• 제목/요약/키워드: Heat load

검색결과 1,728건 처리시간 0.027초

유한요소법을 이용한 유기압 현수장치의 열전달 해석 (Heat Transfer Analysis of Hydropneumatic Suspension Unit By Finite Element Method)

  • 배징도;조진래;이홍우;송정인;이진규
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 춘계학술대회
    • /
    • pp.531-536
    • /
    • 2004
  • In-arm type hydropeumatic suspension unit(ISU) is an equipment of armed tracked vehicle to absorb impact load and vibration from the irregular ground. During the operation of ISU, main piston moves forward and backward and oil flowing through damper transmits the external impact load to floating piston. Heat is generated in ISU by the oil pressure drop through the damper orifice and the friction between cylinder wall and two pistons. On the other hand, internal heat dissipatis outside via heat convection. Occurrence of high temperature can deteriorate durability of major components and basic function of ISU. And, it can cause fatal problem in the ISU life time and the sealing performance of piston rings. As well, the spring constant change of nitrogen gas that is caused by the temperature rise exerts the negative effect to the vehicle stability. Therefore, in this paper, we analyze the heat transfer analysis of the entire ISU unit, by finite element method, with the outside flow velocities 8m/s and 10m/s.

  • PDF

지열히트펌프의 도심 열섬 저감 효과의 검토 (Effect of the Geothermal Heat-pump on alleviation of the Urban Heat Island)

  • 손원득
    • 한국태양에너지학회 논문집
    • /
    • 제36권3호
    • /
    • pp.45-52
    • /
    • 2016
  • Remarkable air temperature increases in urban areas are known as heat island phenomenon. In this study, we analyzed the effects of renewable energy on the heat island phenomenon in urban area by numerical method. The results showed that the use of renewable energy reduces the building energy use in urban area and contributes the alleviation of the Urban Heat Island Effects.

외기온도 변화에 따른 지역난방 공동주택 다중 열공급제어 알고리즘 개발에 관한 해석적 연구 (A Study on the Development of a Multi-Heat Supply Control Algorithm in a District Heating Apartment Building in Accordance with the Variation of Outdoor Air Temperature)

  • 변재기;윤성호;남기훈;최영돈;신종근
    • 설비공학논문집
    • /
    • 제25권11호
    • /
    • pp.585-594
    • /
    • 2013
  • In this study, we developed a heat supply control algorithm that minimizes the heat loss in the heat distribution pipelines used for supplying heat energy to shared group housing. Controlling the temperature and flow rate of the hot water supplied to the heat exchanger for shared group housing enables us to develop a heat supply control technique that meets the heating load required by each household in a shared apartment building in accordance with changes in the outdoor air temperature, and that minimizes the heat loss occurring in the heat distribution pipeline. A one-year study in 2008 on a 1,473-household D-apartment building in Hwaseong, Gyeonggi-do, South Korea, compared the heat capacity used by each household, as well as the heat capacity supplied to the heat exchanger room of the apartment housing building, to calculate the amount of heat loss in the heat distribution pipeline. The results confirmed that 24.1% of the heat supplied was lost in the piping.

반도체 클린룸용 배기 열회수식 외기공조시스템의 에너지절감에 관한 실험적 연구 (An Experimental Study on Energy Reduction of an Exhaust Air Heat Recovery Type Outdoor Air Conditioning System for Semiconductor Manufacturing Clean Rooms)

  • 송근수;유경훈;강신영;손승우
    • 설비공학논문집
    • /
    • 제21권5호
    • /
    • pp.273-281
    • /
    • 2009
  • In recent semiconductor manufacturing clean rooms, the energy consumption of outdoor air conditioning systems represents about 45% of the total air conditioning load required to maintain a clean room environment. Meanwhile, there is a large amount of exhaust air from a clean room. From an energy conservation point of view, heat recovery from the exhaust air is therefore useful for reducing the outdoor air conditioning load for a clean room. In the present work, an energy-efficient outdoor air conditioning system was proposed to reduce the outdoor air conditioning load by utilizing an air washer to recover heat from the exhaust air. The proposed outdoor air conditioning system consisted mainly of a preheating coil, an air washer, two stage cooling coils, a reheating coil, a humidifier and two heat recovery cooling coils inserted into the air washer and connected to a wet scrubber. It was shown from the lab-scale experiment with outdoor air flow of $1,000\;m^3/h$ that the proposed system was more energy-efficient for the summer and winter operations than an outdoor air conditioning system with a simple air washer.

