• Title/Summary/Keyword: Heat flux balance equation

Search Result 24, Processing Time 0.025 seconds

The Response of soil surface heat budget to the precipitation (지표면 열수지의 강수응답성에 관한 연구)

  • 황수진;진병화
    • Journal of Environmental Science International
    • /
    • v.3 no.2
    • /
    • pp.89-100
    • /
    • 1994
  • It is very important to assess accurately the terms which are included in the heat budget equation of soil surface because they are used in the UM and miso-scale circulation modeling as well as in the micrometeorological studies. Each terms in the heat budget equation change according to the soil moisture content. So, it is necessary to specify clearly the relations between soil moisture content and these terms. Special experiment with micrometeorological measurements was executed to study these relations at Environmental Research Center of Tsukuba University, Japan. The results are as follow: 1. The soil moisture contents of 1 cm and 4 cm depth are oscillated with one day Period in drying process and the amplitude of variation of 1 cm depth is greater than that of 4 cm. 2. Increase in soil moisture contents due to precipitation result in decrease of albedo with step function. 3. Sensible heat is in reverse proportion to the soil moisture content and latent heat is in direct proportion to it. Latent heat is more sensitive than sensible heat according to the soil moisture variation. Net long wave radiation have high correlation with soil moisture. 4. Comparing with the radiative term with the flux term in wetting process due to precipitation, the energy transfer of the aero and thermodynamic flux is greater than that of the radiative heat flux.

  • PDF

Near-Wall Modelling of Turbulent Heat Fluxes by Elliptic Equation (타원방정식에 의한 벽면 부근의 난류열유속 모형화)

  • Shin, Jong-Keun;An, Jeong-Soo;Choi, Young-Don
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.28 no.5
    • /
    • pp.526-534
    • /
    • 2004
  • A new second-moment closure model for turbulent heat fluxes is proposed on the basis of the elliptic equation. The new model satisfies the near-wall balance between viscous diffusion, viscous dissipation and temperature-pressure gradient correlation, and also has the characteristics of approaching its respective conventional high Reynolds number model far away from the wall. The predictions of turbulent heat transfer in a channel flow have been carried out with constant wall heat flux and constant wall temperature difference boundary conditions respectively. The velocity field variables are supplied from the DNS data and the differential equations only fur the mean temperature and the scalar flux are solved by the present calculations. The present model is tested by direct comparisons with the DNS to validate the performance of the model predictions. The prediction results show that the behavior of the turbulent heat fluxes in the whole region is well captured by the present model.

An Improved Mechanistic Model to Predict Critical Heat Flux in Subcooled and Low Quality Convective Boiling

  • Kwon, Young-Min;Chang, Soon-Heung
    • Nuclear Engineering and Technology
    • /
    • v.31 no.2
    • /
    • pp.236-255
    • /
    • 1999
  • An improved mechanistic model was developed to predict a convective boiling critical heat flux (CHF) in the vertical round tubes with uniform heat fluxes. The CHF formula for subcooled and low quality boiling was derived from the local conservation equations of mass, energy and momentum, together with appropriate constitutive relations. The model is characterized by the momentum balance equation to determine the limiting transverse interchange of mass flux crossing the interface of wall bubbly layer and core by taking account of the convective shear effect due to the frictional drag on the wall-attached bubbles. Comparison between the present model predictions and experimental CHF data from several sources shows good agreement over a wide range of How conditions. The present model shows comparable prediction accuracy with the CHF look-up table of Groeneveld et al. Also the model correctly accounts for the effects of flow variables as well as geometry parameters.

  • PDF

Estimation Method of Evapotranspiration over Goheung bay Wetland (고흥만 습지에서 증발산량의 산출 방법)

  • KWON, Byung Hyuk;KIM, Dong Su;KIM, Geun Hoi;KANG, Dong Hwan
    • Journal of Wetlands Research
    • /
    • v.10 no.1
    • /
    • pp.21-30
    • /
    • 2008
  • Evapotranspiration is an important factor in the energy interaction process between the surface and the air. Over a vegetable canopy, evapotranspiration was investigated by measuring the sensible heat flux, the soil heat flux and the net radiation flux. Evapotranspiration based on routine AWS data is in good agreement with that estimated from the energy balance equation except for weak wind shear less than $1s^{-1}$ and a cloudy period. Soil heat flux can be approximately to 10% of net radiation flux at the lower layer. When the slope of the saturation vapor pressure versus temperature curve ($de_s/dT$) is approximated to 1.5, the evapotranspiration can be described in function of the net radiation energy flux over Goheung bay wetland covered with the vegetable canopy, reeds.

