• 제목/요약/키워드: Heat island effect

검색결과 209건 처리시간 0.022초

옥상녹화의 온도조절효과에 적합한 세덤류 분석 (The Analysis of Sedum Suitable for the Effect of Modulability the Temperature of the Rooftop Greening)

  • 이빛나라;김예슬;이은희
    • 한국환경복원기술학회지
    • /
    • 제18권2호
    • /
    • pp.53-64
    • /
    • 2015
  • Rooftop greening is the alternative of urban heat island. The purpose of this study is selecting Sedum to the effect of temperature reduction of the rooftop greening. Since the state of growth is excellent, Sedum kamtschaticum, Sedum takesimense and Sedum middendorffianum surveyed as coverage. It was investigated that there is the effect of reducing the temperature. The effect of temperature reduction of Sedum counted compound was found to be associated with state of growth. When you construct a rooftop greening, planting Sedum kamtschaticum, Sedum takesimense and Sedum middendorffianum is helpful to the effect of temperature reduction. Also, the ingredients various types of Sedum in order to reduce the effective temperature, it must be densified. It must demonstrate an additional effect of temperature reduction of Sedum through complementary and continuous monitoring of the future temperature monitoring method.

기후변화에 따른 벚꽃 개화일의 시공간 변이 (Climate Change Impact on the Flowering Season of Japanese Cherry (Prunus serrulata var. spontanea) in Korea during 1941-2100)

  • 윤진일
    • 한국농림기상학회지
    • /
    • 제8권2호
    • /
    • pp.68-76
    • /
    • 2006
  • A thermal time-based two-step phenological model was used to project flowering dates of Japanese cherry in South Korea from 1941 to 2100. The model consists of two sequential periods: the rest period described by chilling requirement and the forcing period described by heating requirement. Daily maximum and minimum temperature are used to calculate daily chill units until a pre-determined chilling requirement for rest release is met. After the projected rest release date, daily heat units (growing degree days) are accumulated until a pre-determined heating requirement for flowering is achieved. Model calculations using daily temperature data at 18 synoptic stations during 1955-2004 were compared with the observed blooming dates and resulted in 3.9 days mean absolute error, 5.1 days root mean squared error, and a correlation coefficient of 0.86. Considering that the phonology observation has never been fully standardized in Korea, this result seems reasonable. Gridded data sets of daily maximum and minimum temperature with a 270 m grid spacing were prepared for the climatological years 1941-1970 and 1971-2000 from observations at 56 synoptic stations by using a spatial interpolation scheme for correcting urban heat island effect as well as elevation effect. A 25km-resolution temperature data set covering the Korean Peninsula, prepared by the Meteorological Research Institute of Korea Meteorological Administration under the condition of Inter-governmental Panel on Climate Change-Special Report on Emission Scenarios A2, was converted to 270 m gridded data for the climatological years 2011-2040, 2041-2070 and 2071-2100. The model was run by the gridded daily maximum and minimum temperature data sets, each representing a climatological normal year for 1941-1970, 1971-2000, 2011-2040, 2041-2070, and 2071-2100. According to the model calculation, the spatially averaged flowering date for the 1971-2000 normal is shorter than that for 1941-1970 by 5.2 days. Compared with the current normal (1971-2000), flowering of Japanese cherry is expected to be earlier by 9, 21, and 29 days in the future normal years 2011-2040, 2041-2070, and 2071-2100, respectively. Southern coastal areas might experience springs with incomplete or even no Japanese cherry flowering caused by insufficient chilling for breaking bud dormancy.

Landsat 위성영상을 활용한 재건축 지역의 지표 온도 변화에 관한 연구 : 서울특별시 강동구의 고덕동과 둔촌동을 중심으로 (A Study on Land Surface Temperature Changes in Redevelopment Area Using Landsat Satellite Images : Focusing on Godeok-dong and Dunchon-dong in Gangdong-gu, Seoul)

