• Title/Summary/Keyword: Heat index

Search Result 860, Processing Time 0.032 seconds

A Study about the Impact of Atmospheric Environmental Changes by Urban Development on Human Health (도시개발에 따른 대기환경 변화가 건강에 미치는 영향연구)

  • Kim, Jea-Chul;Lee, Chong-Bum;Cheon, Tae-Hun;Jang, Yun-Jung
    • Journal of Environmental Impact Assessment
    • /
    • v.19 no.1
    • /
    • pp.15-28
    • /
    • 2010
  • Because deterioration of air quality and urban heat island directly harm health of citizens, Health Impact Assessment (HIA) and Environmental Impact Assessment (EIA) for urban development projects needs to conduct analysis of their impacts objectively. This study aims to review appropriate methods for assessment of air quality used at each stage of urban development and to investigate prediction and assessment methods of urban heat island. In addition, by evaluating impacts of climate change following supposed urban construction performed in the central area of Korea on public health, it examines usefulness of HIA for urban construction. When urban heat island prediction and HIA method suggested in this study are applied to an imaginary city, they predict urban heat island properly and the impacts of climate changes on public health inside the city could be determined clearly by calculating life-climate index and bio-climate index related with thermal environment from the model.

Dynamic performance analysis of flat plate solar collector system according to weather conditions and capacity of heat storage tank (기상조건과 축열조 용량에 따른 평판형 태양열 집열기 시스템의 동적 성능 해석)

  • Park, Bae-Duck;Kim, Gew-Deok;Kim, Kyoung-Hoon
    • Journal of the Korean Solar Energy Society
    • /
    • v.34 no.6
    • /
    • pp.57-65
    • /
    • 2014
  • Solar energy has attracted wide attention as a promising renewable energy source. The goal of this paper is to estimate the dynamic performance of solar flat plate collector system according to the weather conditions and the capacity of heat storage tank. This study provides a detailed description of the modeling methods and materials of the system. The effects of the daily clearness index and the volume of the heat storage tank on the hourly and daily performances of the system are numerically investigated. Special attention is focused on the important system variables including the solar insolation on the collector surface, useful energy, heat loss at the collector, and collector efficiency.

Preliminary Study on Usual Cold or Heat as a Risk Factor for Hypertension in an University Faculty (일개 대학 교직원 집단에서 고혈압의 위험요인으로서의 평소 한열 예비 연구)

  • Jung, Kyung Sik;Kim, Yun Young;Baek, Young Hwa;Jang, Eunsu
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.33 no.4
    • /
    • pp.226-232
    • /
    • 2019
  • This study was aimed to reveal that the usual cold or heat state was associated with hypertension and could be a risk. We emailed educational personnel in D university to join this study and 182 subjects participated in from March to December in 2016. The usual cold or heat diagnosis was conducted by two experts who had over 10 years expertise. The blood pressure was measured from the subjected after 10 minute rest with Jawon medical device. The hypertension was diagnosed by the guide of the Seventh Report of the Joint National Committee on Prevention, Detection, Evaluation, and Treatment of High Blood Pressure. The frequency analysis was used in general characteristics, Pearson's Correlation Coefficient analysis was conducted in among continuous variables, and chi-square test was also used between hypertension and cold or heat group. Logistic regression was analyzed to generate the odds ratios (ORs) and 95% confidence interval (CI) for hypertension. The cold score was suggested to have negative association with Body mass Index (BMI, -.374, p<.001), systolic blood pressure (-.333, p<.001), and diastolic pressure (-.261, p<.001). The heat score was analyzed to have positive association with Body mass Index (.413, p<.001), systolic blood pressure (.249, p<.001), and diastolic pressure (.156, p<.001). The distribution of the cold group (35.1%) and non-cold group (64.9%) in hypertension was significantly different (p=0.18). The distribution of the heat group (62.2%) and non-heat group (37.8%) was significantly different (p=0.27). The usual cold was associated with decreased ORs (ORs 0.405, 95% CI=0.191-0.857), and usual heat was associated with increased ORs (ORs 2.327, 95% CI=1.108-4.888). However, after adjusting body mass index, sex, and smoking, the association was not significantly different. It is possible that usual cold or heat associate with hypertension. Further study is needed to show that usual heat may be a independent risk factor for hypertension through follow up design.

