• 제목/요약/키워드: Heat extraction rate

검색결과 56건 처리시간 0.028초

지중열원 열펌프 시스템의 난방성능 해석 (A Study on the Heating Performance of Ground Source Heat Pump System)

  • 우정선;김대기;이세균
    • 설비공학논문집
    • /
    • 제16권12호
    • /
    • pp.1175-1182
    • /
    • 2004
  • Installations of vertical boreholes for the ground source heat pump system are expensive to install. One way to reduce the initial cost is to increase the specific heat extraction rate of borehole system. However, as the specific heat extraction rate increases the temperature of borehole fluid decreases with the resultant lower Coefficient Of Performance in Heating(COPH) of heat pump system. The purpose of this study is to provide the basic informations about the performance of heat pump system with the specific heat extraction rate and soil thermal properties such as thermal conductivity and temperature. It is shown that the specific heat extraction rate is the most important parameter for the ground source heat pump system. To obtain the reasonable COPH value (COPH > 3) the heat extraction rate should be about 25 W/m or less. Accurate measurements of soil thermal properties are also very important to design the system properly. The effects of borehole thermal resistances are also examined in this study.

실측치를 통한 사무소건물 슬래브축열 공조시스템의 적정 축열시간 검토 (Consideration of Appropriate Thermal Storage Time of Air-Conditioning System with Slab Thermal Storage in an Office Building by Use of Measurement Value)

  • 정재훈
    • 설비공학논문집
    • /
    • 제22권10호
    • /
    • pp.719-726
    • /
    • 2010
  • In this paper, the appropriate thermal storage time of an air-conditioning system with slab thermal storage was considered by use of summer measurement values. Two standards of heat extraction rate and criterion function were established as the standard that evaluates appropriateness. When heat extraction rate was a standard, zero hour and seven hours were obtained as appropriate thermal storage time, in the case of evaluation by energy consumption and running cost individually. Also, when criterion function was a standard, the difference between energy consumption and running cost was small, it was because the weight function to room air temperature deviation was much bigger than heat extraction rate.

열펌프 건조기의 기본 설계를 위한 건조 성능 해석 (Drying Performance Simulation for the Basic Design of a Heat Pump Dryer)

  • 이공훈;김욱중
    • 대한기계학회논문집B
    • /
    • 제31권10호
    • /
    • pp.860-867
    • /
    • 2007
  • Heat pump drying has a great potential for energy saving due to its high energy efficiency in comparison with conventional air drying. In the present study, the performance simulation for the basic design of a heat pump dryer has been carried out. The simulation includes one-stage heat pump cycle, simple drying process using the drying efficiency. As an example, the heat pump cycle with Refrigerant 134a has been investigated. For the operating conditions such as the average temperature of the condenser, the heat rate released in the condenser, the flow rate of drying air, and drying efficiency, the simulation has been carried out to figure out the performance of the dryer. The parameters considered in the design of the dryer are COP, MER, SMER, the rate of dehumidification, the temperature and humidity of drying air and those parameters are compared for different conditions after carrying out the simulation.

지중열원 열펌프시스템의 성능해석 (A Study on the Performance of Ground Source Heat Pump System)

  • 이세균;우정선;노정근
    • 한국태양에너지학회 논문집
    • /
    • 제25권4호
    • /
    • pp.69-76
    • /
    • 2005
  • The performance of water-to-water heat pump system coupled with the ground source vertical heat exchanger is presented in this paper. The CAP program of Florida Heat Pump Co. is used to predict the heat pump performances while the EED program calculates the borehole fluid temperature. It is shown that COPH increases with decreasing the temperature of output water for the operation of heating mode and COPR increases with increasing temperature of output water for the operation of cooling mode. The value of specific heat extraction rate must be moderate to insure the reasonable installation cost of borehole system. With $1^{\circ}C$decrease of $T_{wo}$ the average COPH increase is estimated as about $0.06/^{\circ}C$(for $T_{wo}\;=\;45{\sim}60^{\circ}C$ range) while with $1^{\circ}C$ increase of $T_{wo}$ the estimation of COPR increase is about $0.13/^{\circ}C$(for $T_{wo}\;= \;5{\sim}11^{\circ}C$ range) at the specific heat extraction rate of 30W/m.

