• 제목/요약/키워드: Heat supply

검색결과 952건 처리시간 0.029초

수소도시 내 마이크로 히트그리드 구성 방안 및 최적 규모 산정 연구 (A Study for Analysis of Micro Heat Grid Configuration and Deduction of Optimal Size in Hydrogen Cities)

  • 이종준;임슬예;신경아;김남웅;김도형;박철규
    • 한국수소및신에너지학회논문집
    • /
    • 제33권6호
    • /
    • pp.845-855
    • /
    • 2022
  • In response to climate change, the world is continuing efforts to reduce fossil fuels, expand renewable energy, and improve energy efficiency with the goal of achieving carbon neutrality. In particular, R&D is being made on the value chain covering the entire cycle of hydrogen production, storage, transportation, and utilization in order to shift the energy supply system to focus on hydrogen energy. Hydrogen-based energy sources can produce heat and electricity at the same time, so it is possible to utilize heat energy, which can increase overall efficiency. In this study, calculation of the optimal scale for hydrogen-based cogeneration and the composition of heat sources were reviewed. It refers to a method of the optimal heat source size according to the external heat supply and heat storage to be considered. The results of this study can be used as basic data for establishing a hydrogen-based energy supply model in the future.

급기가 되는 이중바닥 구조체의 열 성능 평가 (Estimation of the thermal performance on the double slab floor with supplying air)

  • 차광석;박명식;이대우;남우동
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.866-871
    • /
    • 2006
  • Recently according to the fashion of well-being, the case study of under floor heating system type for residential space is increasing. Specially double slab floor system can make several roles as reducing the acoustic noises and also supplying fresh air through the gap. So in present study floor heating performance was examined with various location of the space in the case of floor supply air and ceiling supply air. In both cases return air went out through ceiling opening. As one of the result is that when using the heat pipe type floor heating system the temperature difference between supply and return water was $15.2^{\circ}C$, but in case of commercial type floor heating system the temperature difference was $5.3^{\circ}C$ when the supply water temperature was $50^{\circ}C$.

  • PDF

신재생에너지의 온실가스감축 기여도에 따른 지역별 보급전략 (Regional Supply Strategies for Renewable Energy Sources based on Contribution Level of GHG Emission Reduction)

  • 김현석
    • Current Research on Agriculture and Life Sciences
    • /
    • 제32권4호
    • /
    • pp.215-223
    • /
    • 2014
  • This study examines the contribution level of greenhouse gas(GHG) emission reduction and installation costs of renewable energy facilities. The GHG emission forecasts and industrial structures in the 16 regions of Korea are then analyzed to identify the proper supply of renewable energy sources for each region. The results show that water power is the most effective and efficient renewable energy source to reduce GHG emissions, followed by sunlight, wind power, geothermal heat, and solar heat, respectively. The 16 regions are then categorized into 4 groups based on their GHG emission forecast and industrial structure: high emission and manufacturing group, low emission and manufacturing group, low emission and service group, and high emission and service group. The proper supply of renewable energy sources for each group is then determined based on the contribution level and cost efficiency of GHG emission reduction.

바닥온돌 매립형 환기덕트시스템의 온도변화에 대한 고찰 (The Changes of Temperature for Embedded Duct Ventilation System in Ondol)

  • 김옥;박진철;김남규;오재근
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.375-380
    • /
    • 2006
  • Embedded Duct Ventilation System in Ondol is embedded supply duct in Ondol. This system allows heat up outside air to inside temperature with out using heat exchanger and electric heating coiling in winter season. In this research, we measured temperature of inside and surface of Ondol, supply duct, and supply air temperature incorporate embedded duct ventilation system in Ondol in model house($110m^2$) & one room($23m^2$)

  • PDF

지하공기-물 직접접촉식 열교환기를 구비한 히트펌프의 성능 (Performance of Underground Air-to-Water Heat Pump with Direct Contact Heat Exchanger)

  • 김영화;강연구;성문석;유영선;김종구;장재경
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2010년도 춘계학술대회 초록집
    • /
    • pp.172.1-172.1
    • /
    • 2010
  • In Jeju, underground air is used for heating greenhouse and fertilizing natural $CO_2$ gas by suppling directly into greenhouse. But greenhouse heating method by direct supply of underground air has several problems as like low temperature below $20^{\circ}C$ or high relative humidity over 90%. The underground air is inadequate in heating of crops such as mangos, oranges with the growing temperature over $20^{\circ}C$. Also if the relative humidity of greenhouse is kept with over 90%, diseases can strike almost of the crops. And also the ventilation loss becomes larger because the air pressure of inside greenhouse by direct supply of underground air is higher. In this study the heat pump system using underground air as heat source was developed and heating performance of the system was analyzed. Heating COP of the system was 2.5~5.0 and rejecting heat into greenhouse and extracting heat from underground air in this heat pump system were 46.5~31.4 kW, 34.9~20.9 kW respectively.

