• 제목/요약/키워드: Heat density

검색결과 1,955건 처리시간 0.029초

Effect of Heat Treatment Conditions and Densities on Residual Stresses at Hybrid (FLN2-4405) P/M Steels

  • Kafkas, Firat;Karatas, Cetin;Saritas, Suleyman
    • 한국분말야금학회:학술대회논문집
    • /
    • 한국분말야금학회 2006년도 Extended Abstracts of 2006 POWDER METALLURGY World Congress Part 1
    • /
    • pp.566-567
    • /
    • 2006
  • The characteristics of residual stresses occurring in PM steel based nickel (FLN2-4405) was investigated. The measurements of residual stresses were carried out by electrochemical layer removal technique. The values and distributions of residual stresses occurring in PM steel processed under various densities and heat treatment conditions were determined. In most of the experiments, tensile residual stresses were recorded in surface of samples. The residual stress distribution on the surface of the PM steels is affected by the heat treatment conditions and density. Maximum values of residual stresses on the surface were observed sinter hardened condition and $7.4\;g/cm^3$ density. Minimum level of recorded tensile residual stresses are150 MPa and its maximum level is 370 MPa.

  • PDF

구상흑연주철의 $CO_2$레이저 표면경화 특성 (The Characteristics of Ductile Cast Iron Heat-treated by $CO_2$Laser)

  • 정원기;전병철;김재도
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1997년도 춘계학술대회 논문집
    • /
    • pp.998-1002
    • /
    • 1997
  • This study has been performed to predict beam absorption with analysis of temperature field by using a FEM in co /sab 2/ laser hardening and to invesrigate into some effects of power density and travel speed of laser beam on the microstructure and hardness of ductile cast iron treated by laser surface hardening technique. Optical micrograph has shown that large martensite and small amount of retained austenite appear in inside hardened zone. Hardness measurement has revealed that the range of maximum hardness value is Hv=415 .+-. 10. The power density increases and the travel speed decreases, the depth of hardened zone increases due to increase of input power density.

  • PDF

NUMERICAL SOLUTION FOR WOOD DRYING ON ONE-DIMENSIONAL GRID

  • Lee, Yong-Hun;Kang, Wook;Chung, Woo-Yang
    • Journal of the Korean Society for Industrial and Applied Mathematics
    • /
    • 제11권1호
    • /
    • pp.95-105
    • /
    • 2007
  • A mathematical modeling for the drying process of hygroscopic porous media, such as wood, has been developed in the past decades. The governing equations for wood drying consist of three conservation equations with respect to the three state variables, moisture content, temperature and air density. They are involving simultaneous, highly coupled heat and mass transfer phenomena. In recent, the equations were extended to account for material heterogeneity through the density of the wood and via the density variation of the material process, capillary pressure, absolute permeability, bound water diffusivity and effective thermal conductivity. In this paper, we investigate the drying behavior for the three primary variables of the drying process in terms of control volume finite element method to the heterogeneous transport model on one-dimensional grid.

  • PDF

실리카 에어로겔의 상압합성 및 특성연구(II) (Synthesis of Silica Aerogel at Ambient Pressure and Characterization (II))

  • 권영근;최세영;강신규
    • 한국세라믹학회지
    • /
    • 제36권11호
    • /
    • pp.1189-1197
    • /
    • 1999
  • Low-density silica gel monolith was synthesized at ambient pressure by surface modification with TMCS and sub-sequent heat treatment. The mechanical thermal and optical properties of gel were studied. Compressive strength and modulus of compression of 350$^{\circ}C$-heated gel with the density of 0.24g/cm3 were 250kPa and 0.2MPa respectively. The thermal conductivity of silica gels synthesized at ambient pressure exhibited 0.02 W/m$.$K for the density of 0.24g/cm3 which is similar to that of the gel via supercritical drying and their main thermal transfer mechanism is considered to be solid and radiation conduction at room temperature. Ambient-dried silica gels were transparent blue showing about 60% of transmittance in the wavelength of 1500-2100nm and typical absorption bands of existing bonds under heat treatment at 350$^{\circ}C$. Medium scale monolity(${\Phi}$=50mm) at ambient pressure could be successfully prepared through total 5-month process period.

  • PDF

용융탄산염 연료 전지 스택의 성능 및 열전달 해석 (An Analysis on the Performance and the Heat Transfer of Molten Carbonate Fuel Cell Stack)

  • 구자용;서종철;김유
    • 설비공학논문집
    • /
    • 제6권2호
    • /
    • pp.120-129
    • /
    • 1994
  • A numerical investigation has been carried out for the electrochemical reaction, mass and heat transfer characteristics of the Molten Carbonate Fuel Cell(MCFC) stack. The effects of cooling air channel and water gas shift reaction were taken into account. The current density distribution of electrodes, the molecular fractions of reactant gasses and three dimensional temperature distribution can be calculated and shown by several lines of equivalent values. The results have been compared with the existing ones, and reasonable agreement has been obtained. To examine the influence of changing parameters, such as the composition of reactant gases, the target average current density, the utilization of reactant gases, the cooling air inlet temperature and flow rates, the computer simulation has been done. The analysis method and computer program developed in this study will be greatly helpful to design and verify the optimum operating condition of MCFC stack.