전기히터식 및 지열원 히트펌프식 농산물 열풍건조기의 에너지 성능 비교 (Energy Performance Comparison of Electric Heater and Geothermal Source Heat Pump type Agricultural Hot Air Dryers)

  • 양원석;김영일;박승태
    • 한국지열·수열에너지학회논문집
    • /
    • 제14권4호
    • /
    • pp.7-12
    • /
    • 2018
  • Energy performance of electric heater and geothermal source heat pump type hot air dryers are compared in this study. For set temperatures of $30^{\circ}C$, $35^{\circ}C$ and $40^{\circ}C$, radish is dried from initial mass 60 kg until it gets 5 kg, where the difference equals the amount of water removed. As set temperature is increased, drying time is shortened for both electric heater and heat pump types, however energy efficiency is decreased due to increasing electricity consumption. Moisture extraction rate(MER) of electric heater is 2.58~2.84 kg/h, and for heat pump type 2.56~2.71 kg/h, showing little difference between the two types. Specific moisture extraction rate (SMER) of electric heater is 0.94~0.96 kg/kWh, and for heat pump type 1.72~2.21 kg/kWh. SMER of heat pump type is greater by 0.78~1.25 kg/kWh than the electric heater hot air dryer, which is 1.8~2.3 times better in terms of energy efficiency.

순환 공기 유량의 변화를 고려한 열펌프 건조기의 성능 해석 (Analysis on the Drying Performance with the Flow Rate of Circulation Air in a Heat Pump Dryer)

  • 이공훈;김욱중;이상열
    • 설비공학논문집
    • /
    • 제21권1호
    • /
    • pp.1-8
    • /
    • 2009
  • The simulation of a heat pump dryer has been carried out to figure out the effect of air flow rate on the drying performance represented by MER, SMER, and so on. The simulation includes the analyses of one-stage heat pump cycle and simple drying process using the drying efficiency. The heat pump cycle with Refrigerant 134a has been considered. In the dryer, some of drying air from the drying chamber flows through the heat pump system, the rest of air bypasses the heat pump system. The two air flows joins before the drying chamber inlet. The performance parameters considered in the present study are MER, SMER, the temperature and humidity of drying air. Those parameters are compared for different total air flow rate or bypass air flow rate.

녹용 및 녹각의 단백질 가수분해 효소 및 염산에 의한 가용화 (Extraction of Young Antler and Antler by Water, Proteases and HCl)

  • 안용근
    • 한국식품영양학회지
    • /
    • 제17권2호
    • /
    • pp.147-155
    • /
    • 2004
  • 동결건조 녹용, 열건조 녹용, 녹각을 물, pretense, 염산으로 단계적으로 추출하였다. 5$0^{\circ}C$ 물로 추출한 경우 동결건조 녹용은 9.01%(흡광도 8.82), 열건조 녹용은 9.01%(흡광도 4.45), 녹각은 1.10%(흡광도 0.31)의 추출율을 나타냈고, 세균 protease로 추출한 경우는 동결건조녹용은 16.89%(흡광도 4.50), 열건조 녹용은 17.20%(흡광도 5.62), 녹각은 18.22%(흡광도 0.64)의 추출율을 나타냈고, 0.8N 염산으로 추출한 경우는 동결건조 녹용은 72.25%(흡광도 4.60), 열건조 녹용은 71.1%(흡광도 4.70), 녹각은 79.82%(흡광도 2.80)의 추출율을 나타냈다. 이들 삼단계 과정으로 동결건조 녹용은 98.15%, 열건조 녹용은 97.35%, 녹각은 99.14% 추출되었다. HPLC로 분석한 결과, 녹용 및 녹각추출물에서 나타나는 고분자 피크는 단백질 가수분해 효소의 작용으로 분자량 1,000 정도의 작은 피크로 분해되었고 남은 각질은 0.8 N염산에 의하여 분자량 7만 정도의 단백질이 추출되었다. 이상의 결과로부터 동결 건조녹용의 추출에는 물과 protease에 의한 추출, 열건조 녹용의 추출에는 protease와 염산에 의한 추출, 녹각의 추출에는 염산에 의한 추출이 효과적이었다.

