• 제목/요약/키워드: Heat waves

검색결과 287건 처리시간 0.027초

Development of Heat Absorbing and High Electromagnetic Shielding Pre-Painted Steel Sheet

  • Hosokawa, Tomoaki;Ueda, Kohei;Yuasa, Kensei;Nakazawa, Makoto
    • Corrosion Science and Technology
    • /
    • 제9권4호
    • /
    • pp.153-158
    • /
    • 2010
  • Electrical appliances such as audiovisual equipment and personal computers have recently had heat and electromagnetic problems. In order to solve those problems, 'High heat absorbing pre-painted steel sheet (hereinafter referred to as PSS)', 'High electromagnetic shielding PSS' and 'High heat absorbing and high electromagnetic shielding PSS' have been developed. In this paper, the heat characteristics and electromagnetic shielding properties of PSS are investigated by methods that use enclosures and their mechanisms are discussed. It was found that 'High heat absorbing PSS' and 'High heat absorbing and high electromagnetic shielding PSS'could reduce the heat problem. The mechanism of the heat characteristics was presumed for the high heat absorptivity of the back coating inside the enclosure. And it was also found that 'High electromagnetic shielding PSS' and 'High heat absorbing and high electromagnetic shielding PSS' could shield electromagnetic waves well. The mechanism of the electromagnetic shielding properties was considered for the low transfer impedance of the back coating inside the enclosure. 'High heat absorbing PSS' and 'High electromagnetic shielding PSS' have been adopted as materials for electrical appliances and 'High electromagnetic shielding and high heat absorbing PSS' have been tested for that purpose.

폭염 대응전략 수립을 위한 폭염위험도 시각화 플랫폼 (The Hazard Viz-platform for the Establishment of Heatwave Response Strategies)

  • 김미연
    • 한국멀티미디어학회논문지
    • /
    • 제23권5호
    • /
    • pp.683-699
    • /
    • 2020
  • Recently, the earth's highest temperature is rising due to severe climate change and heat wave. In addition, due to the increase of elderly population over 65, the number of heat patients is also increasing. In particular, the elderly who live alone in poor living environments, the lower income group, and the socially disadvantaged, such as children and pregnant women, are exposed to the dangers of heat waves, so the government's practical measures are urgently needed. In this study, we will build a visualization platform for each level of heat wave and provide the necessary countermeasure solution according to the heat wave risk. "The Hazard Visualization Platform for Heatwave" provide not only simple information, but also a customized safety service for citizens to prevent heatwaves, respond to heatwaves, and utilize heat wave information.

칠발도 Buoy자료를 이용한 해양-대기 열교환량 산출 및 파랑 특성에 관한 연구 (A Study on the Estimation of Air-Sea Heat Fluxes and the Wave Characteristics using Chilbaldo Buoy Data)

  • 윤용훈;홍성길;홍윤;이지연
    • 한국해양학회지:바다
    • /
    • 제3권1호
    • /
    • pp.9-15
    • /
    • 1998
  • 기상청에서는 1996년 7월부터 1997년 2월까지 목포앞바다의 칠발도 인접 해역에 1시간 간격으로 해양기상을 관측할 수 있는 부이를 설치하고 자료를 얻었다. 이 자료로부터 이 해역의 1일 평균 해양-대기 열교환량을 산출하고, 해양기상 상태의 특성을 조사하였다. 현열속의 경우, 7월에 최소(평균 -5.5 $Wm^{-2}$)이고, 1월에 최대(평균 12.6 $Wm^{-2}$)를 나타내고 있는데 이는 여름철에 대기가 해양으로 열을 공급하고 겨울철에는 반대로 해양에서 대기로 열을 공급하지만 그 크기는 여름철이 겨울철에 비해 작다는 것을 의미한다. 잠열속의 경우 7월에 최소(평균 -4.6 $Wm^{-2}$)를 보이고, 최대값은 11월에 월 평균 86.5 $Wm^{-2}$이고 10월에 일평균 최대값이 250$Wm^{-2}$까지 나타났다. 잠열 속은 대기가 건조해지고 바람이 강해지는 가을철에 최대가 나타나서 겨울철까지 지속된다. 파랑분석에 의하면 바람이 강한 겨울철이 여름철에 비해 높은 파의 출현율이 많았다 파주기는 4~6초의 출현율이 가장 많았고, 파향은 계절풍의 영향으로 겨울에는 북 또는 북동방향에서 유입되는 파가 우세하고, 여름에는 남, 남서 또는 서쪽에서 유입되는 파가 비교적 자주 출현하였다.

