• Title/Summary/Keyword: Heat transfer reduction

Search Result 286, Processing Time 0.023 seconds

Evaluation of Air-side Heat Transfer and Friction Characteristics on Design Conditions of Condenser (응축기의 설계조건에서 공기측 열전달계수 및 압력강하 산출)

  • 김창덕;전창덕;이진호
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.3
    • /
    • pp.220-229
    • /
    • 2003
  • An experimental study on the air-side pressure drop and heat transfer coefficient of slit fin-tube heat exchanger has been carried out. The data reduction methodology for air-side heat transfer coefficients in the literature is not based on a consistent approach. This paper focuses on new method of data reduction to obtain the air-side performance of fin-tube heat exchanger using R22 and recommends standard procedures for dry surface heat transfer estimation in fin-tube heat exchanger having refrigerant on the tube-side. Results are presented as plots of friction f-factor and Colburn j -factor against Reynolds number based on the fin collar outside diameter and compared with previous studies. The data covers a range of refrigerant mass fluxes of 150~250 kg/$m^2$s with air flows at velocity ranges from 0.6 m/s to 1.6 m/s.

The Drag Reduction and Convective Heat Transfer Characteristics of Two-Phase Flow with Polymer Additives (고분자 물질 첨가에 의한 2상 유동의 마찰 항력 감소와 대류 열전달 특성)

  • Lee, Dong-Sang;Kim, Jae-Guen;Cha, Kyong-Ok
    • Proceedings of the KSME Conference
    • /
    • 2000.04b
    • /
    • pp.71-76
    • /
    • 2000
  • This experimental study was conducted to figure out the drag reduction and convective heat transfer in vertical downward two-phase flow with polymer additives. The drag reduction effect were analyzed by using the difference of the pressure drop between the flow with polymer additives and without it. Experimental results show that the pressure drop with polymer additives is less than the pressure drop without polymer in vertical downward two-phase flow. And the convective heat transfer has decreased with increasing the polymer concentration in vertical downward two-phase flow.

  • PDF

Study on Designing and Installation Effect of Fresh Air Load Reduction System by using Underground Double Floor Space - Proposal of Numerical Model coupled Heat and Moisture Simultaneous Transfer in Hygroscopic - (지열을 이용한 공조외기부하저감(空調外氣負荷低減) 시스템의 설계 및 도입 효과에 관한 연구 - 증기 확산지배에 의한 열수분 동시 이동 수치모델의 제안 -)

  • Son, Won-tug;Choi, Young-sik
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.7 no.4
    • /
    • pp.331-340
    • /
    • 2004
  • This paper presents a feasibility study of a fresh air load reduction system by using an underground double floor space. The fresh air is introduced into the double slab space and passes through the opening bored into the footing beam. The air is cooled by the heat exchange with the inside surface of the double slab space in summer, and heated in winter. This system not only reduces sensible heat load of the fresh air by heat exchange with earth but also reduces latent heat load of the fresh air by ad/de-sorption of underground double slab concrete. In this paper, we used a model for evaluation of fresh air latent heat load reduction by hygroscopic of air to earth exchange system taking into account coupled heat and moisture transfer of underground double floor space. In conclusion it shows the validity of the proposed method for a design tool and the quantitative effect of the system.

  • PDF

Mechanism of Fouling Reduction and Heat Transfer Enhancement in a Circulating Fluidized Bed Heat Exchanger (순환유동층 열교환기 내의 화울링 저감 및 열전달 향상 기구)

  • Lee, Y.P.;Yoon, S.Y.;Jurng, J.S.;Kim, N.H.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.7 no.3
    • /
    • pp.450-460
    • /
    • 1995
  • A modified circulating fluidized bed heat exchanger under severe fouling condition is developed. The effects of fouling deposits on the performance of a heat exchanger are investigated. The principle and operating characteristics of a circulating fluidized bed heat exchanger are dicussed. A modified circulating fluidized bed heat exchanger shows more stable operating than the other circulating fluidized bed heat exchanger. The characteristics of self cleaning and heat transfer enhancement of a circulating fluidized bed heat exchanger are studied. The movement of spherical particles in a tube is visualized and heat transfer enhancement and scale reduction mechanism by particles are investigated.

  • PDF

A Study on the Heat Transfer Reduction due to the Clinker in the Thermal Poorer Plant (화력발전소에서 용융회가 열전달 감소에 미치는 영향에 관한 연구)

  • Kang, H.C.;Lee, K.W.
    • Journal of Power System Engineering
    • /
    • v.4 no.1
    • /
    • pp.13-19
    • /
    • 2000
  • This study was conducted for the heat transfer reduction due to the clinker formed in the furnace of the thermal power plant. The thermal properties of clinker such as thermal conductivity, specific heat, density and void fraction were measured. The thermal conductivities of the clinker were ranged $0.32-0.54W/m{\cdot}K$ and the average specific heat and the void fraction were $930J/kg{\cdot}K$ and 0.36 respectively. The thermal resistance of clinker was the greatest among the thermal resistances. It was found that the clinker reduces more than 90% of the heat transfer if the clinker is thicker than 10 cm.

