• 제목/요약/키워드: Heat blanket

검색결과 36건 처리시간 0.02초

A Theoretical Model of Critical Heat Flux in Flow Boiling at Low Qualities

  • Kim, Ho-Young;Kwon, Hyuk-Sung;Hwang, Dae-Hyun;Kim, Yongchan
    • Journal of Mechanical Science and Technology
    • /
    • 제15권7호
    • /
    • pp.921-930
    • /
    • 2001
  • A new theoretical critical heat flux (CHF) model was developed for the forced convective flow boiling at high pressure, high mass velocity, and low quality. The present model for an intermittent vapor blanket was basically derived from the sublayer dryout theory without including any empirical constant. The vapor blanket velocity was estimated by an axial force balance, and the thickness of vapor blanket was determined by a radial force balance for the Marangoni force and lift force. Based on the comparison of the predicted CHF with the experimental data taken from previous studies, the present CHF model showed satisfactory results with reasonable accuracy.

  • PDF

RCC-MR 코드에 기반한 ITER 시험증식블랑켓 일차벽 설계 (First Wall Design of ITER Test Blanket Module(TBM) based on RCC-MR Code)

  • 신규인;이동원
    • 한국안전학회지
    • /
    • 제27권6호
    • /
    • pp.14-19
    • /
    • 2012
  • The Helium cooled ceramic reflector(HCCR) test blanket module(TBM) has been designed and developed to participate the ITER(International Thermonuclear Experimental Reactor) test blanket program in Korea. The TBM was one of the main objectives for developing ITER for proving the tritium self-sufficiency and the heat transfers to produce the electricity with the breeding blanket concept. Among the TBM components, the first wall(FW) was the most important component in safety since it was directly faced a high level of a heat and fast neutrons from the plasma side and could protect the others components inside TBM. In this paper, the FW has been designed through the thermo-mechanical analysis considering ITER operation conditions. With the developed simple models, the stress limit analysis based on RCC-MR code which is the nuclear power plant design codes in France was evaluated for the allowable design criteria. The results showed that the designed FW model satisfied $1.5S_m$ or $3S_m$ of the allowable stress($S_m$) in RCC-MR code at the maximum stress region in the FW.

수직관내 미포화수의 강제대류 천이비등에 대한 역학적 모델 (A Mechanistic Model for Forced Convective Transition Boiling of Subcooled Water in Vertical Tubes)

  • Lee, Kwang-Won;Baik, Se-Jun;Han, Sang-Good;Joo, Kyung-Oin;Yang, Jae-Young
    • Nuclear Engineering and Technology
    • /
    • 제27권4호
    • /
    • pp.503-517
    • /
    • 1995
  • 강제대류 천이비등 열유속을 보다 실제 적으로 예측하기 위한 역학적 모델을 개발하였다. 이 모델은 가열된 벽면 근처를 어떤 기포기둥(Vapor Blanket)이 통과할 때 일어나는 다단계 비등과정 즉, 임계 기포기둥의 형성, 기포기둥밑의 미소액막(Macrolayer)의 기화 및 고갈, 그리고 얇은 기체막에서 일어나는 불안정한 막비등과정에 기초하였다. 핵비등이탈점 (DNB )과 막비등이탈점 (DFB)사이의 천이비등 곡선상의 열유속은 임계 기포기둥이 주어진 벽면을 통과할 동안 상기한 각 비등과정의 지속 시간비(Time Fraction)를 각 비등열유속에 곱한 후 그것을 합하여 정량화하였다. 이 모델의 예측치를 현재까지 발표된 문헌들에 나타난 실험치와 비교한 결과, 본 모델은 저건도 및 10 bar 근처의 고압조건의 실험치를 잘예측하는 것으로 나타났다.

  • PDF

Three-dimensional thermal-hydraulics/neutronics coupling analysis on the full-scale module of helium-cooled tritium-breeding blanket

  • Qiang Lian;Simiao Tang;Longxiang Zhu;Luteng Zhang;Wan Sun;Shanshan Bu;Liangming Pan;Wenxi Tian;Suizheng Qiu;G.H. Su;Xinghua Wu;Xiaoyu Wang
    • Nuclear Engineering and Technology
    • /
    • 제55권11호
    • /
    • pp.4274-4281
    • /
    • 2023
  • Blanket is of vital importance for engineering application of the fusion reactor. Nuclear heat deposition in materials is the main heat source in blanket structure. In this paper, the three-dimensional method for thermal-hydraulics/neutronics coupling analysis is developed and applied for the full-scale module of the helium-cooled ceramic breeder tritium breeding blanket (HCCB TBB) designed for China Fusion Engineering Test Reactor (CFETR). The explicit coupling scheme is used to support data transfer for coupling analysis based on cell-to-cell mapping method. The coupling algorithm is realized by the user-defined function compiled in Fluent. The three-dimensional model is established, and then the coupling analysis is performed using the paralleled Coupling Analysis of Thermal-hydraulics and Neutronics Interface Code (CATNIC). The results reveal the relatively small influence of the coupling analysis compared to the traditional method using the radial fitting function of internal heat source. However, the coupling analysis method is quite important considering the nonuniform distribution of the neutron wall loading (NWL) along the poloidal direction. Finally, the structure optimization of the blanket is carried out using the coupling method to satisfy the thermal requirement of all materials. The nonlinear effect between thermal-hydraulics and neutronics is found during the blanket structure optimization, and the tritium production performance is slightly reduced after optimization. Such an adverse effect should be thoroughly evaluated in the future work.

