• 제목/요약/키워드: Heat transmission coefficient

검색결과 53건 처리시간 0.031초

창의 경사도에 따른 열관류율 변화에 관한 연구 (A Study on the Change of Heat Transmission Coefficient According to the Degree of Windows Slope)

  • 황하진;이경희
    • 한국주거학회논문집
    • /
    • 제12권3호
    • /
    • pp.133-140
    • /
    • 2001
  • This study investigated the heat transmission coefficient through the experiment that the skylight, slope window of 60 degree and 30 degree consisted of pair glass and the double window of external window and internal window paper were suitable for heat insulation. As the result of experiment, the heat transmission coefficient of slope window was 1.06 times in the 60 degree, 1.18 times in the 30 degree and 1.31 times in the skylight as a standard lateral window. The heat transmission coefficient in the double window of external window and internal window paper was 3.017$\textrm{㎉}$/$\textrm{m}^2$.hr.$^{\cire}C$. The slope window was not suitable for the prescription by the increase of the heat transmission coefficient, so the user must pay attention to the treatment. This study investigated only the slope window of 12mm and 16mm pair glass and the double window of external window and internal window paper, study on the various pattern of window must be achived in a future.

  • PDF

수막하우스의 유량 및 수온에 따른 열전달 특성 분석 (Analysis of Heat Transfer Characteristics in Response to Water Flow Rate and Temperature in Greenhouses with Water Curtain System)

  • 김형권;김승희;권진경
    • 생물환경조절학회지
    • /
    • 제25권4호
    • /
    • pp.270-276
    • /
    • 2016
  • This study analysed overall heat transfer coefficient, heat transmission, and rate of indoor air heating provided by water curtain in order to determine the heat transfer characteristic of double-layered greenhouse equipped with a water curtain system. The air temperatures between the inner and outer layers were determined by the water flow rate and inlet water temperature. Higher water flow rate and inlet water temperature resulted in the increased overall heat transfer coefficient between indoor greenhouse air and water curtain. However, it was found that with higher levels of water flow rate and inlet water temperature, indoor overall heat transfer coefficient was converged about $10W{\cdot}m^{-2}{\cdot}^oC^{-1}$. The low correlation of overall heat transfer coefficient between water curtain and air within double layers was likely because the combination of greenhouse shape, wind speed and outdoor air temperature as well as water curtain affected the heat transfer characteristics. As water flow rate and inlet water temperature increased, the heat transferred into the greenhouse by water curtain also tend to rise. However it was demonstrated that the rate of heat transmission from water curtain into greenhouse with water curtain system using underground water was accounted for 22% to 28% for total heat lost by water curtain. The results of this study which quantify heat transfer coefficient and net heat transfer from water curtain may be a good reference for economical design of water curtain system.

참오동나무의 열처리가 기체투과성, 흡음율과 음향투과손실에 미치는 영향 (Effect of Heat Treatment on the Gas Permeability, Sound Absorption Coefficient, and Sound Transmission Loss of Paulownia tomentosa Wood)

  • KANG, Chun-Won;JANG, Eun-Suk;JANG, Sang-Sik;Cho, Jae-Ik;KIM, Nam-Hun
    • Journal of the Korean Wood Science and Technology
    • /
    • 제47권5호
    • /
    • pp.644-654
    • /
    • 2019
  • 참오동나무의 섬유방향기체투과성(gas permeability), 횡단방향 흡음율(sound absorption coefficient)과 음향투과손실(sound transmission loss)을 평가하고 열처리의 영향을 파악하고자 참오동나무 원반을 100, 160, $200^{\circ}C$로 열처리하고 기체투과성, 흡음율, 음향투과손실을 각각 측정하여 무처리 원반의 결과와 비교하였다. 그 결과, 두께 20 mm 참오동나무 원반의 섬유방향 기체투과성(specific permeability)은 무처리, 100, 160, $200^{\circ}C$ 열처리의 경우 각각 0.254, 0.279, 0.314, 0.452로 열처리에 의해 기체투과성이 약간 증가하였다. 두께 20 mm 무처리 참오동나무 원반의 50-6400 Hz 평균흡음율은 0.101이었으며 온도 100, 160, $200^{\circ}C$로 열처리한 목재의 50-6400 Hz 평균흡음율은 0.109, 0.096 그리고 0.106이었다. NRC (noise reduction coefficient) 는 각각 0.060, 0.067, 0.062 그리고 0.071 이었다. 두께 20 mm 무처리 참오동나무 원반의 50-6400 Hz 주파수범위에서 음향투과손실은 평균 36.93 dB이었다. 열처리에 의해 참오동나무 원반의 기체투과성과 흡음율은 열처리에 의해 그리고 열처리 온도 증가에 의해 약간 증가하였으나 증가정도는 미미하였다.

