• 제목/요약/키워드: Heat bridge

검색결과 182건 처리시간 0.028초

인천 LNG 지하탱크 Bottom 의 온도균열제어 (Thermal Crack Control about of LNG in Inchon)

  • 구본창;하상욱;김동석;하재담;이종열;권영호
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2000년도 봄 학술발표회 논문집
    • /
    • pp.291-296
    • /
    • 2000
  • The crack of concrete induced by the heat of hydration is s serious problem, particularly in concrete structures such as bridge piers. thick walls, box type walls, mat-slab of nuclear reactor building, dams of foundations of high rise buildings, etc. As a result of the temperature rise and restriction condition of foundation, the thermal stress which way induce the cracks can occur. Therefore the various techniques of the thermal stress control in massive concrete have been widely used. One of them is prediction of the thermal stress, besides low-heat cement which mitigates the temperature rise, design change which consider steel bar reinforcement, operation control and so on. In this study, firstly it introduce the thermal cracks control technique by employing low-heat cement concrete, thermal stress analysis, Secondly it shows the application of the cracks control technique like the bottom of No.15,16 Underground LNG Tank in Inchon.

  • PDF

Experimental Study on Single Bubble Growth Under Subcooled, Saturated, and Superheated Nucleate Pool Boiling

  • Kim Jeong-Bae;Lee Jang-Ho;Kim Moo-Hwan
    • Journal of Mechanical Science and Technology
    • /
    • 제20권5호
    • /
    • pp.692-709
    • /
    • 2006
  • Nucleate pool boiling experiments with constant wall temperature were performed using pure R1l3 for subcooled, saturated, and superheated pool conditions. A microscale heater array and Wheatstone bridge circuits were used to maintain the constant wall temperature and to measure the instantaneous heat flow rate accurately with high temporal and spatial resolutions. Images of bubble growth were taken at 5,000 frames per second using a high-speed CCD camera synchronized with the heat flow rate measurements. The bubble geometry was obtained from the captured bubble images. The effect of the pool conditions on the bubble growth behavior was analyzed using dimensionless parameters for the initial and thermal growth regions. The effect of the pool conditions on the heat flow rate behavior was also examined. This study will provide good experimental data with precise constant wall temperature boundary condition for such works.

새로운 열교환 방식을 이용한 유도가열 과열증기 발생장치 개발 (Development of induction heating superheater system using new heat exchanging method)

  • 설용태;이의용;권혁민
    • 한국산학기술학회논문지
    • /
    • 제10권4호
    • /
    • pp.740-746
    • /
    • 2009
  • 본 논문에서는 공진형 유도가열기를 이용한 2단 직렬 부하형 유도가열 과열증기 발생장치를 제안하였다. 발열방식은 외부의 가열코일로부터 특수 합금 발열체에 비접촉 상태로 전자유도 와전류를 구조체에 흐르게 하였다. 인버터는 풀-브리지 고주파 직렬 부하 공진형 이며, LC 공진 설계에서 부하자체를 인덕터로 선정하여 효율을 최대화 하였다. 개발된 장치는 전자유도가열 발열체와 유체이동에 의한 새로운 열교환 방식으로 일체의 연소과정 없이 기체, 액체 및 증발체 등을 상온에서 고온에 이르기까지 고정도의 가열이 가능하다.

Thermal Performance Evaluation of Junction Thermal Bridge according to Installation Position of Window

  • Lee, Soo-Man;Kim, Dong-Yun;Ahn, Jung-Hyuk;Eom, Jae-Yong;Shin, U-Cheul
    • KIEAE Journal
    • /
    • 제17권3호
    • /
    • pp.15-21
    • /
    • 2017
  • Purpose: "Building energy design standard" is used to limit the thermal transmittance of building in Korea. However, it only covers the insulation standard for each appropriate elements of a building, not the thermal performance of Junction thermal bridge of windows and doors installed in wall. Therefore in this study, we have evaluated the thermal performance of Junction thermal bridge depending on installation method and position of windows and provide it as design data. Method: We analyzed heat transfer of 4-Track sliding window and tilt & turn triple glazed window that are placed in the first class category on window energy efficiency rating using Window 7.4 and Therm 7.4. Result : First, linear thermal transmittance of 4-Track sliding window differs by 2.2 times or more depending of installation method and location. It is higher than the linear thermal transmittance, 0.01W/mK, proposed by Passivhaus. Second, linear thermal transmittance of Tilt & turn triple glazed window differs by 7.7 times or more depending of installation method and location. The average linear thermal transmittance was less than 0.01W /mK when windows were installed on the internal wall insulation by the fixed hardware attachment method. Third, the thermal losses of a window caused by a junction thermal bridge are inversely proportional to the window area and converge gradually as the area increased.

화재 발생시 열응력에 의한 복합재료 과량 시스템의 거동에 관한 연구 (Numerical Study of Lightweight FRP Bridge Deck System induced by Thermal Stress by Fire)

  • 정우영;이형길;박희광;심인섭;송영진
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2006년도 정기 학술대회 논문집
    • /
    • pp.928-931
    • /
    • 2006
  • Due to their light weight, high stiffness-to-weight and strength-to-weight ratios, and potentially high resistance to environmental degradation, resulting in lower life-cycle costs, polymer composites, are increasingly being considered for use in civil infrastructure applications. Recently, an FRP deck has been installed on a state highway, located in New York State. In this study, a thermal stress analysis was conducted using finite element method to study failure mechanisms of the superstructure. This analysis evaluated small and large temperature gradient effects on the FRP deck considering lightweight of FRP deck and ply orientations at the interface between steel girders and FRP deck Finite element model was verified using the load tests of the bridge deck. Finally, the analytical results shows the possible failure mechanism of FRP deck under various temperature changes and its corresponding index is suddenly varied depending on the rapid change of temperature on the deck plate.

