• 제목/요약/키워드: Heat of transition

검색결과 586건 처리시간 0.024초

Glass Transition Temperature of Honey Using Modulated Differential Scanning Calorimetry (MDSC): Effect of Moisture Content

  • Kim, Mi-Jung;Yoo, Byoung-Seung
    • Preventive Nutrition and Food Science
    • /
    • 제15권4호
    • /
    • pp.356-359
    • /
    • 2010
  • Glass transition phenomena in nine Korean pure honeys (moisture content 18.3~20.1%) and honey-water mixtures by different water contents (0, 2, 5, and 10% w/w) were investigated with modulated different scanning calorimetry (MDSC). The total, reversing, and non-reversing heat flows were quantified during heating using MDSC. Glass transition was observed from reversing heat flow separated from the total heat flow. The glass transition temperatures ($T_g$) of pure honeys, which are in the range of $-42.7^{\circ}C$ to $-50.0^{\circ}C$, varied a lot with low determination coefficient ($R^2$=0.63), whereas those of honey-water mixtures decreased with a decrease in honey content. The $T_g$ values were also more significantly different among honey-water mixtures when compared to pure honeys, indicating that in the honey-water mixture system the $T_g$ values appear to be greatly dependent on moisture content. The measured heat capacity change (${\Delta}C_p$) was not influenced by moisture content.

원통형 회전 히트파이프의 내부 유동 및 열전달 특성에 관한 연구 (A Study on the Internal Flow Patterns and Heat Transfer Characteristics for a Cylindrical Rotating Heat Pipe)

  • 이진성;이재준;김철주
    • 대한기계학회논문집B
    • /
    • 제22권9호
    • /
    • pp.1217-1228
    • /
    • 1998
  • In order to elucidate the operational characteristics of rotating heat pipes, the internal flow patterns and heat transfer performance are investigated. Flow patterns and its transition are studied with various rotational speeds by visualizing flows established inside a rotating tube. To verify those results of analysis, 2 heat pipes of the same geometries but fill charge rates of 7, 30% were manufactured and submitted to operating tests. Comparison of experimental results on heat transfer rate show a fairly good agreement with the analytical results. The analysis reveals that the optimum charge ratio is ranged in 4~7% depending on the quantity of thermal loads. but the heat pipe with 7% of fill charge ratio reached dry-out limitation at heat flux of $q^{{\prime}{\prime}}=6.2kW/m^2$ lower than that of analytic results. Transition of flow regime was well related to the correlation by Semena & Khmelev on transient centrifugal Froude Number Frc. But hysteresis phenomenon was observed in transition of flow regime, when the rotational speed was stepwisely changed in the way to undergo 1 cycle.

추이대(推移帶)를 중심으로 한 경상북도 3개 도시의 열섬 평가 (Evaluation of the heat island in transition zone of three cities in Kyungpook, Korea)

  • 박인환;장갑수;김종용
    • 환경영향평가
    • /
    • 제8권2호
    • /
    • pp.73-82
    • /
    • 1999
  • This study analyzed the relationship between NDVI(Normalized Difference Vegetation Index) and urban heat island in three cities: Daegu, Kyungju, and Pohang for understanding the degree of nature conservation concentrating in the transition zone of them. Daegu city is the third city in Korea which has a dense population. Kyungju is a traditional city which has good nature. Pohang is an industrial city which has those of characters of Daegu and Kyungju. Landsat 1M data in May 17, 1997 were used for the analysis of heat island. There were about four theoretical models to estimate the surface temperature from TM data: Two-point linear model, Linear regression model, Quadratic regression model, and Cubic regression model. In this study, Linear regression model had been utilized to analyze the urban heat island. On the resultant images, the transition zone of Daegu was urbanized more extremely than those of other two cities. It is thought that the analysis of relationship between NDVI and surface temperature, used in this study, is regarded as one of effective methodologies for urban-environmental detection from satellite imageries.

