• 제목/요약/키워드: Heat demand

검색결과 483건 처리시간 0.027초

히이트파이프 다발을 이용한 냉축열시스템에서의 대류열전달에 관한 연구 (A Study on the Convective Heat Transfer in a Regenerative Ice Energy System by a Bundle of the Heat-pipes.)

  • 권형정;김경석;김경근
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제14권4호
    • /
    • pp.57-66
    • /
    • 1990
  • In the design of an electric power plant, the capacity to meet the peak load demand is one of the important factors to be considered. This peak load usually occurs when the most of the cooling air conditioning systems are being operated during daytime in summer season, which inevitably entails the construction of an additional electric power plant. This study is aimed to carry out a basic experiment for the development of a cooling air conditioning system using the ice energy by the surplus electric power during the night-time. The experimental apparatus consists of four major parts; (1) the heating section consisting of the air duct and I.D. fan, (2) the cold section with the ice chamber, (3) the bundle of heat pipes made in a form of the staggered arrangement with ${C_y}/{d_o}$=2.0 and ${C_x}/{d_o}$=1.73, (4) the refrigerator system to cool down the ice chamber. This study involves an intensive experiment concerning the convective heat transfer of the air flow surrounding the bundle of heat pipes. This major experimental parameters are the amount of working fluid, the velocity of air and the working temperature. The major findings of the present study are as follows; (1) The optimum amount of the working fluid necessary for the horizontal heat pipes is much more than that for the vertical type. (2) The convective heat transfer coefficients of the air are coincided with the empirical equations of Grimson and ${\breve{Z}ukauskas}$. (3) The equation of the mean heat transfer coefficient obtained in the present study is ${N_um}=0.32 {Re_max^{0.63}}$.

  • PDF

부하 대응 제어방식을 적용한 축열식 히트펌프시스템의 성능 해석 (A Performance Analysis on a Heat pump with Thermal Storage Adopting Load Response Control Method)

  • 김동준;강병하;장영수
    • 설비공학논문집
    • /
    • 제30권3호
    • /
    • pp.130-142
    • /
    • 2018
  • We use heat pumps with thermal storage system to reduce peak usage of electric power during winters and summers. A heat pump stores thermal energy in a thermal storage tank during the night, to meet load requirements during the day. This system stabilizes the supply and demand of electric power; moreover by utilizing the inexpensive midnight electric power, thus making it cost effective. In this study, we propose a system wherein the thermal storage tank and heat pump are modeled using the TRNSYS, whereas the control simulations are performed by (i) conventional control methods (i.e., thermal storage priority method and heat pump priority method); (ii) region control method, which operates at the optimal part load ratio of the heat pump; (iii) load response control method, which minimizes operating cost responding to load; and (iv) dynamic programming method, which runs the system by following the minimum cost path. We observed that the electricity cost using the region control method, load response control approach, and dynamic programing method was lower compared to using conventional control techniques. According to the annual simulation results, the electricity cost utilizing the load response control method is 43% and 4.4% lower than those obtained by the conventional techniques. We can note that the result related to the power cost was similar to that obtained by the dynamic programming method based on the load prediction. We can, therefore, conclude that the load response control method turned out to be more advantageous when compared to the conventional techniques regarding power consumption and electricity costs.

저온 외기조건에서 케스케이드 급탕열펌프의 성능특성에 관한 해석적 연구 (Numerical Study of the Performance Characteristics of a Cascade Heat Pump Water Heater at Low Ambient Temperatures)

  • 송재현;정해원;박재우;강훈;김용찬
    • 설비공학논문집
    • /
    • 제25권5호
    • /
    • pp.225-232
    • /
    • 2013
  • Heat pump systems have been widely adopted in buildings for cooling and heating, due to their higher energy efficiency. Recently, the demand for hot water supply from the heat pump system has been increasing. To increase the water supply temperature with higher system efficiency and reliability, a heat pump water heater adopting cascade cycle was investigated in this study. The cascade heat pump water heater consisted of a low-stage cycle using R410A, and a high-stage cycle using R134a. A simulation program for the cascade heat pump water heater was developed, and verified by comparison with experimental data. The performance of the cascade heat pump water heater was optimized, by varying the compressor rotating speeds of the low- and high-stage cycles. At low ambient temperatures, the performance of the cascade cycle was compared with that of the single-stage cycle. The system efficiency of the cascade cycle was higher than that of the single-stage cycle, showing a lower compression ratio and compressor discharge temperature.