  • PDF

Automatic frequency Control Current-Source Inverter for Forging Application

  • Chudjuarjeen, Saichol;Koompai, Chayant;Monyakul, Veerapol
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2004년도 ICCAS
    • /
    • pp.238-242
    • /
    • 2004
  • The paper describes an automatic frequency control current-fed inverter for forging applications. The IGBT in series with diodes as its switching devices in the inverter circuit which is of full-bridge type. The operating frequency is automatically tracked to maintain a small constant leading phase angle when load parameters change. The load voltage is controlled to protect the switches. The output power can be adjusted by varying the input current from phase controlled rectifiers which is a part of current source. The system has been operated at 15-17 kHz. The output power transferred to the load is 1,595 watts. It can heat the steel work pieces with 15 mm diameter and 120 mm long from room temperature to approximately 1100 $^{\circ}C$ within 20 seconds with 0.97 leading power factor on the input side.

  • PDF

Study on the Controlled Gel Formation and Photochromic Properties of a New Cholesterol-bridge-naphthopyran Dyad

  • Sun, Lin;Wang, Guang;Liu, Longbo;Wang, Ai Xia
    • Bulletin of the Korean Chemical Society
    • /
    • 제35권5호
    • /
    • pp.1343-1348
    • /
    • 2014
  • A cholesterol-bridge-naphthopyran dyad (NP-MCB) was designed and synthesized. NP-MCB can readily self-assemble into gels under ultrasound-radiation in several organic solvents and the formed gels easily transfer to solution by heat. This reversible process can be repeated many times. Scanning Electron Microscopy results showed that the morphologies of all formed xerogels in different solvents have fibrillar microstructure. The gels formation was due to energy and pressure afforded by the ultrasonic process, resulting in formation of molecular hydrogen bonding and molecular aggregation. NP-MCB displayed the normal photochromism both in solution and gel states. The kinetic results confirm that the colored merocyanine in gels show a slower fading speed than that in solution due to the compact aggregation of NP-MCB molecules in gels. The xerogel film formed in polar gelling solvent had large surface wettability than that in nonpolar gelling solvent.

현장실험을 통한 VES-LMC 균열발생 원인분석 (Diagnosis of Crack Occurrence of Very-Early Strength Latex-Modified Concretes through Field Tests)

  • 최판길;이봉학
    • 산업기술연구
    • /
    • 제26권A호
    • /
    • pp.139-146
    • /
    • 2006
  • Many concrete bridge decks develop transverse cracking shortly after construction. These cracks accelerate corrosion of reinforcing steel and lead to concrete deterioration, damage to components beneath the deck, unsightly appearance. These cracks shorten the service life and increase maintenance costs of bridge structures. In this study, VES-LMC overlay, which provides the same benefits as a conventional overlay, is designed to cure very quickly. Although the materials for VES overlays are more expensive, the cost is more than offset by the savings on traffic control and work zone safety measures. Otherwise, reaction of hydration occurs very rapidly in beginning step(concrete placing). As a results, thermal cracking can be occur by thermal stress in accordance with hydration-heat The purpose of this study was to estimate diagnosis of crack occurrence of VES-LMC through field tests at early-age.

  • PDF

강교의 초기응력을 고려한 내하력 해석 (Analysis on the Load Carrying Capacity of Steel Bridges Considering Initial Stress)

  • 장경호;강재훈;장갑철
    • 한국공간구조학회논문집
    • /
    • 제4권4호
    • /
    • pp.129-136
    • /
    • 2004
  • Almost the steel bridges are manufactured and constructed by using weld process. The welding is necessary for connecting the flange, web and stiffener of steel bridges. However, residual stress and welding deformation producted by welding is a causes of decreasing the load carrying capacity of steel bridges. therefore, it is need to consider the initial stresses by welding when design the steel bridge. However, the influence of initial stress producted by welding on load carrying capacity of steel bridges is not elucidated. In this paper, the initial stress state on the flange, web and stiffener of steel bridges are clarified by carrying out 3-dimensional non-steady heat conduction analysis and 3-dimensional thermal elastic-plastic analysis. The influence of initial stress by welding on load carrying capacity of steel bridges is clarified by carrying out 3-dimensional elastic-plastic finite element analysis using finite deformation theory.

  • PDF

화재에 의한 사장교 케이블의 유한요소 해석 (FEM Analysis on the Damage for the Cable of Cabled-suspension Bridges by Fire)

  • 송용선;이병식;김형주;박원태
    • 한국산학기술학회논문지
    • /
    • 제9권1호
    • /
    • pp.136-142
    • /
    • 2008
  • 최근 케이블을 이용한 현수교 또는 사장교 형식의 교량들이 건설되고 있다. 이러한 교량에서 자동차 충돌등의 사고에 의한 교량위 화재로 손상을 받는 경우가 종종 발생되고 있으나, 화재에 의한 교량구조물의 안정성에 대한 연구는 거의 없는 실정이다. 따라서 본 논문에서는 국도확장사업구간에 시공되고 있는 사장교 교량을 대상으로 하여, 상용소프트웨어인 Solid Works 2007을 사용하여 모델링하고, COSMOS FloWorks 2007소프트웨어에 의한 열전달 해석 및 열응력 해석을 통하여 와이어, 교량위 화재 발생시 와이어, 사재방재 파이프 및 그 주변에 대한 사재방재케이블의 안전을 검토 하였다. 해석변수로는 열원의 온도, 방호책과 열원사이의 거리, 풍속, 스텐인레스강관 끝단의 높이를 사용하였다.