Reological Studies on Cocoon Filament III. Stretching Strength and Elasticity Index of Cocoon Filament in Stretching Transformation (견사의 탄성적 성질에 관한 연구 III. 신장변형과정에 있어서의 인장강도 및 Elasticity Index에 대하여)

  • 남중희
    • Journal of Sericultural and Entomological Science
    • /
    • v.15 no.1
    • /
    • pp.31-35
    • /
    • 1973
  • Strength, elongation and elasticity are essential properties with regard to the tensile properties of raw silk thread. The reasonable harmony of the above three physical characters appears to be the specific nature of the raw silk thread and the dynamical functions are determined by the cocoon filament forming the raw silk. From such viewpoint, the author has studied the tensile property of the thread when the cocoon filament is stretched and transformed. The results obtained are as follows: 1) The stretching strength of the inner layer filament is stronger than that of the outer and medium layer ones. 2) The stretching strength of the filaments is influenced by the moisture-heat denaturalization of cocoon layer sericin in the drying process. 3) The more transformed functions by the stretching become, the lower the elasticity index of the cocoon filament was shown. 4) When cocoon layer sericin is denatured by moisture and heat, elasticity index of the filament is decreased.

  • PDF

Pre-detection Parameter of the Combustion Instabilities in the Gas Turbine Combustor (덤프형 가스터빈 연소기에서의 화염 불안정성의 사전 감지 인자)

  • Lee, Byeong-Jun;Santavicca, D.A.
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.26 no.5
    • /
    • pp.750-756
    • /
    • 2002
  • The effect of equivalence ratio and velocity on the stability of flame in dump combustor was studied in an atmospheric pressure, laboratory scathe dump combustor operating natural gas. Traditionally, peak-to-peak pressure, fluctuation of the heat release rate and Rayleigh index were used to find and control the combustion instability. Cross correlation coefficients, Ci,j which is defined as the normalized value of the integration of the product of two of the mixer pressure, dump plane pressure and heat release rate, are introduced to see whether the flame is stable or not. Ci,j shows more sensitive to combustion status than Rayleigh index in steadily burning flame. Also, the result indicates that the amplitude of Ci,j between heat release and mixer pressure goes up before the flame at the rich de-stabilizing equivalence ratio near $\psi$=0.85. t means Ci:j at this case has a potential to detect the de-stablizing moment in prior to becoming unstable in dump combustor.

Performance Analysis of R-1270(Propylene) Refrigeration System Using Internal Heat Exchanger (내부 열교환기를 이용한 R-1270용 냉동시스템의 성능 분석)

  • Ku, Hak-Keun
    • Journal of Power System Engineering
    • /
    • v.18 no.4
    • /
    • pp.36-42
    • /
    • 2014
  • This paper considers the influence of internal heat exchangers on the efficiency of a refrigerating system using R-1270. These internal heat exchangers(liquid-gas or suction-line heat exchangers) can, in some cases, yield improved system performance while in other cases they degrade system performance. A steady state mathematical model is used to analysis the performance characteristics of refrigeration system with internal heat exchanger. The influence of operating conditions, such as the mass flowrate of R-1270, inner diameter tube and length of internal heat exchanger, to optimal dimensions of the heat exchanger is also analyzed. The main results were summarized as follows : the mass flowrate of R-1270, inner diameter tube and length of internal heat exchanger, and effectiveness have the influences on the cooling capacity, compressor work and RCI(Relative Capacity Index) of this system. With a thorough grasp of it is possible to design the R-1270 compression refrigeration cycle using internal heat exchanger.

Study on the characteristics of nucleate boiling heat transfer with changing of surface roughness (표면거칠기의 변화에 따른 핵비등열전달의 특성에 관한 연구)

  • 김춘식;정대인;배종욱
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.7 no.1
    • /
    • pp.64-78
    • /
    • 1983
  • In nucleate boiling, bubbles are created by the expansion of entrapped gas or vapor at small cavities in the surface of heat transfer. Namely, surface roughness is the important factor of heat transfer. This paper deals with the characteristics of boiling curve according to surface roughness. Freon-113 is used as the experimental fluid. The results are as follows; 1. In the case of the same as "q=C$\Delta$T$^{n}$ ", the lower numberical index "n", the larger heat transfer coefficient and the lower wall superheat "$\Delta$T" is obtained for the rougher surface. 2. In the working of every kind of heat transfer sruface with boiling, improvement of capabilities of heat transfer can be devised by adding suitable roughness on the heat transfer surface. 3. When the metal nets of moderate mesh number are established, the capabilities of heat transfer can be improved in evaporation of liquid in vessels. But in the case that the sucession of bubbles in checked by using the nets which are too tight, the generation of bubbles union decreases critical heat flux. decreases critical heat flux.