  • PDF

열처리에 의한 TiO2 미립자의 상전이 (The Phase Transition of TiO2 fine Powders by Heat Treatment)

  • 김성종;장경환;변윤섭;진영철;정경락
    • 열처리공학회지
    • /
    • 제6권4호
    • /
    • pp.204-212
    • /
    • 1993
  • The preparation of $TiO_2$ fine particles from $TiCl_4$ and oxygen by the vapor-phasereaction was investigated at $850^{\circ}C$ with an emphasis on the effect of its experimental conditions on the crystal type of the products. Anatase $TiO_2$ particles prepared by experiment were used to study anatase-rutile transition by calcination temperature, the additives and gas atmosphere. The results were as follows. The kinetics of anatase-rutile transition was well agreed with A vrami equation, and the activation energy of transition was 35kcal/mol. The addition of CuO in anatase $TiO_2$ particles accelerated the anatase-rutile transition, and its transition was retarded in vaccum.

  • PDF

초음속 이중 압축 램프의 앞전 곡률에 따른 천이 유동 해석 (TRANSITIONAL FLOW ANALYSIS OVER DOUBLE COMPRESSION RAMP WITH NOSE BLUNTNESS IN SUPERSONIC FLOW)

  • 신호철;사정환;박수형;변영환
    • 한국전산유체공학회지
    • /
    • 제20권4호
    • /
    • pp.36-43
    • /
    • 2015
  • Accurate prediction of supersonic transition is required for the heat transfer estimation over supersonic double compression ramp flows. Correlation-based transition models were assessed for a supersonic double ramp problem. Numerical results were compared with experimental data from RWTH Aachen University. A parametric study on the nose bluntness was performed using a selected transition model. As the nose bluntness increases, the boundary layer thickness is increased and the triple point of shock interactions moves downstream. The peak magnitude of the heat transfer is consequently decreased with the nose bluntness.

Effects of dry period length on milk production and physiological responses of heat-stressed dairy cows during the transition period

  • Dong-Hyun Lim;Da Jin Sol Jung;Kwang-Seok Ki;Dong-Hyeon Kim;Manhye Han;Younghoon Kim
    • Journal of Animal Science and Technology
    • /
    • 제65권1호
    • /
    • pp.197-208
    • /
    • 2023
  • The objective of this study was to investigate the effects of a traditional dry period (60 d) versus a no dry period (0 d) on the milk production, physiological response, and metabolic status of dairy cows exposed to heat stress during the transition period. Holstein dairy cows (n = 15) with similar expected calving dates were randomly assigned to two different dry period lengths: (1) no dry period (n = 7) and (2) a traditional dry period of 60 days (n = 8). All cows were studied from 8 weeks before expected calving to 10 weeks after calving and experienced heat stress during the transition period. The results showed that cows with no dry period decreased their milk yield in subsequent lactation, but compensated for the loss of milk yield accounted for by additional milk yield before calving. The energy balance at postpartum was improved in cows with no dry period compared to cows with a traditional dry period. There were no significant differences in the physiological response and blood metabolites at postpartum between the dry period lengths of dairy cows exposed to heat stress during the transition period. Taken together, our results showed that omitting the dry period improved the milk production and metabolic status of dairy cows exposed to heat stress during the transition period.

軟鋼 熔接熱影響部의 塑性變形擧動에 關한 硏究 II (A Study the Behavior of Plastic Deformation in Weld HAZ of Mild Steel)

  • 박창언;정세희
    • Journal of Welding and Joining
    • /
    • 제10권1호
    • /
    • pp.43-51
    • /
    • 1992
  • The plastic zone formed around a notch tip is important in analyzing the fracture toughness of structures and particularly weld cracks existed in the weld HAZ (heat affected zone) which produces local plastic deformation at the crack tip. Therefore, in order to analyze the fracture toughness in weld HAZ, it is necessary to investigate the new fracture toughness parameter $K_{c}$ $^{*}$ and critical plastic strain energy $W_{p}$ $^{c}$ according to the shape and size of the plastic zone. 1) If the temperature corresponding to $K_{c}$ $^{*}$=130kg-m $m^{-3}$ 2/ is determined, transition temperature $T_{tr}$ the magnitude of plastic zone size, and heat input change depending on the fracture toughness. The blunted amounts of the parent and weld HAZ show mild linear variation until .delta.=0.4mm and then increase very steeply there after. 2) The relation between the plastic strain energy( $W^{p}$ ) and transition temperature( $T_{*}$tr) in parent metal is more sensitive than that of weld HAZ. However, the plastic strain energy depends on the transition temperature, and thus the yield stress, .sigma.$_{ys}$ becomes an important parameter for plastic strain energy. 3) The critical plastic strain energy( $W_{p}$ $^{c}$ ) absorbed by the plastic zone at the notch tip indicated in case of parent metal: 60J/mm, in case of heat input(20KJ/cm): 75J/mm, in case of heat input(30KJ/cm); 50J/mmJ/mm.