기상자료와 냉난방 실측자료를 이용한 열부하 추정과 예측: 다계층모형의 활용 (Estimation and Prediction of the Heat Load Profile Using Weather and Heating/Cooling Data : An Application of the Multilevel Model)

  • 문춘걸;김수덕
    • 자원ㆍ환경경제연구
    • /
    • 제16권4호
    • /
    • pp.803-832
    • /
    • 2007
  • 새로운 접단에너지 사업에 대한 경제성 평가와 기존 집단에너지 시설의 최적운용을 위해서는 적어도 시간대 단위로 계측된 세부용도별 에너지 부하패턴에 관한 정보가 필수적이다. 본 연구에서는 기상자료와 냉난방 실측자료를 활용하여 열부하를 추정 예측하기 위하여 다계층모형을 선태하였다. 다계층모형은 수집한 자료의 패널자료 특성을 유연하게 모형화할 수 있는 이점이 있다. 다계층모형을 일대일의 대응관계에 있는 선형혼합효과모형으로 변환한 후 패널 FGLS(연산가능한 일반화최소자승추정법)를 적용하여 세부용도별로 열부하모형을 추정하였다. 추정된 부하모형은 온도, 습도, 시간대, 요일, 설날연휴/추석연휴 등 법정공휴일 특성, 난방면적/냉방면적이 열에너지사용량에 미치는 영향을 고려하고 있다. 지면을 고려하여 본 논문에서는 가정용 난방부하모형의 추정치와 난방부하곡선의 예측치에 제한하여 실증결과를 설명하고 있다.

  • PDF

Study on load tracking characteristics of closed Brayton conversion liquid metal cooled space nuclear power system

  • Li Ge;Huaqi Li;Jianqiang Shan
    • Nuclear Engineering and Technology
    • /
    • 제56권5호
    • /
    • pp.1584-1602
    • /
    • 2024
  • It is vital to output the required electrical power following various task requirements when the space reactor power supply is operating in orbit. The dynamic performance of the closed Brayton cycle thermoelectric conversion system is initially studied and analyzed. Based on this, a load tracking power regulation method is developed for the liquid metal cooled space reactor power system, which takes into account the inlet temperature of the lithium on the hot side of the intermediate heat exchanger, the filling quantity of helium and xenon, and the input amount of the heat pipe radiator module. After comparing several methods, a power regulation method with fast response speed and strong system stability is obtained. Under various changes in power output, the dynamic response characteristics of the ultra-small liquid metal lithium-cooled space reactor concept scheme are analyzed. The transient operation process of 70 % load power shows that core power variation is within 30 % and core coolant temperature can operate at the set safety temperature. The second loop's helium-xenon working fluid has a 65K temperature change range and a 25 % filling quantity. The lithium at the radiator loop outlet changes by less than ±7 K, and the system's main key parameters change as expected, indicating safety. The core system uses less power during 30 % load power transient operation. According to the response characteristics of various system parameters, under low power operation conditions, the lithium working fluid temperature of the radiator circuit and the high-temperature heat pipe operation temperature are limiting conditions for low-power operation, and multiple system parameters must be coordinated to ensure that the radiator system does not condense the lithium working fluid and the heat pipe.