단열성 시험 방법을 통한 진공유리의 구성 및 필러 배치에 따른 열 성능 평가 (The Evaluation of Thermal Performance of Vacuum Glazing by Composition and the Pillar Arrangement through Test Method of Thermal Resistance)

  • 조수;김석현;엄재용
    • 한국태양에너지학회 논문집
    • /
    • 제35권1호
    • /
    • pp.61-68
    • /
    • 2015
  • The advanced counties effort to the supplement of the zero energy buildings for the global building energy saving. In the middle of the development of passive technology, the government has to effort to the energy saving of buildings by enhanced performance of the window thermal insulation. By the method of enhanced performance of window thermal insulation, the use of vacuum double glazing saves the energy consumption in building. This glazing has low U-value(heat transmission coefficient) than normal double glazing. The vacuum glazing enhanced thermal insulation performance by vacuum space of between the glass and glass. For this vacuum glazing, pillar maintain the space between glass and glass. But this structure cause the raising the heat transmission coefficient in pillar approaching glass. This study confirmed the U-value by the test method of thermal resistance for windows and doors. Also this study confirmed the variation of heat transmission coefficient by the structure of vacuum glazing. And this study measured the surface temperature of the vacuum glazing about pillar approaching glass and vacuum space in cool chamber and hot box. That result, this study confirmed U-value of $0.422W/m^2{\cdot}K$ of vacuum glazing. Also this study confirmed U-value of $0.300{\sim}0.422W/m^2{\cdot}K$ by various the structure of vacuum glazing. And this study confirmed the heat flow in pillar approaching glass.

최적 열전달계수를 이용한 단열기준산출

  • 이진원;이종원
    • 대한설비공학회지:설비저널
    • /
    • 제8권2호
    • /
    • pp.95-100
    • /
    • 1979
  • Optlmum overall heat transmission coefficient for residential buildings is calculated as a function of building parameter, area/volume. Equivalent heat transmission coefficient and equivalence factor are introduced and optimized with respect to annual cost including fuel cost , insulation cost and equipment cost Comparison with recent standard of West Germany shows similarity of the result.

  • PDF

내열성 세라믹스 재료의 분광복사특성 (Spectral Radiative Characteristics of Heat Resisting Ceramics Materials)

  • 상희선
    • 한국산업융합학회 논문집
    • /
    • 제4권1호
    • /
    • pp.35-40
    • /
    • 2001
  • A spectral measurement system for reflection and transmission properties by using an optical fiber and an ellipsoidal mirror was newly developed. The hemispherical reflectance and transmittance spectra of several heating resisting ceramics materials were measured from visible to middle infrared region. The directional characteristics of reflection and transmission were also investigated in consideration of the absorptance. The measured data were analyzed by using a four flux model of radiation transfer, The radiation properties could be estimated by the obtained scattering and absorption coefficient spectra.

  • PDF

온실 난방부하 산정방법의 검증 및 틈새환기와 지중전열의 영향 분석 (Validation of Load Calculation Method for Greenhouse Heating Design and Analysis of the Influence of Infiltration Loss and Ground Heat Exchange)

  • 신현호;남상운
    • 원예과학기술지
    • /
    • 제33권5호
    • /
    • pp.647-657
    • /
    • 2015
  • 원예시설의 환경설계 중 난방부하 산정방법에 대한 검증을 위하여, 대규모 플라스틱 온실에서 총난방부하와 틈새환기율, 지중전열량을 계측하여 계산결과와 비교 분석하였고, 지중전열 및 틈새환기가 온실의 난방부하에 미치는 영향을 검토하였다. 실험기간 동안 실내기온은 $13.3{\pm}1.2^{\circ}C$, 실외 기온은 $-9.4{\sim}+7.2^{\circ}C$의 범위를 보였으며, 우리나라의 난방 설계 외기온 범위에서 유효한 것으로 확인하였다. 가스트레이서법으로 측정한 틈새환기율은 평균 $0.245h^{-1}$로 나타났다. 온실의 피복면적에 일정한 환기전열계수값을 사용하는 방법은 온실의 규모에 따라서 문제가 있는 것으로 분석되었다. 따라서 환기전열부하는 온실의 체적과 틈새환기율을 이용하는 방법이 합리적인 것으로 판단된다. 온실 중앙에서 측정한 지중열류는 실내외 기온차에 따라 음으로 약간 증가하는 경향을 보이고, 온실 측면에서 측정한 지중열류는 실내외 기온차에 따라 양으로 크게 증가하는 경향을 보였다. 계측 결과를 바탕으로 온실의 외주부를 통한 열손실 개념을 도입한 새로운 지중전열부하 산정 방법을 개발하였으며, 검증결과 잘 일치하는 것으로 나타났다. 관류열부하는 대체로 실내외 기온차에 비례하는 것으로 나타났으나, 열관류율은 작아지는 경향을 보였다. 따라서 관류열부하 산정시 설계조건에 따라 열관류율의 선택에 주의를 기울여야 할 것으로 판단된다. 실험온실의 열관류율은 평균 $2.73W{\cdot}m^{-2}{\cdot}C^{-1}$로 단일피복의 플라스틱 온실 대비 60%의 열절감율을 보이는 것으로 나타났다. 전체 난방부하 중에서 관류열부하가 84.7~95.4%, 환기전열부하가 4.4~9.5%, 지중전열부하가 -0.2~+6.3%를 차지하는 것으로 나타났다. 관류열부하는 실내외 기온차가 낮은 그룹에서 더 큰 비율을 차지하고, 환기전열 부하는 실내외 기온차가 높은 그룹에서 더 큰 비율을 차지하는 것으로 나타났다. 지중전열부하의 경우 실내외 기온차가 낮은 그룹에서는 부하를 경감시키는 방향으로 작용하고, 실내외 기온차에 따라 부하를 증가시키거나 경감시키는 방향으로 작용하는 것으로 나타났으므로 이 기준 온도차의 선택이 중요한 것으로 판단된다. 지중전열부하에 비하여는 환기전열부하가 더 큰 비중을 차지하므로 에너지 절감을 위해서는 틈새환기율을 줄일 수 있는 대책이 필요한 것으로 판단된다.

