• Title/Summary/Keyword: Heat and Mass Flux

Search Result 449, Processing Time 0.021 seconds

A Comparative Study on Heat Loss in Rock Cavern Type and Above-Ground Type Thermal Energy Storages (암반공동 열에너지저장과 지상식 열에너지저장의 열손실 비교 분석)

  • Park, Jung-Wook;Ryu, Dongwoo;Park, Dohyun;Choi, Byung-Hee;Synn, Joong-Ho;Sunwoo, Choon
    • Tunnel and Underground Space
    • /
    • v.23 no.5
    • /
    • pp.442-453
    • /
    • 2013
  • A large-scale high-temperature thermal energy storage(TES) was numerically modeled and the heat loss through storage tank walls was analyzed using a commercial code, FLAC3D. The operations of rock cavern type and above-ground type thermal energy storages with identical operating condition were simulated for a period of five consecutive years, in which it was assumed that the dominant heat transfer mechanism would be conduction in massive rock for the former and convection in the atmosphere for the latter. The variation of storage temperature resulting from periodic charging and discharging of thermal energy was considered in each simulation, and the effect of insulation thickness on the characteristics of heat loss was also examined. A comparison of the simulation results of different storage models presented that the heat loss rate of above-ground type TES was maintained constant over the operation period, while that of rock cavern type TES decreased rapidly in the early operation stage and tended to converge towards a certain value. The decrease in heat loss rate of rock cavern type TES can be attributed to the reduction in heat flux through storage tank walls followed by increase in surrounding rock mass temperature. The amount of cumulative heat loss from rock cavern type TES over a period of five-year operation was 72.7% of that from above-ground type TES. The heat loss rate of rock cavern type obtained in long-period operation showed less sensitive variations to insulation thickness than that of above-ground type TES.

An analysis on the characteristics of regasification system for gas fuelled ship depending on the mixing ratio of eglycol and water (Gas Fuelled Ship용 재기화 시스템의 Eglycol Water 혼합비율에 따른 시스템 특성분석)

  • Lee, Yoon-Ho;Kim, You-Taek;Kang, Ho-Keun
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.38 no.7
    • /
    • pp.799-805
    • /
    • 2014
  • Recently, the regulations of the Local and Global for a variety of air pollution prevention has been enhanced by the steep rise in fuel oil prices. So, the appearance of Gas Fuelled Ships became necessary. In this study, we configured a regasification system which uses Eglycol water as a heating medium to evaporate before being supply fuel to the DF engine, then we analysed the system properties according to the Eglycol water mixing ratio. The results were as follows. When pressure, temperature, and flux of natural gas(NG) which are supplied to DF engines are uniformly kept, the higher mixing ratio of Eglycol is, the lower mixing specific heat of Eglycol water. And the cycle flux and electric power were 1.65 and 1.54 times more required. respectively, than water was used as the heating medium. Basic variables including mass flux according to the mixing ratio of Eglycol water, required electric power of operating fluid pumps, the temperature of natural gas which is supplied to the engine, and the heat exchanger's capacity were drawn from the gotten results.

Heat Transfer Characteristics of CO2 at Supercritical Pressure in a Vertical Circular Tube (수직원형관에서 초임계압 CO2의 열전달 특성)

  • Yoo, Tae-Ho;Bae, Yoon-Yong;Kim, Hwan-Yeol
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.35 no.1
    • /
    • pp.23-31
    • /
    • 2011
  • At supercritical pressure, the physical properties of fluid change substantially and the heat transfer at a temperature similar to the critical or pseudo-critical temperature improves considerably; however, the heat transfer may deteriorate due to a sudden increase in the wall temperature at a certain condition of a mass and heat flux. In this study, the heat transfer rates in $CO_2$ flowing vertically upward and downward in a circular tube with a diameter of 4.57 mm under various conditions were calculated by measuring the temperature of the outer wall of the tube. The published heat transfer correlations were analyzed by comparing their prediction values with 7,250 experimental data. By introducing a buoyancy parameter, a heat transfer correlation, which could be applied only to a normal heat transfer regime, was extended such that it can be applied to regime of heat transfer deterioration. The published criteria for heat transfer deterioration were evaluated against the conditions obtained from the experiment in this study.