  • 한지훈;손철
    • 한국지리정보학회지
    • /
    • 제26권2호
    • /
    • pp.42-54
    • /
    • 2023
  • 우리나라 대도시 지역에 인구가 집중되고 이에 따른 수요를 충족시키기 위하여 저밀도 주거지가 재개발·재건축을 통하여 고밀도 주거지화 되고 있다. 그러나 단시간에 이루어진 대규모의 재건축은 도시녹지 면적 감소에 의한 열섬현상을 발생시키는 등 도시 기후에 부정적인 영향을 끼치게 된다. 본 연구에서는 Landsat 8 위성영상을 활용하여 서울특별시 강동구 고덕동, 둔촌동 재건축 지역의 2013년에서 2022년까지의 지표 온도의 변화를 분석하였다. 고덕동 지역에서는 재건축이 진행되는 대상지와 산림지역, 산림과 시가지가 혼재된 지역, 저층주거지역에 대한 지표 온도의 차이를 분석하였으며, 둔촌동 지역에서는 대상지와 산림지역, 저층주거지역에 대한 지표 온도의 차이를 분석하였다. 분석은 지표 온도 차이에 대한 다중회귀분석을 통하여 진행되었다. 고덕동 지역과 둔촌동 지역에서 공통적으로 재건축 전단계까지 전반적으로 지표 온도가 산림보다 높고 저층주거지역보다 낮게 나타났다. 이러한 특징들은 고덕동, 둔촌동의 저층주거지역이 대상지보다 녹지율이 낮고 건폐율이 높기 때문에 발생하였음을 알 수 있다. 본 연구를 통해 저밀도 지역이 고밀도화가 되더라도 녹지와 건폐율을 적절하게 관리한다면 도시열섬현상을 완화시킬 수 있음을 알 수 있다.

도시의 건폐율 및 용적률이 도시기후에 미치는 영향 분석 (Analysis on the Effects of Building Coverage Ratio and Floor Space Index on Urban Climate)

  • 여인애;이정재;윤성환
    • 한국태양에너지학회 논문집
    • /
    • 제29권3호
    • /
    • pp.19-27
    • /
    • 2009
  • In this study, Urban Climate Simulation was performed by 3-Dimensional Urban Canopy Model. The characteristics of urban climate were analyzed combining artificial land coverage, building size, heat production from the air conditioning and topographic conditions as physical variables which affects urban climate characteristics. The results are as follows. (1) The aspects of the urban climatal change is derived to be related to the combination of the building coverage ratio, building height and shading area. According to the building height, the highest temperature was increased by $2.1^{\circ}C$ from 2-story to 5-story building and the absolute humidity by 2.1g/kg maximum and the wind velocity by 1.0m/s was decreased from 2-story to 20-story building. (2) Whole heat generation was influenced by the convective sensible heat at the lower building height and by the artificial heat generation at the higher one over 20-story building influence to some extent of the building coverage ratio. The effect of the altitude is not more considerable than the other variables as below $1^{\circ}C$ of the air temperature. In the last, deriving the combination of building coverage and building height is needed to obtain effectiveness of the urban built environment planning at the point of the urban climate. These simulation results need to be constructed as DB which shows urban quantitative thermal characters by the urban physical structure. These can be quantitative base for suggesting combinations of the building and urban planning features at the point of the desirable urban thermal environment as well as analyzing urban climate phenomenon.

CFD 시뮬레이션을 이용한 시설원예단지 여름철 외부 열환경 특성 및 개선방안 (A Characteristics and Improvement of Thermal Environment in Summer of Protected Horticulture Complex Using CFD Simulation)

  • 손진관;공민재;최덕규;강동현;박민정;윤성욱;이승철;이시영
    • 농촌계획
    • /
    • 제24권3호
    • /
    • pp.73-86
    • /
    • 2018
  • Agricultural or rural landscape provides various ecosystem services. However, the ecosystem services function is declining due to various environmental problems such as climate change, land use change, stream intensification, non-point pollution and garbage. The A1B scenario predicts that the mean air temperature of South Korea will rise $3.8^{\circ}C$ degrees celsius in 2100. Agricultural sector is very vulnerable to climate change, so it must be thoroughly predicted and managed. In Korea, the facility horticulture complex is 54,051ha in 2016 and is the 3rd largest in the world(MAFRA, 2014). Facilities of horticultural complexes are reported to cause problems such as groundwater decrease, vegetation and insects diversity reduction, landscapes damage and garbage increase, compared with the existing land use paddy fields. Heat island phenomenon associated with climate change is also accelerated by the high heat absorption of horticultural sites. Therefore, we analyzed the heat island phenomenon occurring in the facility of horticultural complex in Korea. As an improvement measurement, I examined how much air temperature is reduced by putting the channel and the open space. In the case of the Buyeo area, the Computational Fluid Dynamics (CFD) simulation was analyzed for the average summer temperature distribution in the current land use mode at $38.9^{\circ}C$. As an improvement measurement, CFD simulation after 10% of 6m water channel was found to have an effect of lowering the summer temperature of about $2.7^{\circ}C$ compared with the present average of $36.2^{\circ}C$. In addition, CFD simulations after analyzing 10% of the open space were analyzed at $34.7^{\circ}C$, which is $4.2^{\circ}C$ lower than the present. For the Jinju area, CFD simulations were analyzed for the average temperature of summer at $37.8^{\circ}C$ in the present land use pattern. As an improvement measure, CFD simulations after 10% of 6m water channel were found to have an effect of lowering the summer temperature of about $2.6^{\circ}C$ compared to the current average of $35.2^{\circ}C$. In addition, CFD simulations after analyzing 10% of the open space were analyzed at $33.9^{\circ}C$, which is $3.9^{\circ}C$ lower than the present. It can be said that the effect of summer temperature drop in open space and waterway has been proven. The results of this study are expected to be reflected in sustainable agriculture land use and used as basic data for government - level policy in land use planning for climate change.