전단연결재를 적용한 무기계 경량기포콘크리트(ALC) 샌드위치 외벽 패널의 단열성능에 미치는 영향요인 분석 (An Analysis of Factors Influencing Insulation Performance of Inorganic Autoclaved Lightweight Concrete Sandwich Wall Panels Using Shear Connectors)

  • 강동화;강동화;신동현;김형준
    • 대한건축학회논문집:구조계
    • /
    • 제34권1호
    • /
    • pp.79-87
    • /
    • 2018
  • The purpose of this study was to analyze factors influencing insulation performance of inorganic Autoclaved Lightweight Concrete(ALC) sandwich wall panels with the application of shear connectors. To analyze the effect of shear connectors on the thermal performance of sandwich wall panels, heat transfer analysis was conducted by using the three-dimensional heat transfer simulation software. Four types of shear connector such as Pin, Clip, Grid, and Truss were selected for insulation performance analysis. Thermal bridge coefficient was calculated by varying typical panel thickness and shear connector thickness and materials such as steel, aluminum, and stainless steel. The results showed that Grid and Truss type widely distributed along the section of sandwich wall panel had a great influence on the thermal bridge coefficient by changing the influence factors. Based on the results of thermal and structural performance analysis, effective heat transmission coefficient of the sandwich wall panel satisfying the passive house insulation criteria was calculated. As a result, it was found that heat transmission coefficient was increased from $0.132W/m^2{\cdot}K$ to $0.141{\sim}0.306W/m^2{\cdot}K$ depending on the shear connector types and materials. In the majority of cases, the passive house insulation criteria was not satisfied after using shear connectors. The results of this study were likely to vary according to how influence factors were set, but it is important to apply the methods that reduce the thermal bridge when there would be a possibility of greatly affecting the insulation performance.

진공유리의 설계 조건에 따른 단열 성능 연구 (A Study of Adiabatic Performance for Vacuum Glazing with Design Conditions)

  • 황일선;이영림
    • 한국생산제조학회지
    • /
    • 제21권4호
    • /
    • pp.582-587
    • /
    • 2012
  • Recently, the low-emissivity glass has been used to reduce the energy loss through building windows. However, it simply reduces the inflow of solar rays and has a relatively high heat transmission coefficient. To solve the problems, a high-efficiency vacuum glazing has been under development but it has not been actively used due to its high price and insufficient performance. In this paper, the effects of internal pressure, pillar (spacer) height, pillar diameter, pillar interval, emissivity etc. on the performance of vacuum glazing have been analyzed with three-dimensional computational fluid dynamics and structural analysis. As a result, the performance of vacuum glazing was predicted more accurately and major factors that determine the performance of vacuum glazing were optimized.

오피스건물 리뉴얼시 패시브 요소적용에 따른 에너지성능 및 PMV 개선에 관한 연구 (Analysis of Energy Performance and PMV Improvement by Application of Passive Factor for Office Building Renewal)

  • 홍원표
    • 조명전기설비학회논문지
    • /
    • 제28권12호
    • /
    • pp.55-64
    • /
    • 2014
  • This paper presents a case study to investigate the monthly calculation method of ISO 13790 applied for a office building. The energy performance analysis according to improvement of insulation and air permeability of windows in K office buildings is investigated by means of building energy efficiency rating tool ($ECO_2-OD$). The K building energy system is tested experimently by the measurement of PMV(predicted mean vote) for the control of indoor thermal environment and heat transmission coefficient of windows and interior walls respectively, before and after the example K office building is remodeled passively. Therefore, Internet based energy assessment program of energy efficiency rating of office building can be applied as a program for the annual energy requirement and for evaluation of energy savings from the experimental and simulation results.