Numerical Analysis of Heat Transfer in Multichannel Volumetric Solar Receivers (다채널 체적식 태양열 흡수기에서 열전달 수치해석)

  • Lee, Hyun-Jin;Kim, Jong-Kyu;Lee, Sang-Nam;Kang, Yong-Heack
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.35 no.12
    • /
    • pp.1383-1389
    • /
    • 2011
  • The current study focuses on the consistent analysis of heat transfer in multichannel volumetric solar receivers used for concentrating solar power. Changes in the properties of the absorbing material and channel dimensions are considered in an optical model based on the Monte Carlo ray-tracing method and in a one-dimensional heat transfer model that includes conduction, convection, and radiation. The optical model results show that most of the solar radiation energy is absorbed within a very small channel length of around 15 mm because of the large length-to-radius ratio. Classification of radiation losses reveals that at low absorptivity, increased reflection losses cause reduction of the receiver efficiency, notwithstanding the decrease in the emission loss. As the average temperature increases because of the large channel radius or small mass flow rate, both emission and reflection losses increase but the effect of emission losses prevails.

RADIOLOGICAL CHARACTERISTICS OF DECOMMISSIONING WASTE FROM A CANDU REACTOR

  • Cho, Dong-Keun;Choi, Heui-Joo;Ahmed, Rizwan;Heo, Gyun-Young
    • Nuclear Engineering and Technology
    • /
    • v.43 no.6
    • /
    • pp.583-592
    • /
    • 2011
  • The radiological characteristics for waste classification were assessed for neutron-activated decommissioning wastes from a CANDU reactor. The MCNP/ORIGEN2 code system was used for the source term analysis. The neutron flux and activation cross-section library for each structural component generated by MCNP simulation were used in the radionuclide buildup calculation in ORIGEN2. The specific activities of the relevant radionuclides in the activated metal waste were compared with the specified limits of the specific activities listed in the Korean standard and 10 CFR 61. The time-average full-core model of Wolsong Unit 1 was used as the neutron source for activation of in-core and ex-core structural components. The approximated levels of the neutron flux and cross-section, irradiated fuel composition, and a geometry simplification revealing good reliability in a previous study were used in the source term calculation as well. The results revealed the radioactivity, decay heat, hazard index, mass, and solid volume for the activated decommissioning waste to be $1.04{\times}10^{16}$ Bq, $2.09{\times}10^3$ W, $5.31{\times}10^{14}\;m^3$-water, $4.69{\times}10^5$ kg, and $7.38{\times}10^1\;m^3$, respectively. According to both Korean and US standards, the activated waste of the pressure tubes, calandria tubes, reactivity devices, and reactivity device supporters was greater than Class C, which should be disposed of in a deep geological disposal repository, whereas the side structural components were classified as low- and intermediate-level waste, which can be disposed of in a land disposal repository. Finally, this study confirmed that, regardless of the cooling time of the waste, 15% of the decommissioning waste cannot be disposed of in a land disposal repository. It is expected that the source terms and waste classification evaluated through this study can be widely used to establish a decommissioning/disposal strategy and fuel cycle analysis for CANDU reactors.

CFD validation for subcooled boiling under low pressure (저압에서의 과냉각 비등 현상에 대한 CFD의 유효성 검토)

  • Choi, Yong-Seok;Kim, You-Taek;Lim, Tae-Woo
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.40 no.4
    • /
    • pp.275-281
    • /
    • 2016
  • Subcooled boiling under low pressure was numerically investigated using computational fluid dynamics(CFD). The wall boiling model was used for simulating the subcooled boiling; this model requires sub-models consisting of bubble departure diameter, nucleation site density and bubble departure frequency. The CFD code CFX provides the default models based on experimental data. Because these models are mostly developed under high pressure conditions, it would not be predicted well in low pressure conditions. Thus in this study, CFD validation for subcooled boiling under low pressure was analyzed. The numerical results were compared with experimental data from published paper. Simulations were performed with mass flux ranging from 250 to $750kg/m^2s$, heat flux ranging from 0.37 to $0.77MW/m^2$ and constant outlet pressure of 0.11 MPa. Employing the empirical correlation developed under low pressures could increase the accuracy of numerical analysis.

