• Title/Summary/Keyword: Heat fluxes

Search Result 367, Processing Time 0.024 seconds

TEC를 이용한 인공위성 열제어 시스템의 특성 고찰

  • 김귀순;이수상;장영근;최해진
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 1999.04a
    • /
    • pp.24-24
    • /
    • 1999
  • This study addresses the effectiveness of TEC(Thermoelectric cooler) application for spacecraft thermal control. The required radiator area and power consumption characteristics of active thermal control using TEC are compared with the passive control at BOL and EOL through unsteady thermal analyses by calculating external heat fluxes. When the component operating temperature is low enough in TEC active control, the required radiator area can be smaller than the passive thermal control. TEC also needs less power consumption than the passive control under the condition that the temperature of cooling pars is low enough and/or the design temperature margin of the components is narrow enough.

  • PDF

Compensative Relationship Between Sensible and Latent Heat Fluxes in Surface Energy Partitioning (지표면 에너지 분배에서 현열과 잠열의 상보적인 움직임에 대한 고찰)

  • Kwanghun Choi;Kyungrock Paik
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2023.05a
    • /
    • pp.44-44
    • /
    • 2023
  • 지표면 위 에너지 수지, 즉 순 복사에너지가 어떤 비율로 지열, 현열, 잠열로 분할되는지를 이해하는 것은 매우 중요한 문제이지만, 에너지 분할과 주변 환경 변수 사이의 인과관계를 역학적으로 설명하는 것은 난제로 남아있다. 이 연구에서는 지표면 에너지 분할에서 어떠한 조건에서라도 보편적으로 발견되는 특성을 찾아서 다양한 식생 조건에서 관측된 복사에너지 및 열 플럭스 관측소의 자료를 토대로 각 에너지 항의 시간 변동성을 분석했다. 시계열 분석을 위해 공분산 기법을 통해 관측한 현열 및 잠열 자료를 제공하는 Fluxnet 자료를 사용했으며, International Geosphere-Biosphere Programme (IGBP) 구분법에 따라 낙엽수림, 상록수림, 농지 및 사바나에 위치한 관측소의 자료를 비교 분석했다. 모든 관측소에서 에너지 수지에서 현열과 잠열의 합이 전체 순 복사에너지에서 차지하는 비중은 시간에 따라 큰 변화를 보이지 않는다는 특성을 발견했다. 하지만, 현열 또는 잠열이 차지하는 비중은 큰 계절성을 보여주고 있었다. 이를 종합하면 현열과 잠열이 상호보완적으로 발생한다는 것을 의미한다. 한편 시간에 따른 두 열 플럭스의 움직임은 해당 관측소 근처에서 서식하는 식생 특성과 깊게 관련됐음을 확인했다.

  • PDF

Processing and Quality Control of Flux Data at Gwangneung Forest (광릉 산림의 플럭스 자료 처리와 품질 관리)

  • Lim, Hee-Jeong;Lee, Young-Hee
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.10 no.3
    • /
    • pp.82-93
    • /
    • 2008
  • In order to ensure a standardized data analysis of the eddy covariance measurements, Hong and Kim's quality control program has been updated and used to process eddy covariance data measured at two levels on the main flux tower at Gwangneung site from January to May in 2005. The updated program was allowed to remove outliers automatically for $CO_2$ and latent heat fluxes. The flag system consists of four quality groups(G, D, B and M). During the study period, the missing data were about 25% of the total records. About 60% of the good quality data were obtained after the quality control. The number of record in G group was larger at 40m than at 20m. It is due that the level of 20m was within the roughness sublayer where the presence of the canopy influences directly on the character of the turbulence. About 60% of the bad data were due to low wind speed. Energy balance closure at this site was about 40% during the study period. Large imbalance is attributed partly to the combined effects of the neglected heat storage terms, inaccuracy of ground heat flux and advection due to local wind system near the surface. The analysis of wind direction indicates that the frequent occurrence of positive momentum flux was closely associated with mountain valley wind system at this site. The negative $CO_2$ flux at night was examined in terms of averaging time. The results show that when averaging time is larger than 10min, the magnitude of calculated $CO_2$ fluxes increases rapidly, suggesting that the 30min $CO_2$ flux is influenced severely by the mesoscale motion or nonstationarity. A proper choice of averaging time needs to be considered to get accurate turbulent fluxes during nighttime.