복사 차폐막이 극저온 용기의 부하에 미치는 영향에 관한 실험적 연극 (An Experimental Study on the Effects of a Radiation Shield on the Thermal Load of a Cryochamber)

  • 김영민;박성제;강병하
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2005년도 동계학술발표대회 논문집
    • /
    • pp.365-370
    • /
    • 2005
  • Infrared (lR) detectors are widely used for such applications as thermoelstic stress analysis, medical diagnostics and temperature measurement. Infrared detectors commonly need to be refrigerated below 80 K, and thus a cooling system should be equipped together with the detector system. The cooling load, which should be removed by the cooling system to maintain the nominal operating temperature of the detector, critically depends on the insulation efficiency of the cryochamber housing the detector. Cryochamber considers the conduction heat transfer through a cold finger, the gases conduction and radiation heat transfer. The thermal loads of an infrared detector Cryochamber with radiation shield are investigated experimentally in present study. Since the effect of radiation heat transfer on thermal loads is significant, radiation shields is installed in the cold finger part to protect heat input through radiation. It is found that the thermal load can be substantially reduced by increasing the number of radiation shield.

  • PDF

건물 부하계산 프로그램을 이용한 외단열 시공의 에너지 절감 효과 분석 (Analysis of the Energy Saving Effect for the External Insulation Construction by Building Load Calculation Method)

  • 박재중;명제민;송두삼
    • 설비공학논문집
    • /
    • 제29권3호
    • /
    • pp.97-104
    • /
    • 2017
  • Reinforcement of insulation in apartment buildings reduces the heating and cooling energy consumption by lowering the heat transfer in the building envelope. There are differences between internal and external insulation methods in heat transmission properties. However, some building load calculation programs cannot analysis the differences between the two. This is because these programs do no account for the timelag or thermal storage effect of the wall according to the location of insulation. In this study, the heat transmission characteristics of internal and external insulation were analyzed by EnergyPlus, and heating and cooling energy demand was compared. The results showed that external insulation system had lower heating and cooling loads than internal insulation system. Also the heat transfer rate of external insulation is steadier than internal insulation. About 13.6% of heating and cooling energy demand decreased when the outdoor wall was finished with external insulation compared to the demand with internal insulation.

복사 차폐막이 설치된 극저온 용기의 열부하 특성에 관한 실험적 연구 (An Experimental Study on the Thermal Load of a Cryochamber with Radiation Shields)

  • 김영민;강병하;박성제
    • 설비공학논문집
    • /
    • 제20권1호
    • /
    • pp.11-16
    • /
    • 2008
  • Infrared (IR) detectors are widely used for such applications as thermoelastic stress analysis, medical diagnostics and temperature measurement. Infrared detectors commonly need to be refrigerated below 80 K, and thus a cooling system should be equipped together with the detector system. The cooling load, which should be removed by the cooling system to maintain the nominal operating temperature of the detector, critically depends on the insulation efficiency of the cryochamber housing the detector. Thermal load of a cryochamber is attributed to the conduction heat transfer through a cold finger, the gases conduction and radiation heat transfer. The thermal loads of an infrared detector cryochamber with a radiation shield are investigated experimentally in present study. Since the effect of radiation heat transfer on thermal loads is significant, radiation shields is installed in the cold finger part to protect heat input through radiation.

고정확도의 인공위성 궤도 열하중 계산 기법 (High Fidelity Calculation of Thermal Load in a Satellite Orbit)

  • 김민기
    • 한국항공우주학회지
    • /
    • 제45권10호
    • /
    • pp.898-906
    • /
    • 2017
  • 본 논문은 우주선의 우주궤도 상에서 받는 외부 열원을 효과적이고 정확하게 계산할 수 있는 방법에 대해 논한다. 우주 외부 열원은 크게 태양직사광, 지구반사광, 지구복사열 세가지로 구분할 수 있다. 본 논문은 지구반사광과 지구복사열이 확산반사 및 방사를 따른다고 가정하고 지구표면을 다수의 구역들로 분할하여 이들과 인공위성 표면과의 반사/복사열을 계산하여 합산하였다. 본 연구에는 이들의 엄밀 적분식을 적용하여 수렴성을 극대화하였으며 많은 경우 정확한 결과를 가져올 수 있음을 알 수 있다. 그리고 외부 열원과 위성 표면 사이의 광선 차폐를 판단하기 위해 KD Tree Ray Tracing을 적용한 인공위성 궤도 열하중 계산 알고리즘을 개발하였다.