• 제목/요약/키워드: Heat retention

검색결과 255건 처리시간 0.029초

노출시간과 열강도에 따른 복사열 노출후의 소방보호복의 물리적 특성과 역학적 특성변화 (Changes of Physical and Mechanical Properties of Firefighter Protective Clothing After Radiant Heat Exposure)

  • 유화숙
    • 한국의류학회지
    • /
    • 제23권6호
    • /
    • pp.853-863
    • /
    • 1999
  • the change of physical properties (thickness, weight, air permeability) and mechanical properties(abrasion resistance breaking load and displacement) of samples were determined after heat exposure by a RPP tester. The effect of exposure time and heat flux intensity on the changes and the relationship between physical properties and mechanical properties were investigated. FR treated cotton Kevlar/PBI and Nomex with different structureal characteristics were chosen for specimens. The changes of physical properties and mechanical properties were calculated based on their initial values before heat exposure. The longer exposure time and the high heat flux intensity the more changes of those properties. Heat flux intensity was more effective on the changes, The showed to be affected by an interplay of shrinkage and pyrolysis products loss. The changes of thickness and abrasion resistance showed to be higher for plain weave fabric and those of air permeabiliyt and breaking load and displacement for twill weave fabric. While FR treated cotton which have high RPP value experienced serious and detrimental changes after heat exposure Kevlar/PBI which has low RPP value showed no high changes. In conclusion it could be confirmed that when total performance of a protective clothing is estimated retention capability of physical and mechanical properties after heat exposure as well as RPP value must be considered.

  • PDF

TMA 농도에 따른 포접화합물의 냉각특성에 대한 연구 (A Study on Cooling Characteristics of Clathrate Compound with Concentration of TMA)

  • 김진흥;정낙규;김창오
    • 에너지공학
    • /
    • 제14권1호
    • /
    • pp.18-23
    • /
    • 2005
  • 본 연구는 저온축열물질로서 TMA(Tri-methyl-amine, (CH₃)₃N)를 20~25 wt%로 포함하고 있는 TMA-물계 포접화합물의 냉각특성에 대하여 냉열원온도 -5℃에서 실험적으로 연구를 수행하였다. 연구결과, TMA의 질량농도가 증가할수록 상변화온도와 비열이 증가하였으며, 과냉도가 감소하고 액상유지시간이 단축되었다 특히, TMA 25wt%를 포함한 TMA-물계 포접화합물은 상변화온도 평균 5.8℃, 과냉도 8.0℃, 액상유지시간 10분, 비열 4.099kJ/kg℃를 나타내었다. 본 연구의 결과로부터 TMA-물계 포접화합물은 물보다 높은 상변화온도를 나타내었으며, 과냉도가 감소하고, 액상유지시간이 단축되는 과냉각 억제효과를 확인 할 수 있었다.

낮은 핀관 (low-fin tube)의 응축 열전달 성능에 관한 실험적 연구 (An Experimental Study on Condensation Heat Transfer of Low-Finned Tubes)

  • 김내현;정인권;김경훈
    • 설비공학논문집
    • /
    • 제7권2호
    • /
    • pp.298-309
    • /
    • 1995
  • Low-fin tubes are widely used to enhance condensation heat transfer. In this study, condensation heat transfer experiment was conducted on the low-fin tube using R-11. Three different fin densities-787 fpm (fins per meter), 1102 fpm. 1378 fpm-were tested. The results show that low-fin tube enhances the condensation heat transfer considerablely. The enhancement increases as the fin density increases. It was also found that the fin shape and height have a significant effect on the condensation heat transfer coefficient. Slender or high fins showed a higher condensing heat transfer coefficient compared with fat, low fins. For the tube with 1378 fpm, however, excessive fin height decreased the condensing heat transfer coefficient. The reason may be attributed to the increasing condensate retention angle as the fin density increases. The experimental data are compared with existing prediction models. Results show that Webb's surface tension model predicted the data best (within ${\pm}20%$), which confirms that surface tension plays the major role in low-fin tube condensation.

