• 제목/요약/키워드: Heat of cure

검색결과 152건 처리시간 0.027초

승온 반응속도식을 이용한 LED용 실리콘 렌즈의 경화 및 열전달해석 (Cure and Heat Transfer Analysis in LED Silicone Lens using a Dynamic Cure Kinetics Method)

  • 송민재;김권희;홍석관;박정연;이정원;윤길상
    • 소성∙가공
    • /
    • 제24권2호
    • /
    • pp.101-106
    • /
    • 2015
  • Recently, silicone is being used for LED chip lens due to its good thermal stability and optical transmittance. In order to predict residual stresses, which cause optical birefringence and mechanical warpage of silicone, a finite element analysis was conducted for the curing of silicone during molding. For the analysis of the curing process, a dynamic cure kinetics model was derived based on the results of a differential scanning calorimetry (DSC) testing and applied to the material properties for finite element analysis. Finite element simulation results showed that a step cure cycle reduced abrupt reaction heat and showed a decrease in the residual stresses.

중합조건에 따른 dual cured resin cement의 열분석적 연구 (THERMAL ANALYSIS OF THE DUAL CURED RESIN CEMENTS ACCORDING TO CURING CONDITION)

  • 이인복;정관희;엄정문
    • Restorative Dentistry and Endodontics
    • /
    • 제24권2호
    • /
    • pp.265-285
    • /
    • 1999
  • The purposes of this investigation were to observe the reaction kinetics of five commercial dual cured resin cements (Bistite, Dual, Scotchbond, Duolink and Duo) when cured under varying thicknesses of porcelain inlays by chemical or light activation and to evaluate the effect of the porcelain disc on the rate of polymerization of dual cured resin cement during light exposure by using thermal analysis. Thermogravimetric analysis(TGA) was used to evaluate the weight change as a function of temperature during a thermal program from $25{\sim}800^{\circ}C$ at rate of $10^{\circ}C$/min and to measure inorganic filler weight %. Differential scanning calorimetry(DSC) was used to evaluate the heat of cure(${\Delta}H$), maximum rate of heat output and peak heat flow time in dual cured resin cement systems when the polymerization reaction occured by chemical cure only or by light exposure through 0mm, 1mm, 2mm and 4mm thickness of porcelain discs. In 4mm thickness of porcelain disc, the exposure time was varied from 40s to 60s to investigate the effect of the exposure time on polymerization reaction. To investigate the effect on the setting of dual cured resin cements of absorption of polymerizing light by porcelain materials used as inlays and onlays, the change of the intensity of the light attenuated by 1mm, 2mm and 4mm thickness of porcelain discs was measured using curing radiometer. The results were as follows 1. The heat of cure of resin cements was 34~60J/gm and significant differences were observed between brands (P<0.001). Inverse relationship was present between the heat of reaction and filler weight % the heat of cure decreased with increasing filler content (R=-0.967). The heat of reaction by light cure was greater than by chemical cure in Bistite, Scotchbond and Duolink(P<0.05), but there was no statistically significant difference in Dual and Duo(P>0.05). 2. The polymerization rate of chemical cure and light cure of five commercially available dual cured resin cements was found to vary greatly with brand. Setting time based on peak heat flow time was shortest in Duo during chemical cure, and shortest in Dual during light cure. Cure speed by light exposure was 5~20 times faster than by chemical cure in dual cured resin cements. The dual cured resin cements differed markedly in the ratio of light and chemical activated catalysts. 3. The peak heat flow time increased by 1.51, 1.87, and 3.24 times as light cure was done through 1mm, 2mm and 4mm thick porcelain discs. Exposure times recommended by the manufacturers were insufficient to compensate for the attenuation of light by the 4mm thick porcelain disc. 4. A strong inverse relationship was observed between peak heat flow and peak time in chemical cure(R=0.951), and a strong positive correlations hip was observed between peak heat flow and the heat of cure in light cure(R=0.928). There was no correlationship present between filler weight % or heat of cure and peak time. 5. The thermal decomposition of resin cements occured primarily between $300^{\circ}C$ and $480^{\circ}C$ with maximum decomposition rates at $335^{\circ}C$ and $440^{\circ}C$.

  • PDF

열경화성 수지의 온도에 따른 경화도와 비열(Cp) 변화 (The Change of Degree of Cure and Specific Heat Capacity According to Temperature of Thermoset Resin)

  • 신동우;황성순;이호성;김진원;최원종
    • Composites Research
    • /
    • 제28권3호
    • /
    • pp.99-103
    • /
    • 2015
  • 본 논문에서는 복합재료 제조공정 중 온도에 따른 경화 반응을 이해하고 열분석을 수행하였으며, 이 결과를 바탕으로 온도에 따른 수지의 경화도 및 비열의 변화를 수식화하였다. 온도에 따른 경화도와 비열은 DSC와 MDSC (Modulated DSC)를 활용하여 측정하였다. DSC와 MDSC 분석은 Isothermal과 Dynamic 조건으로 수행하여 Cure Kinetics, 유리전이온도 및 비열을 측정하고, 회기 분석 방법을 이용하여 물성거동을 수학적으로 모델링하였다.