  • PDF

The Effects of Dietary Turkish Propolis and Vitamin C on Performance, Digestibility, Egg Production and Egg Quality in Laying Hens under Different Environmental Temperatures

  • Seven, Pinar Tatli
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.21 no.8
    • /
    • pp.1164-1170
    • /
    • 2008
  • In this study, the effects of propolis and vitamin C (L-ascorbic acid) supplementation in diets were investigated on feed intake (FI), body weight (BW), body weight gain (BWG), feed conversion rate (FCR) and digestibility and on egg production and qualities (weight, mortality, shell thickness) in laying hens exposed to heat stress. A total of 150 Hyline White Leghorn, aged 42 weeks, hens was divided into five groups of 30 hens. Chicks were randomly divided into 1 positive control, 1 control and 3 treatment groups. The chicks were kept in cages in temperature-controlled rooms at $22^{\circ}C$ for 24 h/d (positive control, Thermoneutral, TN group) or $34^{\circ}C$ for 9 h/d from 08.00-17.00 h followed by $22^{\circ}C$ for 15 h (control, heat stress, HS group) and fed a basal diet or basal diet supplemented with vitamin C (250 mg/kg of L- ascorbic acid/kg of diet) or two levels of propolis (2 and 5 g of ethanol extracted propolis/kg of diet). Increased FI (p<0.05) and improvement in FCR (p<0.05), hen day egg (p<0.05) and egg weight (p<0.05) were found in Vitamin C and propolis-supplemented laying hens reared under heat stress conditions. Mortality rate was higher in the control group than TN, vitamin C and propolis groups (p<0.05). Digestibility of dry matter, organic matter, crude protein and ether extract improved with increasing of both dietary vitamin C and propolis (p<0.05). Vitamin C or propolis supplementation did not affect either the percentage shape index, yolk index or haugh unit and albumen index (p>0.05). However, the egg shell thickness and egg shell weight appeared to be increased in Vitamin C and propolis groups in comparison to HS group birds (p<0.05). In conclusion, dietary supplementation of laying hens with anti-oxidants (vitamin C and propolis) can attenuate heat stress-induced oxidative damage. These positive effects were evidenced by increased growth performance and digestibility, improvement of egg shell thickness and egg weight in comparison to non-supplemented birds. Moreover, supplementation with propolis (5 g/kg diet) was the most efficient treatment.

Heat tolerance in Brazilian hair sheep

  • Seixas, Luiza;Melo, Cristiano Barros de;Tanure, Candice Bergmann;Peripolli, Vanessa;McManus, Concepta
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.30 no.4
    • /
    • pp.593-601
    • /
    • 2017
  • Objective: The aim of this study was to evaluate heat tolerance using heat tolerance indices, physiological, physical, thermographic, and hematological parameters in Santa Ines and Morada Nova sheep breeds in the Federal District, Brazil. Methods: Twenty-six adult hair sheep, one and a half years old, from two genetic groups (Santa Ines: 12 males and 4 females; Morada Nova: 7 males and 3 females) were used and data (rectal temperature, respiratory rate, heart rate, skin temperatures; hematological parameters) were collected during three consecutive days, twice a day (morning and afternoon), with a total of six repetitions. Also physical parameters (biometric measurements, skin and hair traits) and heat tolerance indices (temperature-humidity index, Iberia and Benezra) were evaluated. The analyses included analyses of variance, correlation, and principal components with a significance level of 5%. Results: The environmental indices, in general, indicate a situation of thermal discomfort for the animals during the afternoon. Breed significantly influenced (p<0.001) physiological and physical characteristics of skin, hair, biometric measurements and Iberia and Benezra heat tolerance indices. Santa Ines animals were bigger and had longer, greater number and darker hair, thicker skin, greater respiratory rate and Benezra index and lower Iberia index compared with Morada Nova breed. Conclusion: Although both breeds can be considered adapted to the environmental conditions of the region, Morada Nova breed is most suitable for farming in the Midwest region. The positive correlation found between the thermographic temperatures and physiological parameters indicates that this technique can be used to evaluate thermal comfort. Also, it has the advantage that animals do not have to be handled, which favors animal welfare.

An Investigation on the Thermal Characteristics of Heat-Responsive Element of Sprinkler Head (스프링클러헤드 감열부의 열적 특성에 관한 연구)

  • You, Woo-Jun;Moon, Hyo-Jun;Youm, Moon-Cheon;Ryou, Hong-Sun
    • Fire Science and Engineering
    • /
    • v.26 no.3
    • /
    • pp.79-84
    • /
    • 2012
  • In this study thermal characteristics of heat-responsive element considering conduction, convection and rate of change of element using Response Time Index (RTI) applied to sensitivity test of sprinkler head at home and aborad are theoretically investigated. Analytic solution of temperature distributions with radial direction and time is obtained form energy transport equations, non-homogeneous 2th order partial differential equation, applying to constant wall temperature and symmetric condition in order to analyze thermal characteristics of heat-responsive element for circular cylindrical geometry. Base on the results, the analytic method of this study is fundamental data to practical use for sensitivity test of sprinkler head and design of heat-responsive element.