• 제목/요약/키워드: Heat-Pipe

검색결과 1,188건 처리시간 0.038초

Electronics Cooling Using the Porous Metallic Materials

  • Lucaci, Mariana;Orban, Radu L.;Lungu, Magdalena;Enescu, Elena;Gavriliu, Stefania
    • 한국분말야금학회:학술대회논문집
    • /
    • 한국분말야금학회 2006년도 Extended Abstracts of 2006 POWDER METALLURGY World Congress Part 1
    • /
    • pp.315-316
    • /
    • 2006
  • The paper presents some results regarding the obtaining of some copper heat pipes with a porous copper internal layer for electronic components cooling. The heat pipes were realized by sintering of spherical copper powders of $90{\div}125\;{\mu}m$ size directly on the internal side of a copper pipe of 18 mm in diameter. The obtained pipes were then brazed in order to obtain a heat pipe of 0.5 m in length. After that, the heat pipe was sealed and filled with a small quantity of distilled water as working fluid. To establish the total heat transport coefficient and the thermal flow transferred at the evaporator, some external devices were realized to allow the heating of the evaporator and the cooling of the condenser. Water heat pipes are explored in the intermediate temperature range of 303 up to 500 K. Test data are reported for copper water heat pipe, which was tested under different orientations. The obtained results show that the water heat pipe has a good thermal transfer performance in the temperatures range between 345 and 463 K.

  • PDF

두개의 열원이 부착된 히트파이프의 동작 특성 (Operating characteristics of a heat pipe with two heat sources)

  • 박종흥;노홍구;이재헌
    • 대한기계학회논문집B
    • /
    • 제22권3호
    • /
    • pp.303-315
    • /
    • 1998
  • Numerical and experimental studies on a heat pipe with two heat sources have been performed to investigate the operating characteristics. Numerical analysis was performed based on the cylindrical two-dimensional incompressible laminar flow for the vapor space and the conjugate heat transfer for the entire heat pipe. Experimental study with a 0.45 m length copper-water heat pipe was also performed to validate the numerical modeling for the heat input range from 29 W to 47 W on each heater. As results, the temperature profiles at the outer wall for the single active heat source as well as the temperature profiles for the switching operation between two heat sources are suggested. Due to the axial conduction, it is found that the temperature drop between the evaporator and the condenser appears small when the heat source closer to the condenser is turned on. For the switching operation in the present study, the transient time is about 700s and the temperatures at the locations of both heat source are same in 130s after switching.

A Study on Thermal Performance of Heat Pipe for Optimum Placement of Satellite Equipment

  • Park, Jong-Heung
    • ETRI Journal
    • /
    • 제19권2호
    • /
    • pp.59-70
    • /
    • 1997
  • A study on the operation of a heat pipe with two heat sources has been performed to optimize the heat distribution of satellite equipment. A numerical modeling is used to predict the temperature profile for the heat pipe assuming cylindrical two-dimensional laminar flow for the vapor, and the conduction heat transfer for the wall and wick. An experimental study using the copper-water heat pipe with the length of 0.45 m has been performed to evaluate the numerical model and to compare the temperature distribution at the outer wall for the non-uniform heat distribution. The results on temperature profiles for the heat input range from 29 W to 47 W on each heater are presented. Also the correlation between the heat input and the temperature increase is presented for the optimum distribution on two heaters. The result shows that the outer wall temperature can be controlled by redistribution of heat sources. It is also concluded that the heat source closer to the condenser can carry more heat while maintaining lower temperatures at the outer wall.