  • PDF

제상과정 해석을 위한 눈의 융해거동에 관한 수치적 연구 (Numerical Study on the Behavior of Snow Melting for the Analysis of Defrosting Procedure)

  • 이관수;박준상;김서영
    • 설비공학논문집
    • /
    • 제12권6호
    • /
    • pp.599-608
    • /
    • 2000
  • One dimensional numerical modeling was carried out for the melting behavior of dry snow and the unsaturated flow when heat was supplied from the bottom surface. Discrepancy between the previous experimental data and the present numerical results is substantially reduced by considering the density change of water permeation layer due to the infiltration of meltwater. In the parametric study for effective thermal conductivity, it was found that the effect of this parameter to the behavior of snow melting is minor. Sensitivity analysis showed that the melting time is most sensitive to changes in supplied heat flux, snow temperature, and bulk density, whereas snow bulk density and residual saturation have a significant effect on the height of water permeation layer in snow.

  • PDF

IGBT소자의 열적 안정성을 고려한 방열설계 (Thermal Design of IGBT Module with Respect to Stability)

  • 이준엽;송석현
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2002년도 추계학술대회 논문집
    • /
    • pp.205-208
    • /
    • 2002
  • Thermal design is required with considering thermal stability to verify the reliability of electric power device with using IGBT. Numerical analysis is performed to analyzed the change in thermal resistance with respect to the various thermal density of heating element. Correlations between thermal resistance and heat generation density are established. With using these correlations, performance curve is composed with respect to the change in thermal resistance of cooling conditions for natural convection and forced convection. Thermal fatigue is occurred at the Inside and outside of IGBT by repeated heat load. The crack is occurred between base plate and ceramic substrate for the inside. When the crack length is 4mm, the failure is occurred. Therefore, Thermal design method considering thermal density, thermal fatigue resistance is presented on this study and it is expected to thermal design with considering life prediction.

  • PDF

The Effect of Stocking Density on Stress Related Genes and Telomeric Length in Broiler Chickens

  • Beloor, J.;Kang, H.K.;Kim, Y.J.;Subramani, V.K.;Jang, I.S.;Sohn, S.H.;Moon, Yang Soo
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제23권4호
    • /
    • pp.437-443
    • /
    • 2010
  • To be economically profitable, the poultry industry demands an increase in stocking density, which could adversely affect chicken welfare. The current study was performed to investigate the effect of stocking density on stress-related, heat shock protein genes (HSP70 and HSP90), 3-hydroxyl-3-methyl-glutaryl coenzyme A reductase (HMGCR) gene and telomere length in broiler chickens. Seven-day-old broiler chickens were housed at High (0.0578 $m^2$/bird), Standard (0.077 $m^2$/bird) and Low (0.116 $m^2$/bird) stocking densities with 8 replicates each until 35 d of age. The growth performance, such as body weight gain and average daily feed intake, was found to be significantly (p<0.05) higher in the Low density group, but these parameters did not show any difference between the High and Standard groups. Other growth performance, such as feed conversion ratio and final feed intake, showed no difference among the treated groups. The expression levels of HSP70 and HMGCR were found to be elevated with the increase of stocking density. The expression level of these genes was significantly (p<0.05) higher in the High density stocked group compared with the other groups, whereas the expression levels were not significantly different between the Low and Standard groups. The expression levels of HSP90 did not show any significant changes among the treated groups. The telomeric length of the birds housed in High density was reduced significantly (p<0.05) when compared to that of the birds in Low density. These results clearly indicate that birds stocked at high density show physiological adaptive changes indicative of stress at gene transcriptional and telomere levels.

지중 열교환기 성능 분석을 위한 지반 열물성 조사 (Investigation of ground thermal characteristics for performance analysis of borehole heat exchanger)

  • 심병완;송윤호;김형찬;조병욱;박덕원;임도형;이영민
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2005년도 제17회 워크샵 및 추계학술대회
    • /
    • pp.587-590
    • /
    • 2005
  • A detailed geothermal characteristics survey with numerical simulations of the heat transfer in a site for ground source heat pump system is necessary for deploying a shallow geothermal utilization system. Density, specific heat, thermal diffusivity, and thermal conductivity are measured on 91 core samples from a 300 m deep borehole in KIGAM(Korea Institute of Geoscience and Mineral Resources). The heat flow is estimated from the thermal gradient and average thermal conductivity and the correlation between fracture system and hydraulic conductivity is analyzed. From the obtained ground information of the study site the performance of the ground heat pump system can be analyzed with some detailed numerical simulations for seasonal heat pump operation skill and optimal system design techniques.

  • PDF

A Study of the Defrosting Behavior according to Surface Characteristics of a Fin-Tube Heat Exchanger

  • Jhee, Sung;Lee, Kwan-Soo
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제8권2호
    • /
    • pp.101-107
    • /
    • 2000
  • In this study, the defrosting behavior according to the surface characteristics of a fin-tube heat exchanger is experimentally examined. It has been found that the draining rates of the hydrophilic and hydrophobic heat exchangers are evenly dispersed during do-frosting, compared with that of the bare one. This is due to the high density frost of the hydrophilic heat exchanger, and the surface characteristics of the hydrophobic heat ex-changer, The rest periods of the hydrophilic and hydrophobic heat exchangers are shorter, and their weight of residual water is also smaller than that of the bare heat exchanger. The hydrophobic heat exchanger is the most efficient in terms of the defrosting efficiency.

  • PDF