  • PDF

CORIUM BEHAVIOR IN THE LOWER PLENUM OF THE REACTOR VESSEL UNDER IVR-ERVC CONDITION: TECHNICAL ISSUES

  • Park, Rae-Joon;Kang, Kyoung-Ho;Hong, Seong-Wan;Kim, Sang-Baik;Song, Jin-Ho
    • Nuclear Engineering and Technology
    • /
    • 제44권3호
    • /
    • pp.237-248
    • /
    • 2012
  • Corium behavior in the lower plenum of the reactor vessel during a severe accident is very important, as this affects a failure mechanism of the lower head vessel and a thermal load to the outer reactor vessel under the IVR-ERVC (In-Vessel corium Retention through External Reactor Vessel Cooling) condition. This paper discusses the state of the art and technical issues on corium behavior in the lower plenum, such as initial corium pool formation characteristics and its transient behavior, natural convection heat transfer in various geometries, natural convection heat transfer with a phase change of melting and solidification, and corium interaction with a lower head vessel including penetrations of the ICI (In-Core Instrumentation) nozzle are discussed. It is recommended that more detailed analysis and experiments are necessary to solve the uncertainties of corium behavior in the lower plenum of the reactor vessel.

대하증(帶下症)의 형상의학적 치료 (Treatment of morbid leukorrhea with Hyungsang Medicine)

  • 김혜경;강경화;이용태
    • 동의생리병리학회지
    • /
    • 제21권2호
    • /
    • pp.539-542
    • /
    • 2007
  • After analyzing the cases of treating female patients troubled with morbid leukorrhea, the writer drew the conclusions as follows. The shapes of patients with morbid leukorrhea show a large number of shapes of Gi type, Sin type or being inclined to be vigorous Gi, to have depressive syndrome due to disorder of Gi, to be Fire's nature flared upward, to become retention of phlegm and fluid, to become retention of Gi or to become retention of heat, or San syndromes. Accompanied syndromes of morbid leukorrhea appear over the body of upper, middle or lowe portion. In lower cho, the symptoms are menopathy, menstrual irregularities, menstrual irregularities, oligomenorrhea, itching of external genitals, San syndromes, infertility, lumbago which are connected with uterus. And in the middle cho, those are indigestion, nausea, distress in the stomach, vomiting, swallowing acid connected with digestive organs. And also in the upper cho, globus hystericus, chest distress, headache, dizziness, neck stiffness, heat in the upper, pimples connected with upper cho are appeared. Among the prescriptions of treatment for morbid leukorrhea, Ijintang was applied with the widest range of all. Besides that there were mainly prescribed for symptoms such as Gamisachil-tang, Haenggihyangso-san, Gamigwibi-tang, hyangsapyeongwi-san, Onkyung-tang, Banchong-san, Yongdamsagan-tang, Sogampaedok-san, Ojeok-etc.

Effects of rehydration fluid temperature and composition on body weight retention upon voluntary drinking following exercise-induced dehydration

  • Park, Sung-Geon;Bae, Yoon-Jung;Lee, Yong-Soo;Kim, Byeong-Jo
    • Nutrition Research and Practice
    • /
    • 제6권2호
    • /
    • pp.126-131
    • /
    • 2012
  • The purpose of this study was to determine the effects of beverage temperature and composition on weight retention and fluid balance upon voluntary drinking following exercise induced-dehydration. Eight men who were not acclimated to heat participated in four randomly ordered testing sessions. In each session, the subjects ran on a treadmill in a chamber maintained at $37^{\circ}C$ without being supplied fluids until 2% body weight reduction was reached. After termination of exercise, they recovered for 90 min under ambient air conditions and received one of the following four test beverages: $10^{\circ}C$ water (10W), $10^{\circ}C$ sports drink (10S), $26^{\circ}C$ water (26W), and $26^{\circ}C$ sports drink (26S). They consumed the beverages ad libitum. The volume of beverage consumed and body weight were measured at 30, 60, and 90 min post-recovery. Blood samples were taken before and immediately after exercise as well as at the end of recovery in order to measure plasma parameters and electrolyte concentrations. We found that mean body weight decreased by 1.8-2.0% following exercise. No differences in mean arterial pressure, plasma volume, plasma osmolality, and blood electrolytes were observed among the conditions. Total beverage volumes consumed were $1,164{\pm}388$, $1,505{\pm}614$, $948{\pm}297$, and $1,239{\pm}401$ ml for 10W, 10S, 26W, and 26S respectively ($P$ > 0.05). Weight retention at the end of recovery from dehydration was highest in 10S ($1.3{\pm}0.7kg$) compared to 10W ($0.4{\pm}0.5kg$), 26W ($0.4{\pm}0.4kg$), and ($0.6{\pm}0.4kg$) ($P$ < 0.005). Based on these results, carbohydrate/electrolyte-containing beverages at cool temperature were the most favorable for consumption and weight retention compared to plain water and moderate temperature beverages.

