Abstract

Thermal conductivities (TC) of 57 Jurassic muscovitic granite samples (KIGAM) and 149 porphyritic granite samples (Yeonki: BE-2, BE-3) were measured with LFA-447. Ranges of TC values are $2.429{\sim}3.878$ W/mK (KIGAM), $2.220{\sim}3.767$ W/mK (Yeonki, BE-2) and $2.019{\sim}3.990$ W/mK (Yeonki, BE-3); arithmetic means are 2.924 W/mK (KIGAM), 2.907 W/mK (Yeonki, BE-2), and 2.881 W/mK (Yeonki, BE-3), respectively. In this study, harmonic mean values were calculated to estimate the average value of TC. Harmonic mean values are 2.883 W/mK (KIGAM), 2.886 W/mK (Yeonki, BE-2), and 2.866 W/mK (Yeonki, BE-3), respectively. Heat extraction rates of a borehole heat exchanger strongly depend on TC values. Heat-extraction rates from re values are expected to be a little lower than 84 W/m in all sites. However, considering ground water flow, it is expected that actual heat extraction rate would be higher than the expected value.

Keywords