음식폐기물의 생물학적 수소 발효시 열처리 효과 (Effect of Heat Treatment on Biohydrogen Production from Food Waste)

  • 이채영;박인근
    • 유기물자원화
    • /
    • 제18권1호
    • /
    • pp.81-88
    • /
    • 2010
  • 음식폐기물의 혐기성 발효시 열적 전처리의 최적 조건을 도출하기 위하여 수소 발생 특성을 평가하였다. 음식폐기물의 열적 전처리의 경우 용해성 화학적 산소요구량(SCOD)과 탄수화물 함량을 증가시켜 수소 수율을 향상시키는 것으로 나타났다. 실험결과 SCOD와 탄수화물을 기준으로 한 최대 가용화 효율은 각각 55.1%와 223.6%로 나타났다. 반응시간에 따라 전처리 효과는 증가하는 경향을 보였으나 20분간 1시간 비교시 약 7%의 차이를 보여 20분 이상의 반응시간의 증가는 크지 않은 것으로 나타났다.

가정용 흡수식 냉난방기 개발을 위한 재생기 성능실험 (Performance Experiment of Generator for Household Absorption Chiller and Heater)

  • 유선일;권오경;윤정인
    • 대한기계학회논문집B
    • /
    • 제23권10호
    • /
    • pp.1347-1354
    • /
    • 1999
  • Recently, the markets of the air conditioner are enlarging. The market size will reach 2.0 billion won in 2000. Electric heat pumps have been utilized as main residential air conditioners. especially in Korea. They cause a surge up electric power demand during summer. Moreover, the use of HCFCs and HFCs causes serious problem to the global environment such as global warming and ozone layer destruction. Absorption chiller and heater could solve such problems. It was built and tested for analyzing the performance of the generator for absorption chiller and heater. Experiment was done with a high temperature generator, a low temperature generator, heat exchangers, a condenser and a solution tank. It was tested that the double effect series flow cycle with two kinds of solution cycle. Solution cycle B showed better than solution cycle A. Two kinds of heat exchanger were used, where one's heat transfer area is bigger than the other. Bigger one increased a little performance of absorption chiller and heater. But it was not economical. From this study, we got that the coefficient of performance(COP) is 0.82 and the capacity is 7.24 kW for an absorption chiller and heater.

지역난방 공동주택에서 급탕 2단 열교환기 용량의 적정성 평가에 관한 연구 (A Study on the Design Capacity of 2-stage Hot Water Heat Exchanger in Apartment Housings with District Heating System)

  • 사기용;정광섭;김영일;나채문;김성민;김상호
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.1037-1042
    • /
    • 2009
  • In connection with a recent research project dealing with heating system in apartment buildings by district heating, it was realised that in general very little information on the actual performance of heating and hot water systems in apartment buildings has been documented. In order to improve of district heating systems, a prediction of the heat demand first needs to be determined before a production plan. this is hot water heat system developed in this paper. this is also analyzed relation heat load with preheat load in hot water heating exchanger system.

  • PDF

마루판용 합판의 단판 구성요소에 따른 열전달 특성에 관한 연구 (A Study on Heat Transfer of Plywood for Wood Based Flooring by Veneer Composition)

  • 피덕원;최송규;강호양;강석구
    • 한국가구학회지
    • /
    • 제23권3호
    • /
    • pp.298-304
    • /
    • 2012
  • Since 1990's, a flooring based on plywood has gotten customers' demand. Costs of raw material and production increased because of changed environment of industry. Tropical timber such as Red Meranti (Shorea acuminate) used for raw material of the floor has been depleting beside countries in South Eastern Asia changed species of afforestation. As a result, it gets hard to secure good quality of raw material for plywood. Moreover plywood price is increased suddenly after earthquake in Japan. Eucalyptus (Eucalyptus globulus) in china has been using for raw material as a countermeasure of changed environment of industry. In this study, possibility of using flooring consisted of Eucalyptus veneer as a core layer was checked by heat transfer experiments. Flooring consisted of Red Meranti was used for comparison. Two factors which impact on heat transfer are a type of density gradient and density difference between Long-grain veneer and Short-grain veneer. Red Meranti samples are 'M' type of density gradient on the other hand Eucalyptus samples are 'W' type of density gradient.

