• Title/Summary/Keyword: Heat resistance

Search Result 2,867, Processing Time 0.031 seconds

A study on the weld nugget formation in resistance spot welding of aluminum alloy (알루미늄 합금의 저항 점 용접시 용접너깃의 형성에 대한 연구)

  • 나석주;오세진
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.10 no.5
    • /
    • pp.661-669
    • /
    • 1986
  • In this study, the resistance spot welding process of an aluminum alloy was analyzed through the numerical simulation including the electric contact resistance and the heat generation in the electrode. The finite element model was used to solve the electro-thermal responses in weld cycles. The resistance of the contact area was represented as the contact element modeling, but the thermal resistance between the contact surfaces was neglected. Welding tests of Alclad 2024-T3 aluminum alloy were made not only to get the input data for the numerical simulation, but also to compare the numerical results. The contact resistance was determined initially by the contact resistance tests and assumed to decay exponentially up to the solidus temperature. The temperature distributions and dynamic resistance obtained numerically were in good agreement with the experimental results. Numerical results revealed that nugget growth depends mainly on the heat generated in the workpiece and its contact area. The heat generated in the electrode has, however, only a little effect on the nugget growth, and the heat generation in the electrode-workpiece interface is initially high but decrease repidly.

A Study on the Physical Properties of Heat resistance and Cut resistance of Coating Gloves for Work

  • Pyo, Kyeong-Deok;Jung, Eugene;Park, Cha-Cheol
    • Elastomers and Composites
    • /
    • v.54 no.2
    • /
    • pp.91-96
    • /
    • 2019
  • The purpose of this study was to examine the effect of different yarn twisting methods on physical properties. Plain single jersey structured fabrics were knitted from Kevlar yarn, and from Kevlar/HPPE, and from Kevlar/Basalt fiber, and from Kevlar/Glass fiber and Kevlar/Stainless steel fiber blended and core-spun yarns. and then, The fabrics were coated NBR Latex. The physical properties, including tear strength, modulus, degree of penetration, heat resistance, and cut resistance of the knitted fabrics were investigated and compared. Kevlar/HPPE blended yarn fabrics recorded the highest heat resistance (13 Sec.). and Kevlar/HPPE blended yarn fabrics had good cut resistance (Cut Level 4).

A Study on the Thermal Contact Resistance Evaluation for Fin-Tube Heat Exchangers (핀-관 열교환기에서의 접촉열저항 평가에 관한 연구)

  • Jeong, J.;Kim, C.N.;Youn, B.;Gil, S.H.;Yang, J.S.
    • Proceedings of the KSME Conference
    • /
    • 2000.11b
    • /
    • pp.291-296
    • /
    • 2000
  • Usually the contact between fin collar and tube surface for fin-tube heat exchanger is secured by mechanical expansion of the tubes. The objective of the present study is to develop a method of measuring the thermal contact resistance between fin collar and tube surface for fin-tube heat exchanger. Also an experimental work has been performed to evaluate the thermal contact resistance, and a rigorous numerical analysis has been employed to calculate the contact resistance from the measured data. The experiments have been conducted fur the fin-tube heat exchangers with the tube of outer diameters 7 and 9.52 mm.

  • PDF

Effect of pH and Nisin on Heat Resistance of Listeria monocytogenes Scott A (Listeria monocytogenes의 열저항성에 미치는 pH와 Nisin의 효과)

  • 이신호;조현순
    • Microbiology and Biotechnology Letters
    • /
    • v.21 no.3
    • /
    • pp.200-206
    • /
    • 1993
  • The effect of pH (7, 5 and 4) and nisin (100 and 200IU/ml) on heat resistance of Listeria monocytogenes Scott A were determined using citrate-phosphate buffer system. Heat resistance of vegetative and starved cell was decreased as pH value was lower at 65 and 72C. Starved L. monocytogenes was more resistant than vegetative cell at both temperature. Heat resistance of vegetative and starved cell was decreased significantly with treatment of nisin. The effect of nisin was increased significantly at low pH(5, 4). Adherent microcolony was more resistant to heat and nisin than planktonic cell. Contamination of L. monocytogenes may be prevent by using nisin in food and food processing environments.