Turbulent Dispersion Behavior of a Jet issued into Thermally Stratified Cross Flows (II) (열적으로 성충화된 횡단류에 분류된 제트의 난류확산 거동 (II))

  • Kim, Sang Ki;Kim, Kyung Chun
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.23 no.11
    • /
    • pp.1434-1443
    • /
    • 1999
  • The turbulent fluctuations of temperature and two components of velocity have been measured with hot- and cold-wires in the Thermally Stratified Wind Tunnel(TSWT). Using the fin-tube heat exchanger type heaters and the neural network control algorithm, both stable ($dT/dz=109.4^{\circ}C$) and unstable ($dT/dz=-49.1^{\circ}C$) stratifications were realized. An ambient air jet was issued normally into the cross flow($U_{\infty}=1.0 m/s$) from a round nozzle(d = 6 mm) flushed at the bottom waII of the wind tunnel with the velocity ratio of $5.8(U_{jet}/U_{\infty})$. The characteristics of turbulent dispersion in the cross flow jet are found to change drastically depending on the thermal stratification. Especially, in the unstable condition, the vertical velocity fluctuation increases very rapidly at downstream of jet. The fluctuation velocity spectra and velocity-temperature cospectra along the jet centerline were obtained and compared. In the case of stable stratification, the heat flux cospectra changes Its sign from a certain point at the far field because of the restratification phenomenon. It is inferred that the main reason in the difference between the vertical heat fluxes is caused by the different length scales of the large eddy motions. The turbulent kinetic energy and scalar dissipation rates were estimated using partially non-isotropic and isotropic turbulent approximation. In the unstable case, the turbulent energy dissipation decreases more rapidly with the downstream distance than in the stable case.

VARIABILITY OF THE LATENT HEAT FLUX DURING 1988-2005

  • Iwasaki, Shinsuke;Kubota, Masahisa
    • Proceedings of the KSRS Conference
    • /
    • 2008.10a
    • /
    • pp.289-292
    • /
    • 2008
  • Recently, several satellite data analyses projects and numerical weather prediction (NWP) reanalysis projects have produced the ocean surface Latent Heat Flux (LHF) data sets in the global coverage. Comparisons of these LHF data sets showed substantial discrepancies in the LHF values. Recently, the increase of LHF in during 1970s-1990s over the global ocean is shown by the LHF data that have been developed at the Objective Analyzed Air-Sea Fluxes (OAFlux) project. It is interesting to investigate the existence of the increase of LHF over a global ocean in the other LHF products. It is interesting to investigate the existence of the increase of LHF over a global ocean in the other LHF products. In this study, we assessed the consistencies and discrepancies of the inter-annual variability and decadal trend for the period 1988-2005 among six LHF products ((J-OFURO2, HOAPS3, IFREMER, NCEP1,2 and OAFlux) over the global ocean. As results, all LHF products showed a positive trend. In particular, the positive trend in satellite-based data analyses (J-OFURO2, HOAPS3, IFREMER) is larger than that in reanalysis products (NCEP1/2). Also, the consistencies and discrepancies are shown on the spatial patterns of the LHF trends across the six data sets. The positive trend of LHF is remarkable in the regions of western boundary currents such as the Kuroshio and the Gulf Stream in all LHF data sets. But, the discrepancies are shown on the spatial patterns of the LHF trends in tropics and subtropics. These discrepancies are primarily caused by the differences of the input meteorological state variables, particularly for the air specific humidity, used to calculate LHF.