  • PDF

A Study on Radiation Heat Transfer of Wafer Transfer Module Using Computational Flow Visualization (전산유동가시화를 활용한 웨이퍼 이송장치의 복사열전달에 관한 연구)

  • Min Gi, Chu;Ji Hong, Chung;Dong Kee, Sohn;Han Seo, Ko
    • Journal of the Korean Society of Visualization
    • /
    • v.20 no.3
    • /
    • pp.58-66
    • /
    • 2022
  • The high heat emitted from the process module and heat jacket may cause errors in semiconductor process equipment. Barriers were designed to reduce the temperature of surface on transfer module. A designed barrier was compared and analyzed by numerical analysis using ANSYS Fluent. The average temperature of barrier and effect of radiation heat transfer were also compared through absorbed radiative heat flux of the barrier. The adoption of the barrier had an effect on the radiative heat transfer reduction of the transfer module rod. The effect of the angles of barrier from 50° to 90° on the heat transfer was investigated using the absorbed radiative heat flux with the average temperature. The angle of barrier of 50° reduced the temperature up to 9.6 %.

Assessment of Explicit Algebraic Stress/Heat-Flux Models for Reduction of Heat Transfer in a Vertical Pipe with Intense Heating (Explicit Algebraic Stress/Heat-Flux 모형을 이용한 벽면가열이 높은 수직관 내의 열전달 감소에 대한 수치적 해석)

  • Baek, Seong-Gu;Park, Seung-O
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.27 no.12
    • /
    • pp.1724-1733
    • /
    • 2003
  • This paper assesses the prediction performance of explicit algebraic stress and heat-flux models for reduction of heat transfer coefficient in a strongly-heated vertical tube. Two explicit algebraic stress models and four explicit algebraic heat-flux models are selected for assessment. Eight combinations of explicit algebraic stress and heat-flux models are used in predicting the turbulent gas flows with intense heating, which yields the significant property-variation. The results showed that the two combinations of GS-AKN and WJ-mAKN predicted the Nusselt number and the axial wall temperature variations well and that the predictions of Nusselt number with WJ-combinations spread in a wider range than those with Gs-combinations. WJ is the explicit algebraic stress model of Wallin and Johansson and GS is the model of Gatski and Speziale and that AKN is the explicit heat-flux model of Abe, Kondoh and Nagano and mAKN is the modified AKN.

Nucleate Boiling Heat Transfer Coefficients of Mixtures Containing Propane, Isobutane and HFC134a

  • Park Ki-Jung;Jung Dong-Soo
    • Journal of Mechanical Science and Technology
    • /
    • v.20 no.3
    • /
    • pp.399-408
    • /
    • 2006
  • Nucleate pool boiling heat transfer coefficient (HTCs) were measured with one nonazeotropic mixture of propane/isobutane and two azeotropic mixtures of HFC134a/isobutane and propane/HFC 134a. All data were taken at the liquid pool temperature of $7^{\circ}C$ on a horizontal plain tube of 19.0mm outside diameter with heat fluxes of $10\;kW/m^2\;to\;80kW/m^2$ with an interval of $10\;kW/m^2$ in the decreasing order of heat flux. The measurements were made through electrical heating by a cartridge heater. The nonazeotropic mixture of propane/isobutane showed a reduction of HTCs as much as 41% from the ideal values. The azeotropic mixtures of HFC134a/isobutane and propane/HFC134a showed a reduction of HTCs as much as 44% from the ideal values at compositions other than azeotropic compositions. At azeotropic compositions, however, the HTCs were even higher than the ideal values due to the increase in the vapor pressure. For all mixtures, the reduction in heat transfer was greater with larger gliding temperature difference. Stephan and Korner's and lung et al's correlations predicted the HTCs of mixtures with a mean deviation of 11%. The largest mean deviation occurred at the azeotropic compositions of HFC134a/isobutane and propane/HFC134a.

Study on the Drag Reduction and Heat Transfer Efficiency Reduction of the Non-Ionic Surfactant (비이온 계면활성제의 마찰 및 열교환효율 저감 특성 연구)

  • Cho, Sung-Hwan;Tae, Choon-Seob
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.19 no.2
    • /
    • pp.133-141
    • /
    • 2007
  • The drag reduction (DR) and heat transfer efficiency reduction (HTER) of nonionic surfactant according to the fluid velocity, temperature and surfactant concentration were investigated experimentally. For this study, several kinds of new surfactant which contains amine-oxide and betaine were developed. And experimental apparatus equipped with two water storage tanks temperature controlled, pumps, testing pipe network, two flowmeters, two pressure gauges, heat exchanger, and data logging system was built. Results showed that existing alkyl ammonium surfactant (CTAC) had DR of $0.6{\sim}0.8$ for $1,000{\sim}2,000\;ppm$ in fluid temperature of $50{\sim}60^{\circ}C$ and had very low DR in fluid temperature over $70^{\circ}C$. And new amino oxide and betaine surfactant (SAOB) had lower DR in fluid temperature of $50{\sim}60^{\circ}C$ compared with CTAC but in fluid temperature of $70{\sim}80^{\circ}C$ DR was $0.6{\sim}0.8$ for 1$1,000{\sim}2,000\;ppm$.

Performance Evaluation in Fin-Tube Heat Exchanger by Tow-In Winglet Pairs (Tow in 와류발생기에 의한 핀-관 열교환기의 성능실험)

  • ;Kahoru Torii
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.2
    • /
    • pp.87-94
    • /
    • 2003
  • To reduce the air side pressure drop in air-cooled heat exchanger, tow-in type winglet vortex generators are applied. A specially designed multiple-channel test core was used in the experiments for the various geometry of winglet vortex generators. The proposed tow-in type vortex generator gives significant separation delay, reduces form drag, and removes the zone of poor heat transfer from near-wake of the tubes. The results show the significant pressure drop reduction for the tow-in win91e1 vortex generators with the similar enhancement of the heat transfer as other vortex generator applications in heat exchanger. In the range of Reynolds number of 350 to 2100 the pressure drop decrease 8∼15% and 34∼55% for the in-line and staggered tube banks, respectively, compared to those without vortex generators.