냉기류를 이용하여 공동주택단지 내 지하주차장 오염농도를 저감하는 기후 디자인에 관한 연구 (A study on climate design using cold air flow to reduce air contaminant concentration of underground garage in the apartment complex)

  • 김태한;조경학;최지혜;김석철
    • KIEAE Journal
    • /
    • 제11권1호
    • /
    • pp.29-38
    • /
    • 2011
  • This study suggested practical application of climate design on apartment complex with the focus on the use of Cold Air Flow and green building design method. The domestic research on the wind path analysis has been associated since the early 21th century in urban planning and site planning, this initiative study aimed to mitigate the urban heat island effect and to promote the sustainable urban development. It is, however, mostly focused on the flow analysis and heat flow in the urban context, due to the poor application of the wind path analysis in actual planning and design. Special attention is paid to the possibilities of identifying and developing the application methods in relation to Cold Air Flow and building design. This study examined these relations and suggested some trenchant approach to a more comprehensive and efficient use of the wind flow analysis in climate design.

하절기 복사환경 관측을 통한 수목과 일사차폐 막 구조물의 자연냉각효과 (Analysis of Passive Cooling Effect of Membrane Shading Structure and the Tree by Field Observations in the Summer)

  • 최동호;이부용
    • 한국태양에너지학회 논문집
    • /
    • 제27권4호
    • /
    • pp.137-146
    • /
    • 2007
  • This study is about the passive cooling effects of three outdoor solar shading facilities as trees, pergola with wistaria vine and membrane shading structure, which are expected to provide cool spots in the summer. Field observations of measuring thermal environment of selected facilities is executed. Thermal environment measuring was categorized as short wave radiation, long wave radiation, net radiation, globe temperature, surface temperature measured by infrared camera. Heat transfer mechanism is analyzed with overall data from field measurement. Results from this study are as below; 1) Radiation balance measured on shaded surface under membrane shading structure was 17%($86W/m^2$) of the unshaded surface radiation balance($511W/m^2$). 2) Surface temperature comparison between vegetation and membrane of the shading structure is performed at 3 o'clock in the afternoon. Surface temperature of vegetation was same as air temperature and that of membrane was $5^{\circ}C$ higher than air temperature. Vegetation transpiration is considered as the causing factor which make those differences. 3) Results from this study could be used as fundamental data for reducing heat island phenomena and continuos research on this subject would be needed.

전면 식생형 보강토 옹벽의 표면온도 저감 효과 (Reduction Effect on Surface Temperature of Reinforced Soil Wall with Vegetated Facing)