An Experimental Study on the Effect of Low Fin Tube Geometry on Pool Boiling of a LiBr Solution (낮은 핀관의 형상이 LiBr 수용액의 풀 비등에 미치는 영향에 대한 실험적 연구)

  • Kim, Nae-Hyun
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.39 no.7
    • /
    • pp.591-598
    • /
    • 2015
  • Pool boiling heat transfer coefficients of a LiBr solution were obtained for seven low fin tubes having different fin pitch and fin height. The test range covered saturation pressure from 7.38kPa to 101.3kPa, heat flux from $20kW/m^2$ to $40 kW/m^2$ and LiBr concentration from 0% to 50%. The optimum fin geometry for the present experimental range turned out to be 26 fpi with 0.18 mm fin height.The advantage of added heat transfer area and the disadvantage of slower bubble growth and departure appear to have yielded an optimum fin pitch. The heat transfer coefficient decreased as saturation pressure decreased and Libr concentration increased. The reason may be attributed to the low saturation pressure, which increased the bubble departure diameter and decreased the bubble departure frequency. As the LiBr concenreation increased, the saturation temperature increased and the mass diffusion rate decreased, which resulted in a reduced heat transfer coefficient. The heat transfer coefficients of the low fin tube were greater than those of the smooth tube. Correlations were developed based on the present data.

Assessment of CHF Correlations for Internally Heated Concentric Annulus Channels

  • Park, Jae-Wook;Baek, Won-Pil;Chang, Soon-Heung
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1996.05b
    • /
    • pp.325-330
    • /
    • 1996
  • The existing CHF correlations for internally heated concentric annulus channels are assessed using KAIST CHF database for uniformly heated vertical annuli. Six annulus correlations (Jannsen-Kervinen. Barnett, Levitan-Lantsman, Kumamaru et al., Doerffer et al., and Bobkov et at.) are chosen for assessment based on literature survey and Groeneveld et al.'s CHF table for round tube is also assessed for comparison. Among the above correlations, two are inlet-condition type and others local conditions type. To make the comparison meaningful, the local-condition-type correlations are assessed in two ways: direct substitution method (DSM) and heat balance condition method (HBM). Totally 1174 data are classified into 10 groups based on pressure and mass flux conditions and correlations are assessed to each group separately. Prediction capability of each correlation depends on the data group and none shows the best prediction over the entire group. In overall, the correlations by Doerffer et al. and Jannsen et al. appear to be the best, but Barnett or Levitan-Lantsman correlations also show reasonable prediction for most groups. However, the low-pressure, ]ow flow CHFs are not well predicted by any correlations. The CHF table for round tubes overpredicts the CHF in annuli at fixed local conditions.

  • PDF

An Experimental Study on Pressure Drop of Boiling Flow within Horizontal Rectangular Channels with Small Heights (미세 수평 사각 유로 내에서의 비등 유동 압력강하에 관한 실험적 연구)

  • Lee, Sang-Yong;Lee, Han-Ju
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.25 no.9
    • /
    • pp.1219-1226
    • /
    • 2001
  • Pressure drops were measured for the flow boiling process within horizontal rectangular channels. The gap between the upper and the lower plates of each channel ranges from 0.4 to 2mm while the channel width being fixed to 20mm. Refrigerant 113 was used as the test fluid. The mass flux ranges from 50 to 200kg/㎡s and the channel walls were uniformly heated up to 15kW/㎡. The quality range covers from 0.15 to 0.75. The present experimental conditions coincide with the operating conditions of compact heat exchangers in which the liquid and gas flows are laminar and turbulent. The measured results were well represented by the two-phase frictional multiplier of Lee (2001) which has been developed for air-water two-phase flows within the deviation of $\pm$20%.

Effect of Pressurization and Cooling Rate on Dissolution of a Stationary Supercooled Aqueous Solution (정지상태 수용액에서 가압과 냉각속도가 과냉각해소에 미치는 영향)

  • Kim, Byung-Seon;Peck, Jong-Hyun;Hong, Hi-Ki;Kang, Chae-Dong
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.19 no.12
    • /
    • pp.850-856
    • /
    • 2007
  • In a supercooled or capsule type ice storage system, aqueous solution (or water) may have trouble with non-uniform dissolution though the system contributes to the simplicity of system and ecological improvement. The non-uniform dissolution increases the instability of the system because it may cause an ice blockage in pipe or cooling part. In order to observe the supercooled state, a cooling experiment was performed with pressurization to an ethylene glycol(EG) 3 mass% solution in stationary state. Also, the effect of the pressurization from 101 to 505 kPa to the dissolution of supercooled aqueous solution was measured with the dissolution time of the supercooled aqueous solution at a fixed cooling rate of brine. At results, the dissolution of supercooled point decreased as the pressure of the aqueous solution in the vessel increased. Moreover, the dissolution point increased as the heat flux for cooling increased.