  • PDF

Simulations of Thermal Stratification of Daecheong Reservoir using Three-dimensional ELCOM Model (3차원 ELCOM 모형을 이용한 대청호 수온성층 모의)

  • Chung, Se Woong;Lee, Heung Soo;Choi, Jung Kyu;Ryu, In Gu
    • Journal of Korean Society on Water Environment
    • /
    • v.25 no.6
    • /
    • pp.922-934
    • /
    • 2009
  • The transport of contaminants and spatial variation in a deep reservoir are certainly governed by the thermal structure of the reservoir. There has been continuous efforts to utilize three-dimensional (3D) hydrodynamic and water quality models for supporting reservoir management, but the efforts to validate the models performance using extensive field data were rare. The study was aimed to evaluate a 3D hydrodynamic model, ELCOM, in Daecheong Reservoir for simulating heat fluxes and stratification processes under hydrological years of 2001, 2006, 2008, and to assess the impact of internal wave on the reservoir mixing. The model showed satisfactory performance in simulating the water temperature profiles: the absolute mean errors at R3 (Hoenam) and R4 (Dam) sites were in the range of $1.38{\sim}1.682^{\circ}C$. The evaporative and sensible heat losses through the reservoir surface were maximum during August and January, respectively. The net heat flux ($H_n$) was positive from February to September, while the stratification formed from May and continued until September. Instant vertical mixing was observed in the reservoir during strong wind events at R4, and the model reasonably reproduced the mixing events. A digital low-pass filter and zero crossing method was used to evaluate the potential impact of wind-driven internal wave on the reservoir mixing. The results indicated that most of the wind events occurred in 2001, 2006, 2008 were not enough to develop persistent internal wave and effective mixing in the reservoir. ELCOM is a suitable 3D model for supporting water quality management of the deep and stratified reservoirs.

A study on thermal simulation for extensive green roof system using a plant canopy model (식생캐노피모델을 통한 저관리 조방형 옥상녹화시스템의 열해석 전산모의에 관한 연구)

  • Kim, Tae Han
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.15 no.2
    • /
    • pp.137-147
    • /
    • 2012
  • GRS is an effective urban ecology restoration technique that can manage a variety of environmental functions such as ecological restoration, rainwater spill control and island heat effect from a low-impact development standpoint that can be utilized in new construction and retrofits. Recently, quantitative evaluation studies, both domestic and abroad, in the areas related to these functions, including near-earth surface climate phenomenon, heavy rainwater regulation, thermal environment of buildings, have been actively underway, and there is a trend to standardize in the form of technological standards. In particular, centered on the advanced European countries, studies of standardizing the specific insulation capability of buildings with green system that comprehensively includes the green roof, from the perspective of replacing the exterior materials of existing buildings, are in progress. The limitation of related studies in the difficulties associated with deriving results that reflect material characteristics of continuously evolving systems due in part to not having sufficiently considered the main components of green system, mechanisms of vegetation, soils. This study attempts to derive, through EnergyPlus, the effects that the vegetation-related indicators such as vegetation height, FCV, etc. have on building energy load, by interpreting vegetation and soil mechanisms through plant canopy model and using an ecological standard indicator LAI that represent the condition of plant growth. Through this, the interpretations that assume green roof system as simple heat insulation will be complemented and a more practical building energy performance evaluation method that reflects numerical methods for heat fluxes phenomena that occur between ecology restoration systems comprised of plants and soil and the ambient space.

Flow Condensation Heat Transfer of R22, R134a, R407C, and R410A in Plain and Microfin Tubes (평관과 마이크로 핀관 내 R22, R134a, R407C, R410A의 흐름응축 열전달성능)