지중 열교환기 설계를 위한 화강암의 열물성 연구 (Thermal Properties of Granite for Installation of Underground Heat Exchanger)

  • 김종찬;이영민;구민호
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2007년도 춘계학술대회
    • /
    • pp.456-459
    • /
    • 2007
  • Thermal conductivities (TC) of 57 Jurassic muscovitic granite samples (KIGAM) and 149 porphyritic granite samples (Yeonki: BE-2, BE-3) were measured with LFA-447. Ranges of TC values are $2.429{\sim}3.878$ W/mK (KIGAM), $2.220{\sim}3.767$ W/mK (Yeonki, BE-2) and $2.019{\sim}3.990$ W/mK (Yeonki, BE-3); arithmetic means are 2.924 W/mK (KIGAM), 2.907 W/mK (Yeonki, BE-2), and 2.881 W/mK (Yeonki, BE-3), respectively. In this study, harmonic mean values were calculated to estimate the average value of TC. Harmonic mean values are 2.883 W/mK (KIGAM), 2.886 W/mK (Yeonki, BE-2), and 2.866 W/mK (Yeonki, BE-3), respectively. Heat extraction rates of a borehole heat exchanger strongly depend on TC values. Heat-extraction rates from re values are expected to be a little lower than 84 W/m in all sites. However, considering ground water flow, it is expected that actual heat extraction rate would be higher than the expected value.

  • PDF

열펌프 건조 해석 모델을 이용한 측정 결과의 분석 (Investigation of Experimental Results Using the Drying Model for a Heat Pump Dryer)

  • 이공훈;김욱중;김종률;이상열
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회B
    • /
    • pp.2268-2273
    • /
    • 2008
  • The drying model has been used to obtain the fundamental information required to design the heat pump dryer with the simple thermodynamic model. In the model, the input conditions are crucial to obtain the acceptable results. The model includes one-stage heat pump cycle, simple drying process using the drying efficiency. The drying efficiency is defined with the conditions of inlet and outlet in the dryer. The experiment has been carried out in the pilot dryer with one-stage heat pump cycle. Refrigerant 134a is used in the heat pump cycle. In the dryer, some of drying air flows through the heat pump system and the rest of air bypasses the heat pump system and circulates through the drying chamber. Some operating conditions from the pilot dryer are used as input conditions of the model and the results are compared with experimental results for the validation.

  • PDF

토조 및 수치모형을 이용한 개방형 지중 열교환 시스템 모의 (Simulation of Open-Loop Borehole Heat Exchanger System using Sand Tank Experiment and Numerical Model)

  • 이성순;배광옥;이강근
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2007년도 추계학술대회 논문집
    • /
    • pp.489-492
    • /
    • 2007
  • Understanding the thermohydraulic processes in the aquifer is necessary for a proper design of the aquifer thermal energy utilization system under given conditions. Experimental and numerical test were accomplished to evaluate the relationship between the geothermal heat exchanger operation and hydrogeological conditions in the open-loop geothermal system. Sand tank experiments were designed to investigate the open-loop geothermal system. Water injection and extract ion system as open-loop borehole heat exchanger was applied to observe the temperature changes in time at injection well, extraction well and ambient groundwater. The thermohydraulic transfer for heat storage was simulated using FEFLOW for two cases of extraction and injection phase operation in sand tank model. As one case, the movement of the thermal plume was simulated with variable locations of injection and extraction well. As another case, the simulation was performed with fixed location of injection and extraction well. The simulation and experimental results showed that the temperature distribution depends highly on the injected water temperature and the length of injection time and the groundwater flow and pumping rate sensitively affect the heat transfer.

  • PDF