  • PDF

HEATING OF SUNSPOT CHROMOSPHERES BY SLOW-MODE ACOUSTIC SHOCK WAVES

  • Lee, Myung-Gyoon;Yun, Hong-Sik
    • 천문학회지
    • /
    • 제18권1호
    • /
    • pp.15-31
    • /
    • 1985
  • Making use of the arbitrary shock theory developed by Ulmschneider (1967, 1971) and Ulmschneider and Kalkofen (1978), we have calculated the dissipation rates of upward-travelling slow-mode acoustic shock waves in umbral chromospheres for two umbral chromosphere models, a plateau model by Avrett (1981) and a gradient model by Yun and Beebe (1984). The computed shock dissipation rates are compared with the radiative cooling rate given by Avrett (1981). The results show that the slow-mode acoustic shock waves with a period of about 20 second can heat the low umbral chromospheres travelling with a mechanical energy flux of $2.6{\times}10^6\;erg/cm^2s$ at a height of $300{\sim}400km$ above the temperature minimum region.

  • PDF

Photo-thermo-elastic interaction in a semiconductor material with two relaxation times by a focused laser beam

  • Jahangir, A.;Tanvir, F.;Zenkour, A.M.
    • Advances in aircraft and spacecraft science
    • /
    • 제7권1호
    • /
    • pp.41-52
    • /
    • 2020
  • The effect of relaxation times is studied on plane waves propagating through semiconductor half-space medium by using the eigen value approach. The bounding surface of the half-space is subjected to a heat flux with an exponentially decaying pulse and taken to be traction free. Solution of the field variables are obtained in the form of series for a general semiconductor medium. For numerical values, Silicon is considered as a semiconducting material. The results are represented graphically to assess the influences of the thermal relaxations times on the plasma, thermal, and elastic waves.

Influence of variable thermal conductivity on waves propagating through thermo-elastic medium

  • Abo-Dahab, Sayed M.;Jahangir, Adnan;Dar, Adiya
    • Structural Engineering and Mechanics
    • /
    • 제82권4호
    • /
    • pp.459-467
    • /
    • 2022
  • We investigated the influence of variable thermal conductivity on waves propagating through the elastic medium. Infinitesimal deformation results in generation of thermal signal, and is analyzed by using dual phase lag heat (DPL) conduction model. The medium considered is homogenous, isotropic and bounded by thermal shock. The elastic waves propagating through the medium are considered to be harmonic in nature, and expressions for the physical variables are obtained accordingly. Analytically, we obtained the expressions for displacement components, temperature, micro-temperature component and stresses. The theoretical results obtained are computed graphically for the particular medium by using MATLAB.

한파로 인한 초기 동해를 입은 콘크리트의 염해 저항성 평가 (Evaluation of Chloride Penetration Resistance of Frost Concrete according to the water-cement ratio, during the Cold Wave)

  • 박동천;이준해
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2020년도 가을 학술논문 발표대회
    • /
    • pp.165-166
    • /
    • 2020
  • The climate on the Korean Peninsula has been warmed recently, abnormal weather conditions such as heat waves, cold waves, and tropical nights have been detected frequently. Precisely, the number of days with cold waves in the winter has increased, and rapid changes of temperature in the morning and afternoon have occurred frequently in the 2000s. Due to the previous phenomenons, this research is focused on evaluating the concrete's Chloride Penetration Resistance and Durability, and the difference of the resistance according to the W/C.