  • PDF

내부(內部)에 삼각형(三角形) 핀이 부착(附着)된 회전형(回轉型) 히이트파이프의 전열특성(傳熱特性) (Heat Transfer Characteristics for Internally Triangular finned Rotating Heat Pipes)

  • 권순석;전철호;장영석;서해성
    • 태양에너지
    • /
    • 제9권1호
    • /
    • pp.43-52
    • /
    • 1989
  • Heat transfer rate and heat flux from the condenser with internally triangular fins rotating heat pipe has been numerically studied by finite element method. The results of numerical and P.J. Martos' experimental showed good agreement and it was able to predict to the performance of a rotating heat pipe. By increasing fin half angle or fin height, heat transfer rate from condenser was increased slightly but heat flux was decreased. By increasing condenser radius or r.p.m. of rotating heat pipe, heat transfer rate and heat flux was increased rapidly. Heat transfer rate was rapidly increased with increasing fin numbers in case of few fm numbers but slowly increased at many fin numbers. So the optimum fin numbers were a half of maximum fin numbers which was able to install in the condenser of a rotating heat pipe.

  • PDF

지중 열교환기의 순환수에 의한 열응력 및 열전달 거동 분석 (Analysis of thermal stress and heat transfer due to circulating fluid in ground heat exchanger)

  • 길후정;이강자;이철호;최항석;최효범
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2009년도 세계 도시지반공학 심포지엄
    • /
    • pp.385-395
    • /
    • 2009
  • In this study, a series of numerical analysis has been accomplished on the thermal performance and sectional efficiency of a closed-loop vertical ground heat exchanger (U-loop) in a geothermal heat pump system (GHP) considering the circulating fluid, pipe, grout and soil formation. A finite element analysis program, ABAQUS, was employed to evaluate the temperature distribution on the cross section of the U-loop system involving HDPE pipe/grout/formation and to compare sectional efficiency between the conventional U-loop and a new latticed HDPE pipe system. Especially, the latticed pipe is equipped with a thermal insulation zone in order to reduce thermal interference between the inflow pipe and the outflow pipe. Also, a thermal stress analysis was performed with the aid of ABAQUS. 3-D finite volume analysis program, FLUENT, was adapted to analyze a coupled system between fluid circulation in the pipe and heat transfer and simulate an operating process of the closed-loop vertical ground heat exchanger. In this analysis, the effect of the thermal properties of grout, rate of circulation pump, distance between the inflow pipe and the outflow pipe, and the effectiveness of the latticed HDPE pipe system are taken into account.

  • PDF

중성자 영상법을 이용한 Heat Pipe 내의 이상유동 가시화 (Visualization of 2-Phase Flow at Heat Pipe using Neutron Imaging Technique)

  • 김태주;박수지;김종열;도승우
    • 한국가시화정보학회지
    • /
    • 제14권3호
    • /
    • pp.15-21
    • /
    • 2016
  • The circular and flat heat pipe were experimentally investigated by using neutron imaging technique. This experimental study was performed at the DINGO of OPAL research reactor, Australia. The diameter of the circular heat pipe is 10 mm and the dimension of flat is $10(width){\times}3(thickness)mm2$, respectively. We used the distilled water as a coolant. The coolant distributions and 2-phase flow patterns were measured under heating conditions. Experimental results show that neutron imaging technique is a good tool to visualize the 2-phase flow and phenomena in the heat pipe. The coolant distributions and 2-phase flow patterns depend on installation posture of the heat pipe and volume ratio of the coolant. Finally, it was discussed to calculate the void fraction by neutron imaging technique.

변압기용 절연유의 특성에 관한 실험적 연구 (A study on an experimental basis a special character of insulating oil the use of a transformers)

  • 김성대;박일수
    • 한국산학기술학회논문지
    • /
    • 제12권11호
    • /
    • pp.5188-5193
    • /
    • 2011
  • 본 연구는 변압기 내부에 있는 절연유의 온도제어를 목적으로 열전소자인 펠티어 소자와 무전력 냉각장치인 Heat pipe를 이용한 다양한 시스템을 설계 제작하여, 절연유의 용량별 온도제어에 적용함으로써 최적의 시스템을 구현할 수 있었다. 실험을 통하여 $60^{\circ}C$ 이내의 상태에서는 Heat pipe 100 W + 펠티어 100 W의 조합형이 순수 Heat pipe 300 W보다 탁월한 성능을 확인할 수 있었다. 이를 통하여 조합형의 적정설계 방식이 우수하다는 것을 증명하고, 조합형을 사용함으로써 전기절약 효과와 수배전반의 보다 더 효율적인 관리에 기여하고자 한다.