High heat flux limits of the fusion reactor water-cooled first wall

  • Zacha, Pavel;Entler, Slavomir
    • Nuclear Engineering and Technology
    • /
    • 제51권5호
    • /
    • pp.1251-1260
    • /
    • 2019
  • The water-cooled WCLL blanket is one of the possible candidates for the blanket of the fusion power reactors. The plasma-facing first wall manufactured from the reduced-activation ferritic-martensitic steel Eurofer97 will be cooled with water at a typical pressurized water reactor (PWR) conditions. According to new estimates, the first wall will be exposed to peak heat fluxes up to $7MW/m^2$ while the maximum operated temperature of Eurofer97 is set to $550^{\circ}C$. The performed analysis shows the capability of the designed flat first wall concept to remove heat flux without exceeding the maximum Eurofer97 operating temperature only up to $0.75MW/m^2$. Several heat transfer enhancement methods (turbulator promoters), structural modifications, and variations of parameters were analysed. The effects of particular modifications on the wall temperature were evaluated using thermo-hydraulic three-dimensional numerical simulation. The analysis shows the negligible effect of the turbulators. By the combination of the proposed modifications, the permitted heat flux was increased up to $1.69MW/m^2$ only. The results indicate the necessity of the re-evaluation of the existing first wall concepts.

Electromagnetic-thermal two-way coupling analysis and application on helium-cooled solid blanket

  • Kefan Zhang;Shuai Wang;Hongli Chen
    • Nuclear Engineering and Technology
    • /
    • 제55권3호
    • /
    • pp.927-938
    • /
    • 2023
  • The blanket plays an important role in fusion reactor and stands extremely high thermal and electromagnetic loads during operation situation and plasma disruption event, brings the need for precise thermal and electromagnetic analysis. Since the thermal field and EM field interact with each other nonlinearly, we develop a method of electromagnetic-thermal two-way coupling by using finite element software COMSOL. The coupling analyses of blanket under steady state and MD event are implemented and the results are analyzed. For steady state, the influences of coupling effects are relatively small but still recommended to be considered for a high precision analysis. The influence of thermal field on EM field can't be ignored under MD events. The variation of force density could cause a significant change in stress in certain parts of blanket. The influence of Joule heat during MD event is negligible, yet the potential temperature rise caused by induced current after MD event still needs to be researched.

녹지대 분포가 도시 지역의 소기후에 미치는 영향 (On the Impacts to the Loca l Climate Change of Urban Area due to the Vegetation Canopy)

  • 진병화;변희룡
    • 한국환경과학회지
    • /
    • 제9권2호
    • /
    • pp.101-108
    • /
    • 2000
  • Through numerical experiment using simplified OSU-1D PBL(Oregon State University One-Dimensional Planetary Boundary Layer) model and field measurement, we studied the impacts of vegetation canopy on heat island that was one of the characteristics of local climaate in urban area. it was found that if the fraction of vegetation was extended by 10 percent, the maximum air temperature and the maximum ground temperature can come down about 0.9${\circ}C$, 2.3${\circ}C$, respectively. Even though the field measurement was done under a little unstable atmospheric condition, the canopy air temperature was lower in the daytime, and higher at night than the air and ground temperature. This result suggests that the extention of vegetation canopy can bring about more pleasant local climate by causing the oasis, the shade and the blanket effect.

  • PDF

Thermal Burn Injury from a Forced-Air Warming Device in an Anesthetized Dog with Peripheral Hypoperfusion

  • Lee, Sungin;Lee, Aeri;Lee, Maro;Kim, Wan Hee
    • 한국임상수의학회지
    • /
    • 제37권6호
    • /
    • pp.331-335
    • /
    • 2020
  • A 13-year-old female Poodle presented with gallbladder rupture caused by a mucocele and hypoperfusion. The animal had a thermal burn injury caused by a forced-air warming device used for hypothermia during surgery. This could be attributed to two causes. First, the forced-air warming device was used with direct hosing, without attachment to an air blanket, and the heat was concentrated in a single area. Second, perioperative peripheral hypoperfusion hampered heat dissipation and increased the susceptibility to a burn injury. These findings suggest that an air blanket should be used with a forced-air warming device according to the manufacturer's instructions. Furthermore, patients with peripheral hypoperfusion are at a higher risk of burn injuries and require close monitoring.