  • PDF

한반도 내륙 지역의 기후 변화 대응을 위한 극한기후 분석 및 적응 방안 연구 - 대구 광역시 사례를 중심으로 - (Extreme Climate Analysis and Adaptation Research on the Response of Climate Change in the Inland Region of the Korean Peninsula - Case of Deagu Metropolitan Area -)

  • ;김해동;김은지;이순환
    • 한국환경과학회지
    • /
    • 제29권7호
    • /
    • pp.773-784
    • /
    • 2020
  • In order to protect the lives and property of citizens, the central and local governments are responding by enacting municipal ordinances and regulations as the frequency of extreme weather conditions due to climate change increases and intensity increases gradually. Accordingly, the basic contents and strategies of domestic and foreign policies to cope with cold and heat waves were reviewed, referring to measures suitable for application to the Daegu metropolitan area. In addition, it is intended to provide a policy alternative to Daegu metropolitan area to minimize damage from extreme weather by identifying the current status, characteristics, and future prospects of extreme weather in Daegu metropolitan area. Since the damage caused by the cold wave in Daegu area is not as great as that of other regions, it is urgent to come up with cold wave measures for the health and transportation sectors, and to come up with measures against the heat wave as the damage caused by the heat wave is the most serious in the country. Also we will identify spatial characteristics so that the districts and counties with high vulnerability to extreme weather can be identified and implemented first, and present civic life-oriented facilities and civic action guidelines to overcome cold and heat waves.

일 최저 기온을 이용한 한국의 폭염사상 추세 (Trend of heat wave events in South Korea using daily minimum air temperature)

  • 김령은;원정은;이정민;최정현;김상단
    • 한국습지학회지
    • /
    • 제21권4호
    • /
    • pp.344-353
    • /
    • 2019
  • 폭염은 전 세계에서 나타나고 있는 현상으로 열 노출과 관련된 위험을 악화시키고, 치명적인 인명피해를 초래한다. 본 연구에서는 폭염의 한 가지 형태 중 하나인 열대야를 대상으로 한국의 열대야 추세가 어떻게 변화하고 있는 지를 살펴보았다. 1973년부터 2018년까지 한국 기상청 ASOS 60개 지점의 일 최저 기온을 이용하여 여섯 개의 열대야 특성의 시간적인 변화를 분석하였다. 이러한 분석으로부터 열대야 관심지역은 인천, 강릉, 청주, 전주, 광주, 장흥, 여수, 거제, 구미, 영덕 등 10개 지역, 열대야 우심지역은 홍천, 양평, 수원, 원주, 보령, 대전, 부안, 정읍, 목포, 거창, 밀양, 포항, 제주, 서귀포 등 14개 지역이 식별되었다. 제안된 열대야 우심지역에는 특별한 열대야 대책이 수립될 필요가 있을 것이다.

식생냉각효과 적용을 통한 BioCAS의 폭염기간 일 최고기온 추정 개선 - 서울 및 수도권지역을 중심으로 - (Improvement of Vegetation Cooling Effects in BioCAS for Better Estimation of Daily Maximum Temperature during Heat Waves - In Case of the Seoul Metropolitan Area -)

  • 이한경;이채연;김규랑;조창범
    • 대기
    • /
    • 제29권2호
    • /
    • pp.131-147
    • /
    • 2019
  • On the urban scale, Micro-climate analysis models for urban scale have been developed to investigate the atmospheric characteristics in urban surface in detail and to predict the micro-climate change due to the changes in urban structure. BioCAS (Biometeorological Climate Impact Assessment System) is a system that combines such analysis models and has been implemented internally in the Korea Meteorological Administration. One of role in this system is the analysis of the health impact by heat waves in urban area. In this study, the vegetation cooling models A and B were developed and linked with BioCAS and evaluated by the temperature drop at the vegetation areas during ten selected heat-wave days. Smaller prediction errors were found as a result of applying the vegetation cooling models to the heat-wave days. In addition, it was found that the effects of the vegetation cooling models produced different results according to the distribution of vegetation area in land cover near each observation site - the improvement of the model performance on temperature analysis was different according to land use at each location. The model A was better fitted where the surrounding vegetation ratio was 50% or more, whereas the model B was better where the vegetation ratio was less than 50% (higher building and impervious areas). Through this study, it should be possible to select an appropriate vegetation cooling model according to its fraction coverage so that the temperature analysis around built-up areas would be improved.