  • PDF

건물 에너지 상세 해석을 통한 소형 열병합 발전 및 히트펌프 복합 시스템의 경제성 분석 (Energy and Economic Analysis of Heat Recovery Cogeneration Loop Integrated with Heat Pump System by Detailed Building Energy Simulation)

  • 서동현;고재윤;박률
    • 설비공학논문집
    • /
    • 제21권2호
    • /
    • pp.71-78
    • /
    • 2009
  • Up until recently, the energy and the economic analysis of a cogeneration system have been implemented by a manual calculation that is based on monthly thermal loads of buildings. In this study, a cogeneration system modeling validation with a detail building energy simulation, eQUEST, for a building energy and cost prediction has been implemented. By analyzing the hourly building electricity and thermal loads, it enables users to decide proper cogeneration system capacity and to estimate more accurate building energy consumption. eQUEST also verified the energy analysis when the heat pump system is integrated with the cogeneration system. The mechanical system configuration benefits from the high efficiency heat pump system while avoiding the building electricity demand increase. Economic analysis such as LCC (Life Cycle Cost) method is carried out to verify economical benefits of the system by applying actual utility rates of KEPCO(Korea Electricity Power COmpany) and KOGAS(KOrea GAS company).

저융점 폴리에스터 자카드직물의 물성에 대한 열처리 효과 (Effect of Heat Treatment on the Physical Properties of LM PET Jacquard Fabrics)

  • 이선영;김정화;김의화;이정순;이승구
    • 한국염색가공학회지
    • /
    • 제25권3호
    • /
    • pp.206-214
    • /
    • 2013
  • There has been an increasing demand for high performance and energy-saving of blind. In order to develop the eco-friendly blind textiles, heat treatment process has been utilized for LM(Low Melting) polyester fabrics and the changes of the physical properties of the treated fabrics were examined according to temperature of heat treatment. Morphology, surface reflectance, contact angle, luster, thermal property and mechanical property of heat treated LM polyester fabrics were investigated. As results, morphology analysis of thermal treated fabrics confirmed that degree of fusion of LM polyester yarns improved with increase of temperature. Surface reflectance of thermal treated fabrics decreased with increase of temperature. Luster and contact angle of a water droplet on thermal treated fabrics increased slightly with increase of temperature. The mechanical properties of the fabrics by KES-FB system were found to be temperature-dependent and especially, bending and shear properties among them were highly related to temperature.

열전도성 고분자 복합소재/금속 소재 하이브리드 구조의 방열기구 설계 및 방열특성에 관한 연구 (A study on the design and cooling of the heat sink with hybrid structure of conductive polymer composite and metal)

  • 유영은;김덕종;윤재성;박시환
    • Design & Manufacturing
    • /
    • 제10권3호
    • /
    • pp.14-19
    • /
    • 2016
  • Thermally or electrically conductive filler reinforced polymer composites are extensively being developed as the demand for light weight material increases rapidly in industiral applications need good conductivity such as heat sink of the electronics or light. Carbon or ceramic materials like graphite, carbon nanotube or boron nitride are typical conductive fillers with good thermal or electical conductivity. Using these conductive fillers, the polymer composites in the market show wide range of thermal conductivity from approximately 1 W/mK to 20 W/mK, which is quite enhanced considering the thermal conductivity lower than 0.5 W/mK for most polymeric materials. The practical use of these composites, however, is yet limited to specific applications because most composites are still not conductive enough or too difficult to process, too brittle, too expensive for higher conductivity. For practical use of conductive composite, the thermal conductivity required depending on the heat releasing mode are studied first for simplified unit cooling geometry to propose thermal conductivities of the composites for reasonable cooling performance comparing with the metal heat sink as a reference. Also, as a practical design for heat sink based on polymer composite, composite and metal sheet hybrid structures are investigated for LED lamp heat sink and audio amplication module housing to find that this hybrid structure can be a good solution considering all of the cooling performance, manufacturing, mechanical performance, cost and weight.