다양한 열 처리방법에 대한 나물류의 엽산 잔존율 (Folate retention in Namul according to various heating methods)

  • 정재은;정혜정;현태선;박수진;천지연
    • 한국식품과학회지
    • /
    • 제51권5호
    • /
    • pp.425-431
    • /
    • 2019
  • 본 연구는 국내 나물류 7종을 표준화된 5가지 다른 조리방법으로 조리 후 엽산 함량 변화 및 잔존율을 비교하였다. 엽산 함량 분석은 trienzyme-L casei 미생물법을 이용하였으며, 분석법은 정확성, 정밀성, 직선성, 검출한계 및 정량한계 등의 분석수행특성을 측정하여 검증하였으며, 내외부 분석품질관리를 수행하여 분석의 신뢰도와 숙련도를 평가하였다. 모든 분석법 검증은 AOAC에서 제시한 가이드라인에 부합하였으며, 7개월 동안 실시한 내부품질관리 및 숙련도 시험에서 모두 신뢰도 구간에 들어가는 결과를 얻어 본 실험에서 분석된 데이터의 신뢰도를 확보할 수 있었다. 조리법에 따른 나물류의 엽산 함량은 조리 전 엽산 함량과는 상관없이 조리 방법에 따라 유의적으로 다르게 나타났다. 나물의 종류에 따라 엽산 리텐션에 차이를 보였는데 비교적 튀기기 조리 후 높은 엽산 함량을 보였고, 찌기 처리된 시료에서 낮은 함량이 나타났다. 엽산 잔존율은 취나물과 쑥갓을 제외한 나물류에서는 조리에 의해 전반적으로 증가된 잔존율을 보여, 나물류는 열처리 방법을 통한 조리 후 섭취하는 것이 엽산 섭취에 보다 효율적인 것으로 나타났다. 본 연구는 조리 후 변화되는 엽산 함량에 관한 신뢰도 높은 정보를 제공하고 있으므로 이를 국가영양데이터베이스 구축에 활용 가능할 것으로 사료된다.

비이온계 계면활성제 수용액이 PET직물의 습윤특성에 미치는 영향 (제2보) -계면활성제와 직물의 특성- (Effect of Nonionic Surfactant Solutions on Wetting and Absorbency of Polyethylene Terephthalate(PET) Fabrics (Part II) -Surfactants Characteristics and Fabric Properties-)

  • 김천희
    • 한국의류학회지
    • /
    • 제29권12호
    • /
    • pp.1546-1553
    • /
    • 2005
  • 비 이온계 계면활성제인 Span 20, Tween 20,40, 60, 80, 21, 61, 81, 65, 85 수용액이 PET직물의 습윤특성에 미치는 영향을 연구하였다. 5종류의 PET직물이 사용되었는데, PET 1, 2, 3은 밀도, 두께 등이 서로 다르고 가공은 되어 있지 않고, PET 4와 PET 5는 물리적 특성이 PET 2와 비슷한데 PET 4는 heat set가 공이 되어 있고 PET 5는 rewetting agent가 첨가되어 있다. PET직물의 습윤특성은 비이온계 계면활성제가 첨가되면 크게 향상되며, 수분 보유량은 $cos{\theta}$와 adhesion tension과 정의 상관관계를 보여준다. 친유기가 짧은 친수성 계면활성제나 불포화탄화수소 친유기 구조를 가진 계면활성제가 PET직물의 습윤특성 향상에 효과적이다. 계면활성제가 없을 경우 수분 보유량비(W/H)는 실 간 간격이 넓은 PET직물이 작은 직물보다 컸으나, 비이올계 계면활성제를 첨가할 경우 W/H는 실 간 간격에 관계없이 유사해졌다. 물리적 특성이 비슷해도 heat set가공이 되어 있는 직물은 가공이 되어 있지 않은 직물보다 W/H 값이 작았고, rewetting agent가 첨가된 직물은 W/H 값이 컸다.

