• 제목/요약/키워드: Heat flux meter

검색결과 48건 처리시간 0.019초

화염으로부터의 복사 열유속의 계측 I (A study on the measurement of Radiative Heat flux form the flame(I) -Design and Calibration of a Heat flux meter-)

  • 정종수;인종수;김승수
    • 대한기계학회논문집
    • /
    • 제14권2호
    • /
    • pp.484-491
    • /
    • 1990
  • A heat-flux meter has been designed and manufactured to measure the heat flux from the flame. A calibration method of the heat-flux meter by a calibration furnace has also been proposed. The k-type (Chromel-Alumel) thermocouple material has been used as the material for the beat-flux meter. The electormotive force (e.m.f.) from the K-type thermocouple is shown to be linearly proportional to the heat flux absorbed. The characteristics of the heat-flux meter become better as the radius of heat absorbing disk becomes larger and its thickness thinner.

금속스크랩이 혼합된 상변화물질의 유효열전도율 (Effective thermal conductivity of the phase change material with metal scrap)

  • 김시범;노승탁
    • 대한기계학회논문집
    • /
    • 제10권6호
    • /
    • pp.923-928
    • /
    • 1986
  • 본 논문에서는 열전도율이 큰 금속의 스크랩과 파라핀을 혼합한 축열 매질에 있어서 스크랩의 체적 혼합율에 따르는 열전도율의 변화를 모델링과 실험으로 구해서 축열 계산에 필요한 열전도율 자료를 제시하고자 한다.

이산화탄소가 수소 산소부화 화염의 열전달에 미치는 영향 (Effects of CO2 on Heat Transfer from Oxygen-Enriched Hydrogen Flame)

  • 이창엽;최준원;백승욱
    • 대한기계학회논문집B
    • /
    • 제28권8호
    • /
    • pp.937-944
    • /
    • 2004
  • An experimental study has been conducted to evaluate the effects of $CO_2$ on heat transfer from oxygen-enriched hydrogen flame. Experiments were performed on flames stabilized by a co-flow swirl burner, which was mounted on top of the furnace. Five different oxidizer compositions were prepared by replacing $N_2$ with $CO_2$. In a steady state, the total as well as radiative heat flux from the flame to the wall of furnace have been measured using a heat flux meter. Temperature distribution in furnace also has been measured and compared. By increasing $CO_2$ proportion in the oxidizer, the convection played a more significant role rather than radiation. Overall temperature in the furnace was seen to be decreased, while the total heat flux has increased.

냉장고 진공단열재 성능진단을 위한 열유속계 위치에 관한 연구 (A Study on the Heat Flux Meter Location for the Performance Test of a Refrigerator Vacuum Insulation Panel)

  • 하지수
    • 설비공학논문집
    • /
    • 제25권8호
    • /
    • pp.471-476
    • /
    • 2013
  • The present study has been carried out to elucidate the optimal method for the performance test of a refrigerator vacuum insulation panel (VIP), by using numerical heat transfer analysis. Three locations of heat flux meter have been tested, for deriving the best test method to clarify the normal or the abnormal condition of the vacuum insulation panel in a refrigerator. The first location of the heat flux sensor is at the same place as the heater, the second one is at the nearby side location of the heater and the third one is at the opposite side location of heater in the refrigerator. The heat flux and $1/q^{{\prime}{\prime}^2}$ or $q^{{\prime}{\prime}^4}$ were calculated for the cases with the normal VIP, and with the abnormal VIP, and their differences analyzed. From the present study, the first and the second method had a mere difference characteristics of heat flux and $1/q^{{\prime}{\prime}^2}$ or $q^{{\prime}{\prime}^4}$, between the cases with the normal or the abnormal VIP. The magnitude of the heat flux after 300sec had a great difference between the cases with the normal or abnormal VIP for the third method, and it could be considered the most optimal method to test the performance of a refrigerator vacuum insulation panel.

Measurement Methods of Latent Heat for PCM with Low Melting Temperature in Closed Tube

  • Hong Hiki;Kang Chaedong;Peck Jong Hyeon
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제12권4호
    • /
    • pp.206-213
    • /
    • 2004
  • Cycle test for developed phase change material (PCM) is necessary in order to assess the variation of latent heat, which decreases with time by deterioration. T-history method and measurement using heat-flux meter are appropriate for the cycle test in a tube filled with PCM because they do not need an extraction of sample in measuring heat of fusion. In the present study, these methods were applied to a PCM having a melting point below a room temperature, different to the past studies for PCMs melting above a room temperature. As a result of experiment using pure water as specimen, we can obtained rea-sonable values for heat of fusion.

밀폐튜브 내 저온 PCM의 잠열측정법 (Measurement Methods of Latent Heat for PCM with Low Melting Temperature in Closed Tube)

  • 류경용;박창현;백종현;홍회기
    • 설비공학논문집
    • /
    • 제15권7호
    • /
    • pp.604-610
    • /
    • 2003
  • Cycle test for developed phase change material (PCM) is necessary in order to analyze the variation of latent heat, which decreases with time by deterioration. 7-history method and measurement using heat flux meter are appropriate for the cycle test in a tube filled with PCM because they do not need an extraction of sample in measuring the heat of fusion. In the present study, these methods were applied to a PCM having a melting point below a room temperature, different from the past studies for PCMs melting above a room temperature. As a result of experiment using pure water as specimen, we can obtain reason-able values for heat of fusion by both methods.