  • PDF

배압터빈을 사용하는 열병합발전소의 열 회수 온도에 따른 성능특성 분석 (Performance Analysis on CHP Plant using Back Pressure Turbine according to Return Temperature Variation)

  • 임신영;이종준;전영신;김형택
    • 한국유체기계학회 논문집
    • /
    • 제19권6호
    • /
    • pp.26-33
    • /
    • 2016
  • Combined heat and power (CHP) system is one of the power generation system which can generate both electricity and heat. Generally, mid-size and big-size CHP plant in Korea generate electricity from gas turbine and steam turbine, then supply heat from exhaust gas. Actually, CHP can supply heat using district heater which is located at low pressure turbine exit or inlet. When the district heater locates after low pressure turbine, which called back pressure type turbine, there need neither condenser nor mode change operating control logic. When the district heater locates in front of low pressure turbine or uses low pressure turbine extraction steam flow, which calls condensing type turbine, which kind of turbine requires condenser. In this case, mode change operation methods are used for generating maximum electricity or maximum heat according to demanding the seasonal electricity and heat.

태양열 난방 일체형 복합시스템의 축열조 효율개선에 관한 연구 (The Study on Efficiency Improvement of Thermal Storage Tank for Solar Combined Heating System)

  • 류남진;고광수;한유리;박윤철
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2006년도 추계학술대회
    • /
    • pp.188-192
    • /
    • 2006
  • This study is conducted to improve efficiency of thermal storage tank. The thermal storage tank was designed to store heat energy that obtained from solar or the others heat sources. However, it has difficulties in storing heat with uniform temperature through the entire tank with respect to vertical direction. This kind of maldistribution of the supplied heat to the storage tank effects on the system performance. In this study is focused on utilization of the thermal stratification to improve thermal comfort for people in the house. To enhance temperature stratification of the tank, a distributor was designed and Installed in the middle of the tank. The distributor is supplies hottest water to the top side of the tank which is very close to inlet of the supply line to the heating load. The hottest water that is accumulated on top side of the tank is firstly supplied to the load with higher temperature. Reminder water takes a little time to warming up until desired supply temperature reached. This kind alternating selection of the supply temperature is improve thermal comfort with moderated system performance.

  • PDF

스테인리스-아세톤 히트파이프의 열전달 특성에 관한 실험적 연구 (An Experimental Study on the Heat Transfer Characteristics of Stainless-Acetone Heat Pipe)

  • 강금춘;김영중;유영선;백이;이건중
    • Journal of Biosystems Engineering
    • /
    • 제25권6호
    • /
    • pp.489-496
    • /
    • 2000
  • This study was conducted in order to find an ideal working fluid kind and a proper filling amount in the heat pipe as well as an inclined angle of heat pipe when they are placed to recover exhaust gas heat in the hot air heater. Followings are the findings of this research. 1. Of the four different working fluids-gasoline kerosene distilled water and acetone-acetone filled heat pipe showed the best performance giving out more homogeneous temperature profile on the radiating part than the kerosene and gasoline heat pipe an carrying out heat transmitting function better than the distilled water heat pipe by 10~2$0^{\circ}C$ higher on the radiating part. Acetone would be a good choice for recycling of exhaust gas heat in the hot air heater. 2. Of the filling amount of working fluid inside the heat pipes dry-out situations possible caused by insufficient filling were found in the filling amount of 5, 7.5 and 10% heat pipes as heat supply rate increases gradually in the range of 50 to 15kJ/sec. but no dry-out and stabilized heat transmitting performance occurred in the heat pipes of 12.5 and 15% filling at the same heat supply rate. It recommends that filling amount shall exceed 12.5% at least with the working fluids of this experiment. 3. The test revealed that the heat transmitting performance of heat pipe was more affected by filling amount rather than inclined angle.

  • PDF

보일러 운전조건 및 마감층 두께 변화에 따른 온돌난방공간의 열특성에 관한 실험연구 (An experimental study on the heat transfer characteristics of a Ondol-heated space by varying pipe embedding depths and hot water supply conditions)

  • 박병윤
    • 한국주거학회:학술대회논문집
    • /
    • 한국주거학회 1991년도 학술발표대회논문집
    • /
    • pp.41-47
    • /
    • 1991
  • This study reports the results of the transient temperature response of a floor heating panel according to variation of the hot water supply temperature and the pipe embedding depth. Also, this experiment compares the temperature responses of floor heating panels under the continuous and intermittent heating system. Furtthermore, this study presents some details of the thermal response of Ondol-heated buildings to varying loads and patterns of heat input. The analysis of the thermal performance fo Ondol heating system have been presented.

  • PDF