  • 조영목;박기호;송길흥;정동수
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.14 no.8
    • /
    • pp.656-663
    • /
    • 2002
  • Flow condensation heat transfer coefficients (HTCs) of R22, R134a, R407C, and R410A were measured on horizontal plain and microfin tubes. The experimental apparatus was composed of three main parts; a refrigerant loop, a water loop and a water/glycol loop. The test section in the refrigerant loop was made of both a plain and a microfin copper tube of 9.52 mm outside diameter and 1.0 m length. The refrigerant was cooled by passing cold water through an annulus surrounding the test section. Tests were performed at a fixed refrigerant saturation temperature of $40^{\circ}C$ with mass fluxes of 100, 200, and 300 kg/$m^2s$. Test results showed that at similar mass flux the flow condensation HTCs of R134a were similar to those of R22 for both plain and microfin tubes. On the other hand, HTCs of R407C were lower than those of R22 by 11~l5% and 23~53% for plain and microfin tubes respectively. And HTCs of R410A were similar to those of R22 for a plain tube but lower than those of R22 by 10~21% for a microfin tube. In general, HTCs of a microfin tube were 2.0~3.0 times higher than those of a plain tube.

Microclimate in Rice Nursery Bed Covered with Various Materials (벼 보온못자리 피복재질에 따른 상내 미기상 특성)

  • Hwang Kyu Hong;Lee Jeong Taek;Yun Jin Il;Shim Kyo Moon;Hur Seung Oh
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.2 no.3
    • /
    • pp.87-94
    • /
    • 2000
  • To recommend adequate covering materials and shapes of rice nursery bed for mechanical transplanting rice seedling, measuring of microclimate inside the rice nursery protected by polyethylene tunnel type, polyester tunnel type, and polyester flat type was compared to that outside the nursery. The vapor pressure deficit inside the polyester tunnel and polyethylene tunnel was higher than that outside the tunnel during daytime on a sunny day. During daytime on cloudy with rain day, the vapor pressure deficit inside polyester tunnel was higher than that in polyethylene tunnel or outside the nursery tunnel. The heat fluxes in the rice nursery tunnel during daytime flowed more to the soil than to the outside tunnel. Amounts of soil heat fluxes in polyethylene tunnel were higher than in polyester flat and polyester tunnel. The vertical profile of air temperature inside the nursery tunnel came to inversion during daytime and was lapse during nighttime regardless weather condition. The maximum temperature inside the nursery tunnel were 47.2$^{\circ}C$ in polyethylene tunnel and 37.$0^{\circ}C$ in polyester tunnel which was 21.1$^{\circ}C$ and 10.9$^{\circ}C$ higher than outside the tunnels respectively on sunny day. On cloudy with rain day, the temperature inside nursery tunnel was higher 8.4$^{\circ}C$ and 4.$0^{\circ}C$ polyethylene and polyester tunnel respectively then outside. Daily temperature changes became larger in the polyethylene tunnel, polyester tunnel, and outside the nursery tunnel in order. The rice seedling growth in polyester tunnel was better than the other nursery beds.

  • PDF

Prediction and Experiment of Pressure Drop of R22 and R134a on Design Conditions of Condenser (응축기의 설계조건에서 R22와 R134a의 압력강하 예측 및 실험)

  • Kang, Shin-Hyung;Byun, Ju-Suk;Kim, Chang-Duk
    • Journal of Energy Engineering
    • /
    • v.15 no.4 s.48
    • /
    • pp.243-249
    • /
    • 2006
  • An experimental study on the refrigerant-side pressure drop of slit fin an tube heat exchanger has been carried out. A comparison was made between the predictions of previously proposed empirical correlations and experimental data for the pressure drop on design conditions of condenser in micro-fin tube for R22 and Rl34a. Experiments were carried out under the conditions of inlet refrigerant temperature of $60^{\circ}C$ and mass fluxes varying from $150\;to\;250\;kg/m^{2}s$ for R22 and Rl34a. The inlet air conditions are dry bulb temperature of $35^{\circ}C$, relative humidity of 40% and air velocity varying from 0.68 to 1.43 m/s. Experiments show that pressure drop for R134a was $22{\sim}22.6%$ higher than R22 for the degree of subcooling $5^{\circ}C$ For the mass fluxes of $200{\sim}250\;kg/m^{2}s$, the deviation between the experimental and predicted values for the pressure drop was less than ${\pm}20%$ for R22 and Rl34a.