  • 정성규;이광우;조삼덕;김주형
    • 한국지반환경공학회 논문집
    • /
    • 제14권12호
    • /
    • pp.53-60
    • /
    • 2013
  • 본 연구에서는 장기식생이 가능한 전면 식생형 보강토 옹벽의 식생 환경 적합성을 모니터링하고, 전면벽체 표면온도 측정을 통해 한여름철의 콘크리트 옹벽 전면벽체의 온도 변화를 평가하였다. 이를 위해 장기식생이 가능하도록 식생 포대를 삽입한 특수 블록 벽체를 시공하여 구절초, 맥문동을 포함한 20여 종의 종자 식재 후 2년간 식생 환경을 관찰하였을 뿐만 아니라, 실제 크기의 식생 옹벽을 건설하여 한여름철 식생 및 무식생 옹벽의 전면벽체 표면온도를 비교 분석하였다. 식생 환경 모니터링을 수행한 결과, 장기 식생이 가능한 블록 내에 식재된 대부분의 식물 생장 상태는 양호한 것으로 나타났으며, 식생 포대를 삽입한 블록 벽체가 식물의 성장에 적합한 환경을 제공하는 것으로 나타났다. 또한, 한여름철의 식생 옹벽과 무식생 옹벽의 콘크리트 블록 표면의 온도 변화량을 측정한 결과, 식생 옹벽에 비해 무식생 옹벽의 표면온도가 높게 나타났다. 식생 옹벽의 전면벽체의 경우, 무식생 옹벽의 전면벽체에 비해 표면온도 증가율이 작게 나타난 반면, 냉각율은 더 크게 나타나 장기식생이 가능한 전면 식생형 보강토 옹벽은 식생을 통해 열섬효과를 완화하는데 효과적으로 작용할 수 있을 것으로 판단된다.

아크릴 수지를 이용한 차열성 포장의 실내 및 현장 공용성 평가 (Laboratory and Field Performance Evaluation of Acryl Resin Based Solar Radiation Reflective Pavement)

  • 소경락;이현종;백종은;이상염
    • 한국도로학회논문집
    • /
    • 제13권4호
    • /
    • pp.19-28
    • /
    • 2011
  • 본 연구에서는 도심지 열섬현상을 완화 시킬 수 있는 아크릴 수지와 차열안료를 혼합한 차열성 포장을 개발하였다. 태양 복사열에 의한 포장체의 온도상승을 모사한 실내 시험으로부터 $60^{\circ}C$의 포장 온도에서 차열성 포장이 $12^{\circ}C$ 이상의 온도 저감 효과를 나타냈다. 이러한 온도 감소 효과는 차열안료의 배합비가 증가함에 따라 증가하였고, 반면에 점도의 증가로 인하여 작업성은 떨어졌다. 이러한 결과로부터 아크릴 수지 대비 차열안료의 최적혼합비율을 15%로 결정하였다. 차열성 포장의 칸타브로 손실률은 일반 배수성 포장의 손실률 1/4 수준으로 골재 비산 저항성이 우수하게 나타났다. 휠트랙킹 시험결과 차열성 포장의 동적안정도가 일반 배수성 포장에 비해 두 배 증가하였다. 차열성 포장재의 높은 부착력으로 인하여 탈리에 의한 손상 가능성은 낮은 것으로 나타났다. 시험 시공 구간에서의 소음도 측정 시험 결과 일반 배수성 포장에 비하여 평균 3.7dB의 소음저감 효과가 있었고, 미끄럼 저항치는 일반 배수성 포장에 비해서 평균 30% 정도 높아 우수한 미끄럼 저항성을 가지는 것으로 판단된다. 투수 시험 결과 차열성 포장의 투수성은 일반 배수성 포장보다 다소 작았으나 국내 배수성 포장 기준을 만족하는 것으로 나타났다.

유휴지를 활용한 최적의 도시 녹지 공간 탐색 - 녹지연결성과 열 환경 개선을 목적으로 - (Exploration of Optimal urban green space using unused land - To improve green connectivity and thermal environment -)

  • 김은섭;이동근;윤은주;박채연
    • 한국환경복원기술학회지
    • /
    • 제22권5호
    • /
    • pp.45-56
    • /
    • 2019
  • Urban green areas are generally composed of relatively small and fragmented patches, but it is a critical factor for the quality of an urban environment. They have positive effects such as increasing green connectivity, reducing runoff, and mitigating urban heat. But, there is a lack of urban greening plans that consider the comprehensive effects of green space in real urban areas. To fill this gap in this literature, this study identifies a planning model that determines the optimal locations for maximizing green areas' multiple effects(e.g., heat mitigation and enhancement of connectivity) by using unused lots. This model also considers minimizing costs using meta-heuristic optimization algorithms. As a results, we finds 50 optimal plans that considers two effects within the limited cost in Nowon-gu. The optimal plans show the trade-off effect between connectivity, heat mitigation and cost. They also show the critical unused land lots for urban greening that are commonly selected in various plans. These optimal plans can effectively inform quantitative effectiveness of green space and their trade-off. We expect that our model will contribute to the improvement of green planning processes in reality.