3
    • /
    • pp.204-211
    • /
    • 2019
  • The purpose of this study is to provide basic data for setting environmental design standards for domestic greenhouses. We conducted experiments on thermal environment measurement at two commercial greenhouses where hot water heating system is adopted. We analyzed heat transfer characteristics of hot water heating pipes and heat emission per unit length of heating pipes was presented. The average air temperature in two greenhouses was controlled to $16.3^{\circ}C$ and $14.6^{\circ}C$ during the experiment, respectively. The average water temperature in heating pipes was $52.3^{\circ}C$ and $45.0^{\circ}C$, respectively. Experimental results showed that natural convection heat transfer coefficient of heating pipe surface was in the range of $5.71{\sim}7.49W/m^2^{\circ}C$. When the flow rate in heating pipe was 0.5m/s or more, temperature difference between hot water and pipe surface was not large. Based on this, overall heat transfer coefficient of heating pipe was derived as form of laminar natural convection heat transfer coefficient in the horizontal cylinder. By modifying the equation of overall heat transfer coefficient, a formula for calculating the heat emission per unit length of hot water heating pipe was developed, which uses pipe size and temperature difference between hot water and indoor air as input variables. The results of this study were compared with domestic and foreign data, and it was found to be closest to JGHA data. The data of NAAS, BALLS and ASHRAE were judged to be too large. Therefore, in order to set up environmental design standards for domestic greenhouses, it is necessary to fully examine those data through further experiments.

Heat Transfer Experiment and Analysis to Predict the Efficiency of Heat Exchanger for Deep Geothermal System (심부지열 용 동축 열교환기 성능예측을 위한 열전달 실험 및 해석)

  • Jung, Kuk-Jin;Jeong, Yoon-Seong;Park, Jun Su;Lee, Dong Hyun
    • Journal of Institute of Convergence Technology
    • /
    • v.7 no.1
    • /
    • pp.1-6
    • /
    • 2017
  • The Heat exchanger for deep geothermal system is very important to enhance the efficiency of the system. The co-axial heat exchanger is used due to the limitation of digging space. The heat transfer on the external surface of outer pipe should be high to receive a large amount of heat from the ground. However, the inner pipe should be insulated to reduce the heat loss and increase the temperature of discharge water. This study made experiment apparatus to describe the co-axial heat exchanger and measure the heat transfer coefficients on the internal and external surface. And the pin-fin was designed and fixed on the internal surface to increase the efficiency of heat exchanger. Finally, we calculated the temperature of discharge water using the heat transfer circuit of co-axial heat exchanger and heat transfer coefficient which from experimental results. The water temperature was reached the ground temperature at -500 m and following the ground temperature. When the water return to the ground surface, the water temperature was decreased due to heat loss. As the pin-fin case, the heat transfer coefficient on the internal surface was decreased by 30% and it mean that the pin-fin help to insulate the inner pipe. However, the discharge water temperature did not change although pin-fin fixed on the inner pipe.

A Study on the Effect of Pipe Cooling in Mass-Concrete (매스콘크리트의 파이프 쿨링 효과)

  • 윤승권;김은경;김래현;신치범
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1995.10a
    • /
    • pp.329-333
    • /
    • 1995
  • The usual methods for the temperature control of mass-concrete structures include the use of low-heat cement, pre-cooling, or pipe-cooling. In order to control the heat of hydration of mass-concrete structures such as massive pier or anchor block, and mat foundation, the pipe cooling method is widely acceptable for pratical use. In this paper, method of analysis using the Finite Element Method was applied to analyze the heat exchange on the field of three dimensional thermal conduction. The result of analysis Well agreed with experimentally measurement data by "KUMATANI". The method of this analysis will be used widely to control the heat of hydration by the pipe cooling in mass-concrete.-concrete.

  • PDF

Modeling of Heat Transfer Equations for Estimation of Temperature Variations Inside the Oil Transport Pipe Line (원유 수송관 내부의 온도 변화 예측 을 위한 열전달 방정식의 모델링)

  • Jin, J.J.;Chung, H.T.;Bae, J.S.;Lee, S.O.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2008.03b
    • /
    • pp.300-303
    • /
    • 2008
  • In the present study, the simple form of the heat transfer equation were suggested to estimate the temperature variation inside the oil pipe in order to determine the thickness of the insulating materials to retain the working oils below the critical temperature. The conservation of the thermal energy at arbitrary time were modeled to one dimensional unsteady equation with the empirical formula or data. The calculating results for non-insulation case showed that the temperature were very sensitive to the thermal convection by the velocity of the external wind. For insulation case, the insulation material which has higher density and specific heat, lower thermal conductivity should be chosen with more brighter coloring outside the pipe in order to retain the working oils below the critical temperature.

  • PDF

A Study on the Condenser Temperature Characteristics of a Disk Type Heat Pipe (원판형 히트파이프의 응축부 온도 특성에 관한 실험적 연구)

  • Boo, Joon-Hong;Chung, Won-Bok;Kim, Tae-Gyu
    • Proceedings of the KSME Conference
    • /
    • 2000.04b
    • /
    • pp.148-153
    • /
    • 2000
  • An experimental study was conducted to investigate an isothermal characteristics of the condenser surface of disk type heat pipe using PF 5060 and FC 40 as working fluids. Desired temperature range at the condenser surface was $90^{\circ}C{\sim}130^{\circ}C$, which was cooled by natural convection. The operating temperature, the height of vapor space, the wall thickness of condenser, and the existence of a wick structure were considered as experimental factors. The temperature difference and the temperature fluctuation at the condenser surface were analysed to describe the performance of the heat pipe.

  • PDF

Heat Transfer Simulation and Temperature Measurement for Heat Input Control in Orbital Welding (오비탈 용접에서 입열량 제어를 위한 열전도 시뮬레이션 및 온도측정)

  • 김기정;김진우;강윤배;조상명
    • Proceedings of the KWS Conference
    • /
    • 2003.05a
    • /
    • pp.155-158
    • /
    • 2003
  • Orbital GTA welding is used in the pressure pipe line of auto-mobile, LNG and plant piping. To weld the pipe line safely, to some extent, the back bead must be formed in the root pass. In the plate welding the back bead can be observed, but in the pipe welding, the back bead can not be observed directly. In the welding around circumference, the parameters such as gravity, surface tension and arc force are different at each position. And then D/B for welding condition at each position are required. We also studied about the setting of the optimum orbital welding condition by controlling heat input.

  • PDF