소결윅의 구조적 특성에 따른 히트파이프의 열수송 한계 분석 (Analysis of Heat Transport Limitations of the Heat Pipe for Structural Characteristics of Sintered Metal Wick)

  • 김근배;김유
    • 한국항공우주학회지
    • /
    • 제33권9호
    • /
    • pp.97-103
    • /
    • 2005
  • 본 연구에서는 소형 동-소결윅 히트파이프를 대상으로 소결윅의 구조적 인자들이 히트파이프의 열수송 한계에 미치는 영향을 이론적으로 분석하였다. 소결윅의 입자 크기의 균일성과 소결 조건이 전체적인 기공분포와 기공률을 포함한 물리적 특성에 지배적인 요소로 작용했으며, 윅 두께 및 기공의 작은 편차가 히트파이프의 열수송 한계에 대체로 큰 영향을 미치는 것으로 나타났다. 특히, 증기온도와 경사각에 따라서 윅 두께와 평균 입자 반경, 그리고 모세관반경의 미세한 변화가 히트파이프의 모세관한계를 현저하게 변화시켰다.

단순 열전달 모델을 이용한 히트파이프의 열전달 성능특성에 관한 연구 (Heat transfer characteristics of the heat pipe using simplified heat transfer model)

  • 서재형;방유마;서이수;이무연
    • 한국산학기술학회논문지
    • /
    • 제16권1호
    • /
    • pp.15-20
    • /
    • 2015
  • 본 연구의 목적은 전기동력 자동차의 전기-전자 장비들을 효과적으로 냉각시키면서 자체적으로 에너지 소비를 최소화 시킬 수 있는 노력의 일환으로, 단순 열전달 모델을 이용하여 윅이 있는 히트파이프의 열전달 및 유동 특성을 고찰하는 것이다. 이를 위하여 히트파이프는 COMSOL프로그램을 이용하여 해석하였고, 작동유체로 물을 이용하였다. 또한, 히트파이프의 속도 및 온도 특성을 히프파이프 길이에 따라 해석하였고, 국소 및 평균 Nu수를 계산하였다. 결과적으로, 히트파이프의 관성력은 가열면과 냉각면의 온도차에 의하여 발생하였다. 히트파이프내 열전달은 가열면에서 냉각면으로 발생하고 히트파이프 중앙으로 갈수록 증가하였다. 더불어, 가열면의 Nu수는 최대 4.47로 나타났으며, 평균 Nu수는 1.88이고, 냉각면의 Nu수는 최대 0.7로 나타났으며, 평균 Nu수는 0.1이다.

매입형 히트파이프의 재질 및 규격변화에 따른 수화열 분산 효과 (Dispertion Effect of Hydration Heat due to Materials and Standard Variation of Embedded Heat Pipe)

  • 김명식;염치선;백동일
    • 한국해양공학회지
    • /
    • 제23권6호
    • /
    • pp.111-116
    • /
    • 2009
  • The cracking due to hydration heat in mass concrete must be resolved to improve the stability and durability of concrete structures. In this study, the economic efficiency was improved by replacing a copper pipe with a steel one for the heat pipe, and the heat pipe was standardized to significantly improve the operation efficiency, such as the processing, transport, assembly, and construction time. As a result of the experiment, the peak temperature of the ICSHP, ISSHP, and ISUHP specimens decreased by about $7.2{\sim}10.9^{\circ}C$ compared to the OPC specimen and the probability of a thermal crack being generated in the ICSHP, ISSHP, and ISUHP specimens decreased by up to 84~88%.