이산화탄소가 수소 산소부화 화염의 열전달에 미치는 영향 (The Effects of $CO_2$ on Heat Transfer from Hydrogen Oxygen-enriched Flame)

  • 이창엽;최준원;백승욱
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 제26회 KOSCO SYMPOSIUM 논문집
    • /
    • pp.261-266
    • /
    • 2003
  • An experimental study has been conducted to evaluate the effects of $CO_{2}$ on heat transfer from hydrogen oxygen-enriched flame. Experiments were performed on flames stabilized by a co-flow swirl burner, which mounted on top of the furnace. Five composition conditions of oxidizer were chosen with replacing $N_{2}$ with $CO_{2}$. In a steady state, total and radiative heat flux rates from the flame to the wall of furnace has been measured using heat flux meters. Temperature distribution in furnace also has been checked. Increasing $CO_{2}$ ratio in the oxidizer, the dominant heat transfer mode was changed into convection from radiation. Temperature in the furnace decreased but total heat flux increased.

  • PDF

정상 및 비정상상태의 화재조건에서 판형 열유속계의 적용성에 관한 실험적 연구 (An Experimental Study on the Applicability of Plate Thermometer in Steady and Unsteady-State Fire Conditions)

  • 윤홍석;문선여;황철홍
    • 한국화재소방학회논문지
    • /
    • 제29권5호
    • /
    • pp.34-41
    • /
    • 2015
  • 정상 및 비정상상태의 화재조건에서 설치가 용이하고 저가형인 판형 열유속계(PT)의 적용성에 대한 실험적 연구가 수행되었다. 열원으로서 적외선 복사 히터와 C3H8이 적용된 정사각형 버너가 사용되었다. PT의 상대적 측정 정확도는 Gardon-type 열유속 미터를 이용한 측정결과와의 비교를 통해 평가되었다. 정상 및 비정상상태의 화재조건에서 PT의 최적 크기 및 두께는 측정 정확도와 실용적 관점에서 각각 100 mm와 0.6 mm로 확인되었다. 이 결과들은 PT의 크기 및 두께의 변화에 따른 전도 열손실과 열관성에 의해 설명되었다. 또한 Slow보다 빠른 화재 성장속도의 조건에서 PT를 이용한 열유속 측정에는 상당한 주의가 요구됨을 확인하였다.

실측실험과 3차원 정상상태 열전달 해석을 통한 발열유리의 온도 및 전열량 분석 (Analysis of Temperature and Total Heat of Heated Glass through Experimental Measurement and Three-Dimensional Steady-State Heat Transfer Analysis)

  • 이도형;윤종호;오명환
    • KIEAE Journal
    • /
    • 제15권1호
    • /
    • pp.111-116
    • /
    • 2015
  • Heat loss from windows and condensation occuring on its surface due to its lower insulation value causes much discomfort to occupants. In this study, Heated glass was used to make a basic study on prevention of condensation on glass surface for its heating functionality through experimental measurement and simulation analysis of total heat flux on the interior and exterior surface of glass. Error between experimental results and three dimensional steady-state heat transfer analysis were caused firstly, beacuse in the experimental chambers, cold chamber and steady temperature and humidity chamber, air temperature setting was not constant but rather ON/OFF control, and secondly, due to error rate in heat flux meter due to heat flux direction even in stable conditions.

수평관내 이산화탄소의 증발 열전달 특성 (Evaporative Heat Transfer Characteristics of Carbon Dioxide in a Horizontal Tube)

  • 손창효;이동건;김영률;오후규
    • 설비공학논문집
    • /
    • 제16권12호
    • /
    • pp.1134-1139
    • /
    • 2004
  • The evaporative heat transfer coefficient of $CO_2$ (R-744) in a horizontal tube was investigated experimentally. The experiments were conducted without oil in a closed refrigerant loop which was driven by a magnetic gear pump. The main components of the refrigerant loop are a receiver, a variable-speed pump, a mass flow meter, a pre-heater and evaporator (test section). The test section consists of a smooth, horizontal stainless steel tube of inner diameter of 7.75 mm. The experiments were conducted at mass flux of 200 to 500 kg/m$^2$s, saturation temperature of -5 to 5$^{\circ}C$, and heat flux of 10 to 40kW/m$^2$. The test results showed the heat transfer of $CO_2$ has a greater effect on nucleate boiling more than convective boiling. Mass flux of $CO_2$ does not affect nucleate boiling too much, and the effect of mass flux on evaporative heat transfer of $CO_2$ is much smaller than that of refrigerant R-22 and R-134a. In comparison with test results and existing correlations, correlations failed to predict the evaporative heat transfer coefficient of $CO_2$, therefore, it is necessary to develope reliable and accurate predictions determining the evaporative heat transfer coefficient of $CO_2$ in a horizontal tube.