  • PDF

The Review of Studies on Pressure Drop and Heat Transfer In Microchannels

  • Hwang, Yun-Wook;Kim, Min-Soo
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제13권1호
    • /
    • pp.51-60
    • /
    • 2005
  • This paper reviews the studies on the pressure drop and the heat transfer in microchannels. Although a lot of studies about the single-phase flow have been done until now, conflicting results are occasionally reported about flow transition from laminar flow to turbulent flow, friction factor, and Nusselt number. Some studies reported the early flow transition due to relatively greater wall effect like surface roughness, but the other studies showed that the flow transition occurred at the Reynolds number of about 2300 and the early flow transition might be due to less accurate measurement of the channel geometry. Also, there have been arguments whether the conventional relation based upon continuum theory can be applied to the fluid flow and the heat transfer in microchannels without modification or not. The studies about the two-phase flow in microchannels have been mostly about investigating the flow pattern and the pressure drop in rectangular channels using two-component, two-phase flow like air/water mixture. Some studies proposed correlations to predict two-phase flow pressure drop in microchannels. They were mostly based on Lockhart-Martinelli model with modification on C-coefficient, which was dependent on channel geometry, Reynolds number, surface tension, and so on. Others investigated the characteristics of flow boiling heat transfer in microchannels with respect to test parameters such as mass flux, heat flux, system pressure, and so on. The existing studies have not been fully satisfactory in providing consistent results about the pressure drop and the heat transfer in microchannels. Therefore, more in-depth studies should be done for understanding the fundamentals of the transport phenomena in the microchannels and giving the basic guidelines to design the micro devices.

안내덕트 내부 난류유동구조에 따른 열전달 특성변화 수치해석 (Numerical Study on Heat Transfer Characteristics of Turbulent Flow in Transition Duct)

  • 유근종;최훈기;최기림
    • 대한기계학회논문집B
    • /
    • 제35권9호
    • /
    • pp.923-932
    • /
    • 2011
  • 본 연구에서는 복합화력발전소 가스터빈 출구가스 안내덕트 내부의 가스유동장이 배열회수보일러 전열기구에 미치는 영향을 CFD기법을 이용하여 분석하였다. 안내덕트 내부 난류흐름의 경우, 유속의 편차가 크고 선회 효과 및 상승류 현상이 심한 특징을 가지고 있음으로 이와 같은 유동의 수치해석을 위해 2개 방정식 난류점성 모델 중 RNG k-${\epsilon}$ 모델을 사용하였으며 유동장의 영향을 가장 많이 받는 배열 회수보일러 최종과열기관의 열전달특성변화를 파악하기 위하여 NTU 방식을 이용한 수치해석결과와, 산업계에서 적용하는 설계기법에 의한 결과를 비교하였다.

이상 유동 비등 시 마이크로 채널에서의 열전달 특성과 유동양식 조사 (Heat transfer characteristic and flow pattern investigation in micro-channels during two-phase flow boiling)

  • 최용석;임태우
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제39권7호
    • /
    • pp.696-701
    • /
    • 2015
  • 본 연구에서는 깊이 0.2 mm, 폭 0.45 mm, 길이 60mm 그리고 채널의 개수는 15개인 마이크로 채널에서 이상 유동비등에 관한 실험을 수행하였다. 작동유체로는 FC-72가 사용되었으며, 실험은 질량유속과 열유속 각각 $200-400kg/m^2s$, $5-40kW/m^2$ 범위와 증기 건도 0.1-0.9 범위에서 수행되었다. 열전달 계수는 낮은 열유속에서는 급격하게 감소하였으며, 일정 열유속 이상에서는 거의 일정하게 유지되었다. 측정된 열전달 계수로부터 기존의 방법을 이용하여 기포류, 슬러그류, 천류 그리고 파형/환상류의 유동양식으로 분류하였다. 또한 분류한 유동양식의 결과를 파형/환상류 영역으로의 천이 기준과 비교하였다. 하지만 기존의 천이 기준으로는 본 연구의 실험결과를 만족스럽게 예측하지 못하였다.