• Title/Summary/Keyword: Heat rate

Search Result 5,894, Processing Time 0.036 seconds

Numerical study of heat and mass transfer around an evaporative condenser tube by multi-zone method (다중 영역법을 이용한 증발식 응축관 주위의 열 및 물질전달 해석)

  • ;;Yun, In-Chul;Yoo, Je-In
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.19 no.12
    • /
    • pp.3317-3328
    • /
    • 1995
  • The objective of the present study is to predict the characteristics of heat and mass transfer around an evaporative condenser. Numerical calculations have been performed using multi-zone method to investigate heat transfer rate and evaporation rate with the variation of inlet condition(velocity, relative humidity and temperature) of the moist air, the flow rate of the cooling water and the shape of the condenser tube. From the results it is found that the profile of heat flux is the same as that of evaporation rate since heat transfer along the gas-liquid interface is dominated by the transport of latent heat in association with the vaporization(evaporation) of the liquid film. The evaporation rate and heat transfer rate is increased as mass flow rate increases or relative humidity and temperature decrease respectively. But the flow rate of the cooling water hardly affect the evaporation rate and heat flux along the gas-liquid interface. The elliptic tube which the ratio of semi-minor axis to semi-major axis is 0.8 is more effective than the circular tube because the pressure drop is decreased. But the evaporation rate and heat flux shown independency on the tube shape.

Uncertainty Estimation Model for Heat Rate of Turbine Cycle (터빈 사이클 열소비율 정확도 추정 모델)

  • Choi, Ki-Sang;Kim, Seong-Kun;Choi, Kwang-Hee
    • Proceedings of the KSME Conference
    • /
    • 2004.11a
    • /
    • pp.1721-1726
    • /
    • 2004
  • Heat rate is a representative index to estimate the performance of turbine cycle in nuclear power plant. Accuracy of heat rate calculation is dependent on the accuracy of measurement for plant status variables. Uncertainty of heat rate can be modeled using uncertainty propagation model. We developed practical estimation model of heat rate uncertainty using the propagation and regression model. The uncertainty model is used in the performance analysis system developed for the operating nuclear power plant.

  • PDF

Temperature monitoring and seasonal borehole heat exchange rate characteristics of a geothermal heat pump system (지열 히트펌프 시스템의 계절별 지중 열교환 특성 및 지반내 온도 변화)

  • Shim, Byoung-Ohan
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2007.06a
    • /
    • pp.452-455
    • /
    • 2007
  • The geothermal heat pump system is designed for cooling and heating for three stories building (2,435 $m^2$) includes total 79 heat pumps. Therefore, the monitoring system is installed for each floor and the data is automatically transmitted to the monitoring system. Heat exchange rate and temperature of a geothermal heat pump system have been monitored for a long period. The seasonal operation of geothermal heat pump shows the different shape of heat exchange rate for cooling and heating. Ground water flow can influence on heat exchange rate and thermal storage of the system. In order to define the hydraulic characteristics and groundwater temperature variation, the relationships among air temperatures, groundwater temperatures, water table, and precipitation are analysed.

  • PDF

Fire Characteristics of Composites for Interior Panels Using Cone calorimeter (콘칼로리미터를 이용한 내장판용 복합재료의 화재특성)

  • 이철규;정우성;이덕희
    • Journal of the Korean Society for Railway
    • /
    • v.7 no.1
    • /
    • pp.55-59
    • /
    • 2004
  • Composite materials were used widely due to merit of light weight, low maintenance cost and easy installation. But it is the cause of enormous casualties to men and properties because of weak about the fire. Particularly, it is more serious in case of subway train installed composite materials. For this reason, experimental comparison has been done fur measuring heat release rate(H.R.R) and smoke production rate(S.P.R) of interior panels of electric motor car using cone calorimeter. A high radiative heat flux of 50kW/㎡ was used to bum out all materials and to simulate the condition of fully developed fire case in the tests. It was observed that Heat Release Rate and Smoke Production Rate curves were dependent on the kinds of the interior materials. From the heat release rate curves, the sustained ignition time, peak heat release rate and total heat release rate were deduced, These data are useful in classifying the materials by calculating two parameters describing the possibility to flashover.