레진기초상의 적합도에 관한 연구 (A STUDY ON THE FITNESS OF THE RESIN RECORD BASE)

  • 지재선;한상훈;오상천;조혜원
    • 대한치과보철학회지
    • /
    • 제34권3호
    • /
    • pp.611-619
    • /
    • 1996
  • The purpose of this study was to evaluate the fitness of 4 kinds of resin record base materials. The record base materials used on the edentulous cast in this study were Triad VLC resin (Dentsply International Inc., U.S.A.), custom tray resin (Kerr Ltd., U.S.A.), heat-cure resin (Dentimex Co., Holland), and self-cure resin (Dentimex Co., Holland). The gap width between record base and cast were measured in the ridge crest and midpalatal area with microhardness tester. The results obtained were as follows : 1. Among the 4 kinds of record base, heat-cure Vertex fitted best on the cast. Triad and Fomatray fitted better than self-cure Vertex. Self-cure Vertex had the poorest fit. 2. The quality of the fit of the record base varied at different locations on the cast. The record base fit better in the ridge crest than midpalatal area. 3. In the midpalatal area, there's no significant difference in the fit of Fomatray, Triad and heat-cure Vertex. They all fit better than self-cure Vertex. 4. In the ridge crest, heat-cure Vertex fit better than any other record base.

  • PDF

Study on Heat Resistance Anaerobic Adhesive Which Expands When Post Cured

  • Zhai, Haichao;Li, Yinbai;Lin, Xinsong
    • 접착 및 계면
    • /
    • 제3권1호
    • /
    • pp.9-12
    • /
    • 2002
  • In this paper, N,N-m-phenyenedimaleimide (m-PDM), Polyamide Resin (PI) and Metallic dimethacrylate etc. influencing the heat resistance of anaerobic adhesive has been studied, an anaerobic adhesive composition capable of post-cure expansion and $230^{\circ}C$ temperature resistance comprising a multifunctional methacrylate and m-PDM capable of effectuating expansion upon post-cure has been developed. A homogeneous mixture of a monomer and m-PDM are subjected to a first cure heat stage (Room Temperature) wherein a rigid partially-cured plastic is formed and a post-cure heat stage ($150^{\circ}C$) to effectuate permanent expansion of cured adhesive composition.

  • PDF

Effect of adhesive primers on bonding strength of heat cure denture base resin to cast titanium and cobalt-chromium alloy

  • Kim, Su-Sung;Vang, Mong-Sook;Yang, Hong-So;Park, Sang-Won;Lim, Hyun-Pil
    • The Journal of Advanced Prosthodontics
    • /
    • 제1권1호
    • /
    • pp.41-46
    • /
    • 2009
  • STATEMENT OF PROBLEM. The poor chemical bonding of a denture base resin to cast titanium framework often introduces adhesive failure and increases microleakage. PURPOSE. This study evaluated the shear bond strengths of a heat cure denture base resin to commercially pure titanium, Ti-6Al-4V alloy and a cobalt-chromium alloy using two adhesive primers. MATERIAL AND MATHODS. Disks of commercially pure titanium, Ti-6Al-4V alloy and a cobalt-chromium alloy were cast. Specimens without the primer were also prepared and used as the controls. The shear bond strengths were measured on a screw-driven universal testing machine. RESULTS. The primers significantly(P < .05) improved the shear bond strengths of the heat cure resin to all metals. However, the specimens primed with the Alloy $primer^{(R)}$(MDP monomer) showed higher bond strength than those primed with the MR $bond^{(R)}$(MAC-10 monomer) on titanium. Only adhesive failure was observed at the metal-resin interface in the non-primed specimens, while the primed specimens showed mixed failure of adhesive and cohesive failure. CONCLUSIONS. The use of appropriate adhesive metal primers makes it possible not only to eliminate the need for surface preparation of the metal framework before applying the heat cure resins, but also reduce the need for retentive devices on the metal substructure. In particular, the Alloy $primer^{(R)}$, which contains the phosphoric acid monomer, MDP, might be clinically more acceptable for bonding a heat cure resin to titanium than a MR $bond^{(R)}$, which contains the carboxylic acid monomer, MAC-10.