  • PDF

Airborne Remote Sensing of Evapotranspiration over Rice Paddy

  • Chen, Y.Y.;Liou, Yuei-An
    • Proceedings of the KSRS Conference
    • /
    • 2003.11a
    • /
    • pp.351-353
    • /
    • 2003
  • We present a retrieval scheme for the remote sensing of evapotranspiration (ET) over rice paddy. To perform the retrieval, high-resolution airborne imagery of multi-spectral visible and thermal infrared data, and ground-based meteorological measurements are utilized. Our ET retrieval scheme is based on the basic principal of surface energy budget, which is a result of balance in longwave and shortwave radiation, latent heat, sensible heat, and energy flux into the ground. To partition the latent and sensible heat fluxes of interest from the energy balance equation, three basic parameters are of most concern, including albedo, surface temperature, and normalized difference vegetation index (NDVI). The NDVI and albedo can be easily derived from the visible and near infrared spectral data, while the surface tem-perature can be determined through the analysis of the infrared data with the Stefan Boltzmann law. From the airborne imagery taken on 28 April 2003, we observe very good dry and wet pixels that can be easily corre-sponded to the radiation and evaporation controlled crite-ria, respectively, and, hence, for the further use in defin-ing the evaporative fraction needed to partition sensible and latent heat fluxes from the net energy flux. The de-rived ET is compared with the in situ measurements.

  • PDF

Estimation of Actual Evapotranspiration using Multi-Satellite Data over Korea Peninsula (다중 위성 자료를 이용한 한반도에서의 실제 증발산량 산출에 관한 연구)

  • Lee, Min-Ji;Han, Kyung-Soo;Kim, In-Hwan
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.19 no.4
    • /
    • pp.145-151
    • /
    • 2011
  • Evapotranspiration (ET) is an important process acrossa wide range of disciplines, including ecology, hydrology and meteorology.In this study, daily actual evapotranspiration (ETa) is based energy balance equation and considering high surface roughness length to estimate. This study was used variety of satellite data and ground observation data in Korea Peninsula from 1 January to 31 December 2009. In this study, sensible heat flux is one of the important parameters of ETa. Measurements of sensible heat flux are, however, complex and can't be easily obtained. So this study was used an empirical coefficient B to simplify estimate of sensible heat flux. The coefficient B in the ETa model requires a careful definition of aerodynamic resistance. So this study proposed ETa model considering aerodynamic resistance and high surface roughness length. This study was conducted validation in comparison of the proposed daily ETa results with Priestley-Taylor ETp.

An Experimental Study on Evaporative Heat Transfer Characteristics in a Small Diameter Tube (미소직경관 내 증발열전달 특성에 관한 실험적 연구)

  • Hwang, Yun-Uk;Kim, Min-Su
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.25 no.2
    • /
    • pp.216-224
    • /
    • 2001
  • Experiments have been performed to investigate evaporative heat transfer characteristics of R-134a flowing in a small diameter tube. Test section was made of stainless steel tube with an inner diameter of 2.2mm and was uniformly heated by electric current which was applied to the tube wall. The local saturation temperature of refrigerant flowing in a tube is calculated from the measured local saturation pressure by using an equation of state. Inner wall temperature was calculated from measured outer wall temperature, accounting for heat generation in the tube and one dimensional heat conduction through the tube wall. Mass quality of refrigerant flowing in a tube was calculated by considering energy balance in the pre-heater and the test section. Heat flux was varied from 19 to 64kW/$m^2$, and mass flux was chanted from 380 to 570kg/$m^2$s for each heat flux condition. From this study, heat transfer in a small diameter tube is affected by heat flux as well as mass flux for a wide range of mass quality. Heat transfer coefficient in a small diameter tube is much greater than that in medium sized tubes. Test results in this study are compared with Gungor and Winterton correlation, which gives an absolute average deviation of 27%.