An Experimental Study on Heat Storage and Heat Recovery Characteristics of a Latent Heat Storage Tank with Horizontal Shell and Tube Type (수평식 셸-튜브형 잠열축열조의 축열 및 방열특성에 관한 실험적 연구)

  • Kwon, Young-Man;Seo, Hye-Sung;Moh, Jung-Ha
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.24 no.1
    • /
    • pp.50-59
    • /
    • 2000
  • An experimental study has been carried out in order to investigate the heat storage characteristics for a latent heat storage tank with horizontal shell and tube type. The heat exchanger consisted of horizontal cylindrical capsules with a staggered tube bank layout. Based on the obtained data, the effects of flow rate and inlet fluid temperature on the melting time and heat storage rates were examined. It is found that the melting time decreased with increase of the flow rate and the inlet temperature. Results also show that at the initial stage of heat transfer the heat storage rate represents the maximum value and rapidly decreases.

A Study on the Heat and Moisture Transport Properties of Vapor-Permeable Waterproof Finished Fabrics for Sports Wear (스포츠웨어용 투습방수직물의 열·수분이동 특성에 관한 연구)

  • Son, Bu Hun;Kim, Jin-A;Kwon, Oh Kyung
    • Fashion & Textile Research Journal
    • /
    • v.2 no.3
    • /
    • pp.220-226
    • /
    • 2000
  • This study was to determine the characteristics of vapor-permeable waterproof finished fabric by the coating method. 4 different kinds of coating fabrics (A : wet, porous, polyurethane, B : dry, no porous, polyurethane, C : shape memory polyurethane and D : dry, porous polyurethane) were used, which were developed recently With this sample, moisture transport rate ($40^{\circ}C$, 45%RH & $40^{\circ}C$, 95%RH), changes of coating side's shape by washing times, water repellency rate, contracted length, qmax, heat conductivity, heat keeping rate, heat keeping rate with cotton, heat keeping rate on humidity temperature and humidity within clothing etc. were checked. And it was done in a climate chamber under $20{\pm}2^{\circ}C$, $65{\pm}5%RH$. The results of this study were as follow; In the moisture vapor transmission of sample B and C increased on high temperature and high humidity while sample A and D decreased, on this condition. Qmax rate had high relation with ground fabric's surface properties and the order was A>C>D>B. Heat conductivity had high relation with thickness and surface properties. Heat keeping rates on sweat condition showed around half percents of heat keeping rates on normal condition, but had no relation with moisture vapor transport rate. Changes of the fabric's properties by washing times were different in accordance with the construction of fabrics and the coating resin. Sample C had tow heat keeping rate on the high temperature and humidity and high heat keeping rate on the low temperature and humidity Moisture transport rate of vapor-permeable waterproof finished fabrics had high relation with the properties of ground fabrics on low humidity condition, but on the high humidity condition, it was highly related with the properties of coating resin.

  • PDF

Burning Characteristics of Wood-based Materials using Cone Calorimeter and Inclined Panel Tests

  • Park, Joo-Saeng;Lee, Jun-Jae
    • Journal of the Korean Wood Science and Technology
    • /
    • v.30 no.3
    • /
    • pp.18-25
    • /
    • 2002
  • Research to discuss the fire performance of materials requires tools for measuring their burning characteristics and validated fire growth models to predict fire behavior of the materials under specific tire scenarios using the measured properties as input for the models. In this study, burning characteristics such as time to ignition, weight loss rate, flame spread, heat release rate, total heat evolved, and effective heat of combustion for four types of wood-based materials were evaluated using the cone calorimeter and inclined panel tests. Time to ignition was affected by not only surface condition and specific gravity of the tested materials but also the type and magnitude of heat source. Results of weight loss rate, measured by inclined panel tests, indicated that heat transfer from the contacted flame used as the heat source into the inner part of the specimen was inversely proportional to specific gravity of material. Flame spread was closely related with ignition time at the near part of burning zone. Under constant and severe external heat flux, there was little difference in weight loss rate and total heat evolved between four types of wood-based panels. More applied heat flux caused by longer ignition time induced a higher first peak value of heat release rate. Burning characteristics data measured in this study can be used effectively as input for fire growth models to predict the fire behavior of materials under specific fire scenarios.