광중합 복합레진에 대한 가열처리 피로내성 및 중합수축에 미치는 영향 (A Fatigue Toughness and Polymerization Shrinkage of Post-cure Heat Treated Composite Resins)

  • 오원만;류선열;손호현;리이치 오쿠다;다쓰오 엔도;요시유키 쿠도
    • Restorative Dentistry and Endodontics
    • /
    • 제19권1호
    • /
    • pp.135-147
    • /
    • 1994
  • This study was conducted to evaluate whether the fatigue toughness of visible light cured composite resins could be improved and how much percentage of polymerzation shrinkage could be affected by additional heat treatment. 7 materials were investigated for this study: P-50, Lite-fil CR inlay, Pekafil, Clearfil CR inlay, Clearfil photo posterior, Z -100 and Progress. Diametral tensile strengths and linear shrinkages of composite resins were taken under visible light cured and additional post-cure heated condition and compared each other. A fatigue toughness of above materials was evaluated by measuring diametral tensile strength after they were repeatedly loaded with 120kgf/$cm^2$ up to 3000 cycles. The results obtained were as follows : 1. When composite resins were cured just by visible light, Lite fil CR inlay, Z -100 and Progress showed respectively higher diametral tensile strength than the other materials. Clearfil CR inlay, Clearfil photo posterior and Progress exhibited strong fatigue toughness compared to P-50 and Pekafil. 2. Post-cure heat treated composite resins had higher diametral tensile strengths than visible light cured composite resins at fatigue toughness test as well as no fatigue toughness test. 3. When Composite resins were additionally polymerized by post-cure heat treatment, P-50 showed weak fatigue toughness, on the contrary, Clearfil CR inlay, Z-100, Progress showed strong one. 4. When composite resins were cured just by visible light, percentage of polymerization linear shrinkage was the lowerest in Clearfil CR inlay, followed by, in ascending order, Clearfil photo posterior, Lite-fil CR inlay, Progress, Pekafil, P-50, and Z-100. In the case of post- cure heat treated composite resins, percentage of linear shrinkage was the lowest in Clearfil photo posterior, followed by, in ascending order, Lite-til CR inlay, Clearfil CR inlay, Progress, P-50, Pekafil and Z-100. 5. Percentage of polymerization linear shrinkage was greater in the post-cure heat treated composite resins than in the visible light cured composite resins and linear shrinkage increased significantly in Pekafil, Clearfil CR inlay, and Clearfil photo posterior between at the visible light cured and at the post-cure heat treated condition. The above results is saying that additional post-cure heat treatment on the composite resins for posterior restoration is able to affect on improvement of strength and fatigue toughness and lead to increase polymerization of composite resins.

  • PDF

불포화 폴리에스터 수치의 고온경화특성 연구 (High Temperature Cure Behavior of Unsaturated Polyester Resin)

  • 김형근;오제훈;이대길
    • 한국복합재료학회:학술대회논문집
    • /
    • 한국복합재료학회 2000년도 추계학술발표대회 논문집
    • /
    • pp.38-41
    • /
    • 2000
  • High temperature cure characteristics of polyester resin systems were investigated by isothermal and dynamic differential scanning calorimetries. During isothermal scanning, the experimental procedure was modified to reduce the initial Boss of heat. no kinetic equation from the isothermal experiment was compared with that from the dynamic experiment.

  • PDF

일정온도 상승률 열분석법을 이용한 수지 경화 모델 개발 (A New Cure Kinetic Model Using Dynamic Differential Scanning Calorimetry)

  • 엄문광;황병선
    • 연구논문집
    • /
    • 통권29호
    • /
    • pp.151-162
    • /
    • 1999
  • In general, manufacturing processes of thermosetting composites consist of mold filling and resin cure. The important parameters used in modeling and designing mold filling are the permeability of the fibrous preform and the viscosity of the resin. To consolidate a composite, resin cure or chemical reaction plays an essential role. Cure kinetics. Therefore, is necessary to quantify the extent of chemical reaction or degree of cure. It is also important to predict resin viscosity which can change due to chemical reaction during mold filling. There exists a heat transfer between the mold and the composite during mold filling and resin cure. Cure kinetics is also used to predict a temperature profile inside composite. In this study, a new scheme which can determine cure kinetics from dynamic temperature scaning was proposed. The method was applied to epoxy resin system and was verified by comparing measurements and predictions.

  • PDF

LED Encapsulation 실리콘의 기포잔류방지를 위한 Step 경화공정 연구 (A multi Step Cure Process to Prevent Residual Bubbles in LED Encapsulation Silicone Resin)

  • 송민재;김흥규;윤길상;김권희
    • 소성∙가공
    • /
    • 제21권2호
    • /
    • pp.101-106
    • /
    • 2012
  • Generally, rapid cure reaction of LED encapsulation silicone resin causes serious defects in cured resin products such as warpage, residual bubbles, and reduced wettablility. In order to prevent residual bubbles in silicone resin, the step cure process was examined in the present paper. Three kinds of step cure processes were applied, and bubble-free phenomenon was observed. Most of the bubbles were removed under $70^{\circ}C$, the minimum temperature for activating cure reaction. In addition, degree of cure(DOC) and temperature distribution were predicted by using FEM analysis of heat transfer. It was concluded that maintaining cure temperature which provide a DOC under 0.5~0.6 effectively reduces residual bubbles.