HIGH HEAT FLUX TEST WITH HIP BONDED 35X35X3 BE/CU MOCKUPS FOR THE ITER BLANKET FIRST WALL

  • Lee, Dong-Won;Bae, Young-Dug;Kim, Suk-Kwon;Jung, Hyun-Kyu;Park, Jeong-Yong;Jeong, Yong-Hwan;Choi, Byung-Kwon;Kim, Byoung-Yoon
    • Nuclear Engineering and Technology
    • /
    • 제42권6호
    • /
    • pp.662-669
    • /
    • 2010
  • To develop the manufacturing methods for the blanket first wall (FW) of the International Thermonuclear Experimental Reactor (ITER) and to verify the integrity of the joint, Be/Cu mockups were fabricated and tested at the KoHLT-1 (Korea Heat Load Test facility), a graphite heater facility located at the Korea Atomic Energy Research Institute (KAERI). Since Be and Cu joining is the focus of the present study, the fabricated mockups had a CuCrZr heat sink joined with three Be tiles as an armor material, unlike the original ITER blanket FW, which has a stainless steel structure and coolant tubes. Hot isostatic pressing (HIP) was carried out at $580^{\circ}C$ and 100 MPa for 2 hours as the method for Be/Cu joining. Three interlayers, namely, $1{\mu}mCr/10{\mu}mCu$, $1{\mu}mTi/0.5{\mu}mCr/10{\mu}mCu$, and $5{\mu}mTi/10{\mu}mCu$ were applied as a coating to the Be tiles by a physical vapor deposition (PVD) method. A shear test was performed with the specimens, which were fabricated by the same methods as those used to fabricate the mockups. The average values were 125 MPa to 180 MPa, and the samples with the $1{\mu}mCr/10{\mu}mCu$ interlayer showed the lowest value. No defect or delamination was found in the joints of the mockups by the developed ultrasonic test using a flat-type probe with a 10 MHz frequency and a 0.25 inch diameter. High heat flux (HHF) tests were performed at $1.0\;MW/m^2$ heat flux for each mockup using the given conditions, and the results were analyzed by ANSYS-CFX code. For the test criteria, an expected fatigue lifetime about 1,000 cycles was obtained by analysis with ANSYS-mechanical code. Mockups using the interlayers of $1{\mu}mTi/0.5{\mu}mCr/10{\mu}mCu$ and $5{\mu}mTi/10{\mu}mCu$ survived up to 1,100 cycles over the required number of cycles. However, one of the Be tiles in the other two mockups using the $1{\mu}mCr/10{\mu}mCu$ interlayer was detached during the screening test, and others were detached by discharge after 862 cycles. The integrity of the joints using the proposed interlayers was proven by the HHF test, but the other interlayer requires more study before it can be used for the joining of Be to Cu. Moreover, it was confirmed that the measured temperatures agreed well with the analysis temperatures, which were used to estimate the lifetime and that the developed facility showed its capability of the long time operation.

OVERVIEW OF FUSION BLANKET R&D IN THE US OVER THE LAST DECADE

  • ABDOU M. A.;MORLEY N. B.;YING A. Y.;SMOLENTSEV S.;CALDERONI P.
    • Nuclear Engineering and Technology
    • /
    • 제37권5호
    • /
    • pp.401-422
    • /
    • 2005
  • We review here research and development progress achieved in US Plasma Chamber technology roughly over the last decade. In particular, we focus on two major programs carried out in the US: the APEX project (1998-2003) and the US ITER TBM activities (2003-present). The APEX project grew out of the US fusion program emphasis in the late 1990s on more fundamental science and innovation. APEX was commissioned to investigate novel technology concepts for achieving high power density and high temperature reactor coolants. In particular, the idea of liquid walls and the related research is described here, with some detailed examples of liquid metal and molten salt magnetohydrodynamic and free surface effects on flow control and heat transfer. The ongoing US ITER Test Blanket Module (TBM) program is also described, where the current first wall/blanket concepts being considered are the dual coolant lead lithium concept and the solid breeder helium cooled concepts, both using ferritic steel structures. The research described for these concepts includes both thermofluid MHD issues for the liquid metal coolant in the DCLL, and thermomechanical issues for ceramic breeder packed pebble beds in the solid breeder concept. Finally, future directions for ongoing research in these areas are described.