Comparison of Two Methodsto Estimate Urban Sensible Heat Flux by Using Satellite Images (위성 영상을 활용한 두 가지 현열 플럭스 추정 방법 간의 비교)

  • Kim, Sang-Hyuck;Lee, Dong-Kun
    • Journal of Environmental Impact Assessment
    • /
    • v.31 no.1
    • /
    • pp.63-74
    • /
    • 2022
  • In orderto understand the urban thermal conditions, many studies have been conducted to estimate the thermal fluxes. Currently sensible heat fluxes are estimated through various methods, but studies about comparing the differences between each method are very insufficient. Therefore, this study try to estimate the sensible heat flux of the same area by two representative estimation methods and compare their results to confirm the significance and limitation between methods. As a result of the study, the heat balance methods has a great advantage in terms of resolution but it can not consider the anthropogenic heat flux, so sensible heat flux can be underestimated in urban areas. When estimating based on physical equation, anthropogenic heat flux can be considered and the error is relatively small, it has a limitations in time and space resolutons. The two methods showed the largest difference in industiral areas where anthropogenic heat fluxes are high, with an average of 135 W/m2 and a maximum of 400 W/m2. On the other hand, the green and water have a very small difference with and average of 20 W/m2. The results between two methods show significant differences in urban areas, it is necessary to select a suitable method for each research purpose.

A Fundamental Study of BIPV System Functioned as Solar Collector for Building Application (건물 적용을 위한 태양열 집열기 기능을 갖는 BIPV 시스템의 기초적 연구)

  • Min, Sung-Hye;Suh, Seung-Jik
    • Journal of the Korean Solar Energy Society
    • /
    • v.27 no.1
    • /
    • pp.91-98
    • /
    • 2007
  • Perimeter zone is one of the weakest area in buildings and it makes an increase of heating and cooling loads, in addition to condensation or discomfort with cold-draft to residents in winter. Because of this, it needs to be reinforced by active systems. However, they use fossil fuel, and ultimately greenhouse effect is urged. Thus, we proposed BIPV system functioned as solar collector which can substitute active system. As an fundamental stage, heat balance equation in steady-state by Fortran was used not only, in winter for pre-heating effect and electric power capacity during the day, but also in summer, for the latter during the day and sky radiation effect during the night. Especially, we should have considered shading on PV by IES Suncast, since even a little bit of it makes the efficiency too low for the PV modules to work. As a result, in summer day, the PV panel should be tiled in 70 degrees to gain the most electric power. Moreover, we could verify that this model makes higher temperature and heat flux under 0.02 m/s. On the other hand, the PV had the high efficiency with high velocity because of cooling effect behind the PV. Therefore, we should regard the air current distribution later on.

Application of BIPV System Functioned as Solar Collector (태양열 집열기 기능을 갖는 BIPV 시스템의 응용)

  • Min, Sung-Hye;Suh, Seung-Jik
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.953-958
    • /
    • 2006
  • Perimeter zone has been reinforced by active systems, such as fan-coil units, because it causes an increase in heating and cooling loads, dew condensation in winter, or discomfort with cold-draft to residents in buildings, through poor insulation by light-weighed skin due to progressing multi-storied buildings and skyscrapers. However, because these active systems raise Its capacity so that fossil fuel is used as much as they are added, and ultimately, greenhouse effect is urged, we proposed BIPV system functioned as solar collector which can substitute active system. As an early stage, heat balance equation in steady-state by Fortran was used not only for pre-heating effect and electric power capacity during the day in winter, but also for electric power capacity during day in slimmer and sky radiation effect during night in summer. Especially, we should have considered shading on PV, since even a little bit of it makes the efficiency too low for the PV to work. Still, when the flux of pre-heated air was increased to make air-barrier, its temperature was not enough to make it because the speed of heat exchange was too fast to warm up the air, thus the capacity to meet the condition was evaluated, and electric power from PV was made used for it.

  • PDF