  • PDF

Evaluation of the Characteristics of the Aluminum Alloy(AC8A) Casting Material by Heat Treatment(II) (AC8A 알루미늄 합금 주조재의 열처리에 의한 특성 평가(II))

  • Moon, Kyung-Man;Jeong, Jae-Hyun;Lee, Myeong-Hoon;Baek, Tae-Sil
    • Journal of Power System Engineering
    • /
    • v.20 no.5
    • /
    • pp.29-36
    • /
    • 2016
  • Aluminum alloys have been widely used in engine materials, cold & hot-water storage vessels and piping etc., Furthermore, the aluminum alloy of AC8A have been widely used in mold casting material of engine piston for various vehicles because of its properties of temperature, wear and corrosion resistance. Therefore, it is considered that evaluation of corrosion resistance as well as wear resistance of AC8A material is also important to improve its property and to prolong its lifetime. In previous paper, the effect of solution($510^{\circ}C$:4hrs) and tempering($190^{\circ}C$: 16, 24, and 36 hrs)heat treatments to corrosion resistance and hardness were investigated using electrochemical method. In this study, in order to examine completely the effect of the tempering hours to hardness variation and corrosion resistance, the results of solution($510^{\circ}C$:4hrs) and tempering($190^{\circ}C$: 2, 4, 8 and 12hrs)heat treatments to hardness and corrosion resistance were investigated using electrochemical method. The hardness decreased with solution heat treatment compared to mold casting condition, but its value increased with tempering heat treatment. Furthermore, the corrosion resistance increased with decreasing of the hardness, and decreased with increasing of the hardness reversely. And the tempering heat treatment temperature at $190^{\circ}C$ for 8 hrs exhibited the highest value of the hardness and also indicated the highest corrosion current density. However, the values of hardness and corrosion current density was again increasingly decreased with increasing of tempering hours than 8 hrs, Consequently, it is suggested that decision of the optimum. tempering hours is very important to improve the corrosion or wear resistance.

Evaluation of the Characteristics of the Aluminum Alloy Casting Material by Heat Treatment (AC8A 알루미늄합금 주조재의 열처리에 의한 특성 평가)

  • Lee, Syung Yul;Park, Dong Hyun;Won, Jong Pil;Kim, Yun Hae;Lee, Myung Hoon;Moon, Kyung Man;Jeong, Jae Hyun
    • Corrosion Science and Technology
    • /
    • v.11 no.6
    • /
    • pp.280-285
    • /
    • 2012
  • Aluminum is on active metal, but it is well known that its oxide film plays a role as protective barrier which is comparatively stable in air and neutral aqueous solution. Thus, aluminum alloys have been widely applied in architectural trim, cold & hot-water storage vessels and piping etc., furthermore, the aluminum alloy of AC8A have been widely used in mold casting material of engine piston because of its properties of temperature and wear resistance. In recent years, the oil price is getting higher and higher, thus the using of low quality oil has been significantly increased in engines of ship and vehicle. Therefore it is considered that evaluation of corrosion resistance as well as wear resistance of AC8A material is also important to improve its property and prolong its lifetime. In this study, the effect of solution and tempering heat treatment to corrosion and wear resistance is investigated with electrochemical method and measurement of hardness. The hardness decreased with solution heat treatment compared to mold casting condition, but its value increased with tempering heat treatment and exhibited the highest value of hardness with tempering heat treatment temperature at $190^{\circ}C$ for 24hrs. Furthermore, corrosion resistance increased with decreasing of the hardness, and decreased with increasing of the hardness reversely. As a result, it is suggested that the optimum heat treatment to improve both corrosion and wear resistance is tempering heat treatment temperature at $190^{\circ}C$ for 16hrs.