THE LOAD DEFLECTION RATE OF LOOPED WIRE AND ITS CHANGE BY HEAT TREATMENT (looped wire의 하중변형도와 열처리에 의한 변화)

  • Lee, Yong-Kook
    • The korean journal of orthodontics
    • /
    • v.16 no.1
    • /
    • pp.133-144
    • /
    • 1986
  • This study was conducted to evaluate the effects of loop formation and heat treatment upon the elastic properties of orthodontic wires. The specimens selected were .016', .018', .016x.022', and .018x.022' sized stainless steel (standard) and cobalt-chromium-nickel wires, and were divided into 7 groups as; 1. straight non-heat treated 2. U looped non-heat treated 3. L looped non-heat treated 4. Circle looped non-heat treated 5. U looped heat treated 6. L looped heat treated 7. Circle looped heat treated Heat treatment was performed in Big Jane furnace at 850' F for 3 minutes. The elastic limit and the elastic range of each specimen were determined by bending test, and load deflection rate was computed from those values. The findings were as follows; 1. The formation of loop resulted in increased load-deflection rate for both stainless steel and cobalt-chromium-nickel wires. 2. The heat treated group showed higher load-deflection rate than non-heat treated group, which was more apparent in cobalt-chromiumnickel wire than in stainless steel wire. 3. L loop had the highest load-deflection rate among 3 types of loops, followed by U loop and circle loop. 4. The specimens with greater diameter displayed the more increase in load-deflection rate by looping and heat treatment.

  • PDF

A Study on the Heating Performance of Ground Source Heat Pump System (지중열원 열펌프 시스템의 난방성능 해석)

  • Woo Joung-Son;Kim Dae-Ki;Lee Se-Kyoun
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.12
    • /
    • pp.1175-1182
    • /
    • 2004
  • Installations of vertical boreholes for the ground source heat pump system are expensive to install. One way to reduce the initial cost is to increase the specific heat extraction rate of borehole system. However, as the specific heat extraction rate increases the temperature of borehole fluid decreases with the resultant lower Coefficient Of Performance in Heating(COPH) of heat pump system. The purpose of this study is to provide the basic informations about the performance of heat pump system with the specific heat extraction rate and soil thermal properties such as thermal conductivity and temperature. It is shown that the specific heat extraction rate is the most important parameter for the ground source heat pump system. To obtain the reasonable COPH value (COPH > 3) the heat extraction rate should be about 25 W/m or less. Accurate measurements of soil thermal properties are also very important to design the system properly. The effects of borehole thermal resistances are also examined in this study.

Heat Transfer Characteristics for Internally Triangular finned Rotating Heat Pipes (내부(內部)에 삼각형(三角形) 핀이 부착(附着)된 회전형(回轉型) 히이트파이프의 전열특성(傳熱特性))

  • Kwon, Sun-Sok;Jun, Chul-Ho;Jang, Yeong-Suk;Seo, Hae-Sung
    • Solar Energy
    • /
    • v.9 no.1
    • /
    • pp.43-52
    • /
    • 1989
  • Heat transfer rate and heat flux from the condenser with internally triangular fins rotating heat pipe has been numerically studied by finite element method. The results of numerical and P.J. Martos' experimental showed good agreement and it was able to predict to the performance of a rotating heat pipe. By increasing fin half angle or fin height, heat transfer rate from condenser was increased slightly but heat flux was decreased. By increasing condenser radius or r.p.m. of rotating heat pipe, heat transfer rate and heat flux was increased rapidly. Heat transfer rate was rapidly increased with increasing fin numbers in case of few fm numbers but slowly increased at many fin numbers. So the optimum fin numbers were a half of maximum fin numbers which was able to install in the condenser of a rotating heat pipe.

  • PDF