열처리에 의해 제조된 강아지풀 기반 리튬 이온 이차전지용 탄소 음극재의 전기화학적 특성 (Electrochemical Characteristics of Setaria viridis-Based Carbon Anode Materials Prepared by Thermal Treatment for Lithium-Ion Secondary Batteries)

  • 김동기;임채훈;명성재;하나은;민충기;이영석
    • 공업화학
    • /
    • 제35권2호
    • /
    • pp.140-147
    • /
    • 2024
  • 바이오매스 활용을 높이기 위하여, 열처리 공정을 통해 강아지풀 기반 리튬 이온 이차 전지용 탄소음극재(SV-C)를 제조한 뒤 전기화학적 성능을 고찰하였다. 강아지풀의 열처리 온도가 750 ℃로 낮을 때 낮은 결정성과 높은 비표면적(126 m2/g)과 함께, 표면에 많이 존재하는 산소의 (-) 전하가 리튬을 끌어당김으로 인하여 비정전용량(1003.3 mAh/g, at 0.1 C)이 높지만, 용량 유지율은 61.0% (at 500 cycles and 1 C)로 낮아지는 것으로 여겨진다. 또한, 열처리온도가 1150 ℃로 증가하면 탄소층이 축합되어 배열이 우수해짐에 따라 구조 결함이 감소하여 기공이 크게 줄어 비표면적(32 m2/g)이 감소한 것으로 확인되었다. 또한, 음극재 표면결함이 감소하여 결정성이 높아지게 되면, 용량 유지율은 89.7% (at 500 cycles and 1 C)로 높지만, 결함 정도가 작아 활성점이 줄어들어 비정전용량이 471.7 mAh/g로 매우 낮은 것으로 여겨진다. 본 연구 범위에서, 열처리 온도에 따라 제조된 강아지풀 기반 탄소음극재의 경우, 비표면적에 비해 표면 산소 함량과 결정성 등이 음극재의 전기화학적 특성에 더 높은 신뢰도를 갖는 것으로 나타났다.

합성수지 인공치와 열중합의치상 Resin의 결합시 인공치에 형성하는 유지공의 효과에 관한 연구 (The effect of retention grooves in Acrylic resin tooth denture base bond)

  • 김부섭
    • 대한치과기공학회지
    • /
    • 제9권1호
    • /
    • pp.51-55
    • /
    • 1987
  • One of the primary advantages of acrylic resin teeth is their ability to bond chemically to the denture base resins. Fracture od acrylic resin teeth from a maxillary denture, however, is not uncommon. Bonding failures have been attributed to faulty boil-out procedures that fail to eliminate all traces of wax from the ridge lap surfaces of the teeth and to contamination of the ridge lap surface by careless application of tinfoil substitute. Attempts to increase the strength of the bond between acrylic resin teeth and heat-cured denture base resin include grinding the glossy ridge lap surface (in fluid system), painting the ridgelap surface of the teeth with monomer-polymer solution, and cutting retention grooves in the ridge lap surface of the teeth. This latter method has been tested by applying a tensile force in a labial direction to the incisal part of the lingual surface of the acrylic resin teeth. A progressive shear compressive load was applied at an angle to the lingual surface of acrylic resin teeth bonded to denture base acrylic resin. No statistically singificant advantage was derived by preparing retention grooves of different shapes in the ridgelap surface of the denture teeth.

  • PDF