Heat Flow Analysis in the Newly Developed Wave Heat Sink by Computational Simulation (전산모사에 의한 웨이브 히트싱크의 열유동 특성 해석)

  • Lee In-Gyu;Lee Sang-Woong;Kang Kae-Myung;Chang Si-Young
    • Korean Journal of Materials Research
    • /
    • v.14 no.12
    • /
    • pp.870-875
    • /
    • 2004
  • Heat flow characteristics in the newly developed Wave Heat Sink were analyzed under natural and forced convections by Icepak program using the finite volume method. Temperature distribution and thermal resistance of Wave Heat Sink with/without air vent hole on the top of fin were compared with those of a commercial Al extruded heat sink(Intel Heat Sink). Under the natural convection, the maximum temperature was $45.1^{\circ}C$ in the air vent hole typed Wave Heat Sink, which was superior to that of Intel Heat Sink. The thermal resistance was $2.51^{\circ}C/W$ in the air vent hole typed Wave Heat Sink, and it changed to $2.65^{\circ}C/W\;and\;2.16^{\circ}C/W$ with changes of gravity direction and fin height, respectively. Under the forced convection, the maximum temperature became lower than that under the natural convection. In addition, the thermal resistance lowered in the air vent hole typed Wave Heat Sink with higher fin height and it decreased with increasing the air flux.

An Experimental Study on the Thermal Performance of Sinusoidal Axially Grooved Heat Pipe (축방향 Sinusoidal 그루브를 갖는 히트파이프의 열성능에 관한 실험적 연구)

  • 서정세;정상완;정경택
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.8
    • /
    • pp.691-697
    • /
    • 2004
  • Experimental study is carried out to investigate the heat transport capability and thermal resistance of sinusoidal axially grooved heat pipe, comparing its performance to trapezoidal axially grooved heat pipe. As a result from this work, the heat transport capability of sinusoidal grooved heat pipe is lower than that of trapezoidal grooved heat pipe for the same size of outer diameter. As the ratio of depth to width of sinusoidal groove heat pipe is higher, the heat transport capability of heat pipe becomes higher. It is found that Aluminum-ammonia heat pipes with sinusoidal and trapezoidal grooves have good thermal resistance, below 0.1$^{\circ}C$/W at evaporator section and below 0.05$^{\circ}C$/W at condenser section.

Thermal Analysis of Heat Sink Models using CFD simulation (CFD를 이용한 히트싱크의 열 해석)

  • Lim, Song-Chul;Lee, Myung-Ho;Kang, Kae-Myung
    • Korean Journal of Materials Research
    • /
    • v.15 no.12
    • /
    • pp.829-832
    • /
    • 2005
  • Thermal analysis of new designed heat-sink models was carried out according to the natural ana the forced convection using computational fluid dynamics(CFD). Heat resistance of wave type, top vented wave type and plate type of heat sink was compared with each other As the direction of fin and air flow are vertical(z-axis), it is shown that radiant heat performance of all of heat sinks was superior than other experimental conditions. Especially, the heat resistance of top vented wave heat sink was $0.17^{\circ}C/W$(forced convection) and $0.48^{\circ}C/W$(natural convection). The radiant heat performance of heat sink was increased with increasing the height of fin and the width of fin pitch.

Influence of heat treatments on electrical properties of ZnO films grown by molecular-beam epitaxy

  • O, Dong-Cheol;Kim, Dong-Jin;Bae, Chang-Hwan;Gu, Gyeong-Wan;Park, Seung-Hwan
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2010.06a
    • /
    • pp.34-34
    • /
    • 2010
  • We report on the influence of heat treatments on the electrical properties of ZnO films grown by molecular-beam epitaxy. We note that the electrical resistance of the ZnO films is significantly changed by the heat treatments: the electrical resistance increases with the increase of ambient temperature, but above a critical temperature the resistance decreases with the increase of temperature, irrespective of ambient gases. On the other hand, it is found that the large amount of photocurrent is generated in the ZnO films, exposed to white sources: the photocurrent decreases with the increase of the obtained resistance, and the current increases with the decrease of the resistance. Also, it is shown that the X-ray diffraction linewidth of the ZnO films is significantly decreased by the heat treatments. These indicate that the increase/decrease of the electrical resistance is ascribed to the annihilation/formation of the residual donor-type defects in the ZnO films by the heat treatments. It is suggested that the increase of the electrical resistance is due to the annihilation of Zni-complex defects, while the decrease of the electrical resistance is due to the formation of VO-complex defects.

  • PDF